PDF User Manual

  1. Home
  2. Manuals
  3. Cleveland SteamCub 1SCE Operator's Manual

Cleveland SteamCub 1SCE Operator's Manual

Made by: Cleveland
Type: Operator's Manual
Category: Electric Steamer
Pages: 11
Size: 2.78 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

Operators Manual

Installation, Operation, Use & Care

SteamCub

®

  

Model 1SCE

1333 East 179

th

 Street

Cleveland Ohio 44110

Phone: 1-216-481-4900

Fax: 1-216-481-3782

 


background image

              

Cleveland Range, Inc.

         

1333 East 179

th

 St., Cleveland Ohio, U.S.A. 44110

    Ph: 1-216-481-4900  Fx: 1-216-481-3782

        Visit our Web Site at  

www.clevelandrange.com

SteamCub

®

: Operators Manual

Table of Contents

I. Warranty

.………………………………….……………………..1

II. Product 

Information

……………….…………………………2

III. General Specifications

……………………………...…..……..3

IV. Installation Requirements

………….…….…………….…….4

V. Operating 

Controls

……….…..……..………………….…...…5

VI.  Start-Up, Operation Instructions

Shutdown Instructions, Daily Maintenance

……………6-7

VII. Cooking Guidelines

…………………………………………...8

 


background image

              

Cleveland Range, Inc.

         

1333 East 179

th

 St., Cleveland Ohio, U.S.A. 44110

    Ph: 1-216-481-4900  Fx: 1-216-481-3782

        Visit our Web Site at  

www.clevelandrange.com

I

SteamCub

®

Limited Warranty

CLEVELAND RANGE products are warranted to the original purchaser to be free from defects in materials and workmanship
under normal use and service for the standard warranty period of one year from date of installation or 18 moths from date of
shipment.

CLEVELAND RANGE agrees to repair or replace, at its option, f.o.b. factory, any part which proves to be defective due

to defects in material or workmanship during the warranty period, providing the equipment has been unaltered, and has
been PROPERLY INSTALLED, MAINTAINED, AND OPERATED IN ACCORDANCE WITH THE CLEVELAND RANGE
OWNER’S MANUAL.

CLEVELAND RANGE agrees to pay any FACTORY AUTHORIZED EQUIPMENT SERVICE AGENCY (within the

continental United States, and Hawaii) for reasonable labor required to repair or replace, at our option, f.o.b. factory, any
part which proves to be defective due to defects in material or workmanship, during the labor warranty period.  This
warranty includes travel time not to exceed two hours and mileage not to exceed 50 miles (100 miles round-trip), BUT
DOES NOT INCLUDE POST START-UP, TIGHTING LOOSE FITTINGS, MINOR ADJUSTMENTS, MAINTENANCE,
CLEANING OR DESCALING.

The standard labor warranty allows factory payments of reasonable labor required or replace such defective parts.

Cleveland Range will not reimburse the expense of labor required to repair or replacement of parts after the standard
warranty period, unless and Extended Labor Warranty Contract has been purchased to cover the equipment for the balance
of the warranty period from the date of equipment installation, start-up, or demonstration.

PROPER INSTALLATION IS THE RESPONSIBILITY OF THE DEALER, THE OWNER-USER, OR INSTALLING

CONTRACTOR, AND IS NOT COVERED UNDER THIS WARRANTY.  Many local codes exist, and it is the responsibility of
the owner and installer to comply with these codes.  Cleveland Range equipment is built to comply with applicable standards
for manufactures, including UL, A.G.A., NSF, ASME/Ntl. Bd., CSA, CGA, ETL, and others.

BOILER (Steam Generator) MAINTENANCE IS THE RESPONSIBILITY OF THE OWNER-USER AND IS NOT

COVERED BE THIS WARRANTY.  The use of good quality feed water is the responsibility of the Owner-User (see Water
Quality Requirements below).  THE USE OF POOR QUALITY FEED WATER WILL VOID EQUIPMENT WARRANTIES.
Boiler maintenance supplies, including boiler hand gaskets, are not warranted beyond the first 90 days after the date the
equipment is placed into service.  Preventive maintenance records must be available showing descaling every 90-120 days
for Boiler Proration Program consideration.

WATER QUALITY REQUIREMENTS

TOTAL DISSOLVED SOLIDS less than  60 parts per million
TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

CHLORIDE

less than 30 parts per million

PH FACTOR

greater than

7.5

The foregoing shall constitute the sole and exclusive remedy of original purchaser and the full liability of Cleveland

Range for any breach of warranty.  THE FOREGOING IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
WHETHER WRITTEN, ORAL, OR IMPLIED, INCLUDING ANY WARRANTY OF PERFORMAMCE, MERCHANTABILITY,
OR FITNESS FOR PURPOSE, AND SUPERSEDES AND EXCLUDES ANY ORAL WARRANTIES OR REPRESENATIONS,
OR WRITTEN WARRANTIES OR REPRESENTATIONS, NOT EXPRESSLY DESIGNATED IN WRITING AS A
“WARRANTY” OR “GUARANTEE OF CLEVELAND RANGE MADE OR IMPLIED IN ANY MANUAL, LITERATURE,
ADVERTISING BROCHURE OR OTHER MATERIALS.

CLEVLAND RANGE’S liability on any claim of any kind, including negligence, with respect to the goods or services

covered hereunder, shall in no case exceed the price of the goods or services, or part thereof, which gives rise to the claim.
IN NO EVENT SHALL CLEVELAND RANGE BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMGES,
OR ANY DAMAGES IN THE NATURE OF PENALTIES.
LIMITED EXTENDED WARRNTY COVERAGE

LIMITED EXTENDED WARRANTY COVERAGE

The purchase for a Limited Extended Warranty Contract extends the standard warranty coverage to the purchased

period of time (one to two years) from the date of installation, start-up, or demonstration, whichever is sooner.

An additional two years Parts and Labor Warranty can be purchased with each piece of Cleveland equipment for an

additional 2% of the List Price per year.  The 2% of list price charge will be the net invoice amount for each year of extended
warranty purchased.

 

Extended warranty must be purchased at the same time the equipment is purchased.

 

Extended Warranty has the same exclusions as stated in our standard warranty.

 


background image

              

Cleveland Range, Inc.

         

1333 East 179

th

 St., Cleveland Ohio, U.S.A. 44110

    Ph: 1-216-481-4900  Fx: 1-216-481-3782

        Visit our Web Site at  

www.clevelandrange.com

II. SteamCub

®

Product Information

Removable Side Panel

Operating Controls

Main Power ON/OFF

Serial Number/Model
Number Identification

Drain Valve

6” (152mm) Stainless Steel

Adjustable Legs with skid

resistant flanged feet

Drain Pan Guides

Condensate Vent

Time/Temp. Display

“Heat-On” Indicator Light

 


background image

                  

Cleveland Range, Inc.

         

1333 East 179

th

 St., Cleveland Ohio, U.S.A. 44110

    Ph: 1-216-481-4900  Fx: 1-216-481-3782

        Visit our Web Site at  

www.clevelandrange.com

S

S

t

t

e

e

a

a

m

m

C

C

u

u

b

b

 

 

®

Steam Cooker and Holding Cabinet

General Specifications:

n

n

n

n

 

Boilerless steam cooker and holding cabinet,

compartment door can be opened anytime

during cooking.

n

n

n

n

 

Three Versatile Operating Modes:

 

Steam and Hold

 

Hold Only: Preset at 160

°

F. (71

°

C.)

 

Constant Steaming

n

n

n

n

 

Programmable Preheat and Hold Cycle
Temperature Controls with Compensating
Thermostat.

 

Timer settings for 10 minute, 1 minute

   or 10 second intervals.

 

Digital Time-Temperature and Low Water

   Indicator Display.

n

n

n

n

 

Capacity: Full Size Steam Table Pans:

 

Five:  2 ½” x 12” x 20” (1/1 GN, 65mm)

 

Ten:  1” x 12” x 20”  (1/1GN, 40mm)

n

n

n

n

 

Easy installation, no drain line, water

connections or hood is needed.

n

n

n

n

 

All 14 Gauge Stainless Steel Cooking
Compartment.

n

n

n

n

 

6”  (152mm) Skid Resistant Stainless Steel
Adjustable Legs with Flanged Feet.

n

n

n

n

 

14 Gauge Stainless Steel Two Piece

Compartment Door for an airtight, leak-proof

seal.

n

n

n

n

 

Easy to remove 9 kW Heating Element cast in
aluminum bocks.

n

n

n

n

 

Electronic Low-Water Shut-Off Safety

Indicator, High Temperature Safety Shut-Off

and LED “Heat On” Indicator Light.

n

n

n

n

 

Separate Power ON/OFF Control includes an
Automatic Pre-Heat when power is turned
“ON”.

n

n

n

n

 

Easy-Access Manual Drain Valve located in
front, Pan Slide Guides located under unit to fit
12” x 20” (1/1GN) Pans. Includes  one 4” x 12”
x 20” stainless steel pan. (1/1GN-102mm)

n

n

n

n

 

Standard Voltage: 208 Volt, 60 Hz., 3 phase.
Approvals: UL NSF

Options & Accessories:

G

 

Equipment Stand Model ES21301S

G

 

Optional Voltages, 240 Volt, 480 Volt, 3, Phase.

G

 

6 kW Heating Element.

G

 

Single Phase Operation.

Model Number

               

 

1SCE

 


background image

              

Cleveland Range, Inc.

         

1333 East 179

th

 St., Cleveland Ohio, U.S.A. 44110

    Ph: 1-216-481-4900  Fx: 1-216-481-3782

        Visit our Web Site at  

www.clevelandrange.com

IV. SteamCub

®

Installation Requirements

Electrical Requirements:

WATTS

VOLTS

PHASE

WIRES

CYCLE

AMPS

SUPPLY CONNECTION

HEATER RATED

HERTZ

WIRE SIZE (COPPER)

VOLTAGE

6000

208

3

3

60

17

12

208

5040

220

3

3

60

14

14

240

6000

240

3

3

60

15

14

240

5040

440

3

3

60

7

14

480

6000

480

3

3

60

8

14

480

9000

208

3

3

60

26

10

208

7560

220

3

3

60

20

12

240

9000

240

3

3

60

22

10

240

7560

440

3

3

60

10

14

480

9000

480

3

3

60

11

14

480

WATTS

VOLTS

PHASE

WIRES

CYCLE

AMPS

SUPPLY CONNECTION

HEATER RATED

HERTZ

WIRE SIZE (COPPER)

VOLTAGE

6000

208

1

2

60

29

8

208

5040

220

1

2

60

23

10

240

6000

240

1

2

60

25

10

240

N/A

440

N/A

N/A

N/A

N/A

N/A

N/A

6000

480

N/A

N/A

N/A

N/A

N/A

N/A

9000

208

1

2

60

44

6

208

7560

220

1

2

60

35

8

240

9000

240

1

2

60

38

8

240

N/A

440

N/A

N/A

N/A

N/A

N/A

N/A

9000

480

N/A

N/A

N/A

N/A

N/A

N/A

 For supply connection use only copper wire suitable for at least 75° C (167° F).

 


background image

              

Cleveland Range, Inc.

         

1333 East 179

th

 St., Cleveland Ohio, U.S.A. 44110

    Ph: 1-216-481-4900  Fx: 1-216-481-3782

        Visit our Web Site at  

www.clevelandrange.com

Installation

Wiring Diagram

 


background image

              

Cleveland Range, Inc.

         

1333 East 179

th

 St., Cleveland Ohio, U.S.A. 44110

    Ph: 1-216-481-4900  Fx: 1-216-481-3782

        Visit our Web Site at  

www.clevelandrange.com

V. SteamCub

®

Operating Controls

Heat-On LED Indicator:

 Elements

are on when illuminated

Time/Temperature Display

Time Set Controls: 

10 minute, 1

minute or 10 second increments

Cooking Mode Operation:

Constant Steam: 

Continuous steaming

Steam/Hold:

 Steam cooking mode

followed by a holding mode after steam
mode timer is completed

Hold Only:

 Hold Cycle mode only

Start:

 Cooking Cycle Start Button

Temp. Display:

 Compartment Temperature Display

Stop:

 Cooking Cycle Stop Button

Main Power ON/OFF Switch

Serial Number/Model Number Display

IMPORTANT OPERATION INFORMATION

Constant Steam Mode:

 Continuous steaming, not necessary to use the timer. Display will read 

”cont”

when using this mode. Cooking temperature is pre-set.

Steam & Hold Mode:

 Steam cooking using the timer settings, after the timer has counted down, unit will

automatically go into the “Hold Mode”. Steaming and Holding cycle temperatures are pre-set.

*** Note: the “10 Sec. Digit” will continuously count-down until cooking temperature is reached (during

defrosting cycle), then the timers begins to count-down cycle.

Hold Mode:

Continuous holding cycle, temperature pre-set at 160

°

F. (71

°

C.) Not necessary to use the

timer. Display will read 

“hold” 

when using this mode.

 ***Hold down push buttons for 3 seconds when stopping or changing cooking modes.

 


background image

              

Cleveland Range, Inc.

         

1333 East 179

th

 St., Cleveland Ohio, U.S.A. 44110

    Ph: 1-216-481-4900  Fx: 1-216-481-3782

        Visit our Web Site at  

www.clevelandrange.com

VI. SteamCub

®

Start Up, Operation, Maintenance Instructions

Start Up Instructions:

1.  Make sure the unit is level before start-up and operation.
2.  Open compartment door and pour 1.5 gallons (5.7 liters) of fresh water into bottom

of the cooking compartment.

  Make sure drain valve is closed.

3.  Turn main power switch “ON”.

  When power is turned “ON”, unit will automatically preheat and then go into

the “Steam & Hold “ mode when temperature is reached (about 10 minutes).

  Display will read “Cool” until preheat temperature is reached (205

°

F-96°C)

  “Heat-On” LED indicator will illuminate when the heating elements are

activated.

4.

  Allow to preheat for 10 minutes. Unit is now ready for operation.

* Note; only use the timer when in the “Steam & Hold”  Mode.

Operation Instructions:

1.  Select desired cooking mode.

  “Constant Steam”-Continuous steaming,  

no timer setting

 necessary.

Display will signal “Cont” when using this mode.

  “Steam & Hold”

  Set desired cooking time. (Steam & Hold Only)

  10 minute, 1 minute or 10 seconds intervals

  Push the “Start” button to begin operation.

*Note: Hold the push buttons for 3 seconds when starting, stopping or changing
cooking modes and times.

  “Hold Only” – Preset holding temperature at 160

°

F,  71

°

C. Display will signal

      “Hold” when using this mode. No timer setting necessary

* Low Water Indicator: 

The Display will flash “add H2O” followed by a loud

continuous beep. Add enough water without overflowing over the front of the
compartment.

 


background image

              

Cleveland Range, Inc.

         

1333 East 179

th

 St., Cleveland Ohio, U.S.A. 44110

    Ph: 1-216-481-4900  Fx: 1-216-481-3782

        Visit our Web Site at  

www.clevelandrange.com

Re-Programming the Cooking-Preheat Temperature:

The “Preheat or “Cooking” temperature is preset at the factory for 205°F., 96°C.
Changing the “Preheat and “Cooking temperature should be done by a qualified
technician.

1.  Pressing and holding the “DISPLAY TEMP” and “CONSTANT STEAM” buttons

for 3 seconds will display a flashing cook temperature. Use the “TIME” setting
increment and decrement buttons to set a new temperature. If there is no change
for 5 seconds, the current input, if it is within range, it will disregard and the
control will revert to its previous setting.

Re-Programming the Holding Temperature:

The “Holding” Temperature is preset at the factory for 160

°

F., 71°C. Changing the

“Holding” temperature should be done by a qualified technician.

1. Pressing and holding the “DISPLAY TEMP” and “HOLD” buttons for 3 seconds

will display a flashing cook temperature. Use the “TIME” setting increment and
decrement buttons to set a new temperature. If there is no change for 5 seconds,
the current input, if it is within range, it will disregard and the control will revert to
its previous setting.

* NOTE: All Temperature settings are factory preset in degrees Fahrenheit. A jumper
has been installed on the Temperature Control Board for degrees Celsius. A qualified
Cleveland technician should change degrees F. to C.

Shut-Down Instructions:

1.  Turn main power switch “OFF”
2.   Insert one 4” x 12” x 24” solid stainless steel steam table pan into pan rack guides

located under the drain valve handle.

3.  Empty water in bottom of cooking compartment by turning the drain handle to the

upright position.

  Note: The water in the bottom of the compartment will be hot. Allow the unit to

Cool Down” before draining

4.

  Close the drain valve when the compartment is empty.

Daily Maintenance Instructions:

1.

  Wipe compartment interior with clean towel

2.

  Leave compartment door open when not in use.

 


background image

              

Cleveland Range, Inc.

         

1333 East 179

th

 St., Cleveland Ohio, U.S.A. 44110

    Ph: 1-216-481-4900  Fx: 1-216-481-3782

        Visit our Web Site at  

www.clevelandrange.com

VII: 

SteamCub

®  

Cooking Guidelines

Steam cooking is an excellent way to prepare countless foods. You will find cooking to
be efficient, economical, fast and convenient. It is not necessary to add water to the
product. For best results, use a 1” or 2.5” perforated steam table pan and cook
uncovered. Liquid products must be cooked in solid pans.

Sample Cooking Times:

Food item                   # Pans          Amt. per Pan    

Min. Steamed

Whole Idaho Potatoes       1               

16 each   

45

                                          3                          

50

Frozen Broccoli Spears      1                 7.5 lbs.

15

3 22

Frozen Mixed Vegetables 5

7.5 lbs. 

24

Frozen Mac & Cheese        1                 6 lbs.                     

40

                                          5                                                

50

Rice                                  1                  3 lbs. + water         

25

Spaghetti, cooked            1                  3 lbs. uncooked , reheat from 38

°

F 6

Refried beans                   1                  2, 7 lb. cans reheat from 38

°

F

48

3 55

Scrambled eggs             

1                  3 qts whole eggs    

11

3 18

Frozen shrimp                    3                  2.5 lbs.      

10

Cake, chocolate               1          

5 lbs. mix + water                           

30