PDF User Manual

  1. Home
  2. Manuals
  3. ClearOne DigiLinX NS-IPD-100 Installation Manual

ClearOne DigiLinX NS-IPD-100 Installation Manual

Made by: ClearOne
Type: Installation Manual
Category: Docking Station
Pages: 12
Size: 1.75 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

InstallatIon Manual

DigilinX™ ns-IPD-100

iPod

®

 Docking station

 


background image

Clearone
5225 Wiley Post Way
suite 500
salt lake City, ut 84116
telephone

  

 

1.866.353.3496

FaX

 

 

 

1.512.977.9398

E-mail

   

 

Support@NetStreams.com

on the Web

 

 

www.NetStreams.com

DigilinX ns-IPD-100 iPod Docking station Installation Manual

Clearone Document no. 800-000-045 Rev. 1.1 - March 7, 2011

©  2011  ClearOne  and  NetStreams.  All  rights  reserved.  No  part  of  this 
document may be reproduced in any form or by any means without written 
permission from ClearOne and NetStreams.
ClearOne and NetStreams reserves specific privileges. Information in this 
document is subject to change without notice.

u.s. PatEnts:
otHER PatEnts PEnDInG.
this software is based in part on the work of the Independent 
JPEG Group.

 


background image

CHaPtER 1: IntRoDuCtIon .............................................................................. 1

Product Overview ..................................................................................................1
Service and Support ..............................................................................................1
Technical Support ..................................................................................................1
Sales and Customer Service .................................................................................1
Product Returns .....................................................................................................1
Package Contents .................................................................................................1

CHaPtER 2: BasIC systEM ConnECtIons .................................................... 2

CHaPtER 3: DEalER sEtuP anD ConFIGuRatIon ....................................... 3

Screen Overview ...................................................................................................3
Setup .....................................................................................................................4

CHaPtER 4: tECHnICal sPECIFICatIons ...................................................... 9

Specifications ........................................................................................................9
Wired LAN Interface ..............................................................................................9
Audio ......................................................................................................................9
Dimensions ............................................................................................................9
Weight ....................................................................................................................9
Power .....................................................................................................................9
Environmental ........................................................................................................9
Warranty ................................................................................................................9
Product Compatibility List .....................................................................................9
iPod Control ...........................................................................................................9
Agency Certification ..............................................................................................9
Model Number .......................................................................................................9

T

able

 

of

 C

onTenTs

 


background image

1     technical support: 

800-283-5936

CHaPtER 1: IntRoDuCtIon

PRoDuCt ovERvIEW

The NS-IPD-100 connects to a DigiLinX system and becomes an integral part of the multi-room audio system. 
It charges the iPod battery and provides control of iPod playback from the DigiLinX system.
The sleek NS-IPD-100 is the DigiLinX interface to Apple

®

 iPod media players. Once an iPod is placed in the 

NS-IPD-100, the music library on the iPod can be quickly and easy be searched by genre, playlist, album, artist 
or individual song title from any location in the home with a DigiLinX controller, including in-wall touchscreens 
or wireless remotes.
The NS-IPD-100 can be placed anywhere convenient such as a counter, desktop or shelf. The dock connects 
exclusively  to  a  NetStreams  AP500  or  EIM2RCA  within  a  DigiLinX  multi-room  AV  system  with  an  audio 
connection directly to a SpeakerLinX SL251 or TouchLinX TLA250 local input port and is controlled via the 
DigiLinX Ethernet network.
The NS-IPD-100 is perfect for those who wish to enjoy their iPod music library on their DigiLinX multi-room AV 
system.

sERvICE anD suPPoRt

If you need assistance setting up or operating your NS-IPD-100 iPod Docking Station, please contact us. We 
welcome your comments so we can continue to improve our products and better meet your needs.

technical support

Telephone: 

1.866.353.3496 or 1.800.283.5936

Fax: 

 

1.512.977.9398

E-mail:   

Support@NetStreams.com

Web site: 

www.NetStreams.com

sales and Customer service

Telephone: 

1.800.705.2103

Fax: 

 

1.512.977.9398

E-mail:   

Sales@NetStreams.com

Product Returns

All  product  returns  require  a  Return  Material  Authorization  (RMA)  number.  Contact  NetStreams  Technical 
Support before returning your product. Make sure you return all the items and packing materials that originally 
shipped with your product.

PaCkaGE ContEnts

The illustration below shows the parts that ship in the box with the NS-IPD-100 iPod Docking Station.
Contact your dealer for replacement parts and accessories.

>  notE: netstreams is not responsible for product damage incurred during shipment. you must 

make  claims  directly  with  the  carrier.  Inspect  your  shipment  carefully  for  obvious  signs  of 
damage. If the shipment appears damaged, retain the original boxes and packing material for 
inspection by the carrier. Contact your carrier immediately.

 


background image

Chapter 2: Basic System Connections

     2

CHaPtER 2: BasIC systEM ConnECtIons

Use the diagram below to configure a basic system integration.

>  notE: Cat5e cable run between the netstreams aP500 and the EIM Port on the host device 

(netstreams tla250 in above diagram) should not exceed 60’ in length.
Cat5e  cable  runs  back  to  the  switch  (netstreams  sW1124  in  above  diagram)  should  not 
exceed 300’ in length due to 10/100Based-t lan limitations.

the distance between the ns-IPD-100 Docking station and the netstreams aP500 should not 
exceed 20’.

the synch button is active but the video and IR Ports are not active on the ns-IPD-100.

the devices in the above diagram are for reference only and are not included with the ns-
IPD-100 unit.

 


background image

3     technical support: 

800-283-5936

CHaPtER 3: DEalER sEtuP anD ConFIGuRatIon

sCREEn ovERvIEW

The components of the Dealer Setup screen are outlined below.

 


background image

Chapter 3: Dealer Setup and Configuration

     4

sEtuP

Use the following steps to configure an IP Address and the optional DHCP Server.

Launch the Dealer Setup application. The Dealer Setup application will search and identify each IPD100 

1. 

device currently on the NetStreams network. A list of found devices will appear in the Device Panel of the 
Dealer Setup screen.

>  notE: If setting up via the optional DHCP method, verify that the IP settings of the IPD100 and 

the device it is paired with (touchlinX tla250 as shown in the Basic Connections diagram 
above or the speakerlinX sl251) are consistent. units must be on the same IP subnet.

Select the device that provides the user interface to the Docking Station (TLA250 in the Basic Connection 

2. 

diagram) from the selection on the screen’s Project Panel then click the “

show  advanced  options

” 

button on the Device Panel.

 


background image

5     technical support: 

800-283-5936

On the Device Panel, click on the 

3. 

Enable Static IP

 and enter the IP, Subnet Mask and Gateway addresses 

of the interface device (TLA250 as shown in the Basic Connection diagram). Optionally, check the 

Enable 

DHCP

 checkbox if a DHCP server is to be used. If the DHCP is enabled and a DHCP server are not avail-

able, the TLA250 or the SL251 will revert to the Auto IP address settings in the Dealer Setup.

Click on the “

4. 

apply

” button in the lower-left of the Device Panel.

 


background image

Chapter 3: Dealer Setup and Configuration

     6

Select the 

5. 

Audio Port

 tab on the Device Panel.

Locate the 

6. 

Service Name

 field on the Device Panel. Enter the name of the IDP100. This name will appear 

on the user interface as a source or it can be left with the default name.
Click on the drop-down arrow to the right of the iPod Dock option to display a list of IPD100 devices on 

7. 

the network.

>  notE: If more than one IPD100 is integrated, it is important to know which audio Port each 

IPD100 is assigned to for correct integration. the iPod Dock naming convention begins with 
“IPD100” followed by the last six characters of the device’s MaC address found on the bottom 
of the IPD100.

Select the appropriate iPod Docking Station ID from the list.

8. 

If using a Static IP Address, enter the IP, Subnet Mask and Gateway Addresses of the IPD100, otherwise, 

9. 

proceed to Step 10.
Enable or disable the DHCP as necessary by clicking on the DHCP Enabled checkbox (DHCP is enabled 

10. 

by default). Refer to the on-screen information to further detail the setup and configuration of the IPD100.

>  notE: Refer to the netstreams user’s Manual for specific information regarding the service 

name, service type and local source fields.

Click on the “

11. 

apply

” button located in the lower-left of the Device Panel to store the changes.

 


background image

7     technical support: 

800-283-5936

Click on the “

12. 

send Configuration to Devices

” button from the Dealer Setup toolbar.

Click on the “

13. 

select all

” button from the dialog screen that appears then click on the “

ok

” button.

Once the system is done updating the new device, a dialog window will display a message stating that 

14. 

the update is complete. The device interface (TLA250 in the Basic Connection diagram) will restart. Once 
the restart  is  finished,  a  green check-mark  will  appear  showing  that  the device has  successfully  been 
configured.

 


background image

Chapter 3: Dealer Setup and Configuration

     8

Click the “

15. 

X

” button in the upper-right of the dialog window to exit this screen.

From the user interface (TLA250 in the Basic Connection diagram), set the Source to be the iPod Docking 

16. 

Station.  This  will  allow  the  end  user  to  control  the  connected  iPod,  access  its  library  of  music,  make 
selections and view the metadata (including cover art) of the selection.

 


background image

Chapter 4: Technical Specifications

     9

CHaPtER 4: tECHnICal sPECIFICatIons

sPECIFICatIons

Wired lan Interface

10BASE-T
100BASE-TX (Auto-recognition)

audio

3.5 mm Stereo
Unbalanced Line Level Audio Out 

Dimensions
(W x D x H)

4.25” x 3.50” x 1.50”
(110 mm x 90 mm x 40 mm)

Weight

6.5 oz. (185 g)

Power

Input: AC Adapter 100 - 240 VAC, 50/60 Hz
Output: 5 VDC 2A (10W Max)

Environmental

Temperature:
41 - 113° F (5 - 45° C)
Humidity: 10% - 90%
Heat Dissipation: 15 BTU

Warranty

Two (2) Years

Product Compatibility list

iPhone 1G, 3G, 3GS
iPod 3G, 4G, 5G
iPod Classic
iPod Mini 1G, 2G
iPod Nano 1G, 2G, 3G, 4G, 5G
iPod Photo
iPod Touch 1G, 2G
NetStreams SL251 and TLA250

iPod Control

Music Content Browse
Music Playback Control
Playing Track Information Retrieval
Track Artwork Retrieval
iPod Settings Control

(Shuffle, Next, Previous, Play/Pause and Stop)

agency Certification

RoHS
REACH
FCC Class B Part 15 Subpart B
VCCI Class B
CE Listed

Model number

NS-IPD-100

HEaDquaRtERs:

salt lake City, ut usa

5225 Wiley Post Way
Suite 500
Salt Lake City, UT 84116

tel:

 

801-975-7200

toll Free:

  800-945-7730

Fax:

 

801-977-0087

E-mail:

 sales@ClearOne.com

latin america

tel:

 

801-974-3621

E-mail: 

global@ClearOne.com

EMEa

tel:

 

44 (0) 1189 036 053

E-mail: 

global@ClearOne.com

aPaC

tel:

 

801-303-3388

E-mail: 

global@ClearOne.com