WRE2710-S Operator’s Manual and Installation Guide: 

M2M –Machine to Machine 

 

 

 


background image

 

MAN-5446-001 Rev 7 

 

Contents 

Overview ...........................................................................................................................................2 

Parts List ............................................................................................................................................3 

Installation Guide ...............................................................................................................................3 

Installation with an SMA Device- Fixed Location ...................................................................................4 

Installation with an MMCX Device- Fixed Location ................................................................................5 

Installation with an SMA Device- Mobile Location ................................................................................7 

LED Diagnostics ..................................................................................................................................8 

Diagnostic LED definitions ...................................................................................................................9 

Optional Accessories...........................................................................................................................9 

Passive Bypass Technology – Patent Pending........................................................................................9 

WRE2710 Specifications .................................................................................................................... 10 

Safeguard Features ........................................................................................................................... 11 

Antennas ......................................................................................................................................... 11 

Warranty Information ....................................................................................................................... 11 

 

Overview 

The WRE2710  Wireless Network Range Extender is a high performance, microprocessor controlled, 
bidirectional RF amplifier for the entire North American 850 MHz cellular and 1900  MHz PCS frequency 
bands. The amplifier has an automatic gain and oscillation control system that will automatically adjust 
the gain and the output power if a signal anomaly occurs. This amplifier is designed to operate as a 
direct connect unit within a cellular system, for maximum performance in weak signal coverage areas. 
The input power requirements for the amplifier are positive 8.0 to 32.0 volts DC (negative ground).  

 

 

 


background image

 

MAN-5446-001 Rev 7 

 

Parts List  

Depending upon the connector type of the cellular device, ClearRF can customize the M2M kit to include 
the appropriate adapters to ensure a seamless and quick installation.  Adapter types include, but are not 
limited to SMA, RP-SMA, MMCX, MCX, FME, and TNC.   

1.

 

WRE2710  Amplifier Unit 
 

 

2.

 

AC/DC Power Adapter 

 

3.

 

Hardwire DC Power Cable 

 

4.

 

Magnetic-Mount Outdoor Signal 
Antenna 

 

5.

 

SMA-to-SMA Device Cable –If connecting to 
an  SMA device  

 

6.

 

Optional –SMA-to-MMCX Device Cable –
If connecting to an MMCX device. 

 

Installation Guide 

Disclaimer: Installation  of this device requires knowledge of basic electrical  and 
experience with installing electronic devices. We recommend seeking a 
professional installer if  you are not accustomed to installing  electronics or high 
tech devices. Installation  of this device is at your own risk. ClearRF, LLC 
assumes no responsibility for the installation  or improper operation of this 
device. Contact your dealer or 

CustomerService@ClearRF.com

 

with “Installation 

Help” in the subject line for assistance. 

 


background image

 

MAN-5446-001 Rev 7 

 

 

Installation with an SMA Device- Fixed Location 

1.

 

If connecting to a Cellular Modem (e.g. Raven X, CradlePoint), connect the SMA to SMA device cable 
(#5 on Parts List) to the ClearRF Amplifier connector marked “Device”. 

 

 
 
 
 
 

2.

 

Connect the SMA end of the SMA to SMA device cable to the Cellular Modem antenna 
connection. 

 

 

 


background image

 

MAN-5446-001 Rev 7 

 

3.

 

Mount the Outdoor Signal Antenna (#4 on Parts List) vertically on any metal surface. 

 

a.

 

Connect the Outdoor Signal Antenna connector to the ClearRF amplifier SMA connector 
marked “Antenna”. 

 

4.

 

Plug the AC Adapter (#2 on Parts List) into a nearby wall outlet. 

5.

 

Insert the AC Adapter connector plug into the amplifier and watch the LED indicators.  

 

 

 

Installation with an MMCX Device- Fixed Location 

1.

 

If connecting to a Cellular Module (e.g. Motorola, Sierra Wireless), connect the SMA-to-MMCX 
device cable (#6 on Parts List) to the ClearRF Amplifier connector marked “Device.” 

 

 


background image

 

MAN-5446-001 Rev 7 

 

2.

 

Connect the MMCX end of the SMA to MMCX device cable to the Cellular Module. 

 

 

3.

 

Mount the Outdoor Signal Antenna (#4 on Parts List) vertically on any metal surface. 

 

4.

 

Connect the Outdoor Signal Antenna connector to the ClearRF amplifier SMA connector marked 
“Antenna”. 

 

5.

 

Plug the AC Adapter (#2 on Parts List) into a nearby wall outlet. 

 

6.

 

Insert the AC Adapter connector plug into the amplifier and watch the LED indicators.  

 

 

 


background image

 

MAN-5446-001 Rev 7 

 

Installation with an SMA Device- Mobile Location 

1.

 

If connecting to a Cellular Modem or Mobile Data Terminal (e.g. Raven X, etc) in a vehicle or 
mobile application, connect the SMA to SMA device cable (#5 on Parts List) to the ClearRF 
Amplifier connector marked “Device”. 

 

 
 

2.

 

Connect the SMA end of the SMA-to-SMA device cable to the Cellular Modem or MDT antenna 
connection. 

 

 

 
 
 

3.

 

Mount the Outdoor Signal Antenna (#4 on Parts List) vertically on any metal surface on the roof, 
hood or trunk of the vehicle. 

 

 

 


background image

 

MAN-5446-001 Rev 7 

 

4. 

Connect the Outdoor Signal Antenna connector to the ClearRF amplifier SMA connector marked 
“Antenna”. 

 

5. 

Plug the 12V Hardwire DC Cable (#3 on Parts List) into the vehicle fuse block. You must connect 
the red wire to a positive terminal from the fuse panel with a 3 ampere fuse rating. The black 
wire should be attached to a ground of the vehicle.  Power may also be provided to the amplifier 
using a 12V cigarette lighter adaptor.  (not included, available at www.clearrf.com) 

 

6. 

Insert the Hard Wire DC Cable connector plug into the amplifier and watch the LED indicators.  

 

 
 

LED Diagnostics 

Once the amplifier is installed properly and power is applied, the LEDs will both turn on followed by 
the green LED flashing. The green LED will flash while the amplifier increases its gain to the optimum 
level. The red LED may also flash during this stage while the gain (power) is properly set on the 
amplifier. When power control is established, the green LED will remain constantly on. You may see 
the green and red LEDs flash back and forth, THIS IS NORMAL. In areas where the cellular network is 
adequate, the amplifier will maintain a maximum power level acceptable for normal operati on and 
prevent overloading the wireless phone, as well as keeping RF signal levels at a minimum for a 
healthy environment. 

If the red LED is constantly on and the green LED is off, the amplifier has 

detected a fault.

 The amplifier will shut down automatically and restart. If the fault persists, 

reposition the antenna until normal operation is achieved. - Once normal operation is established, 
you may permanently mount the antennas in the locations you chose in the prior steps.  

 


background image

 

MAN-5446-001 Rev 7 

 

Diagnostic LED definitions 

1.

 

Solid Green and Red – LED test, the unit is initializing 

2.

 

Solid Green – Normal operation 

3.

 

Flashing Green – Normal operation, increasing gain setting 

4.

 

Solid Green and Flashing Red – Normal operation, decreasing gain setting 

5.

 

Solid Red and no Green – Fault detected (Unit will shut down until power is cycled.) 

Optional Accessories 

Contact us at www.clearrf.com for pricing and availability or see your Clear RF™ dealer. Replacement 
parts and additional accessories may also be available. 

Passive Bypass Technology – Patent Pending 

The WRE2710  amplifier is equipped with ClearRF’s Passive Bypass technology. This feature allows the 
amplifier to passively bypass itself and become merely a pass through cable when amplification is not 
necessary, during loss of power or when a fault is detected. 

Passive Bypass technology is useful in applications where the amplifier is mobile, moving in and out of 
poor signal areas. The amplifier will bypass itself when close to cell towers, completely eliminating any 
potential for network disrupting noise power caused by too much amplification near a cell tower. The 
technology is also extremely useful in fire and security system installations where a connection with the 
antenna must always be maintained, even with loss of power. 

 

 


background image

 

MAN-5446-001 Rev 7 

 

10 

 

WRE2710 Specifications 

 

Frequency Range: Cellular 850 (824MHz  – 894MHz), PCS 1900  (1850MHz  – 1990MHz) 

 

20dB BW: 850  UL: 39MHz, 1900  UL: 115MHz 

 

Rated Uplink Maximum Output Power: Cellular 850; 27dBm, PCS 1900;  27dBm 

 

Rated Downlink Maximum Output Power: Cellular 850; -20dBm, PCS 1900;  -20dBm 

 

Current Draw @ 12VDC: Idle: 250 milliamperes; Max: 1 amperes 

 

Power Requirement: 8.0 to 36.0 volts DC (negative ground), Connector is center positive 

 

Nominal Gain: Cellular 850: 15dB, PCS 1900:  15dB  

 

Input/output Impedance: 50 Ohms 

 

Rated Mean Output Power: 27dBm 

 
FCC ID: XS7-WRE2710 
IC ID: 8918A-WRE2710 
This device complies  with Part 15 of the FCC Rules.   Operation is subject to the following  two conditions:  (1 ) this 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause  undesired operation. 

The term “IC:” before the radio certification number only signifies  that Industry of Canada  technical 
specifications  were met. The Manufacturer's  rated output power of this equipment is for single carrier 
operation. For situations  when multiple carrier signals  are present, the rating would have to be reduced by 3.5 
dB, especially  where the output signal  is re-radiated and can cause  interference to adjacent  band users. This 
power reduction is to be by means of input power or gain  reduction and not by an attenuator at the output of 

the device. 

La puissance  de sortie nominale  indiquée par le fabricant  pour cet appareil concerne son fonctionnement avec 
porteuse unique. Pour des appareils  avec porteuses multiples, on doit réduire la valeur nominale de 3,5 dB, 
surtout si le signal  de sortie est retransmis et qu'il peut causer du brouillage aux utilisateurs de bandes 
adjacentes.  Une telle réduction doit porter sur la puissance  d'entrée ou sur le gain, et ne doit pas se faire au 

moyen d'un atténuateur raccordé à la sortie du dispositif. 

FCC Regulatory  Guidance:  ClearRF’s WRE2710-S operates under the rules and regulations as provided by the 
Federal Communications  Commission (FCC).  For more information on these rules and regulations,  please 
contact the FCC directly at (888)-225-5322.  
 

 


background image

 

MAN-5446-001 Rev 7 

 

11 

 

Safeguard Features 

 

The amplifier has an automatic gain and oscillation control system that will automatically adjust 

the gain and the output power if a signal anomaly occurs. This amplifier is designed to operate as a 
tethered (direct connect) unit within a cellular system, for maximum performance in weak signal 
coverage areas.  

Antennas 

 

You MUST operate this device with approved antennas and cables as specified by the 

manufacturer.  Antennas MUST be installed as least 20 cm (8 inches) from any person. 

 

Included Antenna:  MSE-5721-001 Mag Mount Antenna  

 

Included Cable: CBL-SMA-SMA or CBL-SMA-MMCX 

Warranty Information 

Lim ited Warranty 

ClearRF  L.L.C. w arrants that this product is free from defects in materials or w orkmanship for one year from the date of purc hase. 
Within this period, ClearRF, w ill, at its sole option, repair or replace any components w hich fail in normal use. Such repairs or 
replacement w ill be made at no charge to the customer for parts or labor, provided that the customer shall be responsible for  any 
transportation cost. This w arranty does not cover failures due to abuse, misuse, accident or unauthorized alterations or repairs. 

Repairs have a 90 day w arranty. If the unit sent in is still under its original w arranty, then the new  w arranty is 90 days or  to the end 
of the original one year w arranty, depending upon w hich is longer. 

ClearRF  retains the exclusive right to repair or replace the product or offer a full refund of the purchase price at its sole discretion. 
Such remedy shall be your sole and exclusive remedy for any breach of w arranty.  ClearRF shall not be liable for any incident al or 
consequential damages for breach. 

 


background image

 

MAN-5446-001 Rev 7 

 

12 

 

Procedure  for Claims  under Limited  Warranties 

To  obtain  warranty  service,  an original  or  copy of the  sales receipt  from  the original  retailer  is required. 
To  obtain  warranty  service,  follow  these two steps: 

1.  Contact  ClearRF  via  email to receive  authorization  (RMA)  number  at warranty@clearrf.com 
2.  Once  you have  obtained  an  RMA #, ship the unit, copy of  the sales receipt,  along  with the  RMA 

number  to: 

 

ClearRF 
RMA #: {insert  RMA number} 
12825  E. Mirabeau  Parkway,  Suite 104 
Spokane  Valley, WA 99216 
855-321-9527