PDF User Manual

  1. Home
  2. Manuals
  3. Clever Acoustics MA 120 User Manual

Clever Acoustics MA 120 User Manual

Made by: Clever Acoustics
Type: User Manual
Category: Amplifier
Pages: 12
Size: 3.62 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

MA 120 100V 20W  

Mixer Amplifier

User Manual

Order code: CRAM30

0

1

2

3

4

5

6

7

8

9

10

MA 120 Mixer Amplifier

MIC 1

MIC 2

MIC 1

0

1

2

3

4

5

6

7

8

9

10

MIC 2

0

1

2

3

4

5

6

7

8

9

10

LINE 1/LINE 2

0

1

2

3

4

5

6

7

8

9

10

TONE

MASTER VOLUME

POWER

ON

OFF

LOW

HIGH

OUTPUTS

FUSE:

T500mA 250V

POWER INPUT:

240V~50Hz

LINE 2

LINE 1

LINE 2

LINE 1

www.cleveracoustics.co.uk

DC 12V      2.5A

+

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

POWER CONSUMPTION: 22W (max.)

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

2

Safety advice

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available voltage is  

240V, 50Hz AC or 12V DC.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again.

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Prolight 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  WARRANTY: Three years from date of purchase.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

3

Product overview & technical specifications

A compact, desktop mixer amplifier suitable for small offices, retail spaces and garage forecourts. The 12V DC 

input allows the amplifier to be powered from DC power backup sources or alternatively from leisure type batteries 

for sound reinforcement in remote locations away from mains power. 

• 100V and low impedance 4-16Ω loudspeaker output
• Two unbalanced microphone inputs via 6.35mm  

( ¼” jack) each with independent level controls

• Line 1/2 inputs (switchable) with level control
• Master tone control
• Master volume control
•  Screw terminal loudspeaker outputs  

with touch proof cover

• Captive power connection
• Convection cooled for silent operation

MA 120 100V 20W Mixer Amplifier

0

1

2

3

4

5

6

7

8

9

10

MA 120 Mixer Amplifier

MIC 1

MIC 2

MIC 1

0

1

2

3

4

5

6

7

8

9

10

MIC 2

0

1

2

3

4

5

6

7

8

9

10

LINE 1/LINE 2

0

1

2

3

4

5

6

7

8

9

10

TONE

MASTER VOLUME

POWER

ON

OFF

LOW

HIGH

OUTPUTS

FUSE:

T500mA 250V

POWER INPUT:

240V~50Hz

LINE 2

LINE 1

LINE 2

LINE 1

www.cleveracoustics.co.uk

DC 12V      2.5A

+

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

POWER CONSUMPTION: 22W (max.)

Specifications

MA 120 Mixer Amplifier

Power output

20Wrms (40W peak)

Speaker output

100V & 4-16Ω

Microphone sensitivity

-48dB (±2dB)

Aux input sensitivity

-12dB (±2dB)

Frequency response

100Hz-13kHz (±3dB)

Tone control

±10dB

S/N ratio

>55dB

THD

<1% (@1kHz 1W output)

Power consumption

22W (max.)

Power supply

240V AC 50Hz / 12V DC (2.5A)

Fuse

T500mA 250V

Dimensions

84 x 320 x 235mm

Weight

4.2kg

Order code

CRAM30

0

1

2

3

4

5

6

7

8

9

10

MA 120 Mixer Amplifier

MIC 1

MIC 2

MIC 1

0

1

2

3

4

5

6

7

8

9

10

MIC 2

0

1

2

3

4

5

6

7

8

9

10

LINE 1/LINE 2

0

1

2

3

4

5

6

7

8

9

10

TONE

MASTER VOLUME

POWER

ON

OFF

LOW

HIGH

8

4mm

320mm

235mm

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

4

Panel & connection identification

01 - Power on/off switch
02 - Power LED
03 - Master volume control
04 - Tone control
05 - LINE 1/LINE 2 level control
06 - MIC 1 level control

07 - MIC 2 level control
08 - MIC 1 input
09 - MIC 2 input
10 - Fuse: T500mA 250V
11 - Captive power connection
12 - DC power input terminals

13 - Loudspeaker output terminals
14 - LINE 1/LINE 2 selector switch
15 - LINE 1 input RCA connector
16 - LINE 2 input RCA connector
17 - Ground connection

0

1

2

3

4

5

6

7

8

9

10

MA 120 Mixer Amplifier

MIC 1

MIC 2

MIC 1

0

1

2

3

4

5

6

7

8

9

10

MIC 2

0

1

2

3

4

5

6

7

8

9

10

LINE 1/LINE 2

0

1

2

3

4

5

6

7

8

9

10

TONE

MASTER VOLUME

POWER

ON

OFF

LOW

HIGH

OUTPUTS

FUSE:

T500mA 250V

POWER INPUT:

240V~50Hz

LINE 2

LINE 1

LINE 2

LINE 1

www.cleveracoustics.co.uk

DC 12V      2.5A

+

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

POWER CONSUMPTION: 22W (max.)

8

9

6

7

5

4

3

1

2

0

1

2

3

4

5

6

7

8

9

10

MA 120 Mixer Amplifier

MIC 1

MIC 2

MIC 1

0

1

2

3

4

5

6

7

8

9

10

MIC 2

0

1

2

3

4

5

6

7

8

9

10

LINE 1/LINE 2

0

1

2

3

4

5

6

7

8

9

10

TONE

MASTER VOLUME

POWER

ON

OFF

LOW

HIGH

OUTPUTS

FUSE:

T500mA 250V

POWER INPUT:

240V~50Hz

LINE 2

LINE 1

LINE 2

LINE 1

www.cleveracoustics.co.uk

DC 12V      2.5A

+

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

POWER CONSUMPTION: 22W (max.)

11

13

12

14

16

17

15

10

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

5

Mains voltage supply: 

Before connecting the amplifier to the local mains voltage outlet should be checked to ensure the 
available supply is 240V~AC 50Hz. This product is CLASS1 and requires a protective mains earth to be 
connected at all times. 

DO NOT

 remove or disconnect the earth.

Power on/off procedure: 

After connecting your amplifier to the mains, turn all controls counter clockwise to the 

“0”

 position.  

Turn on audio sources (MP3 players, CD players, microphones etc) before powering the amplifier 

“ON”

. The last product to be switched on is the amplifier. If you wish to power off the system, turn the 

amplifier’s master volume control counter clockwise to the 

“0”

 position before switching the amplifier 

“OFF”

 before any audio sources are switched off. By following this procedure it will prevent acoustic 

shocks to the speakers or potential damage to system components. 
After connecting all audio sources and powering on the mixer amplifier, adjust the level of each audio 
input to achieve the desired 

“mix”

. Care should be taken to when adjusting microphone input volumes 

and the master volume, adjust both of these in small increment’s to avoid feedback (howl around).  
The goal is to achieve a clear balance between music and voice ensuring announcements can be  
clearly heard.

DC power connection: 

The MA 120 features a 12V DC power input for operation from leisure type batteries or from battery DC 
backup sources. The amplifier should be connected to a fused, 12V DC source via the DC power input 
terminals (11) ensuring care is taken to observe the correct polarity. The amplifier will automatically 
transfer to DC operation should the main 240V input fail. The transfer is instantaneous and silent.  

Please note:

 The power on/off switch does not have any control over the 12V DC power input.

Master volume control:

The master volume control affects the level of all audio sources within the amplifier. Turn the level 
control anti-clockwise to the lowest setting, or turn clockwise to adjust the overall output to the highest 
setting. Adjustments should be made gradually to avoid any sudden changes to the audio output.  

Operating instructions

DC 12V

Battery

12V DC 

input

COM

+

16Ω

100V

FUSE

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

6

Tone control:

The tone control can be used to adjust the overall sound from the amplifier. Turn anti-clockwise for more 
bass, or turn clockwise for more mid & treble. 

Microphone inputs:

Two low impedance microphone inputs are provided, each located on the front panel via an unbalanced, 
6.35mm (¼”) jack. Each microphone input features its own independent level control.  
Before connecting a microphone, turn the level control anti clockwise to the lowest setting.  
After connection, gradually increase the level control by turning clockwise until the desired  
level is achieved. 
Note: Unbalanced cable lengths should be kept to the minimum length possible, ideally under  
20m and away from any potential sources of interference including power, speaker and control  
cables/equipment.

Line inputs:

The amplifier features two audio inputs located on the rear panel, each input features a mono RCA 
(phono) input connector. The line inputs are designed for line level sources (150mV) such as CD players  
or MP3 players. A “Y” cable may be required to combine Left and Right outputs from stereo sources. 
Note: Only one of the two inputs may be used at any one time, the selector switch may be used to 
choose from the two inputs. Slide the switch to the left to select LINE 2 or slide to the right to LINE 1.

Output connections:

The amplifier may be used to drive either low impedance (4/8/16Ω) loads or 100V line constant voltage 
loads, only one output may be used, the amplifier is not designed to drive multiple loads simultaneously.  
 
 
 

Operating instructions

MIC

Unbalanced microphone

Single pole phone plug

3mV

Selector switch

LINE 2

LINE 2

LINE 1

LINE 1

150mV

150mV

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

7

Low impedance:

The amplifier has been designed to drive into loads between 4Ω and 16Ω. The appropriate output 
terminal should be selected to match the impedance of the speakers to be connected. When installing 
low impedance speaker systems, the cable lengths should be kept to a minimum to help prevent 
voltage drop within the cable. 

DO NOT

 connect a speaker load to the amplifiers output terminals of lower 

impedance than is marked on the output terminals. 

100V Line:

For longer cable runs, the amplifier may be used to drive 100V loudspeaker systems reducing losses 
within the cable. Connect the 100V line level loudspeakers using a parallel wiring configuration taking 
care to ensure the load connected to the amplifier is within 85% of the amplifiers rated wattage to 
leave appropriate headroom. Care should be taken to check the wiring and load for short circuits before 
connecting the cable to the COM and 100V terminals on the rear panel.

Operating instructions

COM 4Ω 8Ω 16Ω 100V

100V

100V

100V

100V

+

-

+

-

COM 4Ω 8Ω 16Ω 100V

Total impedance: 4Ω

+

-

COM 4Ω 8Ω 16Ω 100V

Total impedance: 8Ω

+

-

+

-

COM 4Ω 8Ω 16Ω 100V

Total impedance: 16Ω

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

8

Typical panel connections

0

1

2

3

4

5

6

7

8

9

10

MA 120 Mixer Amplifier

MIC 1

MIC 2

MIC 1

0

1

2

3

4

5

6

7

8

9

10

MIC 2

0

1

2

3

4

5

6

7

8

9

10

LINE 1/LINE 2

0

1

2

3

4

5

6

7

8

9

10

TONE

MASTER VOLUME

POWER

ON

OFF

LOW

HIGH

OUTPUTS

FUSE:

T500mA 250V

POWER INPUT:

240V~50Hz

LINE 2

LINE 1

LINE 2

LINE 1

www.cleveracoustics.co.uk

DC 12V      2.5A

+

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

POWER CONSUMPTION: 22W (max.)

MIC 1

MIC 2

0

1

2

3

4

5

6

7

8

9

10

MA 120 Mixer Amplifier

MIC 1

MIC 2

MIC 1

0

1

2

3

4

5

6

7

8

9

10

MIC 2

0

1

2

3

4

5

6

7

8

9

10

LINE 1/LINE 2

0

1

2

3

4

5

6

7

8

9

10

TONE

MASTER VOLUME

POWER

ON

OFF

LOW

HIGH

OUTPUTS

FUSE:

T500mA 250V

POWER INPUT:

240V~50Hz

LINE 2

LINE 1

LINE 2

LINE 1

www.cleveracoustics.co.uk

DC 12V      2.5A

+

SERIAL NUMBER

COM

16Ω 100V

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

POWER CONSUMPTION: 22W (max.)

MAINS

CD PLAYER

LOUDSPEAKERS

MP3 PLAYER

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

9

Schematics

V

R

3

A

50

K

R

31

18

K

C

33

10

0U

/1

6V

C

35

10

0U

/1

6V

C

32

.4

7U

/5

0V

C

36

.4

7U

/5

0V

R

32

2.

2K

R

33

2.

2K

 

R

29

5.

6K

R

28

1M

V

R

4

A

20

K

C

34

22

0P

C

37

(M

C

).0

33

U

Q

5

C

18

15

V

R

5

B

50

K

1

2

3

4

C

N

2

 

R

30 1K

D

1

41

48

D

2

41

48

C

38

22

0P

C

39

10

0P

C

40

(M

C

).1

U

C

18

(M

C

).1

U

C

19

(M

C

).1

U

C

20

(C

C

).1

U

C

11

2.

2U

/5

0V

C

12

2.

2U

/5

0V

C

13

2.

2U

/5

0V

C

14

4.

7U

/5

0V

C

17

10

0U

/1

6V

C

15

10

0U

/1

6V

C

16

2.

2U

/5

0V

R

11 56

0

R

12

18

0K

R

13

1.

5K

R

15

1W

/1

R

14

47

0

R

16

4.

7K

 O

PT

  A

U

X

  PH

O

N

O

R

9

20

K

R

3

68

0

R

10

3.

3K

R

4

2.

7K

R

1

10

0K

R

5

47

K

R

6

1.

8K

R

7

56

K

R

2

33

0

R

8

2.

2K

R

17 47

0

R

18

1W

/1

K

R

19

1.

5K

C

10

.0

01

U

C

3

22

0P

C

5

(M

C

).0

47

U

C

7

68

P

C

6

(M

C

).0

22

U

C

1

.0

01

U

C

23

(M

C

).0

47

U

C

2

10

U

/1

6V

C

4

10

U

/1

6V

C

8

.4

7U

/5

0V

C

9

10

0U

/1

6V

C

21

22

0U

/2

5V

C

22

47

00

U

/5

0V

Q

2

C

18

15

Q

1

C

18

15

 PO

W

-S

W

FU

SE

1A

/2

50

V

 P

T

A

C

 2

40

V

50

H

35

W

D

3

3A

LE

D

C

N

3

A

C

1

A

C

2

+

3

-

4

B

1

B

R

10

6

S1

 

1

2

3

4

 

C

N

1

C

O

M

O

H

M

O

H

M

16

 O

H

M

10

0V

C

N

6

O

IN

 

1 2

1

2

C

N

4

C

N

5

D

C

 IN

 1

2V

P

IN

 

VO

L-

PC

B

PO

W

 P

C

B

A

C

15

.5

V

1 2

+ -

K

IA

62

80

H

U

1

R

34

27

0

!

!

!

!

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

10

WEEE notice

Correct Disposal of this Product 
(Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries  
with separate collection systems)

This marking shown on the product or its literature, indicates that it should not be disposed  
with other household wastes at the end of its working life. To prevent possible harm to the  
environment or human health from uncontrolled waste disposal, please separate this from other 
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their 
local government office, for details of where and how they can take this item for environmentally 
safe recycling.

Business users should contact their supplier and check the terms and conditions of the  
purchase contract. This product should not be mixed with other commercial wastes for disposal.

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

11

 


background image

www.cleveracoustics.co.uk

MA 120 Mixer Amplifier

  

User Manual

12