PDF User Manual

  1. Home
  2. Manuals
  3. Clearswift SECURE ICAP Installation & Getting Started Manual

Clearswift SECURE ICAP Installation & Getting Started Manual

Made by: Clearswift
Type: Installation & Getting Started Guide
Category: Gateway
Pages: 21
Size: 0.22 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

Clearswift SECURE ICAP Gateway

Installation & Getting Started Guide

Version 4.5.0

Document Revision 1.0

 


background image

Copyright

Revision 1.0, November, 2016

Published by Clearswift Ltd.

© 1995–2016 Clearswift Ltd.

All rights reserved.

The materials contained herein are the sole property of Clearswift Ltd. unless

otherwise stated. The property of Clearswift may not be reproduced or

disseminated or transmitted in any form or by any means electronic, mechanical,

photocopying, recording, or otherwise stored in any retrievable system or

otherwise used in any manner whatsoever, in part or in whole, without the express

permission of Clearswift Ltd.

Information in this document may contain references to fictional persons,

companies, products and events for illustrative purposes. Any similarities to real

persons, companies, products and events are coincidental and Clearswift shall not

be liable for any loss suffered as a result of such similarities.

The Clearswift Logo and Clearswift product names are trademarks of Clearswift

Ltd. All other trademarks are the property of their respective owners. Clearswift Ltd.

(registered number 3367495) is registered in Britain with registered offices at 1310

Waterside, Arlington Business Park, Theale, Reading, Berkshire RG7 4SA, England.

Users should ensure that they comply with all national legislation regarding the

export, import, and use of cryptography.

Clearswift reserves the right to change any part of this document at any time.

Click

here

to read Copyright and Acknowledgments in full.

 


background image

Contents

Copyright

ii

Contents

iii

1. About this guide

4

1.1 Who is this guide for?

4

2. Before installing

5

2.1 Types of installation

5

2.2 Obtaining the software

5

2.3 Prerequisites

5

Hardware requirements

5

Installation media

6

Browser support

6

3. Installing the Clearswift SECURE ICAP Gateway

7

3.1 Installing the Clearswift SECURE ICAP Gateway

7

3.2 Installing from the ISO image

7

3.3 Running the Clearswift First Boot Console

8

Notes on using the Clearswift SECURE ICAP Gateway installation wizard

12

3.3.1 How to re-enable TLS v1.0 on the 4.5.0 Gateway and update ciphers: 12

3.4 Enabling access to the Clearswift online repositories

13

4. Upgrading from version 3.2 of the Clearswift SECURE ICAP Gateway15

4.1 Back up your original system

15

4.2 Install the 4.5.0 Gateway

16

4.3 Restore the system backup

16

5. Upgrading from an earlier version 4 release to version 4.5.0

17

Appendix A: Software install process

19

Post installation considerations

20

Appendix B: USB installation media preparation

20

 


background image

1. About this guide

This guide provides information for administrators installing the Clearswift SECURE

ICAP Gateway onto a virtual machine or physical server. It covers the procedures

and requirements necessary for a full installation.

1.1 Who is this guide for?

This guide is intended for use by:

n

New customers installing the Clearswift SECURE ICAP Gateway for the first

time.

n

Existing customers upgrading from the most up to date version 3.2 release of

the Clearswift SECURE ICAP Gateway to a 4.5.0 release.

If you are upgrading from an earlier version 4 release of the Clearswift SECURE

ICAP Gateway, see the

4.5.0 Readme

. for guidance.

- 4 -

 


background image

2. Before installing

This section outlines prerequisites and considerations you need to make before

installing the Clearswift SECURE ICAP Gateway. The Gateway runs on 64 bit

Red Hat Enterprise Linux (RHEL 6.8). You can install the product on a physical

server or virtual machine. See

Prerequisites

for more information on supported

platforms.

2.1 Types of installation

You can install the Clearswift SECURE ICAP Gateway using one the following

processes:

Installation process

Description

Where to start

Standard install

process

Applies to users installing the product from an

ISO image that contains both RHEL 6.8 and the

Clearswift software.

Installing from

the ISO image

Hardware install

process

Applies to users deploying the product using pre-

installed hardware supplied by Clearswift.

Running the

Clearswift First

Boot Console

Software install

process

Applies to users installing the product on an

existing RHEL 6.8 platform.

Appendix A:

Software Install

Process

2.2 Obtaining the software

You can obtain the Clearswift SECURE ICAP Gateway software from:

n

The

Clearswift download area

where you can download the Clearswift

SECURE ICAP Gateway ISO image.

n

Clearswift, with your pre-installed hardware.

2.3 Prerequisites

Before installing, you should check that you have the following:

Hardware requirements

Your computer or virtual machine requires a minimum of 6GB RAM and a 60GB

hard drive for use in testing and demonstration environments. Clearswift

- 5 -

 


background image

recommends a minimum of 8 GB RAM and 200GB hard drive for use in a

production environment based on your storage and processing requirements.

Installation media

Please ensure you are using the correct version of the ISO image: WEB_450.iso.

After you download a copy of the ISO image from the online Clearswift Repository,

there are a number of ways you can use it to install the software:

n

Copying the ISO image to DVD. Clearswift recommends using this option

when installing the Clearswift SECURE ICAP Gateway software.

n

Copying the ISO image to USB media. See Appendix B of this guide for

instructions.

n

Attaching the ISO image as a virtual DVD drive. This applies to virtual

machines only.

Browser support

The Clearswift SECURE ICAP Gateway supports connections using TLS 1.2 ciphers

and has been tested with the following browsers:

n

Internet Explorer IE10 (Windows 7)

n

Internet Explorer IE11 (Windows 7 , Windows 8)

n

Mozilla Firefox 17, 24, 30, 36+

n

Google Chrome 40+

n

Microsoft Edge (Windows 10)

- 6 -

 


background image

3. Installing the Clearswift SECURE ICAP
Gateway

You can install the Clearswift SECURE ICAP Gateway software from the ISO image

that you downloaded from the Online Clearswift Repository.

The installation process includes the following phases:

1. Combined installation of Red Hat Enterprise Linux 6.8 operating system and the

Clearswift SECURE ICAP Gateway from the installation media.

2. Running the console-based

System Configuration

wizard to adjust default

system values, including network configuration.

3. Enable access to the Clearswift online repositories containing the latest software

updates.

Once the Gateway has been installed, you will need to complete the

Clearswift

Installation Wizard

.

3.1 Installing the Clearswift SECURE ICAP Gateway

The following steps describe how to install the Clearswift SECURE ICAP Gateway.

Section 3.2 Installing from the ISO image

only applies if you are

performing a standard installation using the ISO image containing both

RHEL 6.8 and the Clearswift software.

If you are performing the hardware install, go to

Section 3.3 Running the

Clearswift System Configuration wizard

.

If you are installing onto an existing RHEL 6.8 server, use the instructions

in Appendix A of this guide to perform the installation. Then refer to

Phase 2 of installing the Clearswift SECURE ICAP Gateway.

3.2 Installing from the ISO image

1. Insert the media containing the ISO image into the drive and power on the

server.

The

Welcome to Clearswift Web Solutions

should be displayed. If the load device

can not be found you might need to adjust your system boot sequence in the

BIOS.

- 7 -

 


background image

2. Use the arrow keys or keyboard shortcuts to select

Install Secure ICAP

Gateway

from the menu. Press the

Enter

key to select the installation.

The install process begins and runs automatically.

The entire install process, including post-installation scripts, takes

between 10-15 minutes to complete. After

Package Installation

completes, the install process displays the message "Running post-

installation scripts" for a period of up to 5 minutes. When this message

is on screen, the install process still runs in the background and you

should not interrupt it. At the end of the install process, the system

reboots automatically. The

Welcome to Clearswift Web Solutions

boot

screen appears again and

Boot from local drive

triggers

automatically after a timeout of 60 seconds.

3.3 Running the Clearswift First Boot Console

Complete the following steps in the

First Boot Console

:

- 8 -

 


background image

1. Log in as cs-admin using the default credentials:

n

Login:

cs-admin

n

Password:

password

The

First Boot Console

appears and you can start the configuration process.

2. Follow the on-screen instructions to select:

n

Locale Configuration

n

Keyboard Configuration

n

Timezone Configuration

The Gateway derives its system time and locale settings from the

selections made at this point. It is important that you set these

correctly during installation as you cannot change system time and

locale later.

3. On the

Network Configuration

page update the following settings:

n

System Hostname: Enter the new Hostname and press

Save

.

n

Network Adapters: Select a network adapter and press

Edit

. Press

IPv4

Addresses

and then

Edit

your selected IP address. After you have made

your edits, press

Save

.

n

DNS Servers: Select a DNS entry and press

Edit

. Add

Search Domains

if

required or leave blank.

After you have made your edits, press

Save

.

4. Configure your repository settings on the

Repository Configuration

page.

5. On the

cs-admin password

page enter a new password for your cs-admin

account. The complexity of this password depends on the password policy that is

being enforced. The Clearswift password policy applies by default to standard

installations from the ISO image. This policy requires you to set passwords that

are a minimum of eight characters in length, do not resemble dictionary words

(example: Pa55word), do not include sequences (example: 1234), and include at

- 9 -

 


background image

least one from three of the following:

n

Uppercase letters

n

Lowercase letters

n

Digits

n

Symbols

See

Clearswift password policy requirements

in the online help for more

information, including examples. The online help also provides information on

how to disable the password policy.

6. Apply your settings and confirm to reboot the server.

7. Following the reboot, open a browser and navigate to the Gateway IP address:

https://

<ip-address>

/Appliance

To check your IP address, log in to the console using the default

credentials.

Select

View System Status

and click

OK

.

The

Clearswift SECURE ICAP Gateway

installation wizard is displayed.

- 10 -

 


background image

If the Clearswift installation media has been ejected following the

reboot, you

must

ensure that it is re-inserted

before

configuring the

Clearswift Installation Wizard. The wizard requires access to the

installation media to complete the setup of your Gateway.

- 11 -

 


background image

Notes on using the Clearswift SECURE ICAP Gateway installation wizard

The network settings displayed by the wizard reflect the settings you

created when configuring Red Hat Enterprise Linux. These settings are

displayed as read-only.

We recommend configuring the wizard immediately after the install and

before

configuring any additional network adapters. However, if you need

to reboot the machine before configuring the installation wizard, you

should disable your firewall as root user when your reboot is complete.

To disable your firewall, run the

service iptables stop

command. After you

complete the wizard, the firewall starts again automatically.

The system might take around 5-10 minutes to apply the settings before you can

use the Clearswift SECURE ICAP Gateway. We recommend visiting the

First Steps

topic in the online help when the Gateway interface is accessible.

Peering between v3 and v4 Clearswift Gateways

Due to security hardening on v4 Clearswift Gateways, we no longer

provide support for the TLS v1.0 protocol for peering. Only TLS v1.2 is

supported.

If you wish to peer v3 Gateways (for example, using PMM or Web

Gateway Reporter) with your v4 Gateway, you must

re-enable TLS

v1.0

on the 4.5.0 Gateway and

update the ciphers

.

These instructions should be applied

after

installing the 4.5.0 Gateway,

and after configuring the Gateway using the

Clearswift Installation

Wizard

.

3.3.1 How to re-enable TLS v1.0 on the 4.5.0 Gateway and update ciphers:

1. Search for the

sslEnabledProtocols

attribute in the following files:

/opt/tomcat/conf/

server-bind.xml

server-bind2.xml

2. Change the value of each protocol from 'TLSv1.2' to 'TLSv1,TLSv1.2'.

- 12 -

 


background image

There are two instances in server-bind2.xml.

3. Search for the

ciphers

attribute in the same files:

/opt/tomcat/conf/

server-bind.xml

server-bind2.xml

4. Add 'TLS_RSA_WITH_AES_256_CBC_SHA' to the end of the comma separated list

in each file.

There are two instances in server-bind2.xml.

5. Restart the UI using the following command:

cs-servicecontrol restart tomcat

3.4 Enabling access to the Clearswift online repositories

When you have installed the Clearswift SECURE ICAP Gateway, you need to enable

access to the Clearswift online repositories containing the latest software updates.

This is done in the Clearswift Server Console application:

1. From the Clearswift Server Console main menu, select

Configure System

>

Select Update Repositories

.

Clearswift Server Console checks the status of your YUM repositories and the

Select YUM Repositories

page appears.

2. Select the option to

Enable online repositories

. When the operation

completes, press

Done

.

Clearswift Server Console rechecks the status of your YUM repositories and

returns you to the

Select YUM Repositories

page where your online

repositories will now appear as enabled:

- 13 -

 


background image

3. Press

Back

to return to the

Configure System

page of the Clearswift Server

Console.

- 14 -

 


background image

4. Upgrading from version 3.2 of the Clearswift
SECURE ICAP Gateway

If you are installing the Clearswift SECURE ICAP Gateway for the first time,

please ignore this section.

If you are installing version 4.5.0 from an earlier version 3 Clearswift SECURE ICAP

Gateway, please ensure your Gateway is fully upgraded to the latest 3.2 release and

use the following instructions.

This section describes how to import your policy configuration and system settings

from version 3.2 of the Clearswift SECURE ICAP Gateway to version 4.5.0. You

should perform the backup steps

before

installing Clearswift SECURE ICAP

Gateway 4.5.0.

Migrating from a V3 Gateway does not preserve network settings such as

static hosts, static routes and DNS settings. Use the Server Console to re-

apply your network settings when you have upgraded your Gateway.

4.1 Back up your original system

The system backup on an FTP server includes only the most recently

applied configuration. If you require an earlier policy configuration along

with audit and tracking data and logs, you should first restore from the

system backup and then restore the .bk file to your new Gateway, when

installed.

1. Apply your configuration. This ensures that you are migrating the most up-to-

date version.

2. Using your existing Gateway system, navigate to the

System Center

>

Backup

& Restore

page.

3. Perform a System Backup using the

Backup System Now

option in the task

panel.

We strongly recommend that you backup all available System Areas.

- 15 -

 


background image

We recommend that you use system backups for a means of disaster

recovery and for when planning to upgrade your system. Do not use

them for any other purpose, for example, as a method of cloning

Gateways when creating a peer group. For purposes other than

disaster recovery and system upgrades you should use Configuration

Backup and Restore.

4.2 Install the 4.5.0 Gateway

Follow the steps in section 3 of this installation guide to install the Clearswift

SECURE ICAP Gateway.

When you have installed the Clearswift SECURE ICAP Gateway, you need to

configure access to the Clearswift online repositories containing the latest software

updates. See

Enabling access to the Clearswift online repositories

for more

information.

4.3 Restore the system backup

1. Using the new, installed Gateway, navigate to the

System Center

>

Backup &

Restore

page.

2. Select

Restore System

using the option in the task panel. Enter the FTP settings

and click

Connect

.

The system restore includes all the areas you selected when you created

your back-up, potentially including configurations and audit logs. The

Gateway reboots after the system restore is complete.

- 16 -

 


background image

5. Upgrading from an earlier version 4 release
to version 4.5.0

If you are installing the Clearswift SECURE ICAP Gateway for the first time,

please ignore this section.

Perform the following steps to download and apply software updates when you

upgrade to Clearswift SECURE ICAP Gateway 4.5.0.

Open an SSH session and access the Clearswift Server Console. Log in using your

cs-admin access credentials.

Online or Offline mode?

Offline mode

is designed for installations that operate in a closed

environment, disconnected from the Internet. Unless this is a specific

requirement for your system, you should install the Clearswift

SECURE ICAP Gateway in online mode.

To perform an offline upgrade you require a copy of the latest release

ISO mounted to suitable media (DVD/USB). Please contact Clearswift

Technical Support if you need additional guidance on how to

complete this step.

1. Confirm the upgrade is available:

a. If you are performing an offline upgrade, insert the physical media

(DVD/USB).

b. Confirm the required repositories are enabled and available:

Online mode:

Configure System

>

Select Update Repositories

Enable online

repositories

Offline mode:

Configure System

>

Select Update Repositories

Enable offline

repositories

- 17 -

 


background image

c. Check the upgrade is ready to install:

View System Status

If the expected upgrade is listed as the next "Available Upgrade", go directly to

step 3. If it is not listed, refresh the status and it should appear.

2. Download update:

a. From the Clearswift Server Console main menu, select:

Configure System

>

View and Apply Software Updates

>

Download

New Updates

OK

b. All available updates will now be downloaded. This process may take several

minutes. A rolling progress log will be displayed. When the

Operation

Complete

message appears, select

Done

to complete the download.

3. Apply software updates:

a. From the Clearswift Server Console main menu, select:

Configure System

>

View and Apply Software Updates

>

Apply

Updates

OK

b. Confirm that you want to apply the updates by selecting

Yes

.

All downloaded updates will now be installed. This process can take several

minutes. A rolling progress log will be displayed. When the

Operation

Complete

message appears, select

Done

to complete the install process.

- 18 -

 


background image

Appendix A: Software install process

The following steps describe how to install the Clearswift SECURE ICAP Gateway

on top of an existing Red Hat Enterprise Linux (RHEL) 6.8 Server using the ISO

image.

You should install RHEL 6.8 as a

Minimal

server installation, with a

separate /(root) and /var partition. The root partition should be 20GB

(minimum) and /var should use a minimum of 40GB for test

environments and 120GB for production environments.

To install the Clearswift SECURE ICAP Gateway:

1. Assume root role at the command line.

2. Insert the media containing the ISO image and mount it onto /media/os:

mkdir –p /media/os

mount /dev/cdrom /media/os

3. Manually install the cs-repo-conf package. The cs-repo-conf package configures

your system to be ready for you to install the Clearswift SECURE ICAP Gateway:

rpm –ivh /media/os/cs-repo/Packages/cs-web-repo-conf...

4. Forcibly remove postfix, rsyslog and samba V3:

yum –y remove postfix rsyslog samba-common

5. Install the required product using the following command:

yum install cs-sig

If Step 5 fails due to additional conflicts, you might need to remove

additional packages during Step 4.

6. Log out completely, and log back in as cs-admin. Refer to Phase 2 of installing

the Clearswift SECURE ICAP Gateway to continue.

- 19 -

 


background image

Post installation considerations

After completing the software install process, the install process might have

modified the following parts of your system:

1. Firewall configuration is now under Gateway control. If SSH access is required

you need to re-enable it through the Clearswift SECURE ICAP Gateway user

interface. See

Configuring SSH Access

in the Clearswift SECURE ICAP Gateway

online help for more information.

2. All network configuration is now under Server Console control. You should

avoid changing network configuration at the command line as the Gateway is

not notified of these changes. If changing network configuration at the

command line is necessary, please contact Clearswift Support for more

information.

3. crontab configuration is modified. Pre-existing root cronjobs might be lost, but

you can re-add them.

Appendix B: USB installation media preparation

The following steps describe how to copy the Clearswift SECURE ICAP Gateway

software ISO image to USB media.

1. Download the Clearswift SECURE ICAP Gateway software ISO image from the

Clearswift download area

.

Please ensure you are using the correct version of the ISO image: WEB_

450.iso.

2. Download a USB tool that maintains drive volume name. Clearswift

recommends using

Rufus Portable

.

Do not use the standard version of Rufus for this process. Please

ensure it is the portable version.

- 20 -

 


background image

Although you can use USB tools other than Rufus, the following USB

tools will not work with the Clearswift SECURE ICAP Gateway software

ISO image:

n

YUMI

n

Universal USB Installer

n

Fedora liveusb-creator

The below steps assume that you are using Rufus 2.11 Portable.

3. Run

rufus-2.11p.exe

.

4. Insert your USB media and select it from the

Device

drop-down menu.

5. Under

Format Options

, select

Create a bootable disk using

and click the

disk icon

to choose the Clearswift SECURE ICAP Gateway ISO you want to

burn. Once Rufus scans the ISO, it fills in other options automatically.

6. Click

Start

. The

ISOHybrid image detected

dialog box appears. Select

Write

in ISO Image mode (Recommended)

and then click

OK

. A dialog box

appears to warn you that any existing drive date will be removed. Click

OK

if

you are happy to proceed.

7. Return to

Installing the Clearswift SECURE ICAP Gateway

to complete the

installation process.

- 21 -