FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

Installation Manual 

 ____________________________________________________

Manual 020017 REV A - Oct 2018

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

2

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

Installation Manual 

 ______________________________________________________

Manual 020017 REV A - Oct 2018

Table of Contents

Application

  

3

Description

  

3

Technical Specifications

  

3

Components

  

4

Pedestal Access

  

6

Cable Preparation & Installation

  

7

Grounding

  

9

Fiber Splicing

  

9

Closing the Pedestal

  

12

Standard Warranty

  

13

Proprietary Notice

  

14

Technical Support

  

14

 


background image

3

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 020017 REV A - Oct 2018

Application

Description

The FieldSmart FDP Splice Only Pedestal provides splice or interconnect connectivity at 

the access point for the last mile drop. 

The FieldSmart FDP Splice Only Pedestal 

incorporates field-tested slack management and fiber splice trays to provide a craft-

friendly splice only access solution. The splice only pedestal can be configured to support 

the specific drop cable, multi-fiber and ring cut requirements. The Clearfield® designed 

back plane makes it possible for the bulkheads to integrate into industry standard 

pedestals.

Technical Specifications

The FieldSmart FDP Pedestal is a value added version of an Emerson BD5 distribution 

pedestal. This style pedestal is a round-cornered, square-design telephone distribution 

pedestal accepted for use by the RDUP (formerly RUS). The pedestal has been modified 

to accommodate the use of fiber optic distribution and drop splices.

This pedestal is designed to accommodate outside plant cables with a loose tube/buffer 

tube construction. It can handle both armored and non-armored cables. If cables are to 

be installed in a ring cut/mid-span opening configuration, then only cables capable of 

passing the RDUP mid-span criteria of the PE-91 specification are allowed.

Included in this pedestal are: a splice tray bracket, one splice tray, a dielectric wrap 

around shield, radius limiting spools, Velcro style cable management, cable securing zip 

ties and a shield isolation bonding/grounding bracket assembly.

FieldSmart Splice 

Only Pedestal

Metallic Emerson BD5 Non-metallic ProFORM 12 Non-metallic Pencell 

10 x 10

Dimension

43.25” H x 10.5” W x 10.5” D 45” H x 10.5” W x 14.5” D

31.4” H x 13” W x 13” D

Cover Height

31.25”

30”

20”

Base Height (Buried)

12”

15”

11.4”

Material

Galvanized steel

High performance thermo-plastic HDPE/LDPE

Density

Up to 384 splices

Up to 144 Splices

Number of Splice Trays Up to 16

Up to 6

Splice Capacity

24 splices in each splice tray

Splice Tray Dimensions 10 mm H x 163 mm W x 126 mm D

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

4

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

Installation Manual 

 ______________________________________________________

Manual 020017 REV A - Oct 2018

2

3

7

1

4

5

6

8

1. 

Radius limiting spool

2. 

Velcro cable management

3. 

Splice tray

4. 

Secondary splice tray holder mounting location 

5. 

Distribution and drop cables

6. 

Vinyl dust /UV shield 

7. 

Zip Tie cable management

8. 

Security screw

9. 

Grounding/Bonding Plate

10.  Outside cover

10

9

Metallic Emerson BD5

Components

 


background image

5

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 020017 REV A - Oct 2018

Non-metallic Pencell 10 x 10

1.  Radius limiting spool

2.  Velcro cable management

3.  Splice tray

4.  Outside cover

5.  Security screw

1

2

3

4

5

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

6

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

Installation Manual 

 ______________________________________________________

Manual 020017 REV A - Oct 2018

The interior of the pedestal can be accessed by loosening the security screw on the right hand side of the pedestal 

using a 7/16” thin wall socket or a telecommunications industry “can wrench”. 

Then, by supporting the top of the cover and pulling out and up on the handle, the outer cover of the pedestal can be 

removed to provide access to the interior.

Pedestal Access

1.

2.

Metallic Emerson BD5

Non-metallic Pencell 10 x 10

The interior of the pedestal can be accessed by 

turning the security screw on the pedestal using a 7/16” 

thin wall socket or a telecommunications industry “can 

wrench”. 

The cover can then be lifted away.

1.

2.

 


background image

7

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 020017 REV A - Oct 2018

Ring cut/Mid-span opening 

OSP distribution cables that are entering or exiting the pedestal can be prepped in either a ring cut/mid-span opening fash-
ion or at the end of the cable. 

End of the cable

Cable Preparation & Installation

3M 2172 

The pedestal is designed to hold more than 20 feet of buffer tube from a 144 OSP cable, but most manufacturers recom-

mend not exposing more than 20 feet in an OSP environment. This rule is especially true for ring cut applications (see 

RDUP PE91).

In either cable prep method, please verify with your cable manufacturer to see if a central strength member clamp (3M 2172 

or equivalent) must be installed to secure the central strength member, in order to maintain the cable warranty.

Cable clamp installed

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

8

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

Installation Manual 

 ______________________________________________________

Manual 020017 REV A - Oct 2018

 If a shielded cable is to be used and grounded in this application, 

then a bonding clamp (3M 4460-D or equivalent) shall be attached 

in addition to the strength member clamp.

3M 4460-D Bonding clamp installed

Cables to be installed can be secured to the 

back plane of the pedestal using the zip tie 

mounts found at the bottom of the pedestal.

When attaching the cables to the back plate using zip ties, it is very important to 

not fully tighten the zip ties around the cable. Each zip tie should allow at least 

1/8” of clearance on all sides. This is important as the cable will need to piston 

or freely move inside the zip tie independently from the pedestal in the case of 

pedestal shifting. Be sure to leave at least 4 - 6 inches of cable from the zip tie 

to the strength member tie-off.

Note:

 

A drop cable is also installed in this picture.

The excess buffer tube should then be routed loosely around the radius limiters 

provided and then secured loosely with the Velcro management that is installed 

in the pedestal.

Zip tie locations

 


background image

9

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 020017 REV A - Oct 2018

Each pedestal comes with a pre-installed grounding and bonding plate.

Grounding

Fiber Splicing

The pedestal is capable of holding up to 144 splices by adding up to eleven 12 fiber trays (part number 004834), one 

at a time to the included bracket.

Note: 

If more than 6 trays are used, you will not be able to hinge the entire stack to access lower splices. Although the 

bracket will accomodate12 trays, Clearfield recommends only using 6 trays for 72 splices. Trays can be added by sliding the 

new tray onto the hinge pins and then folding it down to snap the tray in place.

1.

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

10

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

Installation Manual 

 ______________________________________________________

Manual 020017 REV A - Oct 2018

Align the pins and insert into position

Fold the tray down and snap in place

Additional capacity (up to 12 more trays) can be added to the pedestal by adding a second splice tray bracket (part 

number 005622) to the back wall.

2.

 


background image

11

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 020017 REV A - Oct 2018

The bracket is installed using the pre-installed 

screws from the back plane. Remove the screws 

and discard the nuts.

The screws can then be used to attach the bracket 

to the pedestal

The first sacrificial splice tray is pre-installed with 

two 4-40 x 1/4” screws (part number 001523).

Note: 

The bottom tray is “sacrificial” because it must 

be screwed into place and cannot be removed for 

splicing as easily as the other trays.

3.

4.

5.

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

12

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

Installation Manual 

 ______________________________________________________

Manual 020017 REV A - Oct 2018

Closing the Pedestal

After work is completed in the pedestal, the black vinyl sheeting 

will need to be wrapped around the splice trays and secured into 

place using the slots and tabs that are precut into the vinyl.

The cover is replaced by first hanging the top of the pedestal cover from the back panel, then swinging the cover closed and 

tightening the security screw.

Security screw

 


background image

13

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 020017 REV A - Oct 2018

Standard Warranty

Clearfield warrants to the original purchaser of the Product sold hereunder is free from defects in material and workmanship under normal use and 

service, subject to exceptions stated herein. Product purchased is warranted as follows: Clearfield designed and branded Products are warranted for 

three (3) years: Products manufactured by Clearfield to customer prints and/or specifications are warranted for one (1) year; and any Product Clear-

field acquires from or through a third-party manufacturer or distributor and resells to Customer as the original customer will carry the manufacturer’s 

pass-through warranty, if any. In all cases, the warranty period commences on the date of shipment to the original purchaser.

Warranty Claim Procedure

If any Product purchased from Clearfield is found defective under the above warranty, the following basic procedure must be followed:

1.  Customer must contact Clearfield and obtain a Return Materials Authorization

2.  Following authorization, the Customer ships the product-freight collect-to Clearfield’s manufacturing facility

3.  Clearfield shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus-

tomer’s site, freight prepaid

Note: If the Product is not found to be defective at Clearfield, the product will be returned to the Customer and the customer billed for freight in both 

directions.

View our warranty policy here: 

https://www.seeclearfield.com/warranty.html

Limitations of Warranty

Correction of defects by repair or replacement, at the option of Clearfield Inc, shall constitute the exclusive sole remedy for a breach of this limited 

warranty. Clearfield shall not be liable under any circumstances for any special, consequential, incidental, punitive, or exemplary damages arising 

out of or in any way connected with the product or with agreement to sell product to buyer, including, but not limited to damages for lost profits, loss 

of use, or for any damages or sums paid by buyer to third parties. The foregoing limitation of liability shall apply whether the claim is based upon 

principles of contract, warranty, negligence or other tort, breach of statutory duty, principles of indemnity or contribution, the failure of any limited or 

exclusive remedy to achieve its essential purpose, or otherwise.

Clearfield will not be responsible for any labor or materials costs associated with installation or incorporation of Clearfield products at customer sites, 

including any costs of alteration, replacement or defective product, or any field repairs.

Other Limitations

Clearfield assumes no warranty liability regarding defects caused by:

1.  Customer’s modification of Product, excepting installation activities described in Clearfield documentation

2.  Customer re-packaging of Product for shipment to third parties or destinations other than those originally shipped to by Clearfield, or any de-

fects suffered during shipping where the Product has been re-packaged

3.  Customer’s installation or maintenance, excepting activities described in and performed in accordance with Clearfield documentation

4.  Customer’s improper or negligent use or application of Product

5.  Other causes external to the Product, including but not limited to accidents, catastrophe, acts of God, government action, war, riot, strikes, civil 

commotion, sovereign conduct, or the acts or conduct of any person or persons not party to or associated with Clearfield

6.  Environmental factors and weathering resulting in aging and damage not necessary or applicable to the function of the product

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

14

FieldSmart

®

 Fiber Distribution Point (FDP)

Splice Only Pedestal

Installation Manual 

 ______________________________________________________

Manual 020017 REV A - Oct 2018

Proprietary Notice

Information contained in this document is copyrighted by Clearfield, Inc. and may not be duplicated in full or part by any person without prior written 

approval of Clearfield, Inc.

Its purpose is to provide the user with adequately detailed documentation to efficiently install the equipment supplied. Every effort has been made to 

keep the information contained in this document current and accurate as of the date of publication or revision. 

However, no guarantee is given or implied that the document is error free or that it is accurate with regard to any specification.

Technical Support

Clearfield, Inc. can be contacted for any issues that arise with the supplied product.

If you need to return the supplied product, you must contact the Clearfield, Inc. Customer Service Department to request a Returned Materials 

Authorization (RMA) number.

Clearfield, Inc.

7050 Winnetka Ave N

Minneapolis, MN 55428

Toll Free:  

800.422.2537

Phone:    

763.476.6866

Fax:  

 

763.475.8457

Customer Support: sales@clfd.net

Technical Support:  techsupport@clfd.net