FieldShield YOURx-TAP
Installation Manual
______________________________________________________
Manual 018446 REV A - AUG 2017

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
2
FieldShield YOURx-TAP
Installation Manual
_________________________________________________________
Manual 018446 REV A - AUG 2017
Table of Contents
Product Packaging
3
Parts List
3
Required Tools
4
Box Mounting
4
Preparing Ports
5
Bottom Deploy Reel Installation
5
Configurations
8
Top Deploy Reel Installation
8
Installing Bulkheads
9
Entering and Exiting Fiber Configurations
10
Storing Slack Fiber on the TAP Slack Reel
11
YOURx-TAP Accessories
12
Connector Cleaning Procedure
13
Standard Warranty
16
Proprietary Notice
17
Technical Support
17

3
FieldShield YOURx-TAP
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 018446 REV A - AUG 2017
Product Packaging
StrongFiber Deploy Reels are shipped in a bubble wrap packaging
(Figure 1)
with mounting
hardware included in a plastic pouch
(Figure 2).
Figure 1
Figure 2
Find No.
Quantity
Description
Image
001
1
SmartFiber Deploy Reel
002
1
Back post
003
5
Self Taping Screws
004
1
Cable Entrance Bulkhead
005
1
Blank Bulkhead
Parts List

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
4
FieldShield YOURx-TAP
Installation Manual
_________________________________________________________
Manual 018446 REV A - AUG 2017
Figure 1
Step 1: Mount TAP Box
Use a Philips Screwdriver to attach the back post to wall box or mounting surface
using the provided self taping screws
(Figure 1)
.
Box Mounting
Figure 2
Note:
A pass through hole is provided on the back of the wall box as an option to
directly penetrate into the customer premise.
(Figure 2)
.
If this option is used a 1/4 inch hole must be drilled into the home prior to mount-
ing the TAP box. It is also recommended that the hole be sleeved with a piece of
10/6 microduct for unobstructed access into the customer premise.
Find No.
Tool
Image
006
Phillips Scewdriver
007
Deburring Tool
008
Pliers
Required Tools

5
FieldShield YOURx-TAP
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 018446 REV A - AUG 2017
Step 1
:
Install Back Post
Use a Philips Screwdriver to attach the back post to wall box
or mounting surface using the provided self taping screws
(Figure 1).
Figure 1
Bottom Deploy Reel Installation
Step 2
:
Mount Deploy Reel
Align center hole on Deploy Reel with Back Post (Figure 2). The surrounding holes will be used to lock the
Reel down after installation. Press Deploy Reel onto Back Post (Figure 3).
Figure 2
Figure 3
Step 1
:
Remove Port Tab
Use a pair of pliers to snap off port tab.
(Figure 1 & Figure 2).
Step 2
:
Ream Port
Use appropriate tool (we reccomend deburring tool)
to ream and chamfer edges of port.
(Figure 3)
Preparing Ports
Figure 1
Figure 2
Figure 3

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
6
FieldShield YOURx-TAP
Installation Manual
_________________________________________________________
Manual 018446 REV A - AUG 2017
Step 3
:
Prepare Pullable SC Connector
Remove the Pullable SC Connector from the reel and remove protective tape (Figure 7). Find the
integrated pull string on the connector (Figure 8) and make a simple loop/half hitch in the pull string (Figure
Figure 7
Figure 8
Step 4
:
Tie Pull String to SC Connector
Loop the pull string around the first notch on the metal crimp tube. (Figure 10 & Figure 11).
Thread the end of the pull string under itself using a half hitch knot and pull to tighten (Figure 12 & Figure 13).
Figure 9
Figure 13
Figure 10
Figure 12
Figure 11
!
IMPORTANT

7
FieldShield YOURx-TAP
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 018446 REV A - AUG 2017
Step 5
:
Connect Pull Strings
Tie Connector Pull String to Duct Pull String
(Figure 14).
Figure 14
Figure 15
Step 6
:
Unlock Deploy Reel
Pull out gently on Deploy Reel to unlock it from
the backpost (Figure 15).
Step 7
:
Insert Connector
Insert Connector fully into duct before
pulling fiber through. (Figure 16).
Figure 16
Step 8: Pull Fiber through Duct
Use the Duct Pull String to pull the
required length of fiber through the
duct to the network access point.
Step 9
:
Assemble Connector End
Once pulled throught the duct,
assemble the FieldShield Connecter
following instructions provided with
the FieldShield Reel. (Figure 17).
Figure 17
Watch the Installation Video
FieldShield SC Connector
www.clfd.net/media/deployreel.php
DO NOT
use any type of
tape when tying the pull
string to the microduct pull
string. This will cause friction
and will result in blockage of
the microduct.
!
IMPORTANT

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
8
FieldShield YOURx-TAP
Installation Manual
_________________________________________________________
Manual 018446 REV A - AUG 2017
Configuration 1
:
Bottom: Empty Deploy Reel
Top: StrongFiber Delpoy Reel
(Figure 1).
Figure 1
Configurations
The FieldShield YOURx-TAP can be used in the following configurations.
Figure 2
Figure 3
Configuration 2
:
Bottom: StrongFiber Deploy Reel
Top: StrongFiber Delpoy Reel
(Figure 2).
Configuration 3
:
Bottom: StrongFiber Deploy Reel
Top: FLEXdrop Slack Reel
(Figure 3).
Top Deploy Reel Installation
Figure 2
Step 2
:
Mount Deploy Reel
Align center hole on Deploy Reel with Back Post.
Press Deploy Reel onto Back Post (Figure 2).
Figure 2
Step 1
:
Install Back Post
Use a Philips Screwdriver to attach the back post
to bottom Deploy Reel using the provided self
taping screws (Figure 1).
Note: Back post cannot be secured to FLEXdrop
slack reel.

9
FieldShield YOURx-TAP
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 018446 REV A - AUG 2017
Figure 1
Installing Bulkheads
The YOURx-TAP is shipped with Qty (1) Cable Entrance Bulkhead (Figure 1) Qty (1) Blank Bulkhead (Figure 2). Additional
Bulkheads are available for custom configurations.
Figure 2
INSPECT BEFORE YOU CONNECT!
CLEAN CONNECTOR
DIRTY CONNECTOR
SEE PAGE 13 FOR RECOMMENDED CLEANING PROCEDURES

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
10
FieldShield YOURx-TAP
Installation Manual
_________________________________________________________
Manual 018446 REV A - AUG 2017
Figure 1
Step 1
:
Feed through
Port
Guide preconnectorized
fiber (unassembled) into
YOURx-TAP port and pull
until hardened connector
reaches port.
(Figure 1)
.
Step 2
:
Seat Connector
Once fiber is through,
seat connector into port.
(Figure 2)
.
Figure 2
Entering and Exiting Fiber Configurations
Fiber can enter or exit the YOURx-TAP through the removable bulkheads at the bottom of the unit, or through the pass
through port at the back ot the unit.
When entering the YOURx-TAP
DO NOT
assemble SC Connector Outer Housing until fiber has been
passed through the port. Fully connectorized fiber will not pass through port.
!
IMPORTANT
Figure 1
Figure 2
FieldShield Flat-SC
FieldShield D-ROP
Step 1
:
Feed through
Port
Guide preconnectorized
fiber (unassembled) into
YOURx-TAP port and pull
until hardened connector
reaches port.
(Figure 1)
.
Step 2
:
Seat Connector
Once fiber is through,
seat connector into port.
(Figure 2)
.

11
FieldShield YOURx-TAP
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 018446 REV A - AUG 2017
Figure 1
Figure 2
Figure 1
Figure 2
FieldShield FLEXdrop or FieldShield
FieldShield StrongFiber
Step 1
:
Install Duct
Seat microduct into
YOURx-TAP port.
(Figure 1)
.
Step 2
:
Feed through
Duct
Push or pull fiber
(unassembled) through
the duct and into the
YOURx TAP.
(Figure 2)
.
Step 1
:
Install Duct
Seat microduct into
YOURx-TAP port and tie
StrongFiber pull string to
duct pullstring with double
knot.
(Figure 1)
.
Step 2
:
Feed through
Duct
Release deploy reel and
pull fiber (unassembled)
out through the duct and
into the YOURx TAP.
(Figure 2)
.
Storing Slack Fiber on the TAP Slack Reel
Up to 50 feet of FieldShield or FieldShield FLEXdrop can be stored on the TAP Slack Reel.
Figure 1
Figure 2
Step 1
:
Coil Fiber
Once fiber has been
terminated in the Strong-
Fiber Deploy Reel, wrap
excess fiber around the
the TAP Slack Reel in a
counter-clockwise motion,
making sure not to intro-
duce a twist to the fiber.
(Figure 1)
.
Step 2
:
Mount Reel
Mount TAP Slack Reel
onto back post attached
to StrongFiber Deploy
Reel.
(Figure 2)
.

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
12
FieldShield YOURx-TAP
Installation Manual
_________________________________________________________
Manual 018446 REV A - AUG 2017
Part Number
Description
018664
FlexPort Plug, filler for 10mm Cartridges
Part Number
Description
FSX-10MM EXPANSION KIT
Bag of four 10mm FlexPorts and 10mm Plugs
Part Number
Description
016280
FlexPort, Push to Connect, 10mm
Part Number
Description
016280
FlexPort, Push to Connect, 10mm
FS-GBLOCK-10MM-04
Description
Fits around fiber onto duct, providing gas-tight protection. The FS-GBLOCK-10MM-04
includes 4 - 10mm gas blockers and 4 - 3” of 10mm FieldShield Microduct.
Pre-Configured Part Numbers
FSX-10mm Expansion Kit
Description
Bag of 4 individual FlexPorts (016280) and 4 - 10mm FlexPorts plugs (018664) for securing
10mm microduct into the YOURx-TAP.
Pre-Configured Part Numbers
10MM Plug
Description
FieldShield FlexPort filler plug for 10mm into the YOURx-TAP.
Application: Used for sealing FlexPort holes if plug on the inside is removed.
Pre-Configured Part Numbers
FieldShield FlexPort
Description
Individual FieldShield FlexPort for securing 10mm or 14mm microduct into the FieldShield
YOURx-Terminal or YOURx-TAP. Includes the outer coupler, inner housing and O-ring.
Pre-Configured Part Numbers
YOURx-TAP Accessories

13
FieldShield YOURx-TAP
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 018446 REV A - AUG 2017
Whether factory terminated or field spliced, clean connectors are essential
for proper system operation. Even the smallest dust particle can cause
transmission problems, so for optimal network performance, inspect and if
necessary, clean all connectors and adapters prior to mating.
I.B.Y.C…Inspect Before You Connect!
ALWAYS inspect the connector first thing with a clean fiber scope inspect
the pair. Three types of contamination require different cleaning techniques.
The use of Chemtronics end face and bulkhead cleaning products and
techniques ensures a clean end face, no matter the type of contamination.
These are Clearfield recommended products/application. Use the product
you feel will complete your cleaning procedures. Create a “best practice” for
your company and follow those procedures.
**NOTE: It is NOT recommended to use IPA to clean the end-face.
Cleaning the end-face…but not just the end-face
• Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen.
Figure 1
• Apply small amount of precision cleaner (about 1” in diameter) with Elec-
tro-Wash MX pen on to one end of the wipe.
Figure 2
• Hold end face 90 degree. Adjust for APC connection by slightly tilting the
container or end face. Angle is correct when no drag is left on the end face.
Figure 3
• Draw end face from wet to dry part of the wipe 3 times. Use just enough
pressure to ensure complete contact between end face and the wipe.
DO NOT
retrace previous step.
Figure 1
Figure 2
Figure 3
Connector Cleaning Procedure

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
14
FieldShield YOURx-TAP
Installation Manual
_________________________________________________________
Manual 018446 REV A - AUG 2017
•
CLEAN THE FERRULE
…Lightly moisten the fiber optic swab
(2.5mm/38542F or 1.25mm/38040) by spotting a small amount (about
1”) of Electro-Wash PX or Electro-Wash MX pen onto the Qbe. Hold the
swab, 1 side down to the wetted area and hold for a count of 1-2-3-4-5.
Figure 4
• Insert swab into side of ferrule, wet side to the ceramic ferrule and
circle around 2-3 times and remove. Turn swab to dry side and repeat.
Figure 5
Cleaning the mate through a bulkhead adapter AND the
adapter itself!
• Lightly moisten the fiber optic swab(2.5mm/38542F or 1.25mm/38040)
by spotting a small amount (about 1”) of Electro-Wash PX or Elec-
tro-Wash MX pen onto the Qbe. Hold the tip of the swab onto the wetted
area and hold for a count of 1-2-3-4-5.
• Insert the swab into the adapter to the connector, press lightly against
the connector, twist 2-3 times, remove and discard.
• Dry with a second dry swab.
• Inspect (re-clean if necessary) and test for signal strength.
• Use additional swabs to clean inside the actual adapter. Moisten swab,
like above, insert through hole and remove while twisting.
Figure 6
Figure 4
Figure 5
Figure 6

15
FieldShield YOURx-TAP
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 018446 REV A - AUG 2017
Cleaning an MPO/MTP Connector
Female Connector
• Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen and
apply small amount of precision cleaner (about 1” in diameter) with Elec-
tro-Wash MX pen on to one end of the wipe.
Figure 1
• Hold end face 90 degree. Adjust for APC connection by slightly tilting
the container or end face. Angle is correct when no drag is left on the end
face.
Figure 2
Male Connector
• Lightly moisten the fiber optic swab (CC505F) like above, moistening 1
side.
• Place swab, wet side down at one end of connector end-face and draw
across in a diagonal sweep (ie: from fiber 1 up and across to fiber 12).
Turn swab over to dry and draw back from fiber 12 to fiber 1.
Figure 3
BEFORE cleaning any connector…be sure you know what type of con-
taminate you are cleaning…dry? Fluidic?...All the available products are
good, it’s the process that you need to be aware of. Using a dry cleaning
method to clean “dirt” can lead to scratching of the end-face. Learn the
process of cleaning properly!
Figure 1
Figure 2
Figure 3

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
16
FieldShield YOURx-TAP
Installation Manual
_________________________________________________________
Manual 018446 REV A - AUG 2017
Standard Warranty
Clearfield warrants to the original purchaser of the Product sold hereunder is free from defects in material and workmanship under normal use and
service, subject to exceptions stated herein. Product purchased is warranted as follows: Clearfield designed and branded Products are warranted for
five (5) years: Products manufactured by Clearfield to customer prints and/or specifications are warranted for one (1) year; and any Product Clear-
field acquires from or through a third-party manufacturer or distributor and resells to Customer as the original customer will carry the manufacturer’s
pass-through warranty, if any. In all cases, the warranty period commences on the date of shipment to the original purchaser.
Warranty Claim Procedure
If any Product purchased from Clearfield is found defective under the above warranty, the following basic procedure must be followed:
1. Customer must contact Clearfield and obtain a Return Materials Authorization
2. Following authorization, the Customer ships the product-freight collect-to Clearfield’s manufacturing facility
3. Clearfield shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus-
tomer’s site, freight prepaid
Note: If the Product is not found to be defective at Clearfield, the product will be returned to the Customer and the customer billed for freight in both
directions.
Limitations of Warranty
Correction of defects by repair or replacement, at the option of Clearfield Inc, shall constitute the exclusive sole remedy for a breach of this limited
warranty. Clearfield shall not be liable under any circumstances for any special, consequential, incidental, punitive, or exemplary damages arising
out of or in any way connected with the product or with agreement to sell product to buyer, including, but not limited to damages for lost profits, loss
of use, or for any damages or sums paid by buyer to third parties. The foregoing limitation of liability shall apply whether the claim is based upon
principles of contract, warranty, negligence or other tort, breach of statutory duty, principles of indemnity or contribution, the failure of any limited or
exclusive remedy to achieve its essential purpose, or otherwise.
Clearfield will not be responsible for any labor or materials costs associated with installation or incorporation of Clearfield products at customer sites,
including any costs of alteration, replacement or defective product, or any field repairs.
Other Limitations
1. Clearfield assumes no warranty liability regarding defects caused by:
2. Customer’s modification of Product, excepting installation activities described in Clearfield documentation
3. Customer re-packaging of Product for shipment to third parties or destinations other than those originally shipped to by Clearfield, or any de-
fects suffered during shipping where the Product has been re-packaged
4. Customer’s installation or maintenance, excepting activities described in and performed in accordance with Clearfield documentation
5. Customer’s improper or negligent use or application of Product
6. Other causes external to the Product, including but not limited to accidents, catastrophe, acts of God, government action, war, riot, strikes, civil
commotion, sovereign conduct, or the acts or conduct of any person or persons not party to or associated with Clearfield

17
FieldShield YOURx-TAP
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 018446 REV A - AUG 2017
Proprietary Notice
About FieldShield Product Line Application
Information contained in this document is copyrighted by Clearfield, Inc. and may not be duplicated in full or part by any person without prior written
approval of Clearfield, Inc.
Its purpose is to provide the user with adequately detailed documentation to efficiently install the equipment supplied. Every effort has been made to
keep the information contained in this document current and accurate as of the date of publication or revision.
However, no guarantee is given or implied that the document is error free or that it is accurate with regard to any specification.
Technical Support
Clearfield, Inc. can be contacted for any issues that arise with the supplied product.
If you need to return the supplied product, you must contact the Clearfield, Inc. Customer Service Department to request a Returned Materials
Authorization (RMA) number.
Clearfield, Inc.
7050 Winnetka Ave N
Minneapolis, MN 55428
Toll Free:
800.422.2537
Phone:
763.476.6866
Fax:
763.475.8457
Customer Support: sales@clfd.net
Technical Support: techsupport@clfd.net