background image

Clearview Black Cassette

Installation Manual 

 ______________________________________________________

Manual 019390 Rev A - Dec 2017

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

2

Clearview Black Cassette

Installation Manual 

 _________________________________________________________

Manual 019390 Rev A - Dec 2017

Table of Contents

Application  

3

Description  

3

Technical Specifications

  

3

Configurations

  

4

Splicing in the Clearview Black Cassette

  

5

Connector Cleaning Procedure

  

14

Standard Warranty

  

17

Proprietary Notice

  

18

Technical Support

  

18

 


background image

3

Clearview Black Cassette 

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019390 Rev A - Dec 2017

Clearview Black incorporates the same flexibility and scalability of both the Clearview Classic and Clearview Blue in a 50% 

smaller footprint than the Clearview Blue. Decreasing the overall footprint of the fiber management element reduces real 

estate costs and improves density without compromising critical design elements of access, bend-radius protection, physical 

fiber protection and route-path diversity. 

Clearview Black is a three component tool-less system made up of a top cover, base/splice tray and splice tray cover. Parts 

snap together to support the desired application requirements. All types of fiber cable construction can be integrated within 

the cassette to support all patch and splice, patch only, plug-and-play, and passive optical component hardware scenarios. 

Each patch and splice cassette comes prepared for mass fusion splicing, with one meter of ribbonized 250 μm fiber 

preloaded and prepped to splice. Each ribbonizing jig aligns and secures the loose tube fibers into correct color code order, 

allowing ribbonizing to be completed quickly and easily. 

For patch only configurations, the pre-terminated length of OSP or IFC cable is pre-loaded within the Clearview Black 

Cassette. The cassettes are then preloaded into the FieldSmart® product when shipped.

Technical Specifications

Clearview Black provides 12 to 24 ports of connectivity for patch 

and splice, patch only and plug-and-play (MPO/MTP) configurations 

in any network environment. It scales and multiplies to meet your 

specific port density and application needs. Additionally, optical 

components integrate into the cassette, supporting any input/output 

combination of splitting or WDM strategy desired.

Description

Application

Clearview Black Cassette

Dimension

0.81’ H x 6.13” W x 4.14” D

Ratings 

Terminations are designed and tested to Telcordia GR-326; Clearfield® FiberDeep® 

Guarantee: 0.2 dB insertion loss or less, exceeding industry standards

Backwards Compatible

N/A

Material

Polycarbonate

Connector Types

Supports industry standard SC and LC singlemode connectors

Meters/Feet of Slack 

Storage

1 meter of 250 μm used for internal ribbon splicing only

Mounting Options

Used with FieldSmart® BLG Pivot Bracket

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

4

Clearview Black Cassette

Installation Manual 

 _________________________________________________________

Manual 019390 Rev A - Dec 2017

Configurations

Patch and Splice: Ribbon

The splice tray that is molded into the 

lower tray is all that is needed to deliver 

integrated in-cassette splicing applications. 

Pre-loaded with up to one meter of ribbon, 

250 μm assemblies that are preterminated 

with slack stored inside the cassette for 

splicing.

Optical Components

Clearview integrates optical components 

into the identical cassette, allowing service 

providers to mix and match fiber modules 

with optical components in the same 

chassis. Options include circulators, WDM 

and splitters up to 1x8 split.

MPO Plug-and-Play

MPO to 12-fiber 900 μm assembly allows 

for plug-and-play by mating MPO to MPO 

with pre-terminated multi-fiber OSP or IFC.

Patch Only

Regardless of the industry standard 

adapters or cable construction, the 

Clearview Black handles all patch only 

applications using the lower tray, top cover 

and built in radius limiter.

 


background image

5

Clearview Black Cassette 

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019390 Rev A - Dec 2017

Splicing in the Clearview Black Cassette

Exit positions as seen from the top of the Clearview 

Black Cassette.

Left Exit

Right Exit

Lift the locking tab to unlatch and remove the bottom 

cassette cover. Remove the strain-relief boot from the 

cassette.

Left Exit

Right Exit

Exit positions as seen from the bottom of the Clearview 

Black Cassette.

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

6

Clearview Black Cassette

Installation Manual 

 _________________________________________________________

Manual 019390 Rev A - Dec 2017

Route the ribbon through the splice sleeve holder and trim 

any excess to the left. This will ensure that the ribbon lays 

well when the splice sleeve is inserted into the holder.

Loop a cable tie or a length of wax string through the 

cassette on the desired exit side.

Gently remove the ribbon from the splice tray.

 


background image

7

Clearview Black Cassette 

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019390 Rev A - Dec 2017

Load the splice sleeve onto the end of the fanout ribbon.

Load the strain relief boot onto the cable being 

spliced. Open up the buffer tube 36” back from the 

end and expose the 250 micron fibers.

Wrap a piece of grommet tape ¼” from the end of the 

jacket and cut the excess.

Loose Tube

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

8

Clearview Black Cassette

Installation Manual 

 _________________________________________________________

Manual 019390 Rev A - Dec 2017

If splicing loose tube, ribbonize the fibers. Proceed to 

splicing the fanout to the cable.

Note: 

If utilizing the Clearview Ribbonizing Tool, reference 

the Clearview Ribbonizing Tool Demonstration Video at 

www.seeclearfield.com under the Resources tab. 

Viewable here: 

https://vimeo.com/212654098

Ribbon

If splicing ribbon into the cassette, slide the strain relief 

boot over the end of the ribbon and push it back over 36”.

Note: 

Clearfield recommends the use of furcation tubing 

to protect the bare ribbon before it enters the cassette. 

Furcation tubing is secured in the cassette in the same 

way as a buffer tube.

Slide the ribbon tie-down over the end of the ribbon and 

push it back 36”.

 


background image

9

Clearview Black Cassette 

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019390 Rev A - Dec 2017

After splicing, begin routing the ribbon counterclockwise 

into the splice tray. Rotate the cassette as you load the 

ribbon since the cable will have to remain stationary.

Secure the ribbon tie-down in place by heating it in the 

splicer oven. Proceed to splicing the fanout to the cable.

Before you load the spliced portion into the splice tray, 

route the ribbon under the first tab below the transition as 

shown.

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

10

Clearview Black Cassette

Installation Manual 

 _________________________________________________________

Manual 019390 Rev A - Dec 2017

Insert the spliced portion into the splice sleeve holder 

as shown.

Note: 

Do not force the splice sleeve into holder. If 

necessary, slide the sleeve in from either side as 

shown.

Route the remainder of the fiber under the tabs 

underneath the splice sleeve as shown.

 


background image

11

Clearview Black Cassette 

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019390 Rev A - Dec 2017

For a left exit, route the fiber as shown. Insert the boot into 

the cassette and align the grommet tape with the cable tie 

or wax string.

For a right exit, route the fibers through the redirect channel 

and loop in the opposite direction.

Continue routing the fiber around the the track.

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

12

Clearview Black Cassette

Installation Manual 

 _________________________________________________________

Manual 019390 Rev A - Dec 2017

Insert the boot into the boot retainer and align the 

grommet tape with the cable tie or wax string.

Secure the fiber by tightening the cable tie or tying the 

wax string in a double knot.

If you are splicing with a ribbon fiber, slide the boot up the 

ribbon and align the ribbon tie-down with the cable tie or 

wax string.

 


background image

13

Clearview Black Cassette 

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019390 Rev A - Dec 2017

Press the cassette cover down until the locking tab latches 

in the rear of the cassette. Ensure that no fibers get pinched 

in the lid. Verify the cassette cover closes flat and evenly 

onto the cassette.

Insert the tabs of the cassette cover into the holes in the 

bottom of the splice tray.

Insert the strain relief boot into the boot retainer and use 

the cable tie or wax string to secure the ribbon tie-down 

into place.

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

14

Clearview Black Cassette

Installation Manual 

 _________________________________________________________

Manual 019390 Rev A - Dec 2017

Whether factory terminated or field spliced, clean connectors are essential 

for proper system operation. Even the smallest dust particle can cause 

transmission problems, so for optimal network performance, inspect and if 

necessary, clean all connectors and adapters prior to mating.

I.B.Y.C…Inspect Before You Connect!

 

ALWAYS inspect the connector first thing with a clean fiber scope inspect 

the pair. Three types of contamination require different cleaning techniques. 

The use of Chemtronics end face and bulkhead cleaning products and 

techniques ensures a clean end face, no matter the type of contamination.

These are Clearfield recommended products/application. Use the product 

you feel will complete your cleaning procedures. Create a “best practice” for 

your company and follow those procedures.

**NOTE: It is NOT recommended to use IPA to clean the end-face.

Cleaning the end-face…but not just the end-face

• Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen. 

Figure 1

• Apply small amount of precision cleaner (about 1” in diameter) with Elec

-

tro-Wash MX pen on to one end of the wipe. 

Figure 2

• Hold end face 90 degree. Adjust for APC connection by slightly tilting the 

container or end face. Angle is correct when no drag is left on the end face. 

Figure 3

• Draw end face from wet to dry part of the wipe 3 times. Use just enough 

pressure to ensure complete contact between end face and the wipe.  

DO NOT

 retrace previous step.

Figure 1

Figure 2

Figure 3

Connector Cleaning Procedure

 


background image

15

Clearview Black Cassette 

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019390 Rev A - Dec 2017

• 

CLEAN THE FERRULE

…Lightly moisten the fiber optic swab 

(2.5mm/38542F or 1.25mm/38040) by spotting a small amount (about 1”) 

of Electro-Wash PX or Electro-Wash MX pen onto the QBE-2. Hold the 

swab, 1 side down to the wetted area and hold for a count of 1-2-3-4-5. 

Figure 4

• Insert swab into side of ferrule, wet side to the ceramic ferrule and 

circle around 2-3 times and remove. Turn swab to dry side and repeat. 

Figure 5

Cleaning the mate through a bulkhead adapter AND the 

adapter itself!

• Lightly moisten the fiber optic swab(2.5mm/38542F or 1.25mm/38040) 

by spotting a small amount (about 1”) of Electro-Wash PX or Elec

-

tro-Wash MX pen onto the QBE-2. Hold the tip of the swab onto the 

wetted area and hold for a count of 1-2-3-4-5.

• Insert the swab into the adapter to the connector, press lightly against 

the connector, twist 2-3 times, remove and discard.

• Dry with a second dry swab.

• Inspect (re-clean if necessary) and test for signal strength.

• Use additional swabs to clean inside the actual adapter. Moisten swab, 

like above, insert through hole and remove while twisting. 

Figure 6

Figure 4

Figure 5

Figure 6

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

16

Clearview Black Cassette

Installation Manual 

 _________________________________________________________

Manual 019390 Rev A - Dec 2017

Cleaning an MPO/MTP Connector

Female Connector

• Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen and 

apply small amount of precision cleaner (about 1” in diameter) with Elec

-

tro-Wash MX pen on to one end of the wipe. 

Figure 1

• Hold end face 90 degree. Adjust for APC connection by slightly tilting 

the container or end face. Angle is correct when no drag is left on the end 

face. 

Figure 2

Male Connector

• Lightly moisten the fiber optic swab (CC505F) like above, moistening 1 

side.

• Place swab, wet side down at one end of connector end-face and draw 

across in a diagonal sweep (ie: from fiber 1 up and across to fiber 12). 

Turn swab over to dry and draw back from fiber 12 to fiber 1. 

Figure 3

BEFORE cleaning any connector…be sure you know what type of con

-

taminate you are cleaning…dry? Fluidic?...All the available products are 

good, it’s the process that you need to be aware of. Using a dry cleaning 

method to clean “dirt” can lead to scratching of the end-face. Learn the 

process of cleaning properly!

Figure 1

Figure 2

Figure 3

 


background image

17

Clearview Black Cassette 

__________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

Manual 019390 Rev A - Dec 2017

Standard Warranty

Clearfield warrants to the original purchaser of the Product sold hereunder is free from defects in material and workmanship under normal use and 

service, subject to exceptions stated herein. Product purchased is warranted as follows: Clearfield designed and branded Products are warranted for 

three (3) years: Products manufactured by Clearfield to customer prints and/or specifications are warranted for one (1) year; and any Product Clear

-

field acquires from or through a third-party manufacturer or distributor and resells to Customer as the original customer will carry the manufacturer’s 

pass-through warranty, if any. In all cases, the warranty period commences on the date of shipment to the original purchaser.

Warranty Claim Procedure

If any Product purchased from Clearfield is found defective under the above warranty, the following basic procedure must be followed:

1.  Customer must contact Clearfield and obtain a Return Materials Authorization

2.  Following authorization, the Customer ships the product-freight collect-to Clearfield’s manufacturing facility

3.  Clearfield shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus

-

tomer’s site, freight prepaid

Note: If the Product is not found to be defective at Clearfield, the product will be returned to the Customer and the customer billed for freight in both 

directions.

View our warranty policy here: 

https://www.seeclearfield.com/warranty.html

Limitations of Warranty

Correction of defects by repair or replacement, at the option of Clearfield Inc, shall constitute the exclusive sole remedy for a breach of this limited 

warranty. Clearfield shall not be liable under any circumstances for any special, consequential, incidental, punitive, or exemplary damages arising 

out of or in any way connected with the product or with agreement to sell product to buyer, including, but not limited to damages for lost profits, loss 

of use, or for any damages or sums paid by buyer to third parties. The foregoing limitation of liability shall apply whether the claim is based upon 

principles of contract, warranty, negligence or other tort, breach of statutory duty, principles of indemnity or contribution, the failure of any limited or 

exclusive remedy to achieve its essential purpose, or otherwise.

Clearfield will not be responsible for any labor or materials costs associated with installation or incorporation of Clearfield products at customer sites, 

including any costs of alteration, replacement or defective product, or any field repairs.

Other Limitations

Clearfield assumes no warranty liability regarding defects caused by:

1.  Customer’s modification of Product, excepting installation activities described in Clearfield documentation

2.  Customer re-packaging of Product for shipment to third parties or destinations other than those originally shipped to by Clearfield, or any de

-

fects suffered during shipping where the Product has been re-packaged

3.  Customer’s installation or maintenance, excepting activities described in and performed in accordance with Clearfield documentation

4.  Customer’s improper or negligent use or application of Product

5.  Other causes external to the Product, including but not limited to accidents, catastrophe, acts of God, government action, war, riot, strikes, civil 

commotion, sovereign conduct, or the acts or conduct of any person or persons not party to or associated with Clearfield

6.  Environmental factors and weathering resulting in aging and damage not necessary or applicable to the function of the product

 


background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net 

18

Clearview Black Cassette

Installation Manual 

 _________________________________________________________

Manual 019390 Rev A - Dec 2017

Proprietary Notice

Information contained in this document is copyrighted by Clearfield, Inc. and may not be duplicated in full or part by any person without prior written 

approval of Clearfield, Inc.

Its purpose is to provide the user with adequately detailed documentation to efficiently install the equipment supplied. Every effort has been made to 

keep the information contained in this document current and accurate as of the date of publication or revision. 

However, no guarantee is given or implied that the document is error free or that it is accurate with regard to any specification.

Technical Support

Clearfield, Inc. can be contacted for any issues that arise with the supplied product.

If you need to return the supplied product, you must contact the Clearfield, Inc. Customer Service Department to request a Returned Materials 

Authorization (RMA) number.

Clearfield, Inc.

7050 Winnetka Ave N

Minneapolis, MN 55428

Toll Free:  

800.422.2537

Phone:    

763.476.6866

Fax:  

 

763.475.8457

Customer Support: sales@clfd.net