PDF User Manual

  1. Home
  2. Manuals
  3. Clever Acoustics MA 135 User Manual

Clever Acoustics MA 135 User Manual

Made by: Clever Acoustics
Type: User Manual
Category: Amplifier
Pages: 12
Size: 3.29 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

MA 135 100V 35W  

Mixer Amplifier

User Manual

Order code: CRAM31

OUTPUTS

FUSE:

T800mA 250V

POWER INPUT:

240V~50Hz

www.cleveracoustics.co.uk

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

PRIORITY

MA 135 Mixer Amplifier

EQUALISER

MIC 1

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

MIC 2

LINE 1/LINE 2

150Hz

1kHz

6kHz

LINE 1

LINE 2

LINE 2

MIC 1

MIC 2

L

R

LINE 1

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

0

1

2

3

4

5

6

7

8

9

10

MASTER VOLUME

POWER

ON

OFF

POWER CONSUMPTION: 38W (max.)

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

2

Safety advice

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available voltage is 240V, 50Hz.
•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again.

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Prolight 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  WARRANTY: Three years from date of purchase.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

3

Product overview & technical specifications

A compact, desktop mixer amplifier suitable for small offices, retail spaces and garage forecourts. Featuring two 

microphone inputs via 6.35mm (¼” jack) each with independent level controls, two switchable stereo audio inputs 

and a three band tone control. To facilitate paging, the amplifier features a switchable priority override for MIC 1.

• 100V and low impedance 4-16Ω loudspeaker output
• Two unbalanced microphone inputs via 6.35mm (¼” jack)  

each with independent level controls

• Switchable priority for MIC 1
• Phono-RIAA/LINE inputs (switchable) with level control
• Three band tone control (150Hz, 1kHz, 6kHz) ±10dB
• Master volume control
• Screw terminal loudspeaker outputs with touch proof cover
• Captive power connection
• Convection cooled for silent operation

MA 135 100V 35W Mixer Amplifier

OUTPUTS

FUSE:

T800mA 250V

POWER INPUT:

240V~50Hz

www.cleveracoustics.co.uk

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

PRIORITY

MA 135 Mixer Amplifier

EQUALISER

MIC 1

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

MIC 2

LINE 1/LINE 2

150Hz

1kHz

6kHz

LINE 1

LINE 2

LINE 2

MIC 1

MIC 2

L

R

LINE 1

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

0

1

2

3

4

5

6

7

8

9

10

MASTER VOLUME

POWER

ON

OFF

POWER CONSUMPTION: 38W (max.)

Specifications

MA 135 Mixer Amplifier

Power output

35Wrms (70W peak)

Speaker output

100V & 4-16Ω

Microphone sensitivity

-55dB (±2dB)

Aux input sensitivity

-20dB (±2dB)

Frequency response

100Hz-18kHz (±3dB)

Tone control

±10dB

S/N ratio

>55dB

THD

<1% (@1kHz 1W output)

Power consumption

38W (max.)

Power supply

240V AC 50Hz / 12V DC (2.5A)

Fuse

T800mA 250V

Dimensions

84 x 320 x 235mm

Weight

5kg

Order code

CRAM31

0

1

2

3

4

5

6

7

8

9

10

MASTER VOLUME

POWER

ON

OFF

MA 135 Mixer Amplifier

EQUALISER

MIC 1

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

MIC 2

LINE 1/LINE 2

150Hz

1kHz

6kHz

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

8

4mm

320mm

235mm

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

4

Panel & connection identification

01 - Power on/off switch
02 - Power LED
03 - Master volume control
04 - 6kHz tone control
05 - 1kHz tone control
06 - 150Hz tone control
07 - LINE 1/LINE 2 level control

08 - MIC 1 level control
09 - MIC 2 level control
10 - MIC 1 input
11 - MIC 2 input
12 - Fuse: T800mA 250V
13 - Captive power connection
14 - Priority control terminals

15 - Loudspeaker output terminals
16 - LINE 1/LINE 2 selector switch
17 - LINE 1 input RCA connectors  

  - LINE  Level

18 - LINE 2 input RCA connectors  

  - RIAA for Turntable Connection

19 - Ground connection

OUTPUTS

FUSE:

T800mA 250V

POWER INPUT:

240V~50Hz

www.cleveracoustics.co.uk

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

PRIORITY

MA 135 Mixer Amplifier

EQUALISER

MIC 1

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

MIC 2

LINE 1/LINE 2

150Hz

1kHz

6kHz

LINE 1

LINE 2

LINE 2

MIC 1

MIC 2

L

R

LINE 1

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

0

1

2

3

4

5

6

7

8

9

10

MASTER VOLUME

POWER

ON

OFF

POWER CONSUMPTION: 38W (max.)

8

9

6

7

5

4

3

1

2

OUTPUTS

FUSE:

T800mA 250V

POWER INPUT:

240V~50Hz

www.cleveracoustics.co.uk

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

PRIORITY

MA 135 Mixer Amplifier

EQUALISER

MIC 1

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

MIC 2

LINE 1/LINE 2

150Hz

1kHz

6kHz

LINE 1

LINE 2

LINE 2

MIC 1

MIC 2

L

R

LINE 1

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

0

1

2

3

4

5

6

7

8

9

10

MASTER VOLUME

POWER

ON

OFF

POWER CONSUMPTION: 38W (max.)

13

15

14

16

18

11

19

17

10

12

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

5

Mains voltage supply: 

Before connecting the amplifier to the local mains voltage outlet should be checked to ensure the 
available supply is 240V~AC 50Hz. This product is CLASS1 and requires a protective mains earth to be 
connected at all times. 

DO NOT

 remove or disconnect the earth.

Power on/off procedure: 

After connecting your amplifier to the mains, turn all controls counter clockwise to the 

“0”

 position.  

Turn on audio sources (MP3 players, CD players, microphones etc) before powering the amplifier 

“ON”

. The last product to be switched on is the amplifier. If you wish to power off the system, turn the 

amplifier’s master volume control counter clockwise to the 

“0”

 position before switching the amplifier 

“OFF”

 before any audio sources are switched off. By following this procedure it will prevent acoustic 

shocks to the speakers or potential damage to system components. 
After connecting all audio sources and powering on the mixer amplifier, adjust the level of each audio 
input to achieve the desired 

“mix”

. Care should be taken to when adjusting microphone input volumes 

and the master volume, adjust both of these in small increment’s to avoid feedback (howl around).  
The goal is to achieve a clear balance between music and voice ensuring announcements can be  
clearly heard.

Master volume control:

The master volume control affects the level of all audio sources within the amplifier. Turn the level 
control anti-clockwise to the lowest setting, or turn clockwise to adjust the overall output to the highest 
setting. Adjustments should be made gradually to avoid any sudden changes to the audio output.  

Tone control:

The tone control can be used to adjust the overall sound from the amplifier. Each of the three controls 
adjust a different frequency band. Turn anti-clockwise to increase, or turn clockwise to decrease the 
selected frequency band.

Ground connection:

The ground connection can be used for vinyl turntable sources with external earth connections.

 
 
 
 
 
 
 
 

Operating instructions

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

6

Microphone inputs:

Two low impedance microphone inputs are provided, each located on the rear panel via an unbalanced, 
6.35mm (¼”) jack. Each microphone input features its own independent level control.  
Before connecting a microphone, turn the level control anti-clockwise to the lowest setting.  
After connection, gradually increase the level control by turning clockwise until the desired  
level is achieved. 
Note: Unbalanced cable lengths should be kept to the minimum length possible, ideally under  
20m and away from any potential sources of interference including power, speaker and control  
cables/equipment.

Priority control terminals (Music Mute):

The MA 135 amplifier features a priority feature for microphone 1. When the Priority contacts are 
shorted, the amplifier will mute all other inputs while microphone 1 will remain active. 

Line inputs:

The amplifier features two audio inputs located on the rear panel, each input features a pair of RCA 
(phono) input connectors configured in stereo.  
The LINE 1 input is designed for line level sources (150mV) such as CD players or MP3 players.  
The LINE 2 input is designed for RIAA level sources such as Turntables. 
Note: Only one of the two inputs may be used at any one time, the selector switch may be used to 
choose from the two inputs. Slide the switch to the left to select LINE 1 or slide to the right to LINE 2.

Operating instructions

MIC

Unbalanced microphone

Single pole phone plug

3mV

Selector switch

LINE 1

LINE 2

LINE 1

RIAA

RIAA

Priority

COM

+

16Ω

100V

LINE 2

150mV

150mV

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

7

Output connections:

The amplifier may be used to drive either low impedance (4/8/16Ω) loads or 100V line constant voltage 
loads, only one output may be used, the amplifier is not designed to drive multiple loads simultaneously.  
 

Low impedance:

The amplifier has been designed to drive into loads between 4Ω and 16Ω. The appropriate output 
terminal should be selected to match the impedance of the speakers to be connected. When installing 
low impedance speaker systems, the cable lengths should be kept to a minimum to help prevent 
voltage drop within the cable. 

DO NOT

 connect a speaker load to the amplifiers output terminals of lower 

impedance than is marked on the output terminals. 

100V Line:

For longer cable runs, the amplifier may be used to drive 100V loudspeaker systems reducing losses 
within the cable. Connect the 100V line level loudspeakers using a parallel wiring configuration taking 
care to ensure the load connected to the amplifier is within 85% of the amplifiers rated wattage to 
leave appropriate headroom. Care should be taken to check the wiring and load for short circuits before 
connecting the cable to the COM and 100V terminals on the rear panel.

Operating instructions

COM 4Ω 8Ω 16Ω 100V

100V

100V

100V

100V

+

-

+

-

COM 4Ω 8Ω 16Ω 100V

Total impedance: 4Ω

+

-

COM 4Ω 8Ω 16Ω 100V

Total impedance: 8Ω

+

-

+

-

COM 4Ω 8Ω 16Ω 100V

Total impedance: 16Ω

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

8

Typical panel connections

OUTPUTS

FUSE:

T800mA 250V

POWER INPUT:

240V~50Hz

www.cleveracoustics.co.uk

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

PRIORITY

MA 135 Mixer Amplifier

EQUALISER

MIC 1

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

MIC 2

LINE 1/LINE 2

150Hz

1kHz

6kHz

LINE 1

LINE 2

LINE 2

MIC 1

MIC 2

L

R

LINE 1

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

0

1

2

3

4

5

6

7

8

9

10

MASTER VOLUME

POWER

ON

OFF

POWER CONSUMPTION: 38W (max.)

MAINS

TURNTABLE

LOUDSPEAKERS

MP3 PLAYER

MIC 1

MIC 2

PRIORITY 

RELAY

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

9

Schematics

V

R

1

A

50

K

V

R

2

A

50

K

V

R

3

A

50

K

1

2

3

 

L

 

R

 

L

 

R

R

58

56

K

R

61

10

K

R

60

27

K

R

13

5.

6K

R

14

5.

6K

R

16

2.

2K

R

17

2.

2K

R

15

10

K

R

20 27

0

R

19

10

0K

R

24

33

0K

R

25

5.

6K

R

22

18

K

R

23

39

0K

R

20 27

0

R

21

68

0

C

18

47

0P

C

17

10

0P

C

15

(M

C

).0

03

3U

C

16

(M

C

).0

15

U

C

13

47

0

C

12

.0

01

U

C

20

1U

/5

0V

C

11

10

U

/1

6V

C

14

47

U

/2

5V

C

10

.0

01

U

S1

 

Q

3

C

18

15

Q

4

C

18

15

R

41

10

0

R

40

1.

2K

R

37

12

K

R

38

8.

2K

D

4

40

01

C

30

47

U

/2

5V

C

31

10

0U

/5

0V

R

34

1W

 2

.2

K

R

35

1W

 4

7

R

36

10

K

Q

7

C

18

15

Q

8

C

18

15

C

33

10

0U

/5

0V

C

32

47

U

/2

5V

D

5

1/

2W

 9

.1

V

R

39

4.

7K

A

C

1

A

C

2

+

3

-

4

B

1

 

C

21

(M

C

).0

04

7U

C

22

(M

C

).0

04

7U

C

23

22

00

U

/3

5V

C

24

22

00

U

/3

5V

D

1

40

01

P

T

 

P

O

W

-S

W

 

F

U

SE

 

A

C

 2

4O

V

50

H

Z

/5

0W

C

28

10

U

/1

6V

C

N

4

L

E

D

 P

O

W

R

27

33

K

R

29

47

K

1K

R

26

R

28

47

K

C

25

10

U

/1

6V

C

26

22

U

/1

6V

Q

5

C

18

15

Q

6

C

18

15

C

29

33

U

/1

6V

R

32

33

K

R

33 15

D

2

41

48

R

31

12

K

R

30 12

K

C

27

33

U

/1

6V

R

59

47

K

R

62

82

K

Q

19

C

18

15

Q

20

C

18

15

Q

16

C

18

15

Q

17

C

18

15

Q

18

C

18

15

Q

14

D

71

8

Q

12

C

22

40

Q

13

A

10

15

Q

11

A

10

15

Q

9

C

22

40

Q

10

C

22

40

R

82

22

K

R

81

7.

5K

R

83 7.5

K

R

87 1K

R

86

7.

5K

R

84

4.

7K

R

67

1K

R

85

12

K

R

68

33

P

R

63 68

0

R

78

27

0K

R

79

10

K

R

64

22

K

R

65

3.

9K

R

69

82

K

R

71

82

0

R

70

5.

6K

R

72

75

K

R

73

68

0

R

80

10

K

R

75

75

K

R

76 82

0

R

77

5.

6K

D

12

41

48

D

13

1/

2W

 3

V

C

58

10

0U

/1

6V

C

57

10

U

/1

6V

C

40

.4

7U

/5

0V

C

43

10

U

/1

6V

C

44

1U

/5

0V

C

46

.4

7U

/5

0V

C

55

(M

C

).0

33

U

C

54

.2

2U

/5

0V

C

53

1U

/5

0V

C

38

10

U

/1

6V

C

56

10

U

/1

6V

V

R

7

A

50

K

V

R

4

W

50

K

V

R

5

W

50

K

V

R

6

W

50

K

6

5

7

U

1B

M

C

45

58

G

2

3

1

8

4

U

1A

M

C

45

58

G

C

41

33

P

C

59

(M

C

).0

68

U

C

45

15

0P

C

42

33

P

C

49

33

P

C

51

10

P

C

48

(M

C

).0

15

U

C

50

(M

C

).0

02

2U

C

52

33

0P

R

66

3.

9K

C

47 33

P

R

74

5.

6K

1 2

1

2

Q

15

D

71

8

R

49

4.

7K

R

50 10

0

R

55

5W

 0

.2

R

51 10

R

47

15

0

R

48

4.

7K

R

52 15

R

54

27

K

R

53

10

0

R

43 2K

R

57

10

R

46

82

0

R

44

39

K

R

45

5.

6K

R

42

22

K

D

6

1W

 1

8V

D

7

40

01

C

34

.4

7U

/5

0V

C

37 22

P

C

35

10

0U

/5

0V

C

36

10

0U

/5

0V

D

11

41

48

D

10

41

48

D

9

41

48

D

8

41

48

R

56

5W

 0

.2

 

O

P

T-

30

W

R

86

1W

 1

0

1 2

C

O

M

O

H

M

O

H

M

16

 O

H

M

10

0V

C

N

9

C

39

10

0P

M

1

M

2

G

N

D

A

U

X

G

N

D

O

U

T

M

1

M

2

G

N

D

A

U

X

G

N

D

O

U

T

O

T

C

N

6

C

N

8

PR

IO

R

IT

Y

C

N

PT

 IN

O

U

T

+2

3V

-V

C

C

+V

C

C

A

U

X

PH

O

N

O

1

2

3

4

5

6

 

C

N

7

1 2 3 4 5 6

 

C

N

2

!

!

!

!

!

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

10

WEEE notice

Correct Disposal of this Product 
(Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries  
with separate collection systems)

This marking shown on the product or its literature, indicates that it should not be disposed  
with other household wastes at the end of its working life. To prevent possible harm to the  
environment or human health from uncontrolled waste disposal, please separate this from other 
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their 
local government office, for details of where and how they can take this item for environmentally 
safe recycling.

Business users should contact their supplier and check the terms and conditions of the  
purchase contract. This product should not be mixed with other commercial wastes for disposal.

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

11

 


background image

www.cleveracoustics.co.uk

MA 135 Mixer Amplifier

  

User Manual

12