CONNECT AVB

Made by: ClearOne
Type: Quick Start Guide
Category: Media Converter
Pages: 16
Size: 0.87 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

CONNECT CobraNet and CONNECT AVB

Network Audio Bridge for CONVERGE PRO & SR Products

Quick-Start Guide

 


background image

THE CONNECT COBRANET AND CONNECT AVB ..........................1
QUICK-START OVERVIEW ................................................................1

Q

uick

-S

tart

 S

ummary

 ...........................................................................3

UPDATE THE CONVERGE PRO FIRMWARE ....................................3
SET THE DEVICE ID ..........................................................................4
CONNECTING THE CONNECT COBRANET/AVB UNIT  ..................5
UPDATING THE CONNECT COBRANET/AVB FIRMWARE ..............6
ADDING CONNECT NETWORK BRIDGES TO SITES ......................7

a

dding

 

the

 B

ridge

 ................................................................................7

e

diting

 

the

 cOnnect n

etwOrk

 B

ridge

 

in

 S

ite

 ....................................7

c

OBra

n

et

 S

ettingS

 ..........................................................................8

aVB S

ettingS

 ................................................................................10

UPGRADING FROM OLDER VERSIONS 
OF CONVERGE FIRMWARE ...........................................................12

u

pgrading

 

frOm

 cOnVerge p

rO

 3.X 

firmware

 .................................12

u

pgrading

 

frOm

 cOnVerge p

rO

 2.X 

firmware

 .................................13

u

pgrading

 

frOm

 cOnVerge p

rO

 1.X 

firmware

 .................................13

PART NUMBERS ..............................................................................14 
CLEARONE LOCATIONS ................................................................14

Table of Contents

 


background image

QUICK-START GUIDE

1

THE CONNECT COBRANET AND CONNECT AVB

The CONNECT CobraNet

®

 and CONNECT AVB network bridges add 

networked audio capabilities to CONVERGE PRO and CONVERGE SR 
products enabling them to transmit audio through Ethernet networks.

IMPORTANT: 

The CONNECT CobraNet and CONNECT AVB 

bridges only can be used with CONVERGE Pro/SR systems 
operating at version 4.2 or higher software and firmware.

The latest version of the CONVERGE Pro firmware can be found on the 
ClearOne website at:

http://www.clearone.com/resources#professional_audio

QUICK-START OVERVIEW

Installing and using the CONNECT CobraNet and CONNECT AVB 
bridges in your CONVERGE Pro/SR site is subject to the following rules:
1.  The CONNECT CobraNet and CONNECT AVB can only be used 

with CONVERGE Pro/SR systems operating at version 4.2.X or 
greater, and requires that the firmware on the CONVERGE Pro/SR 
be updated.

2.  You must have a CONVERGE Pro 840T, 880, 880T, 880TA, 8i, TH20, 

VH20 and/or SR1212, SR1212A in the site. 

3.  The CONNECT CobraNet and AVB bridges support only 8 Ethernet 

audio channels in and 8 Ethernet channels out.

4.  Either the CONNECT CobraNet or AVB can be used, depending on 

the particular networks architecture.

 


background image

CONNECT NETWORK BRIDGES

2

 

Ethernet LAN  

Network 1  

 

CONVERGE Pro/SR

 

CONNECT 

Network Bridge 

 

CONNECT 

Network Bridge

 

Ethernet LAN  

Network 2 

CobraNet

 

 

CONNECT 

Network Bridge

 

CONNECT 

Network Bridge

 

Connecting CONVERGE Pro/SR units in different 

rooms that are on different networks using 

multiple CobraNet

 

and AVB network bridges

 

AVB

CobraNet

AVB

AVB

CobraNet

Link IN

Link IN

Link OUT

Link IN

Link IN

AVB 

Network

Connection

AVB 

Network

Connection

CobraNet 

Network

Connection

CobraNet 

Network

Connection

CONVERGE Pro/SR

CONVERGE Pro/SR

Up to eight CONNECT units can be attached to a single CONVERGE 
Pro/SR stack with each set to a unique Device ID using the DID selector 
rotary switch

Both CobraNet and AVB networks can be audio sources to CONVERGE 
Pro/SR mixers using the appropriate types of audio network bridges. The 
following diagram shows how several CONVERGE Pro/SR stacks can 
connect over AVB and CobraNet networks.

 


background image

QUICK-START GUIDE

3

Quick Start Summary

These steps must be done in the following order to use the CONNECT 
network audio bridge in your CONVERGE Pro Site:
1.  Update the CONVERGE Pro firmware to version 4.2.X using 

CONVERGE Console.

2.  Set the Device ID of the CONNECT CobraNet and/or CONNECT 

AVB using the Device ID rotary selector switch at the back of the 
bridge.

3.  Connect the CONNECT CobraNet and/or CONNECT AVB to the 

updated CONVERGE Pro/SR via the Expansion bus (E-bus).

4.  Update the CONNECT network bridge firmware
5.  Configure the CONNECT CobraNet and CONNECT AVB with 

CONVERGE Console.

UPDATE THE CONVERGE PRO FIRMWARE

Update your CONVERGE Console to version 4.2 or higher. CONNECT 
CobraNet and CONNECT AVB network audio bridges are not recognized 
by systems running older versions and the 4.2.X versions offer significant 
upgrades from previous versions. 

ClearOne strongly encourages users to upgrade all firmware to the latest 
release version. 

Instructions for updating from version 1.X 2.X and 3X are detailed later in 
this document.

 


background image

CONNECT NETWORK BRIDGES

4

Device ID Rotary 

Selection Switch

SET THE DEVICE ID

Set each CONNECT CobraNet and CONNECT AVB unit to a unique ID 
using the Device ID selector rotary switch on the back of the unit. (Range 
0-7) Each CONNECT unit in any site needs a unique Device ID. Only 8 
units are allowed in any site.

NOTE: Save the CONVERGE Console site file before performing 
any firmware upgrade. 

1.  Download the 4.2.X firmware file to the stack of units.
2.  The units will default and reboot after the download of 4.2.X 

firmware. 

3.  Units are fully upgraded.
4.  Verify units have been upgraded by checking the firmware version 

on the front panel.

Reconnect all E-bus cables, if needed, to complete the stack of units.

 


background image

QUICK-START GUIDE

5

CONNECTING THE CONNECT COBRANET/AVB 
UNIT

Connect the CONNECT CobraNet/AVB units to the CONVERGE Pro/
SR stack via the E-bus connections using CAT5/CAT6-24AWG solid 
conductor RJ45 cables. Power to the CONNECT CobraNet/AVB is 
supplied by a standard power adapter supplied with the unit.

Device ID 

Switch

E-bus LINK IN from Stack

E-bus LINK OUT  

(Not required if the bridge 

is at the end of the stack)

Bridge connection 

to Ethernet Network 

(CobraNet shown)

5V DC 

Power  

Input

NOTE: The network connectors for the CONNECT CobraNet and 
the CONNECT AVB appear to be identical but they are not. Each is 
electronically unique to the type of network being bridged. Only use 
the CONNECT CobraNet with CobraNet networks, and CONNECT 
AVB with AVB networks.

 


background image

CONNECT NETWORK BRIDGES

6

UPDATING CONNECT COBRANET/AVB FIRMWARE

NOTE: All CONNECT CobraNet/AVB Pro units in the site must be 
running firmware level 4.X to be compatible with the CONVERGE 
Pro/SR units in the site. 

1.  Connect the E-bus cable between the CONVERGE Pro units and 

the CONNECT audio network bridge.

2.  Connect the CONVERGE Pro units with CONVERGE Console.
3.  Open the 

Firmware Loader

 screen.

4.  Browse for the CONNECT firmware file:

 cobranet.mdo

 for the 

CONNECT CobraNet, and 

avb.mdo

 for the CONNECT AVB.

5.  Download the CONNECT audio network bridge firmware.
6.  The CONNECT audio network bridge will default and reboot after 

the download of the firmware. (The version of the firmware can be 
verified later using the 

Unit Properties

 screen for the CONNECT 

network bridge.)

7.  Units are fully upgraded. (All units connected via the E-bus on the 

site are simultaneously updated.)

8.  Restore the saved site file to the system using CONVERGE 

Console.

 


background image

QUICK-START GUIDE

7

ADDING CONNECT NETWORK BRIDGES TO SITES

Each CONNECT CobraNet and/or AVB network bridge must be added 
to the site using the CONVERGE Console 4.2.X and later software. 
This software also provides the capability selecting the audio channels 
and other characteristics. Refer to the online help available with the 
CONVERGE Pro/SR software for adding devices.

Adding the Bridge

Using the CONVERGE Console software, 

ADD

 the CONNECT CobraNet 

and/or AVB network bridge to the site using the drop-down menu.

Editing the CONNECT Network Bridge in Site

Select the CONNECT CobraNet and/or AVB audio network bridge from 
the 

Site View

 tab in Console, and the device appears under the 

Site

 

button on the right-hand portion of the screen. 

Click on the device box and the Unit Properties appear for the device.

 


background image

CONNECT NETWORK BRIDGES

8

CobraNet Settings

The next two figures show the Unit Properties tabs for the CONNECT 
CobraNet bridge.

Set the Device ID (DID) to match that of the rotary selection switch of the 
CONNECT CobraNet device.

 


background image

QUICK-START GUIDE

9

RX and TX Bundle Numbers

When a receiver on one interface is assigned the same bundle number 
as that of a transmitter on another interface, the CobraNet protocol 
automatically establishes a connection for transmitting audio data 
between the interfaces.
ClearOne CobraNet is a single-bundle, eight-channel device with a 
fixed 48 kHz sample rate. The eight channels of audio correspond to 
E-bus assignments S through Z. Any audio placed on these busses will 
be transmitted in the CobraNet bundle. Any audio received from the 
CobraNet bundle can be taken off the S to Z bus on any CONVERGE Pro 
Unit.

Latency

The buffering and transmission of audio data typically incurs a delay of 
256 samples or 5 1/3 milliseconds called Bundle Latency. This delay can 
be reduced by sending smaller packets more often but comes at the cost 
of higher processing demands and greater network demands

Channel Assignment

Complete the audio channel assignments in the Matrix in CONVERGE 
Console for the channels present in the network bridge. When a CobraNet 
is added to the site any audio on the S Bus will automatically be placed on 
the CobraNet transmit bundle on Audio channel 1. 

 


background image

CONNECT NETWORK BRIDGES

10

AVB Settings

The next two figures show the Unit Properties tabs for the CONNECT AVB 
bridge.

Set the Device ID (DID) to match that of the rotary selection switch of the 
CONNECT AVB device.

 


background image

QUICK-START GUIDE

11

AVB Mode

“AVB” uses the AVB protocols for streaming of audio with AVB switches.
“Legacy” simplifies the AVB packets allowing them to pass through 
“legacy” LAN switches and routers

Reset

Used to force initialization of audio streaming after Talker and Listener and 
TX changes are made.

Talker and Listener Stream ID’s

AVB endpoints are able to pass streams between each other.  The Talker 
sends the stream and the Listener receives the stream.  On a network, 
each stream has a unique 64 bit (hex) ID.  A Talker must be assigned a 
unique ID.  For the Listener to receive the stream is must be assigned the 
same ID as the desired Talker.  The CONVERGE AVB is both a Talker and 
a Listener

Number of Audio Channels per AVB Talker

 

When the Converge AVB is a Talker it can set to use 2, 4, 6, or 8 audio 
channels.  On the E-bus connected CONVERGE Pro, the audio channels 
start with the S Bus input.

Number of Audio Channels per AVB Listener

When the Converge AVB is a Listener it can receive 2, 4, 6, or 8 audio 
channels.  On the E-bus connected CONVERGE Pro the audio channels 
start with the S Bus output.

 


background image

CONNECT NETWORK BRIDGES

12

Channel Assignment

Complete the audio channel assignments in the Matrix in CONVERGE 
Console for the channels present in the network bridge. Eight audio 
channels are supported and are assigned to E-bus channels S through Z.

UPGRADING FROM OLDER VERSIONS OF 
CONVERGE FIRMWARE

Please follow the steps listed below to upgrade your firmware:

NOTE: Save the CONVERGE Console site file before performing any firmware 
upgrade.

 

Upgrading from CONVERGE Pro 3.X firmware

1. 

Remove any 1.X, 2.X and 4.X units from the stack by disconnecting the 
expansion bus link cable from the 3.X units.

2. 

Re-connect to the 3.X stack with CONVERGE Console.

3. 

Download the 4.2.X firmware file to the stack of units.

4. 

The units will default and reboot after the download of 4.2.X firmware. 

5. 

Units are fully upgraded.

 


background image

QUICK-START GUIDE

13

6. 

Verify units have been upgraded by checking the firmware version on the 
front panel.

Reconnect all E-bus cables, if needed, to complete the stack of units.

Upgrading from CONVERGE Pro 2.X firmware

1. 

Remove any 1.X, 3.X and 4.X units from the stack by disconnecting the 
expansion bus link cable from the 2.X units.

2. 

Re-connect to the 2.X stack with CONVERGE Console.

3. 

Download the 4.X firmware file to the stack of units.

4. 

The units will default and reboot after the download of 4.X firmware. The 2.X 
to 4.X upgrade requires the firmware to be loaded twice to complete the 
version upgrade.

5. 

Units are fully upgraded.

6. 

Verify units have been upgraded by checking the firmware version on the 
front pane

l.  

Reconnect all E-bus cables, if needed, to complete the stack of units.

 

Upgrading from CONVERGE Pro 1.X firmware

1. 

Remove any 2.X, 3.X and 4.X units from the stack by disconnecting the 
expansion bus link cable from the 1.X units.

2. 

Re-connect to the 1.X stack with CONVERGE Console.

3. 

Download the 4.X firmware file to the stack of units.

4. 

The units will default and reboot after the download of 4.X firmware. The 1.X 
to 4.X upgrade requires the firmware to be loaded twice to complete the 
version upgrade.

 


background image

CONNECT NETWORK BRIDGES

14

5. 

Reconnect to the stack with CONVERGE Console.  Download 4.X a second 
time to the units.  The units will reboot.

6. 

Units are fully upgraded.

7. 

Verify units have been upgraded by checking the firmware version on the 
front panel.

Reconnect all E-bus cables, if needed, to complete the stack of units.

PART NUMBERS

910-151-805

CONNECT CobraNet Network Bridge

910-151-804

CONNECT AVB Network Bridge

CLEARONE CONTACTS

HEADQUARTERS:

Salt Lake City, UT USA

5225 Wiley Post Way
Suite 500
Salt Lake City, UT 84116

Sales:

 

800-705-2103

Toll Free:

 800.945.7730

Fax:

 

801.977.0087

e-mail:

 sales@clearone.com

TechSales

Tel:

 800.705.2103

e-mail: 

techsales@clearone.com

Technical Support

Tel:

 800.283.5936

e-mail: 

tech.support@clearone.co

EMEA:

Tel:

 

+44 (0) 1189 036 053

e-mail: 

global@clearone.co

APAC:

Tel:

 

+852 3590 4526

e-mail: 

global@clearone.com

LATAM:

Tel:

 

801-974-3621

e-mail: 

global@clearone.com

Middle East:

Tel:

 

+852 3590 4526

e-mail: 

global@clearone.com

© 2013 ClearOne, Inc. All rights reserved.

Information in this document is subject to change without notice. 800-000-000-20-01 Revision 1.0 June, 2013