ZigBee Power Plug 

ZPLUG 

 

 
 
 
 

 

User Manual 

 

 
 

 

 
 
 
Révision 4.0 
Document : UM_ZPLUG_20090903_001_04_00 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 2 sur 14 

W

ARRANTY

 

 
The device supplied to the buyer and/or the recipient is guaranteed by CLEODE against any 
malfunctions originating from a design and/or manufacturing flaw, for a period of twelve (12) 
months  following  delivery.  The  buyer  and/or  recipient  is  (are)  responsible  for  proving  the 
existence of the said defects or flaws. This warranty is applicable in accordance with articles 
1641 to 1648 of the French Civil Code and in compliance with the French statutory warranty. 
The warranty covers the replacement free of charge of devices and parts affected by a design 
and/or  manufacturing  flaw  excluding  conspicuous  defects  in  the  device  that  are  covered  by 
the buyer and/or the recipient. 
 
In order to invoke the warranty, the buyer must immediately send written notice to CLEODE 
of  the  flaws  that  it  attributes  to  the  device.  It  must  enable  CLEODE  to  have  access  to  the 
device  to  observe  these  defects  and  repair  them.  The  warranty  provided  by  CLEODE  is 
strictly  limited  to  the  equipment  provided  and  shall  only  have  for  effect  the  replacement  or 
repair,  at  CLEODE’s  expense,  on  its  own  premises,  of  all  devices  or  parts  that  are  not 
functioning as a result of defects or flaws. CLEODE reserves the right to modify the devices 
in order to comply with the warranty. 
 
The warranty does not apply to replacement or repairs that may result from normal wear and 
tear of devices, systems or products, damage or accidents resulting from negligence, failure to 
supervise or maintain, or incorrect use of the devices, systems and/or products. 
 
The  maintenance  service  is  provided  by  CLEODE  with  all  reasonable  care  possible  and  in 
compliance with the current state of the arts. 
 
The exchange of parts or repairs performed under the warranty cannot result in extending the 
length of the warranty. In no event can the unavailability of the device due to servicing give 
rise  to  compensation  for  any  reason  whatsoever.  The  seller  is  released  from  all  obligations 
relating  to  the  warranty  if  the  product  or  device  has  been  modified  without  prior  written 
consent,  or  if  original  parts  have  been  replaced  by  parts  which  it  has  not  manufactured 
without  prior  consent.  If  unforeseen  damage  is  caused  by  the  device,  it  is  expressly  agreed 
that the seller can only be liable for the reimbursement of monies received for the purchase of 
the device if it  has been destroyed. Under no circumstances can the seller be held  liable for 
indirect or contingent damage. The seller is released from any liability and the buyer waives 
any  rights  against  it  if  an  accident  or  direct  or  indirect  damage  is  caused  to  the  buyer 
following a defect, incorrect usage, incorrect maintenance or normal wear of the device sold. 
 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 3 sur 14 

T

ABLE OF CONTENT

 

WARRANTY ......................................................................................................................................... 2

 

REFERENCE DOCUMENTS ............................................................................................................. 6

 

I

 

INTRODUCTION ........................................................................................................................... 7

 

I.1

 

ZPLUG

 

P

RESENTATION

 ............................................................................................................... 7

 

I.2

 

C

OPYRIGHT

 ................................................................................................................................... 7

 

II

 

ZPLUG DESCRIPTION ............................................................................................................... 8

 

II.1

 

Z

IG

B

EE PRESENTATION

 .............................................................................................................. 8

 

II.2

 

DESCRIPTION

 

OF

 

THE

 

AVAILABLE

 

INFORMATION .................................................... 8

 

II.2.1

 

D

ESCRIPTION OF THE APPLICATION

 ............................................................................................ 8

 

II.2.2

 

CLUSTERS DESCRIPTION

.............................................................................................................. 9

 

III

 

INSTALLATION AND WORKING ........................................................................................ 11

 

III.1

 

I

NSTALLATION

.......................................................................................................................... 11

 

III.2

 

W

ORKING

 ................................................................................................................................. 11

 

III.2.1

 

O

N

/O

FF SWITCHING

 ................................................................................................................. 11

 

III.2.2

 

R

ESET 

ZPLUG ........................................................................................................................ 11

 

III.2.3

 

S

CAN OF THE NETWORK

 .......................................................................................................... 11

 

IV

 

TECHNICAL FEATURES ........................................................................................................ 12

 

REPAIR AND MAINTENANCE ...................................................................................................... 13

 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 4 sur 14 

L

IST OF FIGURES

 

Figure 1 : ZPLUG presentation .................................................................................................. 7 

 
 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 5 sur 14 

 

T

ABLE OF REVISIONS

 

Version 

Authors(s) 

Version description 

Date 

0.1 

CLEODE 

Initial version 

03/09/2009 

1.0 

CLEODE 

Validated document 

08/09/2009 

1.1 

CLEODE 

Add Technical features chapter 

24/09/2009 

2.0 

CLEODE 

Validated document 

24/09/2009 

2.1 

CLEODE 

Updated for the new design 

07/09/2011 

3.0 

CLEODE 

Validated document 

07/09/2011 

3.1 

CLEODE 

Updated for the amplified signal 

09/10/2012 

4.0 

CLEODE 

Validated document 

09/10/2012 

 
 
 
 
 
 
 
 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 6 sur 14 

 

R

EFERENCE DOCUMENTS

 

 
N° 

Document 

Description 

[1] 

ZigBee_Cluster_Library_Public 

Zigbee Cluster Library specification 

[2] 

ZigBee_Home_Automation_Profile  Home Automation profile specification 

[3] 

ZigBee_Specification 

ZigBee Specification 

[4] 

ZigBee_Smart_Energy_Profile 

Zigbee Smart Energy profile specification 

 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 7 sur 14 

I  I

NTRODUCTION

 

I.1 ZPLUG

 

P

RESENTATION

 

 
The ZigBee™ AC 220V plug ZPLUG™ is a module the user can plug on directly in standard 
220VAC outlets (C, E or F type) for 

3500W

 max appliance. 

It is able to monitor how much electricity an appliance plugged into it is using. 
 
The ZPLUG has this form: 

 

Figure 1 : ZPLUG presentation 

 

I.2 C

OPYRIGHT

 

 
The CLEODE trademark and the CLEODE logo are properties of CLEODE SA, France. This 
document also refers to trademarks and other product names that are registered trademarks of 
their respective owners. 
Copyright © 2009 CLEODE SA. All rights reserved. 
 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 8 sur 14 

II  ZPLUG

 DESCRIPTION

 

II.1  Z

IG

B

EE PRESENTATION

 

The ZPLUG contains an application with :  

 

Switching  on/off  the  appliance  plugged  into  the  plug.  This  is  based  on  the 
MainPowerOutlet application defined in the ZigBee Home Automation profile. 

 

The  measure  of  the  consumption  of  the  appliance  plugged  into  the  plug.  The  power 
socket can accept devices up to 

3500 watts

 

For more detail on the data exchange between device and network, see documents [1], [2], [3] 
and [4]. 
 
The  ZPLUG  embedded  the  router  functionality  with  amplified  signal  up  to  +  20  dBm.  This 
means that the ZPLUG is able to extend the ZigBee Network. 
 

II.2  DESCRIPTION

 

OF

 

THE

 

AVAILABLE

 

INFORMATION 

The switching is made by sending a command On/Off on the 

On/Off

 cluster. 

 
The simple metering is used to monitor how much electricity an appliance plugged into it is 
using.  This  application  is  able  to  send  the  current  demand  of  energy  in  KW  and  the  most 
recent summed value of energy used in KWh.  
 

II.2.1 

D

ESCRIPTION OF THE APPLICATION

 

 

Device ID : Mains Power Outlet 

 

Endpoint : 1 

 

Clusters : 

 

Côté serveur 

Côté client 

Basic (0x00)  

Identify (0x03) 

Groups (0x04) 

Scenes (0x05) 

On/Off (0x06) 

Simple Metering (0x0702) 

 
 
 
 
 
 
 
 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 9 sur 14 

II.2.2 

CLUSTERS DESCRIPTION

 

This is a terse description of clusters and attributes implemented in the switch ZigBee ™. For 
more precision on the functioning of these, would like refer to documents [1] and [4]. 
 

 

Basic cluster : 

This cluster is used to determine basic information about the device. 
 

Attribute 

Attribute ID 

ZCLVersion 

0x0000 

ApplicationVersion 

0x0001 

StackVersion 

0x0002 

HWVersion 

0x0003 

ManufacturerName 

0x0004 

ModelIdentifier 

0x0005 

DateCode 

0x0006 

PowerSource 

0x0007 

LocationDescription 

0x0010 

PhysicalEnvironment 

0x0011 

DeviceEnabled 

0x0012 

AlarmMask 

0x0013 

 

 

Cluster Identify : 

This  cluster  is  used  to  identify  physically  the  object  in  the  network.  On  writing  of  the 
value of the attribute 

IdentifyTime

 the LED of the object is going to flash during the time 

specified by this value. 
 

 

Attribute 

Attribute ID 

IdentifyTime 

0x0000 

 
 

 

Cluster Groups: 

This cluster allows to storing the name of the groups to which Zplug belongs. 

 

Attribute 

Attribute ID 

NameSupport 

0x0000 

 
 
 
 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 10 sur 14 

 

Cluster Scenes: 

This cluster allows to managing the scene of which is a part Zplug. 

 

Attribute 

Attribute ID 

SceneCount 

0x0000 

CurrentScene 

0x0001 

CurrentGroup 

0x0002 

SceneValid 

0x0003 

NameSupport 

0x0004 

 

 

On/Off cluster: 

This cluster is used to switching the device between On and Off states. 
 

Attribute 

Attribute ID 

On/Off 

0x0000 

 

 

Cluster Simple Metering : 

The attributes of the cluster Simple Metering implemented in the power plug: 

 

Attribute 

Attribute ID 

CurrentSummationDelivered 

0x0000 

Status 

0x0200 

UnitofMeasure 

0x0300 

Multiplier 

0x0301 

Divisor 

0x0302 

SummationFormatting 

0x0303 

DemandFormatting 

0x0304 

MeteringDeviceType 

0x0306 

InstantaneousDemand 

0x0400 

 
Two attributes of  

SimpleMetering

 send periodic reports : 

 

CurrentSummationDelivered : represents the most recent summed value of Energy in 
Kwh. 

 

InstantaneousDemand : represents the current Demand of Energy in Kw. 

 
These used reports mechanisms described the document [1]. 
 
Every  12  hours,  the  value  of  CurrentSummationDelivered  is  store  in  memory,  it  allows  in 
case of power cut to keep this value. 
 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 11 sur 14 

III I

NSTALLATION AND 

W

ORKING

 

III.1  I

NSTALLATION

 

 

The user has to plug the ZPLUG on a socket in the wall and plug the appliance on it. 
 
At  plugging,  the  ZPLUG  sends  beacon  request  on  the  network.  If  a  ZigBee  coordinator  or 
router is able to associate the ZPLUG the ZPLUG enters in the network. 
 

III.2  W

ORKING

 

 

III.2.1  O

N

/O

FF SWITCHING

 

The first time the ZPLUG is plugged in the socket, the switch is ON. 
 
In  each  switching,  the  ZPLUG  keeps  the  value  of  the  attribute  ON  /  OFF  in  memory  not 
volatile. Consequently, if a power cut or a disconnection of the ZPLUG arrives, this one will 
find the state of switching in the restart. 
 
This switching can take place of two different ways: 

 

By pressing on the present button in facade, 

 

By sending a command on ZPLUG by the connection ZigBee. 

 
When the output of the ZPLUG is fed, the LED of the ZPLUG is lit in red otherwise it is put 
out. 
  

III.2.2  R

ESET 

ZPLUG 

To make a reset of the network parameters of Zplug, you have to press on the button during at 
least 5s. 
 

III.2.3  S

CAN OF THE NETWORK

 

If your Zplug does not find a network available ZigBee it will make automatically a new scan 
at the end of 15 minutes. This time will increase twofold every time the ZPLUG makes a scan 
without finding of available network. 
 
If you wish to boost a scan of the network manually you have to press during 3 seconds on the 
button of the ZPlug, this will have the effect of making the LED of the ZPLUG flash. If your 
ZPlug is already associated, presses it during 3 seconds on the button will have no effect 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 12 sur 14 

IV T

ECHNICAL FEATURES

 

Weight 

150 g 

Power Supply 

220V French standard 

Accuracy Measurement 

±1 % of full scale 

Commutation 

Up to 16A on 220V 

Transmission range 

300 m outdoor 

90 m indoor 

Output Power 

Up to + 20dBm 

Managed channels (frequency) 

16 channels ZigBee™ (2.405 à 2.480 GHz) 

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 13 sur 14 

R

EPAIR AND MAINTENANCE

 

Defective  equipments  shall  be  first  reported  to  the  CLEODE  support  team  in  order  to  be 
assigned an RMA number. Be prepared to state your name, company and the serial number of 
the defective item to the support personnel. 
 
The item shall then be returned to CLEODE with the following documents: 

 

The RMA number 

 

A copy of the delivery slip 

 

A detailed description of the default and the test context 

 
The maintenance period is typically four (4) weeks starting from the date of reception of the 
equipment at the CLEODE headquarters. 
 
 
 
Remark : A FAQ (Frequently Asked Questions) is available on the 

www.cleode.com

 web site.

  

 


background image

User Manual – ZPLUG 

UM_ZPLUG_20090903_001_04_00.doc 

                             CLEODE                                                         Page 14 sur 14 

 

 

 

 

 

 

CLEODE S.A. 

Technical Support Division 

 

3 Rue Thomas Edison 

22300 Lannion 

France 

Phone : +33 (0) 2 96 48 68 18 

Fax : +33 (0) 2 96 48 19 11 

 

E-mail : 

support@cleode.com

 

Web :   

http://www.cleode.com