background image

FieldShield YOURx-TAP

Installation Manual 

 ______________________________________________________

Manual 018446 REV A - AUG 2017

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

2

FieldShield YOURx-TAP

Installation Manual 

 _________________________________________________________

Manual 018446 REV A - AUG 2017

Table of Contents

Product Packaging  

3

Parts List   

3

Required Tools 

 

4

Box Mounting 

 

4

Preparing Ports   

5

Bottom Deploy Reel Installation   

5

Configurations 

 

8

Top Deploy Reel Installation 

 

8

Installing Bulkheads 

 

9

Entering and Exiting Fiber Configurations 

 

10

Storing Slack Fiber on the TAP Slack Reel 

 

11

YOURx-TAP Accessories   

12

Connector Cleaning Procedure   

13

Standard Warranty   

16

Proprietary Notice   

17

Technical Support   

17

 


background image

3

FieldShield YOURx-TAP

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 018446 REV A - AUG 2017

Product Packaging

StrongFiber Deploy Reels are shipped in a bubble wrap packaging 

(Figure 1) 

with mounting 

hardware included in a plastic pouch 

(Figure 2).

Figure 1

Figure 2

Find No.

Quantity

Description

Image

001

1

SmartFiber Deploy Reel

002

1

Back post

003

5

Self Taping Screws

004

1

Cable Entrance Bulkhead

005

1

Blank Bulkhead

Parts List

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

4

FieldShield YOURx-TAP

Installation Manual 

 _________________________________________________________

Manual 018446 REV A - AUG 2017

Figure 1

Step 1: Mount TAP Box 

Use a Philips Screwdriver to attach the back post to wall box or mounting surface 

using the provided self taping screws 

(Figure 1)

Box Mounting

Figure 2

Note: 

A pass through hole is provided on the back of the wall box as an option to 

directly penetrate into the customer premise. 

(Figure 2)

.

If this option is used a 1/4 inch  hole must be drilled into the home prior to mount-

ing the TAP box. It is also recommended that the hole be sleeved with a piece of 

10/6 microduct for unobstructed access into the customer premise.

Find No.

Tool

Image

006

Phillips Scewdriver

007

Deburring Tool

008

Pliers

Required Tools

 


background image

5

FieldShield YOURx-TAP

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 018446 REV A - AUG 2017

Step 1

:

 Install Back Post 

Use a Philips Screwdriver to attach the back post to wall box 

or mounting surface using the provided self taping screws 

(Figure 1). 

Figure 1

Bottom Deploy Reel Installation

Step 2

:

 Mount Deploy Reel 

Align center hole on Deploy Reel with Back Post (Figure 2). The surrounding holes will be used to lock the 

Reel down after installation. Press Deploy Reel onto Back Post (Figure 3).

Figure 2

Figure 3

Step 1

:

 Remove Port Tab

Use a pair of pliers to snap off port tab.

(Figure 1 & Figure 2). 

Step 2

:

 Ream Port

Use appropriate tool (we reccomend deburring tool) 

to ream and chamfer edges of port.
(Figure 3)

Preparing Ports

Figure 1

Figure 2

Figure 3

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

6

FieldShield YOURx-TAP

Installation Manual 

 _________________________________________________________

Manual 018446 REV A - AUG 2017

Step 3

:

 Prepare Pullable SC Connector

Remove the Pullable SC Connector from the reel and remove protective tape (Figure 7). Find the 

integrated pull string on the connector (Figure 8) and make a simple loop/half hitch in the pull string (Figure 

Figure 7

Figure 8

Step 4

:

 Tie Pull String to SC Connector

Loop the pull string around the first notch on the metal crimp tube. (Figure 10 & Figure 11). 

Thread the end of the pull string under itself using a half hitch knot and pull to tighten (Figure 12 & Figure 13).

Figure 9

Figure 13

Figure 10

Figure 12

Figure 11

!

IMPORTANT

 


background image

7

FieldShield YOURx-TAP

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 018446 REV A - AUG 2017

Step 5

:

 Connect Pull Strings

Tie Connector Pull String to Duct Pull String

(Figure 14). 

Figure 14

Figure 15

Step 6

:

 Unlock Deploy Reel

Pull out gently on Deploy Reel to unlock it from 

the backpost (Figure 15). 

Step 7

:

 Insert Connector

Insert Connector fully into duct before 

pulling fiber through. (Figure 16). 

Figure 16

Step 8: Pull Fiber through Duct

Use the Duct Pull String to pull the 

required length of fiber through the 

duct to the network access point. 

Step 9

:

 Assemble Connector End

Once pulled throught the duct, 

assemble the FieldShield Connecter 

following instructions provided with 

the FieldShield Reel. (Figure 17). 

Figure 17

Watch the Installation Video

FieldShield SC Connector

www.clfd.net/media/deployreel.php

DO NOT

 use any type of 

tape when tying the pull 

string to the microduct pull 

string. This will cause friction 

and will result in blockage of 

the microduct.

!

IMPORTANT

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

8

FieldShield YOURx-TAP

Installation Manual 

 _________________________________________________________

Manual 018446 REV A - AUG 2017

Configuration 1

:

 

Bottom: Empty Deploy Reel

Top: StrongFiber Delpoy Reel 

(Figure 1). 

Figure 1

Configurations

The FieldShield YOURx-TAP can be used in the following configurations. 

Figure 2

Figure 3

Configuration 2

:

 

Bottom: StrongFiber Deploy Reel 

Top: StrongFiber Delpoy Reel 

(Figure 2). 

Configuration 3

:

 

Bottom: StrongFiber Deploy Reel

Top: FLEXdrop Slack Reel 

(Figure 3). 

Top Deploy Reel Installation

Figure 2

Step 2

:

 Mount Deploy Reel

Align center hole on Deploy Reel with Back Post. 

Press Deploy Reel onto Back Post (Figure 2).

Figure 2

Step 1

:

 Install Back Post 

Use a Philips Screwdriver to attach the back post 

to bottom Deploy Reel using the provided self 

taping screws (Figure 1). 

Note: Back post cannot be secured to FLEXdrop 

slack reel.

 


background image

9

FieldShield YOURx-TAP

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 018446 REV A - AUG 2017

Figure 1

Installing Bulkheads

The YOURx-TAP is shipped with Qty (1) Cable Entrance Bulkhead (Figure 1) Qty (1) Blank Bulkhead (Figure 2). Additional 

Bulkheads are available for custom configurations. 

Figure 2

INSPECT BEFORE YOU CONNECT!

CLEAN CONNECTOR

DIRTY CONNECTOR

SEE PAGE 13 FOR RECOMMENDED CLEANING PROCEDURES

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

10

FieldShield YOURx-TAP

Installation Manual 

 _________________________________________________________

Manual 018446 REV A - AUG 2017

Figure 1

Step 1

:

 Feed through 

Port

Guide preconnectorized 

fiber (unassembled) into 

YOURx-TAP port and pull 

until hardened connector 

reaches port. 

(Figure 1)

Step 2

:

 Seat Connector

Once fiber is through, 

seat connector into port.

(Figure 2)

Figure 2

Entering and Exiting Fiber Configurations

Fiber can enter or exit the YOURx-TAP through the removable bulkheads at the bottom of the unit, or through the pass 

through port at the back ot the unit.

When entering the YOURx-TAP 

DO NOT

 assemble SC Connector Outer Housing until fiber has been 

passed through the port. Fully connectorized fiber will not pass through port.

!

IMPORTANT

Figure 1

Figure 2

FieldShield Flat-SC

FieldShield D-ROP

Step 1

:

 Feed through 

Port

Guide preconnectorized 

fiber (unassembled) into 

YOURx-TAP port and pull 

until hardened connector 

reaches port. 

(Figure 1)

Step 2

:

 Seat Connector

Once fiber is through, 

seat connector into port.

(Figure 2)

 


background image

11

FieldShield YOURx-TAP

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 018446 REV A - AUG 2017

Figure 1

Figure 2

Figure 1

Figure 2

FieldShield FLEXdrop or FieldShield

FieldShield StrongFiber

Step 1

:

 Install Duct

Seat microduct into 

YOURx-TAP port. 

(Figure 1)

Step 2

:

 Feed through 

Duct

Push or pull fiber 

(unassembled) through 

the duct and into the 

YOURx TAP. 

(Figure 2)

Step 1

:

 Install Duct

Seat microduct into 

YOURx-TAP port and tie 

StrongFiber pull string to 

duct pullstring with double 

knot. 

(Figure 1)

Step 2

:

 Feed through 

Duct

Release deploy reel and 

pull fiber (unassembled) 

out through the duct and 

into the YOURx TAP. 

(Figure 2)

Storing Slack Fiber on the TAP Slack Reel

Up to 50 feet of FieldShield or FieldShield FLEXdrop can be stored on the TAP Slack Reel. 

Figure 1

Figure 2

Step 1

:

 Coil Fiber

Once fiber has been 

terminated in the Strong-

Fiber Deploy Reel, wrap 

excess fiber around the 

the TAP Slack Reel in a 

counter-clockwise motion, 

making sure not to intro-

duce a twist to the fiber.

(Figure 1)

Step 2

:

 Mount Reel

Mount TAP Slack Reel 

onto back post attached 

to StrongFiber Deploy 

Reel. 

(Figure 2)

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

12

FieldShield YOURx-TAP

Installation Manual 

 _________________________________________________________

Manual 018446 REV A - AUG 2017

Part Number

Description

018664

FlexPort Plug, filler for 10mm Cartridges

Part Number

Description

FSX-10MM EXPANSION KIT

Bag of four 10mm FlexPorts and 10mm Plugs

Part Number

Description

016280

FlexPort, Push to Connect, 10mm

Part Number

Description

016280

FlexPort, Push to Connect, 10mm

FS-GBLOCK-10MM-04

Description

Fits around fiber onto duct, providing gas-tight protection. The FS-GBLOCK-10MM-04 

includes 4 - 10mm gas blockers and 4 - 3” of 10mm FieldShield Microduct.

Pre-Configured Part Numbers

FSX-10mm Expansion Kit

Description

Bag of 4 individual FlexPorts (016280) and 4 - 10mm FlexPorts plugs (018664) for securing 

10mm microduct into the YOURx-TAP.

Pre-Configured Part Numbers

10MM Plug

Description

FieldShield FlexPort filler plug for 10mm into the YOURx-TAP. 

Application: Used for sealing FlexPort holes if plug on the inside is removed. 

Pre-Configured Part Numbers

FieldShield FlexPort

Description

Individual FieldShield FlexPort for securing 10mm or 14mm microduct into the FieldShield 

YOURx-Terminal or YOURx-TAP. Includes the outer coupler, inner housing and O-ring.

Pre-Configured Part Numbers

YOURx-TAP Accessories

 


background image

13

FieldShield YOURx-TAP

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 018446 REV A - AUG 2017

Whether factory terminated or field spliced, clean connectors are essential 

for proper system operation. Even the smallest dust particle can cause 

transmission problems, so for optimal network performance, inspect and if 

necessary, clean all connectors and adapters prior to mating.

I.B.Y.C…Inspect Before You Connect!

 

ALWAYS inspect the connector first thing with a clean fiber scope inspect 

the pair. Three types of contamination require different cleaning techniques. 

The use of Chemtronics end face and bulkhead cleaning products and 

techniques ensures a clean end face, no matter the type of contamination.

These are Clearfield recommended products/application. Use the product 

you feel will complete your cleaning procedures. Create a “best practice” for 

your company and follow those procedures.

**NOTE: It is NOT recommended to use IPA to clean the end-face.

Cleaning the end-face…but not just the end-face

• Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen. 

Figure 1

• Apply small amount of precision cleaner (about 1” in diameter) with Elec-

tro-Wash MX pen on to one end of the wipe. 

Figure 2

• Hold end face 90 degree. Adjust for APC connection by slightly tilting the 

container or end face. Angle is correct when no drag is left on the end face. 

Figure 3

• Draw end face from wet to dry part of the wipe 3 times. Use just enough 

pressure to ensure complete contact between end face and the wipe.  

DO NOT

 retrace previous step.

Figure 1

Figure 2

Figure 3

Connector Cleaning Procedure

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

14

FieldShield YOURx-TAP

Installation Manual 

 _________________________________________________________

Manual 018446 REV A - AUG 2017

• 

CLEAN THE FERRULE

…Lightly moisten the fiber optic swab 

(2.5mm/38542F or 1.25mm/38040) by spotting a small amount (about 

1”) of Electro-Wash PX or Electro-Wash MX pen onto the Qbe. Hold the 

swab, 1 side down to the wetted area and hold for a count of 1-2-3-4-5. 

Figure 4

• Insert swab into side of ferrule, wet side to the ceramic ferrule and 

circle around 2-3 times and remove. Turn swab to dry side and repeat. 

Figure 5

Cleaning the mate through a bulkhead adapter AND the 

adapter itself!

• Lightly moisten the fiber optic swab(2.5mm/38542F or 1.25mm/38040) 

by spotting a small amount (about 1”) of Electro-Wash PX or Elec-

tro-Wash MX pen onto the Qbe. Hold the tip of the swab onto the wetted 

area and hold for a count of 1-2-3-4-5.

• Insert the swab into the adapter to the connector, press lightly against 

the connector, twist 2-3 times, remove and discard.

• Dry with a second dry swab.

• Inspect (re-clean if necessary) and test for signal strength.

• Use additional swabs to clean inside the actual adapter. Moisten swab, 

like above, insert through hole and remove while twisting. 

Figure 6

Figure 4

Figure 5

Figure 6

 


background image

15

FieldShield YOURx-TAP

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 018446 REV A - AUG 2017

Cleaning an MPO/MTP Connector

Female Connector

• Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen and 

apply small amount of precision cleaner (about 1” in diameter) with Elec-

tro-Wash MX pen on to one end of the wipe. 

Figure 1

• Hold end face 90 degree. Adjust for APC connection by slightly tilting 

the container or end face. Angle is correct when no drag is left on the end 

face. 

Figure 2

Male Connector

• Lightly moisten the fiber optic swab (CC505F) like above, moistening 1 

side.

• Place swab, wet side down at one end of connector end-face and draw 

across in a diagonal sweep (ie: from fiber 1 up and across to fiber 12). 

Turn swab over to dry and draw back from fiber 12 to fiber 1. 

Figure 3

BEFORE cleaning any connector…be sure you know what type of con-

taminate you are cleaning…dry? Fluidic?...All the available products are 

good, it’s the process that you need to be aware of. Using a dry cleaning 

method to clean “dirt” can lead to scratching of the end-face. Learn the 

process of cleaning properly!

Figure 1

Figure 2

Figure 3

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

16

FieldShield YOURx-TAP

Installation Manual 

 _________________________________________________________

Manual 018446 REV A - AUG 2017

Standard Warranty

Clearfield warrants to the original purchaser of the Product sold hereunder is free from defects in material and workmanship under normal use and 

service, subject to exceptions stated herein. Product purchased is warranted as follows: Clearfield designed and branded Products are warranted for 

five (5) years: Products manufactured by Clearfield to customer prints and/or specifications are warranted for one (1) year; and any Product Clear-

field acquires from or through a third-party manufacturer or distributor and resells to Customer as the original customer will carry the manufacturer’s 

pass-through warranty, if any. In all cases, the warranty period commences on the date of shipment to the original purchaser.

Warranty Claim Procedure

If any Product purchased from Clearfield is found defective under the above warranty, the following basic procedure must be followed:

1.  Customer must contact Clearfield and obtain a Return Materials Authorization

2.  Following authorization, the Customer ships the product-freight collect-to Clearfield’s manufacturing facility

3.  Clearfield shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus-

tomer’s site, freight prepaid

Note: If the Product is not found to be defective at Clearfield, the product will be returned to the Customer and the customer billed for freight in both 

directions.

Limitations of Warranty

Correction of defects by repair or replacement, at the option of Clearfield Inc, shall constitute the exclusive sole remedy for a breach of this limited 

warranty. Clearfield shall not be liable under any circumstances for any special, consequential, incidental, punitive, or exemplary damages arising 

out of or in any way connected with the product or with agreement to sell product to buyer, including, but not limited to damages for lost profits, loss 

of use, or for any damages or sums paid by buyer to third parties. The foregoing limitation of liability shall apply whether the claim is based upon 

principles of contract, warranty, negligence or other tort, breach of statutory duty, principles of indemnity or contribution, the failure of any limited or 

exclusive remedy to achieve its essential purpose, or otherwise.

Clearfield will not be responsible for any labor or materials costs associated with installation or incorporation of Clearfield products at customer sites, 

including any costs of alteration, replacement or defective product, or any field repairs.

Other Limitations

1.  Clearfield assumes no warranty liability regarding defects caused by:

2.  Customer’s modification of Product, excepting installation activities described in Clearfield documentation

3.  Customer re-packaging of Product for shipment to third parties or destinations other than those originally shipped to by Clearfield, or any de-

fects suffered during shipping where the Product has been re-packaged

4.  Customer’s installation or maintenance, excepting activities described in and performed in accordance with Clearfield documentation

5.  Customer’s improper or negligent use or application of Product

6.  Other causes external to the Product, including but not limited to accidents, catastrophe, acts of God, government action, war, riot, strikes, civil 

commotion, sovereign conduct, or the acts or conduct of any person or persons not party to or associated with Clearfield

 


background image

17

FieldShield YOURx-TAP

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 018446 REV A - AUG 2017

Proprietary Notice

About FieldShield Product Line Application

Information contained in this document is copyrighted by Clearfield, Inc. and may not be duplicated in full or part by any person without prior written 

approval of Clearfield, Inc.

Its purpose is to provide the user with adequately detailed documentation to efficiently install the equipment supplied. Every effort has been made to 

keep the information contained in this document current and accurate as of the date of publication or revision. 

However, no guarantee is given or implied that the document is error free or that it is accurate with regard to any specification.

Technical Support

Clearfield, Inc. can be contacted for any issues that arise with the supplied product.

If you need to return the supplied product, you must contact the Clearfield, Inc. Customer Service Department to request a Returned Materials 

Authorization (RMA) number.

Clearfield, Inc.

7050 Winnetka Ave N

Minneapolis, MN 55428

Toll Free:  

800.422.2537

Phone:    

763.476.6866

Fax:  

 

763.475.8457

Customer Support: sales@clfd.net

Technical Support:  techsupport@clfd.net