background image

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

Installation Manual 

 ______________________________________________________

Manual 019612 REV B - Aug 2018

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

2

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

Installation Manual 

 _________________________________________________________

Manual 019612 REV B - Aug 2018

Table of Contents

Application  

3

Description  

3

Technical Specifications

  

3

FEC Overview  

4

Cable Routing  

5

Splicing  

7

Grounding  

10

Standard Warranty  

11

Proprietary Notice  

12

Technical Support  

12

 


background image

3

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019612 REV B - Aug 2018

Application

Description

Technical Specifications

FieldSmart FxDS Fiber Entrance Cabinet

 Dimensions

17.5” H x 34.5” W x 8.25” D

 Ratings

Compliant to Telcordia GR-449

Cable Types

Indoor Riser, Indoor Plenum, Indoor/Outdoor, Outdoor (Riser/Non-Rated), Outdoor Armored 

(Riser/Non-Rated), FieldShield

®

 Splice Capacity

288 heat shrink fusion (HSF) loose tube or 864 mass fusion (MF) ribbon splices

 Storage Capacity

One meter of 900 μm fiber and five meters of exposed buffer tube

 Material

16 gauge cold rolled steel with almond powder coating

The FieldSmart Fiber Entrance Cabinet (FEC) provides 

off-frame splicing for the central office, headend or remote 

hut. Fiber Entrance Cabinets are typically placed in the fiber 

entrance room and used to transition OSP fiber sheaths to 

IFC cabling

The FieldSmart FEC is built on a modular platform, scaling 

288 heat shrink fusion (HSF) or 864 mass fusion (ribbon) 

fiber splices at a time. Multiple entry/exit points allow for 

multiple distribution and OSP fiber sheaths to enter into the FEC from top, bottom, or sidewalls and transition from conduit, 

overhead fiber tray, or raised flooring. A removable splice block, holding twelve 24-fiber splice trays, gives the user the 

ability to prep away from the cabinet. Intuitive buffer tube and sub-unit slack routing prevents cable tie-in with a clockwise 

routing scheme to allow quick and easy re-entry after initial deployment or to add additional capacity. If vertical real estate is 

available, the FEC can be ganged together, in modular fashion, allowing scalability up to 864-fiber splices and beyond. 

Each cable entrance plate will support cable diameters up to one inch. Lockable cupboard style doors allow for easy access 

with minimal swing clearance needed for tight aisle clearances.

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

4

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

Installation Manual 

 _________________________________________________________

Manual 019612 REV B - Aug 2018

The FieldSmart FEC is built on a modular platform scaling 288 fiber splices at a time. Lockable cupboard style doors allow 

for easy access with minimal swing clearance required for tight aisle clearances. The fiber entrance cabinet comes with a 

clamp kit. 

 

Note:

 

The FEC does NOT come with hardware to mount to the wall. Depending on the type or style of the wall the end user 

should obtain the appropriate hardware from their local hardware store. There are four (4) mounting holes. The mounting 

holes are .350” in diameter. The FEC Cabinet is 17.5” high x 34.5” wide and 8.25” deep.

FEC Overview

The parts below are shipped along with the FEC. The parts include the clamp kit and the plates to cover the numerous 

cable entry/exit points. Splice trays sold separately.

 

Item Number

Item Description

Quantity

 001527

SCREW, ROUND HEAD, PHILLIPS, 1/4-20 X 1 1/2”

8

 002127

PLUG, BUTTON, BLACK POLYETHYLENE, FITS 1-5/16in HOLE X .01in-.10in THICK PANEL

14

 003042

TAPE, GROMMETING, 1”, STRIPPING=1/8” X 1”, FEET

5

 003083

STRAP, VELCRO, BLACK, 1/2” WIDE, FEET

2

 003711

SADDLE, CLAMPING, 1/2” DIAMETER, GREEN POLYPROPYLENE, GRP3

4

 003716

SADDLE, CLAMPING, 1” DIAMETER, GREEN POLYPROPYLENE, GRP3

4

 009217

SCREW, PAN HEAD, PHILLIPS, 10-32 X 1/4”, 18-8 SST

32

 009902

BRACKET, FEC ENCLOSURE

4

 009909

PLATE, COVER, FEC, ENCLOSURE

15

An optional locking kit is available (P/N 010503) and is installed by two screws each at the top and bottom of the FEC. Lock 

is not provided. Locking tab should be positioned to the right when installed.

17.5”

34.5”

34.5”

8.25”

 


background image

5

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019612 REV B - Aug 2018

Once the FEC is mounted to the wall, you are now ready to route fiber into the cabinet.

Multiple entry/exit points allow for multiple distribution and OSP fiber sheaths to enter the FEC from the top, bottom, or 

sidewalls, transitioning from conduit, overhead fiber tray or raised flooring. Cable entry/exit points are located around the 

perimeter of the cabinet. See pictures below.

Note: 

Each cable entrance plate will support cable diameters up to 1 inch.

The cabinet comes with 4 sheet metal brackets for cable mounting and 16 blank plastic plates. The cables can be installed 

with either the clamps on the outside of the cabinet or with the clamps on the inside of the cabinet for extra security. Plugs 

are also included in the kit to fill the unused holes.

Choose the appropriate sized cable clamp for the cable entering the FEC.  Always use a clamp large enough to close 

around the cable, and utililze grommet tape to make up for the size difference by laying a small strip of grommet tape inside 

the cable clamp shell. 

DO NOT

 use a clamp that “pinches” the cable. 

Note:

 

Grommet tape included in the kit may be used to build up the cable size to get a better grip with the provided clamps.

A removable splice block, holding twelve 24-fiber splice trays, allows the user to prep away from the cabinet.

Note:

 

Splice trays are sold separate

ly

 (P/N 019339).

Cable Routing

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

6

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

Installation Manual 

 _________________________________________________________

Manual 019612 REV B - Aug 2018

Intuitive buffer tube and subunit slack routing prevents cable tie-in’s, utilizing a clockwise routing scheme to allow quick and 

easy re-entry after initial deployment or to add additional capacity. 

If the cables are to be carried from one cabinet into the 

next, then the blank plates and bracket plates will not 

need to be used between the two cabinets. There is a 

removable bracket on the top and bottom entrances 

that will allow you to lay cables in without having to cut 

them.

After choosing the entrance that will be used for your cables you will need to plan your cable route within the cabinet. All 

cables should eventually route in a clockwise direction. Depending on where you enter the box you may have to use the 

redirect spool in order to achieve a clockwise rotation.

No Redirect Used

Redirect Used

 


background image

7

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019612 REV B - Aug 2018

After all cables are routed in the correct direction and there is an adequate 

amount of slack in the cabinet, the cable tie down locations can be marked with a 

permanent marker. 

Splice trays (P/N 019339) will be shipped with 2 standard splice chips and 2 

ribbon splice chips, allowing for a total of 24 loose tube splices or 6 ribbon mass 

fusion splices (72 fibers). Splice chips will need to be bent into place in the empty 

slots in the center of the splice tray.

Note: 

Each standard splice chip features 6x2 splice sleeve slots, allowing for 

12 splice sleeves to be stacked 2 high in the 6 slots. Each ribbon splice chip  

features 3 ribbons splice sleeve slots, as well as one 2 high loose tube splice 

sleeve slot for use in special applications or repairs.

Splicing

Splice Chip

Ribbon Splice Chip

Bending the Splice Chip

Splice Tray Loaded with 

2 Splice Chips

Splice Tray Loaded with 

2 Ribbon Splice Chips

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

8

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

Installation Manual 

 _________________________________________________________

Manual 019612 REV B - Aug 2018

An example of a splice tray utilizing the splice 

chips to secure 24 loose tube splice sleeves is 

shown here. 

Wrap a layer of grommet tape around the buffer 

tubes and secure into place in the splice tray 

using the tie-down holes and cable ties.

Provided with the splice tray are 3 ribbon tie-downs which utilize a split grommet and retention cover which will allow the 

ribbon to be secured into the tray even in mid-span/ring cut applications.

Slip the split rubber grommet onto the ribbon, followed by the plastic retention cover over the opposite side.

Note:

 

Extra ribbon tie-downs are available in a kit, which can be ordered separately (P/N 019501).

After protecting the ribbon fiber with the ribbon 

tie-down, secure it into the tray.

The splice tray features tie-down holes on each 

side of the tray, which will allow for 5 ribbon tie-

downs per side, as well as one ribbon tie down on 

each side in the additional holding location.

Additional Holding 

Location

Standard 

Tie-Down

 


background image

9

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019612 REV B - Aug 2018

The entire block of splice trays can be removed 

for splicing by loosening the thumb screw in the 

top left corner and lifting the block of splice trays.

After splicing, the splice trays can be secured into 

place using the included velcro strap.

Thumb Screw

Velcro

An example of a spliced up FEC, transitioning 

from outside to inside plant cable, is shown here.

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

10

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

Installation Manual 

 _________________________________________________________

Manual 019612 REV B - Aug 2018

FECs can be ganged together, in modular fashion, allowing scalability up to 864 fiber splices and beyond if vertical real 

estate is available. Below is an example of multiple FEC’s ganged together.

Grounding

FEC Cabinets are easily grounded using the integrated ground bar. Ground per your local rules and practices.

 


background image

11

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019612 REV B - Aug 2018

Standard Warranty

Clearfield warrants to the original purchaser of the Product sold hereunder is free from defects in material and workmanship under normal use and 

service, subject to exceptions stated herein. Product purchased is warranted as follows: Clearfield designed and branded Products are warranted for 

three (3) years: Products manufactured by Clearfield to customer prints and/or specifications are warranted for one (1) year; and any Product Clear

-

field acquires from or through a third-party manufacturer or distributor and resells to Customer as the original customer will carry the manufacturer’s 

pass-through warranty, if any. In all cases, the warranty period commences on the date of shipment to the original purchaser.

Warranty Claim Procedure

If any Product purchased from Clearfield is found defective under the above warranty, the following basic procedure must be followed:

1. 

Customer must contact Clearfield and obtain a Return Materials Authorization

2. 

Following authorization, the Customer ships the product-freight collect-to Clearfield’s manufacturing facility

3. 

Clearfield shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus

-

tomer’s site, freight prepaid

Note: If the Product is not found to be defective by Clearfield, the product will be returned to the Customer and the customer billed for freight in both 

directions.

View our warranty policy here: 

https://www.seeclearfield.com/warranty.html

Limitations of Warranty

Correction of defects by repair or replacement, at the option of Clearfield Inc, shall constitute the exclusive sole remedy for a breach of this limited 

warranty. Clearfield shall not be liable under any circumstances for any special, consequential, incidental, punitive, or exemplary damages arising 

out of or in any way connected with the product or with agreement to sell product to buyer, including, but not limited to damages for lost profits, loss 

of use, or for any damages or sums paid by buyer to third parties. The foregoing limitation of liability shall apply whether the claim is based upon 

principles of contract, warranty, negligence or other tort, breach of statutory duty, principles of indemnity or contribution, the failure of any limited or 

exclusive remedy to achieve its essential purpose, or otherwise.

Clearfield will not be responsible for any labor or materials costs associated with installation or incorporation of Clearfield products at customer sites, 

including any costs of alteration, replacement or defective product, or any field repairs.

Other Limitations

Clearfield assumes no warranty liability regarding defects caused by:

1. 

Customer’s modification of Product, excepting installation activities described in Clearfield documentation

2. 

Customer re-packaging of Product for shipment to third parties or destinations other than those originally shipped to by Clearfield, or any de

-

fects suffered during shipping where the Product has been re-packaged

3. 

Customer’s installation or maintenance, excepting activities described in and performed in accordance with Clearfield documentation

4. 

Customer’s improper or negligent use or application of Product

5. 

Other causes external to the Product, including but not limited to accidents, catastrophe, acts of God, government action, war, riot, strikes, civil 

commotion, sovereign conduct, or the acts or conduct of any person or persons not party to or associated with Clearfield

6. 

Environmental factors and weathering resulting in aging and damage not necessary or applicable to the function of the product

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

12

FieldSmart

®

 Fiber Entrance Cabinet (FEC)

Installation Manual 

 _________________________________________________________

Manual 019612 REV B - Aug 2018

Proprietary Notice

Information contained in this document is copyrighted by Clearfield, Inc. and may not be duplicated in full or part by any person without prior written 

approval of Clearfield, Inc.

Its purpose is to provide the user with adequately detailed documentation to efficiently install the equipment supplied. Every effort has been made to 

keep the information contained in this document current and accurate as of the date of publication or revision. 

However, no guarantee is given or implied that the document is error free or that it is accurate with regard to any specification.

Technical Support

Clearfield, Inc. can be contacted for any issues that arise with the supplied product.

If you need to return the supplied product, you must contact the Clearfield, Inc. Customer Service Department to request a Returned Materials 

Authorization (RMA) number.

Clearfield, Inc.

7050 Winnetka Ave N

Minneapolis, MN 55428

Toll Free:  

800.422.2537

Phone:    

763.476.6866

Fax:  

 

763.475.8457

Customer Support: sales@clfd.net