PDF User Manual

  1. Home
  2. Manuals
  3. Clever Acoustics CRAM19A User Manual

Clever Acoustics CRAM19A User Manual

CRAM19\ ZM8\ CRAM19D\ CRMIC07\ CRAM19B\ CRAM19C

Made by: Clever Acoustics
Type: User Manual
Category: Amplifier
Pages: 17
Size: 22.27 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

ZM8 Matrix Zone System 

8 Zone Mixer and Wall Controllers

User Manual

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

1.5V/600

    

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

LF

HF

MICROPHONE 1

GAIN

-8

+8

dB

PAGING  MIC1

PAGING  MIC2

-

+

dB

GAIN

GAIN

-

+

dB

LINE 1

LINE 2

R

L

R

L

-

+

dB

GAIN

GAIN

-

+

dB

LINE 3

LINE 4

GAIN

-

+

dB

GAIN

-

+

dB

-8

+8

dB

dB

-

+

dB

OUTPUT

    

REMOTE SOURCE 1

HF

LF

0V

0V

0V

0V

0V

0V

0V

0V

1

1

1

1

1

1

1

1

+

+

+

+

+

+

+

+

3

3

3

3

3

3

3

3

-

-

-

-

-

-

-

-

2

2

2

2

2

2

2

2

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

ZONE

    8 

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

0V

0V

0V

0V

0V

0V

0V

0V

1

1

1

1

1

1

1

1

+

+

+

+

+

+

+

+

3

3

3

3

3

3

3

3

-

-

-

-

-

-

-

-

2

2

2

2

2

2

2

2

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

ZONE

    1 

R

L

R

L

ZONE

    2 

ZONE

    3 

ZONE

    4 

ZONE

    5

ZONE

    6 

ZONE

    7 

    REMOTE SOURCE 2

    

    REMOTE SOURCE 3

    

    REMOTE SOURCE 4

    

    REMOTE SOURCE 5

    

    REMOTE SOURCE 6

 

   REMOTE SOURCE 7

    195mV-2V/47K

    195mV-2V/47K

  5mV-300mV/680

DISABLE

ENABLE

REMOTE

WALL CONTROL

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE 

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE 

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

    REMOTE SOURCE 8

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

MA

ST

ER

SL

AV

E

1

SL

AV

E2

SL

AV

E3

CO

MM

ON

AL

E

R

T

EV

A

C

GR

OU

ND

EM

IN

dB

1 2 3 4 5 6 7 8 G

CONTACT CLOSURE

FIRE ALARM

 LINK IN

 LINK OUT

 EXTENSION LINK

dB

+

-

+

-

  INPUT  VOLT AGE SELECTOR

dB

dB

dB

dB

dB

dB

dB

dB

-

-

-

-

-

-

-

-

+

+

+

+

+

+

+

+

+ - G

LINE 8

    MIC:5mV LINE:350mV

+ - G

LINE 7

    MIC:5mV LINE:350mV

+ - G

LINE 6

    MIC:5mV LINE:350mV

+ - G

M

IC

M

IC

MI

C

MI

C

LI

N

E

LI

NE

LI

N

E

LI

NE

P

HA

NT

OM

PH

AN

TO

M

PH

AN

TO

M

PH

AN

TO

M

LINE 5

    MIC:5mV LINE:350mV

EMC

INPUT

OUTPUT

TONE

-10

+10

dB

775mV/10K

BA

TT

 S

U

PPL

Y

   

    

  

 24

V

 2A

~120V/240V  50-60Hz

120V

240V

1 2 3 4

ON

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

ZM8 MIXER

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

ZM8 MIXER

ON

SOURCE 

UP 

SOURCE 

LEVEL

SOURCE

DOWN

1

3

2

4

5

7

6

8

1

2

3

MIC 

2

3

4

5

0

1

6

7

8

10

  

9

LINE 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

MIC 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

LINE

INPUT

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

1

2

3

MIC1

MIC2

MUSIC

MUTE

ON

1

2

3

-

+

HF

LF

-

+

-

+

HF

LF

-

+

2

3

4

5

0

1

6

7

8

10

  

9

2

3

4

5

0

1

6

7

8

10

  

9

Order codes:  

CRAM19 - Matrix Zone Mixer

CRAM19A - BW Wall Plate
CRAM19B - CW Wall Plate
CRAM19C - DW Wall Plate

CRAM19D - PGC Remote Control

CRMIC07 - 8 Zone Paging Microphone

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

2

Contents

Safety advice ..............................................................................................3

Introduction ................................................................................................4

Specifications ............................................................................................5

Operation and controls ..............................................................................9

Overview .....................................................................................................9

Panel and connector identification ..........................................................9

RS 485 Protocol .........................................................................................13

Remote paging console ............................................................................12, 14

Typical configurations ...............................................................................15, 16

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

3

Safety advice

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available voltage is between 

100~240V, 50/60Hz.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again.

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  WARRANTY: One year from date of purchase.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

4

Product overview & technical specifications

The ZM8 Zone Mixer allows 8 signal sources plus 2 dedicated paging microphones to be routed into 8 separate 

zones. With the addition of more ZM8 zone mixers each system is expandable up to a total of 32 zones. Each zone 

can be controlled remotely via a wall plate which offers great flexibility, whilst control is also available centrally via 

the master front panel. In addition to offering control of level and source, the dedicated wall plates can allow a 

further balanced line input for each zone for connection of a local source, local microphone input or auxiliary input 

(depending on the plate selected). Installation of the plates requires simple, easy connection via standard RJ45 

terminated CAT5 cable.

• Each channel input is provided with individual microphone, 

music, master volume control, each line and paging 
console input with gain control, microphone input with gain, 
bass and treble tone control

• Each channel output is provided with individual gain, bass 

and treble tone control, a gain control is also provided for 
each channel’s remote wall control

• 8 zone voice alarm contact closure to activate built-in tone 

voice alarm

• Alert, evacuation and alarm; three styles of pre-recorded 

chimes are provided with tone control

• EMC and ground for external voice alarm generator input
• Connected via standard RJ45 terminated CAT 5 cable
• 4 swift keys for direct all channel BGM and paging access 

 
 
 
 
 
 
 
 

• 5 levels of priority from highest to lowest are: MIC 1, fire 

alarm, remote paging console, remote control panel and 
background music

• AC 110V or 240V input with voltage switch and DC 24V 

operation

• Monitor output with independent volume control

ZM8 Matrix Zone Mixer

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

1.5V/600

    

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

LF

HF

MICROPHONE 1

GAIN

-8

+8

dB

PAGING  MIC1

PAGING  MIC2

-

+

dB

GAIN

GAIN

-

+

dB

LINE 1

LINE 2

R

L

R

L

-

+

dB

GAIN

GAIN

-

+

dB

LINE 3

LINE 4

GAIN

-

+

dB

GAIN

-

+

dB

-8

+8

dB

dB

-

+

dB

OUTPUT

    

REMOTE SOURCE 1

HF

LF

0V

0V

0V

0V

0V

0V

0V

0V

1

1

1

1

1

1

1

1

+

+

+

+

+

+

+

+

3

3

3

3

3

3

3

3

-

-

-

-

-

-

-

-

2

2

2

2

2

2

2

2

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

ZONE

    8 

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

0V

0V

0V

0V

0V

0V

0V

0V

1

1

1

1

1

1

1

1

+

+

+

+

+

+

+

+

3

3

3

3

3

3

3

3

-

-

-

-

-

-

-

-

2

2

2

2

2

2

2

2

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

ZONE

    1 

R

L

R

L

ZONE

    2 

ZONE

    3 

ZONE

    4 

ZONE

    5

ZONE

    6 

ZONE

    7 

    REMOTE SOURCE 2

    

    REMOTE SOURCE 3

    

    REMOTE SOURCE 4

    

    REMOTE SOURCE 5

    

    REMOTE SOURCE 6

 

   REMOTE SOURCE 7

    195mV-2V/47K

    195mV-2V/47K

  5mV-300mV/680

DISABLE

ENABLE

REMOTE

WALL CONTROL

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE 

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE 

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

    REMOTE SOURCE 8

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

MA

ST

ER

SL

AV

E

1

SL

AV

E2

SL

AV

E3

CO

MM

ON

AL

E

R

T

EV

A

C

GR

OU

ND

EM

IN

dB

1 2 3 4 5 6 7 8 G

CONTACT CLOSURE

FIRE ALARM

 LINK IN

 LINK OUT

 EXTENSION LINK

dB

+

-

+

-

  INPUT  VOLT AGE SELECTOR

dB

dB

dB

dB

dB

dB

dB

dB

-

-

-

-

-

-

-

-

+

+

+

+

+

+

+

+

+ -

G

LINE 8

    MIC:5mV LINE:350mV

+ -

G

LINE 7

    MIC:5mV LINE:350mV

+ -

G

LINE 6

    MIC:5mV LINE:350mV

+ -

G

M

IC

M

IC

MI

C

MI

C

LI

N

E

LI

NE

LI

N

E

LI

NE

P

HA

NT

OM

PH

AN

TO

M

PH

AN

TO

M

PH

AN

TO

M

LINE 5

    MIC:5mV LINE:350mV

EMC

INPUT

OUTPUT

TONE

-10

+10

dB

775mV/10K

BA

TT

 S

U

PPL

Y

   

    

  

 24

V

 2A

~120V/240V  50-60Hz

120V

240V

1 2 3 4

ON

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

ZM8 MIXER

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

ZM8 MIXER

Specifications

ZM8

Line 1-4 input

195mV-2V/10kΩ

Line 5-7 input

MIC: 5mV/600Ω, Line: 350mV-3V/10kΩ, Phantom power: +48V

Microphone 1

5mV-280mV/600Ω

Remote paging station

300mV-1.1V/10kΩ

Remote control panel

300mV-1.1V/10kΩ

Tone control

100Hz (±10dB), 10kHz (±10dB)

Outputs

0.775V/600Ω

Frequency response

MIC: 80Hz-18kHz (+1/-3dB), Line: 20Hz-20kHz (+1/-3dB)

EMC inputs

775mV/10kΩ

Microphone S/N ratio

>65dB

Line S/N ratio

>85dB

Degree of seperation

>40dB

Crosstalk

>65dB

THD

<0.07%

Indicator

Power, MIC1, paging busy and monitor output

Priority

MIC1, voice alarm, local mic paging, remote zone paging, line 1-8

Communication spee

4800bps

Communication port

RJ45

Communication protocol

RS485

Power consumption

20W

Power Supply

~110V/60Hz or ~240V/50Hz & DC 24V

Dimensions (H x W x D)

132 x 484 x 304mm

Weight

6kg

Order code

CRAM19

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

5

Product overview & technical specifications

Specifications

AC power supply

AC 115-240V/50-60Hz
Voltage selector between 115V-240V

DC power supply

+24V (±4V)

Line input sensitivity

195mV-2.0V clockwise rotation gain to increase

Line input impedance

47kΩ

Local input sensitivity

500mV balanced input

Local gain

±8dB

MIC1 impedance

600Ω

MIC level control

 ±8dB Input 100Hz sine wave signal

Paging console sensitivity

500mV Input 1kHz sine wave signal and output 0.775V

Paging console gain control

±8dB

Zone output

0.775mV Balanced output

Zone gain output

±8dB

Zone output level control

±10dB Input 100Hz sine wave signal

S/N ratio

<60db Non-weighting

Isolation degree

>40dB

Channel crosstalk

>50dB

Gain deviation

<2dB

THD

0.07%

Frequency response

Line 1-8 inputs and remote source input:  
20Hz-20kHz
MIC 1 input: 80Hz-18kHz

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

6

Specifications

BW Wall Controller

Serial communication speed

4800bps

Communication port

RJ45

Communication protocol

RS485

Serial communication distance

1km maximum

MIC input sensitivity

5mV/600Ω, Phantom power: +12V

AUX input sensitivity

350mV/10KΩ

Audio output

0dB/600Ω

Frequency response

50Hz-18kHz (±1dB)

S/N ratio

MIC: >65dB, AUX: >75dB

THD

<0.1% @ 1kHz

Controls

Volume control

Power consumption

5W

Power Supply

DC 24V

Dimensions (H x W x D)

86 x 146 x 48mm

Weight

150g

Order code

CRAM19A

Dedicated wall plates for the ZM8 Zone Mixer. Installation of the plates requires simple, easy connection via 

standard RJ45 terminated CAT5 cable.  

NOTE: The ZM8 wall plates are supplied seperately to the main ZM8 system.

• Zone LED indicator with up/down buttons
• Volume controls provided
• DC 24V power supply from controller
• Metal back box supplied

• Remote line and microphone via XLR inputs with gain controls
• Source selection and  volume control

ZM8 Wall Plates

ZM8 BW Wall Plate

ON

SOURCE 

UP 

SOURCE 

LEVEL

SOURCE

DOWN

1

3

2

4

5

7

6

8

1

2

3

MIC 

2

3

4

5

0

1

6

7

8

10

  

9

LINE 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

MIC 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

LINE

INPUT

Net Interface 

1

JTAG1

24V

GN

D

GN

D

Av

+

Av

-

GN

D

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

7

Specifications

CW Wall Controller

Serial communication speed

4800bps

Communication port

RJ45

Communication protocol

RS485

Serial communication distance

1km maximum

Controls

Volume control

Power consumption

5W

Power Supply

DC 24V

Dimensions (H x W x D)

86 x 86 x 48mm

Weight

70g

Order code

CRAM19B

ZM8 CW Wall Plate

ZM8 DW Wall Plate

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

 

 

Net Interface 1

JTAG1

GND 24V

• Source selection and volume control

• Two remote microphone inputs with volume, bass, and  

treble controls

Specifications

DW Wall Controller

Serial communication speed

4800bps

Communication port

RJ45

Communication protocol

RS485

Serial communication distance

1km maximum

MIC input sensitivity

5mV/600Ω

Audio output

0dB/600Ω

Frequency response

50Hz-18kHz (±1dB)

S/N ratio

>65dB

THD

<0.1% @ 1kHz

Controls

Volume control

Power consumption

5W

Power Supply

DC 24V

Dimensions (H x W x D)

86 x 146 x 48mm

Weight

150g

Order code

CRAM19C

1

2

3

MIC1

MIC2

MUSIC

MUTE

ON

1

2

3

-

+

HF

LF

-

+

-

+

HF

LF

-

+

2

3

4

5

0

1

6

7

8

10

  

9

2

3

4

5

0

1

6

7

8

10

  

9

Net Interface 

1

24V
GND

GND
Av-

Av+
GND

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

8

Panel & connection identification

01 - Source selection button
02 - LED display
03 - Page busy indicator
04 - MIC1 priority indicator
05 - MIC1 priority button
06 - Music volume control
07 - Master volume control
08 - MIC1 volume control
09 - Monitor zone select
10 - Monitor zone LED display
11 - Monitor zone output level
12 - ENTER
13 - ESC
14 - Monitor volume control
15 - PAGE ALL
16 - BGM ALL

17 - On/off power switch
18 - Power LED
19 - Master/slave dip switches
20 - Mains fuse
21 - Power input
22 - Input voltage selector
23 - EVAC / Fire system interface
24 - Extension link
25 - Tone output
26 - EMC input
27 - Remote source
28 - Remote control input
29 - Page volume
30 - LF (bass) tone control
31 - Zone output
32 - Zone gain control

33 - HF (treble) tone control
34 - Enable/disable switch
35 - Remote source gain
36 - Fire alarm interface
37 - Line gain
38 - Line inputs
39 - Paging console inputs
40 - Paging MIC agin
41 - MIC1 input
42 - MIC1 gain
43 - MIC1 LF bass
44 - MIC1 HF treble
45 - Balanced MIC/LINE inputs
46 - Balanced input function select

13

15

17

Please note: zones 1-8 have the same control features

1

5

6

7

8

9

12

10 11

16

18

14

2

3

1

4

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

1.5V/600

    

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

LF

HF

MICROPHONE 1

GAIN

-8

+8

dB

PAGING  MIC1

PAGING  MIC2

-

+

dB

GAIN

GAIN

-

+

dB

LINE 1

LINE 2

R

L

R

L

-

+

dB

GAIN

GAIN

-

+

dB

LINE 3

LINE 4

GAIN

-

+

dB

GAIN

-

+

dB

-8

+8

dB

dB

-

+

dB

OUTPUT

    

REMOTE SOURCE 1

HF

LF

0V

0V

0V

0V

0V

0V

0V

0V

1

1

1

1

1

1

1

1

+

+

+

+

+

+

+

+

3

3

3

3

3

3

3

3

-

-

-

-

-

-

-

-

2

2

2

2

2

2

2

2

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

ZONE

    8 

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

0V

0V

0V

0V

0V

0V

0V

0V

1

1

1

1

1

1

1

1

+

+

+

+

+

+

+

+

3

3

3

3

3

3

3

3

-

-

-

-

-

-

-

-

2

2

2

2

2

2

2

2

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

ZONE

    1 

R

L

R

L

ZONE

    2 

ZONE

    3 

ZONE

    4 

ZONE

    5

ZONE

    6 

ZONE

    7 

    REMOTE SOURCE 2

    

    REMOTE SOURCE 3

    

    REMOTE SOURCE 4

    

    REMOTE SOURCE 5

    

    REMOTE SOURCE 6

 

   REMOTE SOURCE 7

    195mV-2V/47K

    195mV-2V/47K

  5mV-300mV/680

DISABLE

ENABLE

REMOTE

WALL CONTROL

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE 

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE 

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

    REMOTE SOURCE 8

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

MA

ST

ER

SL

AV

E

1

SL

AV

E2

SL

AV

E3

CO

MM

ON

AL

E

R

T

EV

A

C

GR

OU

ND

EM

IN

dB

1 2 3 4 5 6 7 8 G

CONTACT CLOSURE

FIRE ALARM

 LINK IN

 LINK OUT

 EXTENSION LINK

dB

+

-

+

-

  INPUT  VOLT AGE SELECTOR

dB

dB

dB

dB

dB

dB

dB

dB

-

-

-

-

-

-

-

-

+

+

+

+

+

+

+

+

+ -

G

LINE 8

    MIC:5mV LINE:350mV

+ -

G

LINE 7

    MIC:5mV LINE:350mV

+ -

G

LINE 6

    MIC:5mV LINE:350mV

+ -

G

M

IC

M

IC

MI

C

MI

C

LI

N

E

LI

NE

LI

N

E

LI

NE

P

HA

NT

OM

PH

AN

TO

M

PH

AN

TO

M

PH

AN

TO

M

LINE 5

    MIC:5mV LINE:350mV

EMC

INPUT

OUTPUT

TONE

-10

+10

dB

775mV/10K

BA

TT

 S

U

PPL

Y

   

    

  

 24

V

 2A

~120V/240V  50-60Hz

120V

240V

1 2 3 4

ON

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

ZM8 MIXER

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

ZM8 MIXER

19 20

22

24

25 26

27 28

29

30

31

32

33

36

37

45 46

37

39 40

41

43

42

44

38

38

37

34

35

21

23

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

1.5V/600

    

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

LF

HF

MICROPHONE 1

GAIN

-8

+8

dB

PAGING  MIC1

PAGING  MIC2

-

+

dB

GAIN

GAIN

-

+

dB

LINE 1

LINE 2

R

L

R

L

-

+

dB

GAIN

GAIN

-

+

dB

LINE 3

LINE 4

GAIN

-

+

dB

GAIN

-

+

dB

-8

+8

dB

dB

-

+

dB

OUTPUT

    

REMOTE SOURCE 1

HF

LF

0V

0V

0V

0V

0V

0V

0V

0V

1

1

1

1

1

1

1

1

+

+

+

+

+

+

+

+

3

3

3

3

3

3

3

3

-

-

-

-

-

-

-

-

2

2

2

2

2

2

2

2

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

-

+

dB

ZONE

    8 

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

HF

LF

PAGE

GAIN

-10

+10

dB

-10

+10

dB

0V

0V

0V

0V

0V

0V

0V

0V

1

1

1

1

1

1

1

1

+

+

+

+

+

+

+

+

3

3

3

3

3

3

3

3

-

-

-

-

-

-

-

-

2

2

2

2

2

2

2

2

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

dB
-

+

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

OUTPUT

    

ZONE

    1 

R

L

R

L

ZONE

    2 

ZONE

    3 

ZONE

    4 

ZONE

    5

ZONE

    6 

ZONE

    7 

    REMOTE SOURCE 2

    

    REMOTE SOURCE 3

    

    REMOTE SOURCE 4

    

    REMOTE SOURCE 5

    

    REMOTE SOURCE 6

 

   REMOTE SOURCE 7

    195mV-2V/47K

    195mV-2V/47K

  5mV-300mV/680

DISABLE

ENABLE

REMOTE

WALL CONTROL

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE 

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE 

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

DISABLE

ENABLE

REMOTE

WALL CONTROL 

    REMOTE SOURCE 8

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

300mV-1.1V/10K

MA

ST

ER

SL

AV

E

1

SL

AV

E2

SL

AV

E3

CO

MM

ON

AL

E

R

T

EV

A

C

GR

OU

ND

EM

IN

dB

1 2 3 4 5 6 7 8 G

CONTACT CLOSURE

FIRE ALARM

 LINK IN

 LINK OUT

 EXTENSION LINK

dB

+

-

+

-

  INPUT  VOLT AGE SELECTOR

dB

dB

dB

dB

dB

dB

dB

dB

-

-

-

-

-

-

-

-

+

+

+

+

+

+

+

+

+ -

G

LINE 8

    MIC:5mV LINE:350mV

+ -

G

LINE 7

    MIC:5mV LINE:350mV

+ -

G

LINE 6

    MIC:5mV LINE:350mV

+ -

G

M

IC

M

IC

MI

C

MI

C

LI

N

E

LI

NE

LI

N

E

LI

NE

P

HA

NT

OM

PH

AN

TO

M

PH

AN

TO

M

PH

AN

TO

M

LINE 5

    MIC:5mV LINE:350mV

EMC

INPUT

OUTPUT

TONE

-10

+10

dB

775mV/10K

BA

TT

 S

U

PPL

Y

   

    

  

 24

V

 2A

~120V/240V  50-60Hz

120V

240V

1 2 3 4

ON

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

1.5V/600

    

ZM8 MIXER

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

ZM8 MIXER

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

9

Layout identification

Layout identification:
1. Source select

The source select up button (1) is used to select the source for the zone. 
Each zone has a separate source selection button. There are 9 selectable 
sources: Line sources 1 through 8 and a local balanced audio source. 
A different local source (remote in wall mixer or source select/volume 
control) can be connected to each zone.  

A zone cannot select the local source connected to another zone. 
Pressing the source select button will cycle through all zones in sequence: 
1, 2, 3, 4, 5, 6, 7, 8, L, and OFF. To select the required source, press 
the source select button (1). Once the display shows the desired source, 
press the ENTER (12) button to confirm and change to the selected 
source.
 
Note:
The source will only change after the ENTER (14) button is pressed. If 
the ENTER (14) button is not pressed, the source selection will return 
to the previous setting after 10 seconds. When the system is used in 
conjunction with remote control panels, the zone source select button will 
be disabled when a remote control panel is connected to a zone.

2. Zone LED display

The zone LED display (2) will display the selected source number: lines 
1-8 and local input shown as L.

3. Page busy indicator

The zone page busy indicator LED (3) will illuminate amber to indicate a 
paging microphone is paging to this zone.

4. MIC1 priority indicator

The MIC1 priority indicator LED (4) will illuminate blue, indicating the zone 
MIC1 priority paging function is enabled.

5. MIC1 priority button

The MIC1 priority button (5) will enable/disable the MIC1 priority paging 
function. When enabled, MIC1 will override zones 1-8 and all local inputs, 
if a signal is present on the MIC1 input. When disabled, MIC1 will mix with 
lines 1-8 and local inputs if required. This microphone input has been 
designed to give global priority over all other inputs if enabled via the front 
panel. The MIC1 priority setting is not saved when the ZM8 is switched 
off, and will return to its default state when the unit is powered back on. 
The default of the MIC1 priority is disabled.

6. Music volume control

The music volume control knob (6) controls the selected source (zones 
1-8 and local input) input levels. If the system is used with remote control 
panels, the music volume control knob will be disabled for zones where 
a remote control panel is connected. Source music volume level will be 
controlled at the remote control panel only.

7. Master volume control

The master volume control know (7) will control the combined MIC1 and 
source output volume level, if the MIC1 input has been enabled for a 
zone. The master volume control knob will not control the paging console 
public address volume level (PM ZM8), or the line 8 source input volume 
level when the line 8 source input priority function is enabled. This 
function has been designed as a global BGM input if required. 

8. MIC1 volume control

The MIC1 volume control know (8) will control the MIC1 input level if this 
global mic has been configured to operate within the zone.

9. Monitor zone select

The zone select button (9) is used to select one of the 8 zones to be 
monitored. Pressing the zone select button will cycle through all zones 
in sequence as follows: 1, 2, 3, 4, 5, 6, 7, 8, and OFF. A zone can be 
selected by pressing the zone select button. Once the display shows 
the desired zone, press the ENTER button to confirm and change to the 
selected zone. 

Note:
The zone will only change after the ENTER button (12) is pressed, 
otherwise the source selection will be returned to it’s previous setting 
after 10 seconds. The monitor zone function enables the audio output 
from a zone to be monitored through a small speaker on the front panel. 
This is particularly useful when controlling the audio in a remote zone or 
testing the system. 

10. Monitor zone LED display

The monitor zone LED display (10) will display the selected zone numbers, 
1-8.

11. Monitor zone output level

The 5 LED monitor zone output level meter (11) will provide visual 
indication of the audio signal level for a selected zone.

12. ENTER

The ENTER button (12) is used to confirm selection of source select, 
monitor zone select and BGM function buttons.

13. ESC

The ESC button (13) is used to cancel the selection of source select, 
monitor zone select and BGM function buttons.

14. Monitor volume control

The monitor volume control knob (14) will control the built-in monitor 
speaker volume level.

15. PAGE ALL

The PAGE ALL button (15) is used to activate the page function for all 8 
zones simultaneously. To confirm the page all selection press the ENTER 
button (12).

16. BGM ALL

The BGM ALL button (16) is used to select the same source for all 8 
zones simultaneously. To confirm the BGM all selection press the ENTER 
button (12).

Note:
The PAGE ALL /BGM ALL selection will only be confirmed after the ENTER 
button (12) is pressed, otherwise the source selection will be returned to 
the previous setting after 10 seconds. In the event power is lost, the  
PAGE ALL/ BGM ALL selection settings will be saved and the unit will 
return the the selected settings when the unit is powered back on.

17. On/off power switch

The on/off power switch (17) is used to power the unit on/off.

18. Power LED

The Power LED (18) will illuminate blue when the unit is powered on.

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

10

Layout identification

19. Master/slave dip switches

Dip switches set the Matrix system address. If the system is to be 
expanded, each ZM8 unit must be defined as master, slave 1, 2 or 3.
If you are expanding the system, only line inputs 1-8, MIC1 and 2 remote 
paging consoles of the master Matrix are enabled. All slave Matrix units 
connected to the master will use the master Matrix inputs.
For the avoidance of doubt, if a Matrix unit is configured as a slave, the 
slave Matrix inputs 1-8, MIC1 and remote paging console inputs will be 
disabled. However, the optional wall pates can be used to operate these 
additional zones.
Dip switch settings are as follows for configuring the ZM8 as a master or 
slave.

20. Mains fuse

If the mains fuse requires replacement use the same type and value fuse 
as originally supplied.

21. Power input

22. Input voltage selector

 

23. EVAC / Fire system interface  
       (7 way Pheonic connector)

PINS 1 + 2 DC power supply input (battery backup or UPS).  
PIN 1: +24V DC, PIN 2: -24V DC.

PIN 4 - ALERT DRY CONTACT

The built-in alert voice message will  
be broadcast to all 8 zones after being  
triggered by dry contact between EVAC  
and COMMON.

PIN 5 - EVAC DRY CONTACT

The built-in EVAC voice message will be broadcast to all 8 zones after 
being triggered by dry contact between EVAC and COMMON.

PIN 6 - EMC IN

An optional external voice alarm message may be broadcast to all 8 
zones of the system, when an alarm signal is detected from an external 
voice message generator. Fire alarm, alert, EVAC, and EMC in are of 
equivalent priority.

24. Extension link (DB37 connector)

The extension link connectors enable 8 zone Matrix units to be connected 
together to form a larger system. Up to four 8 ZM8 units can be 
connected to make a 32 zone system.

The ZM8 Matrix can be linked with a DB37 cable. THis will enable the 
line 1-8 sources, MIC1 input, paging consoles 1 & 2, and communication 
data of the master unit to be shared with any slave ZM8 Matrix units 
connected to the system.

25. Tone output

The tone output volume control will adjust the output level of the Fire 
alarm, alert, and EVAC voice messaging.

26. EMC input

The EMC input volume control will adjust the  
output level of the EMC voice messaging.  
Fire alarm, alert, EVAC and EMC in are of  
equivalent priority.

27. Remote source

Each zone can have a remote line level source  
connected. The remote source input connector  
is shown here. This has been designed to be  
used if you don’t wish to use a local in wall  
mixer. This could be for example a radio MIC.  
On selecting this input via the front panel  
controls, select “L”. Please note that this input cannot be distributed to 
other zones.
Local zone source level has three adjustments, namely:
a. Gain control for the local source input  
on the rear of the Matrix.
b. A music level control on the matrix  
front panel or the remote wall control.
c. A master level control on the Matrix  
front panel.

Please note the input signal sensitivity is  
300mV - 1.1V/10kΩ.

28. Remote control input

Each of the 8 zones can have a remote control panel connected.  
The remote control panel will enable the source and volume to be 
controlled from a remote location. Each zone has it’s own RJ45 input 
connector allowing for a remote control panel to be connected for  
control over each zone.

Master Matrix

Extension Matrix 1

Extension Matrix 3

Extension Matrix 2

MA

ST

ER

SL

AV

E1

SL

A

VE

2

SL

AV

E3

MA

ST

ER

SL

AV

E1

SL

A

VE

2

SL

AV

E3

MA

ST

ER

SL

AV

E1

SL

A

VE

2

SL

AV

E3

MA

ST

ER

SL

AV

E1

SL

A

VE

2

SL

AV

E3

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

11

Local source connections are as follows:
1. A remote wall panel can be connected to the Matrix, with only one 
remote wall controller able to be connected per zone.
2. The remote wall panel will be selectable on the syetm. Therefore, 
selectable sources will be L (local) as well as source line 1-8.

ZM8 BW (CRAM19A) assignment  
order is as below:
1. RS485B
2. RS485A
3. NC
4. GND
5. DC +24V
6. DC -24V
7. AUDIO IN +
8. AUDIO OUT -

ZM8 CW (CRAM19B) assignment  
order is as below:
1. RS485B
2. RS485A
3. NC
4. GND
5. DC +24V
6. DC -24V
7. NC
8. NC

 

ZM8 DW (CRAM19C) assignment
order is as below:
1. NC
2. NC
3. MUTE
4. GND
5. DC +24V
6. DC -24V
7. AUDIO IN +
8. AUDIO IN -

29. Page

The zone page output volume control will adjust the output paging level 
for the zone. Every zone has a page output volume control which enables 
the paging level of each zone to be set independently of other zones.

30. LF (bass) tone control

The zone LF bass of the zone output  
can be controlled by adjusting the  
LF bass level control. This level control  
will provide adjustment of the 100Hz  
audio frequency by ±10dB. 

Every zone has an LF bass level control which enables the LF bass level of 
each zone to be set independently of other zones.

31. Output

Every zone has an audio output connector; this  
should be connected to the audio amplifier for the  
designated audio zone. Zone audio output  
connections are as labeled.

32. Gain

The zone gain control will set the maximum source  
output volume level for the zone. This will ensure  
the user cannot adjust the audio level too high using  
the master, MIC1, and music level control knobs on the front panel. The 
gain will set the maximum output volume of line source and MIC1. It will 
have no control over the paging level.

33. HF (treble) tone control

The zone HF treble of the zone output can be  
controlled by adjusting the HF treble level control.  
This level control will provide adjustment of the  
audio frequency by ±10dB. Every zone has a  
HF treble level control which enables the HF treble level of each zone to 
be set independently of other zones.

34. Enable/Disable switch

If a zone remote wall control panel is to be used  
with the system, the RJ45 remote control panel input 
needs to be enabled. The RJ45 remote control panel  
is enabled/disabled by pressing the Enable/Disable  
switch. Each zone has an RJ45 remote control panel  
input Enable/Disable switch. Please note: Only enable when a zone 
remote wall control panel is connected.

35. Remote source gain

The zone local source input signal level can be  
adjusted from 300mV - 1.1V using the remote 
source gain control. This will enable the signal level  
of all sources to be equalized there by ensuring  
output volume level remains constant when  
switching from one source to another source.  
Each zone remote source input has a gain control.

36. Fire alarm

There are Fire alarm dry contacts for zones 1-8. When dry contact is 
detected the EMC input will be open and take priority over all other inputs.

The EMC input will only take priority and broadcast to zones where there 
is a zone  
fire alarm dry contact closure. Each zone  
has a seperate fire alarm dry contact.  
Fire alarm, alert, EVAC and EMC in are of equivalent priority.

Layout identification

1

2

3

4

5

6

7

8

B

A

NC

GND

+24V

+24V

AUDIO IN + AUDIO IN +

1

2

3

4

5

6

7

8

NC

MUTE

GND

+24V

+24V

AUDIO IN + AUDIO IN +

1

2

3

4

5

6

7

8

B

A

NC

GND

+24V

+24V

NC

R

1

2

3

4

5

6

7

8

B

A

NC

GND

+24V

+24V

AUDIO IN + AUDIO IN +

1

2

3

4

5

6

7

8

B

A

NC

GND

+24V

+24V

NC

1

2

3

4

5

6

7

8

NC

MU T E

+24V

G ND +24V

A U DIO   I N + A U DIO  I N +

R

1

2

3

4

5

6

7

8

B

A

NC

GND

+24V

+24V

AUDIO IN + AUDIO IN +

1

2

3

4

5

6

7

8

B

A

NC

GND

+24V

+24V

NC

1

2

3

4

5

6

7

8

NC

MU T E

+24V

G ND +24V

A U DIO   I N + A U DIO  I N +

R

1

2

3

4

5

6

7

8

B

A

NC

GND

+24V

+24V

AUDIO IN + AUDIO IN +

1

2

3

4

5

6

7

8

B

A

NC

GND

+24V

+24V

NC

1

2

3

4

5

6

7

8

NC

MU T E

+24V

G ND +24V

A U DIO   I N + A U DIO  I N +

 

dB

ZONE

 

dB

ZONE

 

dB

ZONE

 

dB

ZONE

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

12

37. Line gain

The system line source input signal levels can be adjusted from  
195mV - 2V using the line source input gain control. This will enable the 
signal level of all sources to be equalized there by ensuring output volume 
level remains constant when switching from one source to another 
source.
All system source inputs L (lines 1-8) have a seperate gain control.

38. Line inputs

The system has 4 line inputs, as well as 4 inputs selectable as MIC or line 
with phantom power available.
Every line source input has a dual RCA photo connector, which will enable 
a stereo source sugnal to be connected. Note: however this is a mono 
system and a stereo input will be combined to give a mono output.

The line inputs will have an impedance  
of 47kΩ.

1. Line 1-8 source inputs will be selectable using the source select control 
on the front of the Matrix.
2. The selected source input number will be indicated on the Matrix zone 
display.
3. Any extension Matrix unit connected to the system will use sources line 
1-8 from the master Matrix.
4. Only one set of input sources for the lines 1-8 can be connected per 
system.

39. Paging console inputs

Up to two paging consoles can be 
connected to the system  
simultaneously via the two paging 
console RJ45 input ports. The 
paging consoles will have equal 
priority and will operate on a first 
come first serve basis. The RJ45 
pin assignment order is as below:

1. RS485B
2. RS485A
3. GND
4. +24V (OUT)
5. GND
6. +24V (OUT)
7. AUDIO IN +
8. AUDIO IN -

40. Paging MIC gain

The paging MIC gain control will adjust the paging MIC input signal level. 
Each paging MIC will have its own gain control. There by each paging MIC 
can be set independently of the other paging MICs.

41. MIC 1 input

The balanced MIC1 input XLR type has an impedance of 600Ω. Each zone 
has a MIC1 priority button.

Each zone has a MIC 1 priority button. When the MIC1 priority button is 
not enabled, MIC1 will be mixed with the line inputs on each zone (1-8 or 
L). When the MIC 1 priority button is enabled, MIC1 will take priority over 
all line inouts (1-8 or L) as well as the wall control panel for that zone.

MIC1 will have priority only on zones where the MIC1 priority switch is 
enabled on the front panel. Zones where the MIC1 priority switch is not 
enabled, MIC1 will mix the source selected for the zone. The MIC1 level 
will be controlled by the MIC1 level adjustment know and the master level 
adjustment knob.

The MIC1 signal will be sent to any extension Matrix connected to the 
system.

42. MIC1 gain

The MIC1 gain controls the MIC 1 range from 5mV to 300mV.

43. MIC1 LF bass

Adjust clockwise to increase or anti-clockwise to decrease the low 
frequency (bass) contour for the MIC1. Centred at 100Hz (±10dB).

44. MIC1 HF treble

Adjust clockwise to increase or anti-clockwise to decrease the high 
frequency (treble) contour for the MIC1. Centred at 100Hz (±10dB).

45. Balanced MIC/LINE inputs

46. Balanced input function select

Layout identification

 

dB

ZONE

R

1

2

3

4

5

6

7

8

B

A

NC

GND

+24V

+24V

AUDIO IN + AUDIO IN +

1

2

3

4

5

6

7

8

B

A

NC

GND

+24V

+24V

NC

1

2

3

4

5

6

7

8

NC

MU T E

+24V

G ND +24V

A U DIO   I N + A U DIO  I N +

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

13

RS 485 COMMUNICATION PROTOCOL

RS 485 Communication Protocol
Baud rate: 57600bps/S parity
Check: Odd parity check
Data 16 bytes
Accumulation: 2nd + 3rd + 4th data byte

Inquiry Data
The ZM8 sends inquiry data to 2 remote paging consoles, 8 remote wall 
panels and extension Matrix. The new data will feedback to the Matrix 
when any new data has been checked. Any extension ZM8 will only 
enquire to its own 8 remote wall panels.

Inquiry Data to Paging Console
The ZM8 sends the inquiry data to remote paging consoles in the 
following format:
AA 10 00 00 AM (accumulation)
AA: data head
10: inquiry to the paging console
00: meaningless
AM: (accumulation: 2nd + 3rd + 4th  
data byte).

Feedback Data from Paging Console
The feedback data from the remote paging console to the Matrix after got 
inquiry and ready for paging format as:
AA 11 Matrix address code zone data AM
AA: data head
11: zone pagong command

Matrix Address code
01: master matrix
02: extension matrix 1
03: extension matrix 2
04: extension matrix 3
Zone data: the zone data is in 8 bytes
0: no paging
1: paging, ie: binary system
00000011 B: zone 1 and zone 2 paging
0000100 B zone 3 paging
11111111 B: all 8 zone paging
AM: (accumulation: 2nd + 3rd + 4th data byte).

Status Data to Paging Consoles
After getting paging data from the remote paging console, the Matrix 
sends zone status data to the paging console in the following format:
hA 1 E Matrix address code zone data AM
AA: data head
1 E: zone status feedback to paging console
Matrix address code:
01: master matrix
02: extension matrix 1
03: extension matrix 2
04: extension matrix 3
Zone data: the zone data is in 8 bytes
0: no paging
1: paging, ie: binary system
00000011 B: zone 1 and zone 2 busy
0000100 B zone 3 busy
11111111 B: all 8 zone busy
AM: (accumulation: 2nd + 3rd + 4th data byte).

Layout identification

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

14

Power Supply

The remote paging console is powered by the Matrix through the RJ45 communication port when the communication distance is less than 50m. An extra DC 
24V power input is equipped on the back part of the paging consolle to supply power when the communication distance is greater  
than 50m.

Connection between Remote Paging Console and Extension Keypad

The IDE communication cable is used to provide connection between the remote paging console and the extension keypad as well as between the two 
extension keypads.

There are 4 address codes on both the remote paging console and the extension keypad which are used to identify these.

Please Note:

Only one address code switch of each dip switch can be placed in the downward position. If any of the dip switches are set at different addressed to those 
shown above, the console will not operate.

Extension keypad remote paging console connection is made through the supplied 10P IDE cable. Once either two or three ZM8 PGC extension panels are 
connected, the operation of paging announcements is the same as described previously for individual zone paging or all call actions.

Extension Keypad 1

Extension Keypad 2

Extension Keypad 3

Extension Keypag Dip Switch setting

Connection through
10 P IDE cable

Extension keypad

Remote paging console

Connections and settings

Connections and settings

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

15

Typical simple configuration

ON

SOURCE 

UP 

SOURCE 

LEVEL

SOURCE
DOWN

1

3

2

4

5

7

6

8

1

2

3

MIC 

2

3

4

5

0

1

6

7

8

10

  

9

LINE 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

MIC 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

LINE

INPUT

ON

SOURCE 

UP 

SOURCE 

LEVEL

SOURCE
DOWN

1

3

2

4

5

7

6

8

1

2

3

MIC 

2

3

4

5

0

1

6

7

8

10

  

9

LINE 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

MIC 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

LINE

INPUT

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

ZM8 CW

Fire Centre

PM ZM8

CRAM20

CRAM20

PM 400

ZM8

CRAM22

CRSP31/32

CRSP01

CRSP16

CRSP22

CRSP19

CRSP13

CRSP10

CRSP17

CRAM22

AUX Cable
CAT Cable
Speaker Cable
Fire Alarm Input

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

Zone 7

Zone 8

ZM8 BW

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

ZM8 MIXER

The ZM8 (CRAM19) is an 8 zone audio matrix and remote paging system 
which is versatile for multi-music room solutions including homes, fitness 
centres and hotels. The system is capable of broadcasting to 8 different 
zones all with different outputs. It is also possible to expand the system 
to 32 zones using 4 of the ZM8 units. The controller can connect up to 8 
remote wall plates and 2 remote paging microphones. The system uses 
CAT-5 cables for communication control as this helps for an easy and  
cost effective installation. The unit has a dual voltage 110V-230V  
and DC 24V operation.
The PM ZM8 (CRMIC07) is a remote 8 zone paging microphone for office 
admin and reception desk use. The zone paging will not interrupt the 
other zones on the system.
The PM 400 (CRMIC04) is a condenser microphone is used by firemen/
electricians  
in the control room, which have highest priority announcement in cases  
of emergency.
The SL 4120 (CRAM22) is a four channel power amplifier with 120W 
power output per channel.
The ZM8 BW (CRAM19A) is a remote wall plate with AUX/LINE input. 
The ZM8 CW (CRAM19B) is a remote wall plate. Both of them are used 
for volume control and source selection, an LED display provides direct 
visual volume level and source channel. The ZM8 BW/CW is supplied with 
mounting box.
The BGS 35T (CRSP31/32) are indoor 100V background music 
loudspeakers featuring ABS enclosures and sturdy metal grilles.  
Suitable for bookshelf or wall mounting via the adjustable fixing bracket 
supplied. The trapezoidal design allows for the enclosures to be mounted 
neatly into corners, making them ideal for installation in bars, cafés, 
hotels and offices.
The MH 50 (CRSP01) is an ideal paging and sound reinforcement horn 
loudspeaker for large open, outdoor spaces. Utilising a two-way design  
the MH 50 delivers a wider frequency range than traditional 100V  
horn loudspeakers.

A sleek ABS, wall mount cabinet loudspeaker for installation into offices, 
schools and commercial premises. Utilising a 2-way design the CSW 56 
(CRSP16) is designed for background music and voice reinforcement.
This elegant pendant ball loudspeaker, which is suitable for installation 
into venues with high ceilings offers full range audio delivered utilising a 
dual cone woofer. The PDS 615 (CRSP22) loudspeakers are ideally suited 
for general background music and speech reinforcement in supermarkets 
and warehouses.
The HS 730 (CRSP19) is a weather resistant horn loudspeaker suitable 
for paging and voice reinforcement. The high efficient design projects 
the spoken word or warning tones delivering high intelligibility across its 
frequency. Featuring ABS construction complete with metal mounting 
brackets, the sound projectors rugged build quality is ideal for installation 
into large open venues such as sports venues, car parks and warehouses.
The CS 840 HP (CRSP13) is a high powered ceiling loudspeaker with 
extended frequency response ideal for playback of music and speech 
reinforcement where audio quality is important. The CS 840 HP (CRSP13) 
utilises a coaxial design complete with HF tweeter for crystal clear high 
tones plus a metal enclosure for enhanced low frequency.
Weather resistant these IP44 rated PS 620 (CRSP17) projector speakers 
are suitable for paging and background music applications. Featuring 
an aluminium construction complete with metal grille and mounting 
brackets, the sound projectors rugged build quality is ideal for installation 
into public spaces such as sports venues, market halls, and shopping 
centres.
Cost effective these CS 69LC (CRSP10) loudspeakers offer full range 
audio delivered utilising a dual cone woofer. The loudspeakers are ideally 
suited for general background music and speech reinforcement.

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

16

Connection diagram

ON

SOURCE 

UP 

SOURCE 

LEVEL

SOURCE

DOWN

1

3

2

4

5

7

6

8

1

2

3

MIC 

2

3

4

5

0

1

6

7

8

10

  

9

LINE 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

MIC 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

LINE

INPUT

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

1

2

3

MIC1

MIC2

MUSIC

MUTE

ON

1

2

3

-

+

HF

LF

-

+

-

+

HF

LF

-

+

2

3

4

5

0

1

6

7

8

10

  

9

2

3

4

5

0

1

6

7

8

10

  

9

ON

SOURCE 

UP 

SOURCE 

LEVEL

SOURCE

DOWN

1

3

2

4

5

7

6

8

1

2

3

MIC 

2

3

4

5

0

1

6

7

8

10

  

9

LINE 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

MIC 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

LINE

INPUT

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

1

2

3

MIC1

MIC2

MUSIC

MUTE

ON

1

2

3

-

+

HF

LF

-

+

-

+

HF

LF

-

+

2

3

4

5

0

1

6

7

8

10

  

9

2

3

4

5

0

1

6

7

8

10

  

9

ON

SOURCE 

UP 

SOURCE 

LEVEL

SOURCE

DOWN

1

3

2

4

5

7

6

8

1

2

3

MIC 

2

3

4

5

0

1

6

7

8

10

  

9

LINE 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

MIC 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

LINE

INPUT

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

1

2

3

MIC1

MIC2

MUSIC

MUTE

ON

1

2

3

-

+

HF

LF

-

+

-

+

HF

LF

-

+

2

3

4

5

0

1

6

7

8

10

  

9

2

3

4

5

0

1

6

7

8

10

  

9

ON

SOURCE 

UP 

SOURCE 

LEVEL

SOURCE

DOWN

1

3

2

4

5

7

6

8

1

2

3

MIC 

2

3

4

5

0

1

6

7

8

10

  

9

LINE 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

MIC 

LEVEL

2

3

4

5

0

1

6

7

8

10

  

9

LINE

INPUT

ON

SOURCE LEVEL

 

 

1

3

2

4

5

7

6

8

2

3

4

5

0

1

6

7

8

10  

9

UP 

SOURCE

DOWN

SOURCE

1

2

3

MIC1

MIC2

MUSIC

MUTE

ON

1

2

3

-

+

HF

LF

-

+

-

+

HF

LF

-

+

2

3

4

5

0

1

6

7

8

10

  

9

2

3

4

5

0

1

6

7

8

10

  

9

ZM8 BW

ZM8 CW

ZM8 DW

Remote control panels

Master matrix 8 remote control panel

1-8 zone outputs

Line 1-8 inputs

MIC 1 input

LINK

LINK

LINK

Paging MIC

Paging MIC

P

M

 Z

M

8

ZM

P

G

C

ZM

P

G

C

P

M

 Z

M

8

ZM

P

G

C

ZM

P

G

C

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

ZM8 MIXER

ZM8 BW

ZM8 CW

ZM8 DW

Remote control panels

Extension matrix 1 - 8 remote control panel

9-16 zone outputs

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

ZM8 MIXER

ZM8 BW

ZM8 CW

ZM8 DW

Remote control panels

Extension matrix 2 - 8 remote control panel

17-24 zone outputs

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

ZM8 MIXER

ZM8 BW

ZM8 CW

ZM8 DW

Remote control panels

Extension matrix 3

25-32 zone outputs

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

PAGE  BUSY

MIC1 PR

IORITY

SOURCE  UP

SOURCE  DO

WN

MUSIC1

MASTE R1 

MUSIC2

MASTE R2 

MIC2

MUSIC3

MASTE R3 

MIC3

MUSIC4

MASTE R4 

MIC4

MUSIC5

MASTE R5 

MIC5

MUSIC6

MASTE R6 

MIC6

MUSIC7

MASTE R7 

MIC7

MUSIC8

MASTE R8 

MIC8

MIC1

MONITO R

ZONE 1

ZONE 8

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

POWER

OFF

ON

ZONE SELECT

OUTPUT  LEVEL

2

3

4

5

0

1

6

7

8

10  

9

FUNCTION

PAGE  ALL

ENTER

BGM  AL

L

ESC

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

10  

9

3

4

5

0

1

6

7

2

2

2

8

8

8

10  

9

EMERGENC

Y

ZM8 MIXER

 


background image

www.cleveracoustics.co.uk

ZM8 Matrix Zone System

  

User Manual

17

WEEE notice

Correct Disposal of this Product 
(Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries  
with separate collection systems)

This marking shown on the product or its literature, indicates that it should not be disposed  
with other household wastes at the end of its working life. To prevent possible harm to the  
environment or human health from uncontrolled waste disposal, please separate this from other 
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their 
local government office, for details of where and how they can take this item for environmentally 
safe recycling.

Business users should contact their supplier and check the terms and conditions of the  
purchase contract. This product should not be mixed with other commercial wastes for disposal.