W
ARRANTY
The device supplied to the buyer and/or the recipient is guaranteed by CLEODE against any
malfunctions originating from a design and/or manufacturing flaw, for a period of twelve (12)
months following delivery. The buyer and/or recipient is (are) responsible for proving the
existence of the said defects or flaws. This warranty is applicable in accordance with articles
1641 to 1648 of the French Civil Code and in compliance with the French statutory warranty.
The warranty covers the replacement free of charge of devices and parts affected by a design
and/or manufacturing flaw excluding conspicuous defects in the device that are covered by
the buyer and/or the recipient.
In order to invoke the warranty, the buyer must immediately send written notice to CLEODE
of the flaws that it attributes to the device. It must enable CLEODE to have access to the
device to observe these defects and repair them. The warranty provided by CLEODE is
strictly limited to the equipment provided and shall only have for effect the replacement or
repair, at CLEODE’s expense, on its own premises, of all devices or parts that are not
functioning as a result of defects or flaws. CLEODE reserves the right to modify the devices
in order to comply with the warranty.
The warranty does not apply to replacement or repairs that may result from normal wear and
tear of devices, systems or products, damage or accidents resulting from negligence, failure to
supervise or maintain, or incorrect use of the devices, systems and/or products.
The maintenance service is provided by CLEODE with all reasonable care possible and in
compliance with the current state of the arts.
The exchange of parts or repairs performed under the warranty cannot result in extending the
length of the warranty. In no event can the unavailability of the device due to servicing give
rise to compensation for any reason whatsoever. The seller is released from all obligations
relating to the warranty if the product or device has been modified without prior written
consent, or if original parts have been replaced by parts which it has not manufactured
without prior consent. If unforeseen damage is caused by the device, it is expressly agreed
that the seller can only be liable for the reimbursement of monies received for the purchase of
the device if it has been destroyed. Under no circumstances can the seller be held liable for
indirect or contingent damage. The seller is released from any liability and the buyer waives
any rights against it if an accident or direct or indirect damage is caused to the buyer
following a defect, incorrect usage, incorrect maintenance or normal wear of the device sold.

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 3 sur 14
T
ABLE OF CONTENT
WARRANTY ......................................................................................................................................... 2
REFERENCE DOCUMENTS ............................................................................................................. 6
I
INTRODUCTION ........................................................................................................................... 7
I.1
ZPLUG
P
RESENTATION
............................................................................................................... 7
I.2
C
OPYRIGHT
................................................................................................................................... 7
II
ZPLUG DESCRIPTION ............................................................................................................... 8
II.1
Z
IG
B
EE PRESENTATION
.............................................................................................................. 8
II.2
DESCRIPTION
OF
THE
AVAILABLE
INFORMATION .................................................... 8
II.2.1
D
ESCRIPTION OF THE APPLICATION
............................................................................................ 8
II.2.2
CLUSTERS DESCRIPTION
.............................................................................................................. 9
III
INSTALLATION AND WORKING ........................................................................................ 11
III.1
I
NSTALLATION
.......................................................................................................................... 11
III.2
W
ORKING
................................................................................................................................. 11
III.2.1
O
N
/O
FF SWITCHING
................................................................................................................. 11
III.2.2
R
ESET
ZPLUG ........................................................................................................................ 11
III.2.3
S
CAN OF THE NETWORK
.......................................................................................................... 11
IV
TECHNICAL FEATURES ........................................................................................................ 12
REPAIR AND MAINTENANCE ...................................................................................................... 13

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 4 sur 14
L
IST OF FIGURES
Figure 1 : ZPLUG presentation .................................................................................................. 7

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 5 sur 14
T
ABLE OF REVISIONS
Version
Authors(s)
Version description
Date
0.1
CLEODE
Initial version
03/09/2009
1.0
CLEODE
Validated document
08/09/2009
1.1
CLEODE
Add Technical features chapter
24/09/2009
2.0
CLEODE
Validated document
24/09/2009
2.1
CLEODE
Updated for the new design
07/09/2011
3.0
CLEODE
Validated document
07/09/2011
3.1
CLEODE
Updated for the amplified signal
09/10/2012
4.0
CLEODE
Validated document
09/10/2012

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 6 sur 14
R
EFERENCE DOCUMENTS
N°
Document
Description
[1]
ZigBee_Cluster_Library_Public
Zigbee Cluster Library specification
[2]
ZigBee_Home_Automation_Profile Home Automation profile specification
[3]
ZigBee_Specification
ZigBee Specification
[4]
ZigBee_Smart_Energy_Profile
Zigbee Smart Energy profile specification

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 7 sur 14
I I
NTRODUCTION
I.1 ZPLUG
P
RESENTATION
The ZigBee™ AC 220V plug ZPLUG™ is a module the user can plug on directly in standard
220VAC outlets (C, E or F type) for
3500W
max appliance.
It is able to monitor how much electricity an appliance plugged into it is using.
The ZPLUG has this form:
Figure 1 : ZPLUG presentation
I.2 C
OPYRIGHT
The CLEODE trademark and the CLEODE logo are properties of CLEODE SA, France. This
document also refers to trademarks and other product names that are registered trademarks of
their respective owners.
Copyright © 2009 CLEODE SA. All rights reserved.

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 8 sur 14
II ZPLUG
DESCRIPTION
II.1 Z
IG
B
EE PRESENTATION
The ZPLUG contains an application with :
Switching on/off the appliance plugged into the plug. This is based on the
MainPowerOutlet application defined in the ZigBee Home Automation profile.
The measure of the consumption of the appliance plugged into the plug. The power
socket can accept devices up to
3500 watts
.
For more detail on the data exchange between device and network, see documents [1], [2], [3]
and [4].
The ZPLUG embedded the router functionality with amplified signal up to + 20 dBm. This
means that the ZPLUG is able to extend the ZigBee Network.
II.2 DESCRIPTION
OF
THE
AVAILABLE
INFORMATION
The switching is made by sending a command On/Off on the
On/Off
cluster.
The simple metering is used to monitor how much electricity an appliance plugged into it is
using. This application is able to send the current demand of energy in KW and the most
recent summed value of energy used in KWh.
II.2.1
D
ESCRIPTION OF THE APPLICATION
Device ID : Mains Power Outlet
Endpoint : 1
Clusters :
Côté serveur
Côté client
Basic (0x00)
/
Identify (0x03)
/
Groups (0x04)
/
Scenes (0x05)
/
On/Off (0x06)
/
Simple Metering (0x0702)
/

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 9 sur 14
II.2.2
CLUSTERS DESCRIPTION
This is a terse description of clusters and attributes implemented in the switch ZigBee ™. For
more precision on the functioning of these, would like refer to documents [1] and [4].
Basic cluster :
This cluster is used to determine basic information about the device.
Attribute
Attribute ID
ZCLVersion
0x0000
ApplicationVersion
0x0001
StackVersion
0x0002
HWVersion
0x0003
ManufacturerName
0x0004
ModelIdentifier
0x0005
DateCode
0x0006
PowerSource
0x0007
LocationDescription
0x0010
PhysicalEnvironment
0x0011
DeviceEnabled
0x0012
AlarmMask
0x0013
Cluster Identify :
This cluster is used to identify physically the object in the network. On writing of the
value of the attribute
IdentifyTime
the LED of the object is going to flash during the time
specified by this value.
Attribute
Attribute ID
IdentifyTime
0x0000
Cluster Groups:
This cluster allows to storing the name of the groups to which Zplug belongs.
Attribute
Attribute ID
NameSupport
0x0000

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 10 sur 14
Cluster Scenes:
This cluster allows to managing the scene of which is a part Zplug.
Attribute
Attribute ID
SceneCount
0x0000
CurrentScene
0x0001
CurrentGroup
0x0002
SceneValid
0x0003
NameSupport
0x0004
On/Off cluster:
This cluster is used to switching the device between On and Off states.
Attribute
Attribute ID
On/Off
0x0000
Cluster Simple Metering :
The attributes of the cluster Simple Metering implemented in the power plug:
Attribute
Attribute ID
CurrentSummationDelivered
0x0000
Status
0x0200
UnitofMeasure
0x0300
Multiplier
0x0301
Divisor
0x0302
SummationFormatting
0x0303
DemandFormatting
0x0304
MeteringDeviceType
0x0306
InstantaneousDemand
0x0400
Two attributes of
SimpleMetering
send periodic reports :
CurrentSummationDelivered : represents the most recent summed value of Energy in
Kwh.
InstantaneousDemand : represents the current Demand of Energy in Kw.
These used reports mechanisms described the document [1].
Every 12 hours, the value of CurrentSummationDelivered is store in memory, it allows in
case of power cut to keep this value.

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 11 sur 14
III I
NSTALLATION AND
W
ORKING
III.1 I
NSTALLATION
The user has to plug the ZPLUG on a socket in the wall and plug the appliance on it.
At plugging, the ZPLUG sends beacon request on the network. If a ZigBee coordinator or
router is able to associate the ZPLUG the ZPLUG enters in the network.
III.2 W
ORKING
III.2.1 O
N
/O
FF SWITCHING
The first time the ZPLUG is plugged in the socket, the switch is ON.
In each switching, the ZPLUG keeps the value of the attribute ON / OFF in memory not
volatile. Consequently, if a power cut or a disconnection of the ZPLUG arrives, this one will
find the state of switching in the restart.
This switching can take place of two different ways:
By pressing on the present button in facade,
By sending a command on ZPLUG by the connection ZigBee.
When the output of the ZPLUG is fed, the LED of the ZPLUG is lit in red otherwise it is put
out.
III.2.2 R
ESET
ZPLUG
To make a reset of the network parameters of Zplug, you have to press on the button during at
least 5s.
III.2.3 S
CAN OF THE NETWORK
If your Zplug does not find a network available ZigBee it will make automatically a new scan
at the end of 15 minutes. This time will increase twofold every time the ZPLUG makes a scan
without finding of available network.
If you wish to boost a scan of the network manually you have to press during 3 seconds on the
button of the ZPlug, this will have the effect of making the LED of the ZPLUG flash. If your
ZPlug is already associated, presses it during 3 seconds on the button will have no effect

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 12 sur 14
IV T
ECHNICAL FEATURES
Weight
150 g
Power Supply
220V French standard
Accuracy Measurement
±1 % of full scale
Commutation
Up to 16A on 220V
Transmission range
300 m outdoor
90 m indoor
Output Power
Up to + 20dBm
Managed channels (frequency)
16 channels ZigBee™ (2.405 à 2.480 GHz)

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 13 sur 14
R
EPAIR AND MAINTENANCE
Defective equipments shall be first reported to the CLEODE support team in order to be
assigned an RMA number. Be prepared to state your name, company and the serial number of
the defective item to the support personnel.
The item shall then be returned to CLEODE with the following documents:
The RMA number
A copy of the delivery slip
A detailed description of the default and the test context
The maintenance period is typically four (4) weeks starting from the date of reception of the
equipment at the CLEODE headquarters.
Remark : A FAQ (Frequently Asked Questions) is available on the
www.cleode.com
web site.

User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 14 sur 14
CLEODE S.A.
Technical Support Division
3 Rue Thomas Edison
22300 Lannion
France
Phone : +33 (0) 2 96 48 68 18
Fax : +33 (0) 2 96 48 19 11
E-mail :
support@cleode.com
Web :
http://www.cleode.com