Statement of Responsibilities

This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service
Representatives who are familiar with both the safety procedures, and equipment they service.

Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage
resulting from use of, improper use of, or failure to use the information contained in this document. 

Cleveland Range, LLC has made every effort to provide accurate information in this document, but
cannot guarantee that this document does not contain unintentional errors and omissions.

The information in this document may be subject to technical and technological changes, revisions, or
updates.

Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or
updates.

Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry
standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out /
tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas,
electric, and steam powered equipment and / or appliances

All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of
operation according to OSHA approved practices during any servicing of Cleveland Range equipment

Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date
knowledge, skills, materials and equipment.

 


background image

Cleveland Range, LLC

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110

Ph: 1-216-481-4900 Fx: 1-216-481-3782 Visit our Web Site at 

www.clevelandrange.com

 


background image

CLEVELAND RANGE 

SEQUENCE OF OPERATIONS

Steam Coil Boiler Base

1. To turn the unit on, depress the red on/off rocker switch.

x

115 VAC is sent to the upper cabinets and terminal block in control box.

x

115 VAC is sent to normally open drain valve closing it.

x

115 VAC is sent to L1 and L2 of the water level board.

2. With the water level board energized and no water in the boiler 

x

115 VAC is sent from the WF terminal to the fill solenoid.

x

The fill solenoid opens and the boiler fills through the drain valve.

x

The water fills to the low probe shorting it to ground

x

115 VAC is sent from the HTR terminal through the normally closed contacts of the
highlimit pressure switch to contacts of the ice cube relay and the amber reset switch,
energizing the amber light.

3. When the momentary amber switch is depressed 115 VAC is sent to the coil of the ice cube

relay closing it.

x

The relay latches itself through a jumper to the coil.

x

If either the high-pressure switch or the low water cut off float switch opens, the
latch circuit opens.

x

When the contacts close the amber light will energize and the process may begin
again.

x

The relay contacts close sending 115 VAC through the normally closed contacts of the
operating pressure switch to the coil of the supply steam solenoid. .

4. With 115 VAC to the coil of the supply steam solenoid.

x

The solenoid opens.

x

Steam is sent to the coil in the boiler.

5. The water in the boiler is heated to steam. 

x

As steam is generated and pressure builds the air is pushed out through the steamtrap.

x

When steam goes through the steam trap and heats it to 192 degrees it closes.

6. Pressure builds in the boiler to the set point .

x

The operating pressure switch opens and the heat circuit is de-energized.

x

When the pressure drops below the set point the heat circuit is energized and the heat
process begins again.

7. Water continues to fill until the high probe is grounded.

x

When the high probe is grounded the WF terminal on the water level board is de-
energized.

x

The fill solenoid closes until the high probe is ungrounded for 05 seconds.

 


background image

x

If the water level drops below the high probe for more than 20 seconds the WF
terminal is energized and the water fill circuit begins again.

8.  When the unit is turned off, by depressing the red rocker switch, 

x

115 VAC is removed from the heat circuit.

x

115 VAC is removed from the drain circuit and the normally open drain valve opens
allowing the unit to drain.

x

115 VAC is sent to the 3-minute timer.

x

The three-minute timer will energize the fill solenoid for 3 minutes while the steamer
drains.

 


background image

 


background image

CLEVELAND RANGE

SEQUENCE OF OPERATIONS

Steam Coil Boiler Base

With Secondary Low Water Cut Off Switch

1. To turn the unit on, depress the red on/off rocker switch.

x

115 VAC is sent to the upper cabinets and terminal block in control box.

x

115 VAC is sent to normally open drain valve closing it.

x

115 VAC is sent to L1 and L2 of the water level board.

x

115 VAC is sent to the open contacts of the low water cut-off float switch.

2. With the water level board energized and no water in the boiler 

x

115 VAC is sent from the WF terminal to the fill solenoid.

x

The fill solenoid opens and the boiler fills through the drain valve.

x

The water fills to the low probe shorting it to ground

x

115 VAC is sent from the HTR terminal through the normally closed contacts of the
operating pressure switch to coil of the contactor(s).

x

The rising water also raises the float on the low water cut-off switch closing it.

x

115 VAC is sent through the normally closed contact of the high-pressure switch to the
amber reset switch, energizing the amber light.

3. When the momentary amber switch is depressed 115 VAC is sent to the ice cube relay

closing it.

x

The relay latches itself through a jumper to the coil.

x

If either the high-pressure switch or the low water cut off switch opens, the latch
circuit opens.

x

When the contact close the amber light will energize and the process may begin
again.

x

The relay contacts close sending 115 VAC to the coil of the supply steam solenoid.

4. With 115 VAC to the coil of the supply steam solenoid

x

The steam solenoid opens.

x

Supply steam is sent through the steam coil.

5. The water in the boiler is heated to steam. 

x

As steam is generated and pressure builds the air is pushed out through the steamtrap.

x

When steam goes through the steam trap and heats it to 192 degrees it closes.

6. Pressure builds in the boiler to the set point .

x

The operating pressure switch opens and the heat circuit is de-energized.

x

When the pressure drops below the set point the heat circuit is energized and the heat
process begins again.

7. Water continues to fill until the high probe is grounded.

 


background image

x

When the high probe is grounded the WF terminal on the water level board is de-
energized.

x

The fill solenoid closes until the high probe is ungrounded for 05 seconds.

x

If the water level drops below the high probe for more than 20 seconds the WF
terminal is energized and the water fill circuit begins again.

8.  When the unit is turned off, by depressing the red rocker switch, 

x

115 VAC is removed from the heat circuit.

x

115 VAC is removed from the drain circuit and the normally open drain valve opens
allowing the unit to drain.

x

115 VAC is sent to the 3-minute timer.

x

The three-minute timer will energize the fill solenoid for 3 minutes while the steamer
drains.

 


background image

 


background image

Replace the

 on/off rocker

switch

Yes

Connect power

to steamer.

No

Is the red light on

in the power

switch?

Is there power to

the steamer?

Is there water in

the sight glass?

Yes

See

Steamer won't

fill.

No

PROBLEM:

Steam Coil Boiler

won't build

pressure

No

Boiler won't build

pressure

Is the Amber light

on in the reset

switch?

Is there 120 VAC

between

terminals L2 and

HTR on the water

board?

Is there 120 VAC

between terminals

L2 and HTR on the

water board with a

jumper between

Low and C?

Is there 120 VAC

to terminal 6 on

the latching relay?

Repair

 or Replace the

probe circuit.

Replace the
water board

Replace the

Reset switch

Yes

After depressing
the reset switch,

does the Amber

light go off?

Does this boiler

have the optional

Secondary  Low

Water Cut Out?

With the High

Limit pressure

switch

temporarily

bypassed, does

the Amber light go

off when the reset

switch is

depressed?

Yes

No

No

Yes

No

Replace

 the high limit

pressure

 switch

With the SLW CO

switch

temporarily

bypassed, does

the Amber light go

off with the reset

switch depressed?

No

Yes

Yes

Replace the

SLWCO switch

With a jumper

from terminal 5 to

9 on the latching

relay, does the

Amber light go out

with the reset

switch depressed?

No

No

Replace the

latching relay.

Yes

Yes

Is there 120 VAC

to the coil of the

steam solenoid?

No

Yes

Replace the

latching relay

No

Yes

Is there 120 VAC

to the coilof the
steam solenoid

with the operating

pressure switch

temporarily

bypassed?

No

Replace the

latching relay

Replace

 the operating

pressure

switch

Does the Steam

solenoid open?

Yes

Is there an steam

at the steam coil?

Yes

With

Elements heating

the water, the

Boiler is making

steam.  Check for

leaks.

Is there a lot of

steam coming out

the drain?

Replace the

steam trap for

the boiler.

No

Supply steam

to the steamer.

No

Replace the

steam solenoid

No

No

Yes

Yes

Is the steam trap

for Incoming

steam opening to

remove air and

water from coil?

Yes

Yes

Yes

Replace the

steam trap for

the coil

No

 


background image

Boiler

won't fill.

Yes

No

No

Yes

No

Yes

Yes

No

No

Yes

No

Yes

Yes

No

No

Yes

No

No

Yes

Yes

Yes

No

PROBLEM:

Steam Coil

Boiler won't fill

Yes

Is there power to

the steamer?

Is there water to

the steamer?

Supply power

to the steamer.

Supply cold
water to the

steamer.

Replace the

on/off rocker

switch .

Is there 120 VAC

between the L1

and L2 on the

water board?

Is there

 120 VAC between

L2 and W F on the

water board?

Replace the

wiring to the fill

solenoid.

Is there

120 VAC across
the coil of the fill

solenoid?

Replace the fill

solenoid

Yes

Is

 water leaving the

fill solenoid?

Replace wiring

to drain

solenoid.

Does

 the steamer have

the optional

intermittent

blowdown timer?

Replace the
wiring to the

intermittent

blowdown

timer .

Is

there 120 VAC

between terminals

2&3 on the timer?

Replace the

intermittent

blowdown

timer.

Is there

 120 VAC across

the coil of the

drain valve?

Is water draining

from the

generator?

If water

 is leaving the fill
solenoid and not

draining from the

generator where is it

going? check  for

leaks..

Remove

 the wire from the HI

terminal on the water

board. Is there 120

VAC between L2 and

WF?

Replace the
water board

Is there

 debris on the HI

probe extension?

Replace the

wire to the Hi

probe.

Clean or

replace the

probes

extension.

Replace the

drain valve.

No

 


background image

PROBLEM:

Steam Coil

Boiler Over

Pressurizes

(15# Safety

valve opens)

Boiler over

pressurizes

Does operating

pressure switch

open at proper

setting (check

service manual for

that steamer)?

Replace

operating

pressure

switch

No

Does the steam

solenoid stay open

with operating

pressure switch

open?

Yes

Replace steam

solenoid

Does the pressure

in the gauge

continue to rise

with no voltage to

contactor coil?

No

Replace the

weeper valve.

Does the 15#

safety valve open

with little or no

pressure on the

gauge after it has

been replaced?

No

Replace the

safety valve.

No

Scale is blocking the

plumbing to the gauge.

Delime the boiler.

PROBLEM:

Steam Coil Boiler Stops Producing Steam

Boiler stops

steaming

Does the amber
light in the reset

switch  come on?

Is the temperature

sensitive dot

(surrounded by a

yellow circle) on

the water board

white?

Replace

 the water board.  It has

reached a temperature of

over 180
degrees.

Yes

No

No

Does boiler have

the optional

Secondary Low

Water Cut Out?

Yes

Are the probes

covered with

scale?

No

Delime boiler

Is high pressure

switch opening

prematurely?

Replace high

pressure switch

Replace the

water board

Yes

No

Yes

No

Will Boiler stop

making steam

with SLW CO

temporarily

bypassed?

Yes

Yes

Does SLW CO

open and close as

float is moved up

and down?

No

Install delay

timer for
SLWCO

Yes

Replace

Secondary Low

Water Cut Out

switch.

No

Yes

Replace

operating

pressure

switch.

Does steam coil

leak?

Yes

Yes

Replace steam

coil

Yes

No

 


background image

PROBLEM:  Steam Coil Boiler Overfills

Boiler over fills

With the HI probe

emersed in water
is there 120 VAC

between terminals

L2 and W F on the

water board.?

Replace the fill

solenoid

With a jumper

across terminals

HI and C on the

waterboard,  is
there 120 VAC

between L2 and

WF?

Replace ;the

water board

Yes

The probe

 circuit is open.

Check continuity of the

probe wire and

 probe.

No

No

With the wire

removed from

terminal 1on the 3

minute timer, is

there 120 VAC to

the fill solenoid?

Yes

Yes

Replace 3

minute timer

No