background image

 

 

 

 

 

 

 

 

 

2-inch Network Speed Dome Installation Manual  

 

 

 

 

 

 

 

 

 

 

 

 

 

Version 1.0.1 

 

 


background image

 

 

Table of Contents 

1

 

INTELLIGENT SPEED DOME INSTALLATION

 .................................................. 1

 

1.1

 

Installation Environments

 ..................................................................................................................... 1

 

1.2

 

Check installation space and installation location intension

 ........................................................... 1

 

1.3

 

Please keep all package material well for future use

 ....................................................................... 1

 

2

 

SETUP BEFORE INSTALLATION

 ...................................................................... 2

 

2.1

 

Check Accessories

 ................................................................................................................................ 2

 

2.2

 

Open Device

 ........................................................................................................................................... 2

 

2.3

 

Installation Position Map

 ....................................................................................................................... 2

 

2.4

 

SD Card Slot and Button

 ...................................................................................................................... 3

 

3

 

CAMERA INSTALLATION

 .................................................................................. 4

 

3.1

 

Component Installation

 ......................................................................................................................... 4

 

3.2

 

Installation Steps

 ................................................................................................................................... 5

 

3.2.1

 

Installation Environments

 ................................................................................................................. 5

 

3.2.2

 

Installation Steps

 ............................................................................................................................... 5

 

4

 

APPENDIX 

 LIGHTENING PROTECTION AND SURGE PROTECTION

 .......... 6

 

 


background image

 

 

ii 

5

 

APPENDIX 

12V DC WIRE GAUGE AND TRANSMISSION DISTANCE 

RELATIONSHIP SHEET

 ............................................................................................ 7

 

6

 

APPENDIX 

 WIRE GAUGE REFERENCE SHEET

 .......................................... 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

 

iii 

Welcome 

Thank you for purchasing our speed dome! 

Please read the following safeguards and warnings carefully before you install or use the 

product! 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

 

iv 

Important Safeguards and Warnings  

Safety Measures  

1. Qualified Engineer Needed  

 

The installation engineer or maintenance engineer shall have corresponding CCTV system 

installation certificate or maintenance qualification certificate.  

 

The installation engineer or maintenance engineer shall have qualification certificate for work 

at height.  

 

The installation engineer or maintenance engineer shall have the basic knowledge and 

operation technique for low-voltage cable layout and low-voltage electronic cable connection. 

 

Please read the installation manual carefully and keep it well for future reference, 

 

We are not liable for any problems caused by unauthorized modifications or attempted repair.

 

 

2. Lifting Appliance Requirement  

 

Please select the proper speed dome installation mode and use the lifting appliances at the 

safety environment. 

 

The lifting appliances shall have the enough capacity to reach the installation height. 

 

The lifting appliances shall have safe performance.  

 

 

The precaution measures include two types: Warning and Note. 

 

Warning

: It is to alert you there is an optional risk of death or series injury! 

 

Note

: It is to alert you there is an optional risk of damage or property loss! 

 

Warning 

1.  All installation and operation here should conform to your local electrical safety codes. We 

assume no liability or responsibility for all the fires or electrical shock caused by improper 

handling or installation.  

2.  Be sure to use all the accessories (such as power adapter) recommended by manufacturer. 

3.  Do not connect several speed domes to one power adapter. It may result in overheat or fire 

if it exceeds the rated load.  

4.  Avoid aiming the lens at the strong radiation source directly (such as sun, laser, molten steel 

etc); in case it may cause unrecoverable damage to the thermal imaging detector. What’s 

worse, it may cause severe damage to the detector.  

5.  Avoid oil stain and kinds of chemicals tarnishing and damaging the lens surface. 

6.  Store the device in a cool and dry place where there is ventilation but no intense 

 


background image

 

 

electromagnetic field. 

7.  Violent vibration or crash is not allowed during transportation and application.  

8.  Before you connect the cable, install or uninstall, or begin the daily maintenance work, 

please turn off the power and unplug the power cable.  

9.  Please make sure the produce is secure firmly on the wall or the ceiling.  

10.  Please turn off the power and unplug the power cable, If there is any smoke, disgusting 

smell, or noise. Please contact your local retailer or customer service centre for help.  

11.  All the examination and repair work should be done by the qualified service engineers.  We 

are not liable for any problems caused by unauthorized modifications or attempted repair. 

 

Note 

1. 

Safety Transportation  

 

Heavy stress, violent vibration or water splash are not allowed during transportation, storage 

and installation. 

 

This series product must use split type package during the transportation.  

 

We are not liable for any damage or problem resulting from the integrated package during 

the transportation. 

 

2. When device is malfunction  

Shut down the device and disconnect the power cable immediately if there is smoke, abnormal 

smell or abnormal function. Please contact your local retailer ASAP. 

 

3. Do not try to dismantle or modify the device 

 

There is risk of personal injury or device damage resulting from opening the shell. 

 

Please contact your local retailer if there is internal setup or maintenance requirement. 

 

We are not liable for any problems caused by unauthorized modifications or attempted repair.

 

 

4. Do not allow other object falling into the device  

 

Please make sure there is no metal or inflammable, explosive substance in the speed dome. 

 

The above mentioned objects in the device may result in fire, short-circuit or damage.  

 

Please shut down the device and disconnect the power cable if there is water or liquid falling 

into the camera. Please contact your local retailer ASAP. 

 

Please pay attention to the camera. Avoid the sea water or rain to erode the camera. 

 

 

5. Handle carefully  

Do not allow this series product fall down to the ground.  

Avoid heavy vibration. 

 

 

6. Installation Environment Requirement 

 

This series speed dome should be installed in a cool, dry place away from direct sunlight, 

inflammable, explosive substances and etc. 

 


background image

 

 

vi 

 

This series product shall be away from the strong electromagnetism radiant, please keep it 

away from wireless power, TV transmitter, transformer and etc. 

 

 

7. Daily Maintenance  

 

Please use the soft cloth to clean dust on the shell, or you can use soft cloth with cleaning 

liquid to clean the shell and then use soft cloth to make it dry. 

 

Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result 

in shell transfiguration or paint flake. 

 

Do not allow the plastic or rubber material to touch the shell for a long time. It may result in 

paint flake. 

 

 
 

 


background image

 

 

1

 

INTELLIGENT SPEED DOME INSTALLATION 

1.1

 

Installation Environments 

Basic Requirement  

 

All installation and operation here should conform to your local electrical safety codes.  

 

Before installation, please open the package and check all the components are included. 

Please make sure the speed dome installation environment and installation mode can meet 

your requirement. If there is special requirement, please contact your local retailer for more 

information.  

 

We assume no liability or responsibility for all the fires or electrical shock caused by 

improper handling or installation. 

 

 

1.2

 

Check installation space and installation location intension 

Please make sure the installation environment has enough space to install the speed dome and 

its corresponding bracket.  

Please make sure the ceiling, wall and the bracket can support the speed dome and its 

corresponding installation component. It shall sustain the 8X weight of the speed dome. 

 

 

1.3

 

Please keep all package material well for future use 

Please keep speed dome package material well in case you need to send it back to your local 

retailer or manufacturer for maintenance work.  

Non-original package material may result in device damage during the transportation. 

 

 

 


background image

 

 

2

 

SETUP BEFORE INSTALLATION  

2.1

 

Check Accessories  

Before the installation, please check the accessories one by one according to the packing list. 

Please make sure all the components listed are included. (Please check the container list for 

details.) 

 

2.2

 

Open Device   

Remove the package and then take out the device. See Figure 2-1. 

 

Figure 2-1 

2.3

 

Installation Position Map  

The installation position map is used for drilling positioning on the ceiling and outlet position. See 

Figure 2-2. 

 

Figure 2-2 

 


background image

 

 

2.4

 

SD Card Slot and Rest Button  

SD card slot and button is shown in Figure 2-3.  

Please make sure the SD card is in the non read-write state when removing it. Otherwise, it may 

result in data loss and SD card damage. The button is used for default setting. Long press Reset 

button for more than 5 seconds, the system configuration information will be recovered to default 

setting. 

 

Figure 2-3 

 


background image

 

 

3

 

CAMERA INSTALLATION  

2-inch network speed dome mainly adopts ceiling mount mode, which can be installed on the 

ceiling or wall.  

3.1

 

Component Installation  

The installation of pedestal seal ring is shown in Figure 3-1.  

 

Figure 3-1 

 

The ceiling mount speed dome is shown in Figure 3-2. 

 

Figure 3-2 

 

 


background image

 

 

3.2

 

Installation Steps 

3.2.1  Installation Environments   

The ceiling mount speed dome can be installed in the hard construction ceiling in the indoor 

environment. Before the installation, please make sure: 

 

The ceiling is thick enough to install the expansion bolt.  

 

The ceiling can at least sustain the 8x weight of the speed dome. 

 

3.2.2  Installation Steps  

Note: 

There are two outlet modes for ceiling mount installation.  

Don’t drill hole on the ceiling, and open wire outlet from the side of the speed dome. 

Drill hole on the ceiling, and concealed wire outlet from the ceiling.  

 

Step 1  

Install the default pedestal seal ring on the pedestal according to the way shown in Figure 3-1.  

Step 2  

Confirm installation position and outlet mode first, dig holes on the ceiling according to the 

installation position map, and then put the three plastic expansion bolts into the holes you just 

dug.  

Step 3  

Unscrew three locking screws on the enclosure by using inner hex wrench, and remove the 

enclosure.  

Step 4 

Lay the outgoing line according to the outlet mode, and use three self-tapping screws to fix the 

pedestal on the installation surface, and insert the screws into the expansion bolts.  

Step 5  

Use three locking screws to fix the dome enclosure on the pedestal.  

So far, the camera installation is completed, and you can adjust the lens angle, zoom, focus and 

etc on the WEB interface.  

 


background image

 

 

4

 

APPENDIX Ⅰ

 LIGHTENING PROTECTION AND SURGE 

PROTECTION 

This series speed dome adopts TVS lighting protection technology. It can effectively prevent 

damages from various pulse signals below 2000W, such as sudden lighting and surge. While 

maintaining your local electrical safety code, you still need to take necessary precaution 

measures when installing the speed dome in the outdoor environment. 

 

 

The distance between the signal transmission cable and high-voltage device (or high-voltage 

cable) shall be at least 50 meters. 

 

Outdoor cable layout shall go under the penthouse if possible. 

 

For vast land, please use sealing  steel tube under the land to implement cable layout and 

connects one point to the earth. Open floor cable layout is forbidden.   

 

In area of strong thunderstorm hit or near high sensitive voltage (such as near high-voltage 

transformer substation), you need to install additional high-power thunder protection device 

or lightning rod. 

 

The thunder protection and earth of the outdoor device and cable shall be considered in the 

building whole thunder protection and conform to your local national or industry standard. 

 

System shall adopt equal-potential wiring. The earth device shall meet anti-jamming and at 

the same time conforms to your local electrical safety code. The earth device shall not short 

circuit to N (neutral) line of high voltage power grid or mixed with other wires. When connect 

the system to the earth alone, the earth resistance shall not be more than 4

Ω

 

and earth 

cable cross-sectional area shall below 25 mm2.

 

 
 

 


background image

 

 

5

 

  APPENDIX 

12V DC WIRE GAUGE AND TRANSMISSION 

DISTANCE RELATIONSHIP SHEET 

The recommended max transmission distance is under the following environments: The wire 

diameter is fixed and the DC 12V power voltage loss rate is below 10%. For the device of DC 

power supplying, the max allowed voltage loss rate is 10%. All the wires listed in the following 

sheet are copper wire. (Copper wire resistance

 

   mm 

Feet

m

 

w        

0.8000 

1.000 

1.250 

2.000 

122.13

37.23

 

190.83

58.16

  298.17

90.88

 

763.31

232.66

 

10 

61.06

18.61

 

95.41

29.08

 

149.08

45.44

 

381.66

116.33

 

15 

40.71

12.41

 

63.61

19.39

 

99.39

30.29

 

254.44

77.55

 

20 

30.53

9.31

 

47.71

14.54

 

74.54

22.72

 

190.83

58.16

 

25 

24.43

7.45

 

38.17

11.63

 

59.63

18.18

 

152.66

46.53

 

30 

20.35

6.20

 

31.80

9.69

 

49.69

15.15

 

127.22

38.78

 

35 

17.45

5.32

 

27.26

8.31

 

42.60

12.98

 

109.04

33.24

 

40 

15.27

4.65

 

23.85

7.27

 

37.27

11.36

 

95.41

29.08

 

45 

13.57

4.14

 

21.20

6.46

 

33.13

10.10

 

84.81

28.85

 

50 

12.21

3.72

 

19.08

5.82

 

29.82

9.09

 

76.33

23.27

 

55 

11.10

3.38

 

17.35

5.29

 

27.11

8.26

 

69.39

21.15

 

60 

10.18

3.10

 

15.90

4.85

 

24.85

7.57

 

63.61

19.39

 

65 

9.39

2.86

 

14.68

4.47

 

22.94

6.99

 

58.72

17.90

 

70 

8.72

2.66

 

13.63

4.15

 

21.30

6.49

 

54.52

16.62

 

75 

8.14

2.48

 

12.72

3.88

 

19.88

6.06

 

50.89

15.51

 

80 

7.63

2.33

 

11.93

3.64

 

18.64

5.68

 

47.71

14.54

 

85 

7.18

2.19

 

11.23

3.42

 

17.54

5.35

 

44.90

13.69

 

90 

6.78

2.07

 

10.60

3.23

 

16.56

5.05

 

42.41

12.93

 

95 

6.43

1.96

 

10.04

3.06

 

15.69

4.78

 

40.17

12.25

 

100 

6.11

1.86

 

9.54

2.91

 

14.91

4.54

 

38.17

11.63

 

 

 

 


background image

 

 

6

 

APPENDIX 

 WIRE GAUGE REFERENCE SHEET  

 

Metric bare wire 

diameter 

mm

 

AWG 

SWG 

Bare wire cross 

section 

mm

2

 

0.050 

43 

47 

0.00196 

0.060 

42 

46 

0.00283 

0.070 

41 

45 

0.00385 

0.080 

40 

44 

0.00503 

0.090 

39 

43 

0.00636 

0.100 

38 

42 

0.00785 

0.110 

37 

41 

0.00950 

0.130 

36 

39 

0.01327 

0.140 

35 

0.01539 

0.160 

34 

37 

0.02011 

0.180 

33 

0.02545 

0.200 

32 

35 

0.03142 

0.230 

31 

0.04115 

0.250 

30 

33 

0.04909 

0.290 

29 

31 

0.06605 

0.330 

28 

30 

0.08553 

0.350 

27 

29 

0.09621 

0.400 

26 

28 

0.1257 

0.450 

25 

0.1602 

0.560 

24 

24 

0.2463 

0.600 

23 

23 

0.2827 

0.710 

22 

22 

0.3958 

0.750 

21 

0.4417 

0.800 

20 

21 

0.5027 

0.900 

19 

20 

0.6362 

1.000 

18 

19 

0.7854 

1.250 

16 

18 

1.2266 

1.500 

15 

1.7663 

2.000 

12 

14 

3.1420 

2.500 

4.9080 

3.000 

7.0683 

 
 
 
 
 
 
 
 
 

 


background image

 

 

 

Note 

 

This manual is for reference only. Slight  difference may be found in the user 

interface. 

 

All the designs and  software  here are subject to change without prior written 

notice.  

 

All trademarks and registered trademarks are the properties  of their respective 

owners.  

 

If there is any uncertainty or controversy, please refer to the final explanation of us. 

 

Please visit our website or contact your local service engineer for more 

information.