background image

BMA CT

Beamforming Mic Array - Ceiling-Tile

Quick-Start Guide


background image

IMPORTANT SAFETY INSTRUCTIONS ......................................... 1
THE BMA CT .................................................................................. 2
QUICK-START OVERVIEW ............................................................ 3
CONNECTING THE ARRAYS ........................................................ 4

I/O C

OnneCtIOns

 .............................................................................. 4

P-L

Ink

 C

OnneCtIOns

 .......................................................................... 6

UPDATING ARRAY FIRMWARE .................................................... 8
TESTING THE ARRAYS ................................................................. 8

V

OLume

 & m

ute

 ................................................................................ 8

m

ICrOPhOne

 A

rrAy

 LeD I

nDICAtOrs

 ................................................... 8

m

ICrOPhOne

 A

rrAy

 O

rIentAtIOn

 ......................................................... 9

MOUNTING THE ARRAYS ........................................................... 10 

P

Lenum

 s

hIeLD

 

wIth

 s

eIsmIC

 C

AbLes

 ................................................. 10 

P

Lenum

 s

hIeLD

 I

nstALLAtIOn

 ............................................................. 11 

s

eIsmIC

 C

AbLes

 ............................................................................... 12

COMPLIANCE .............................................................................. 13

P

Art

 n

umbers

 ................................................................................ 13

s

uPPOrteD

 COnVerGe P

rO

 2 ...................................................... 13

 

ISOMETRIC DIAGRAMS.............................................................. 14  
SUPPORTED CONVERGE PRO 2 ............................................... 15

Table of Contents


background image

QUICK-START GUIDE

1

IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the other. A 
grounding type plug has two blades and a third grounding prong. The 
wide blade or the third prong are provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of 
the obsolete outlet.

10.  Protect the PoE injector’s power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the point where they 
exit from the apparatus.

11.  Only use attachments/accessories specified by the manufacturer. 
12.  Unplug the array during lightning storms or when unused 

for long periods of time.

13.  Refer all servicing to qualified service 

personnel. Servicing is required when the 
apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or 
objects have fallen into the apparatus, the apparatus has been exposed to 
rain or moisture, does not operate normally, or has been dropped.


background image

BMA CT

22

THE BMA CT

The BMA CT is a 2nd-generation Beamforming Microphone Array 
solution for ceiling-tile installations, featuring 24 microphones, and 
beamforming and adaptive-steering technology (think of it as smart 
beam selection) designed specifically for the CONVERGE

® 

Pro 2 (CP2) 

products: 128, 128D, 128T, 128TD, 128V, 128VD, 128VT, 128VTD, 120, 
, 48T, 48VT, 48VTD, and 48V. The arrays connect with the CONVERGE 
Pro 2 through a Peripheral Link (P-Link) port with either Regular (200 ft.) 
or Long Distance (650 ft.) P-Link cables. Three arrays are supported per 
CP2 via either regular or long-distance P-Link, and up to 6 arrays can be 
daisy-chained in one regular P-Link chain with a stack of two CP2 mixers. 
Power to the arrays is supplied through a Power-Over-Ethernet (PoE) 
or P-Link connection from CP2. The array comes in both a 24-inch and 
600mm size. There is also an adapter that converts the 600mm version 
to 625mm.

IMPORTANT: 

The BMA CT arrays can only be used with CP2 

systems. It is not compatible with CONVERGE Pro or first-
generation Beamforming Mic Array systems.

The latest version of the CP2 firmware and software can be found on the 
ClearOne website at:

http://www.clearone.com/resource-product-line?pid=1029

The latest version of the BMA CT firmware and Installation Guide can be 
found on the ClearOne website at:

http://www.clearone.com/resource-product-line?pid=1030


background image

QUICK-START GUIDE

3

QUICK-START OVERVIEW

Installing and using the BMA CT arrays in your CP2 site is subject to the 
following parameters:
1.  The arrays can only be used with CP2 systems.
2.  You must have a 128, 128D, 128T, 128TD, 128V, 128VD, 128VT, 

128VTD, 120, 48T, 48VT, 48VTD, and/or 48V. mixer in the site. The 
arrays will not work with standalone 012, 128SR, or 128SRD units.

3.  Connect up to 3 arrays (current) per CP2 unit, and up to 6 arrays 

per Regular P-Link chain with 2 CP2 unit stack. More CP2 units may 
be added to increase the number of arrays per site.

Q

uick

-S

tart

 P

rocedureS

These steps must be done in the following order to use the BMA CT in 
your CONVERGE Pro 2 site:
1.  Update the CONVERGE Pro 2 firmware to the latest version using 

CONVERGE Pro 2 CONSOLE software.

2.  Connect the array to the updated CONVERGE Pro 2 via the P-Link 

bus.

3.  Update the array firmware using CONVERGE Pro 2 CONSOLE. 

(The  array firmware can not be upgraded without an updated 
CONVERGE Pro 2.) 

4.  Test the array. 
5.  Mount the array.


background image

BMA CT

4

Power-source 

selection switch

Speakers out

P-Link

In

P-Link

Out

PoE

In

4

CONNECTING THE ARRAYS

Connect the BMA CT units to the CP2 unit via P-Link connections using 
CAT6-24AWG solid conductor RJ45 cables. 

The arrays must be powered by an external PoE source that supports 
Mode B type power delivery. (A PoE Network Switch generally will not 
work for this.) A PoE injector can either be connected to P-Link PoE port 
on the rack-mounted CP2 unit, or it can be connected directly to the ar-
ray’s PoE In port.
When driving 2x10W speakers, each array requires its own PoE injector.
When the PoE injector is connected to the CP2 unit’s P-Link PoE port, the 
CP2 unit’s P-Link Out port will provide both power and data communica-
tions to the array. If the PoE injector is connected directly to the array PoE 
In port, a second cable must be connected from the CP2 unit’s P-Link 
Out port to the array P-Link In port. (Note that the CP2 unit itself does not 
provide PoE power without an external PoE injector.)

i/o c

onnectionS


background image

QUICK-START GUIDE

5

QUICK-START GUIDE

5

ClearOne PoE power supply part number 910-3200-202 is recom-
mended, and will power up to three P-Link devices. Some third-party PoE 
injectors will work, but not all. Mode B PoE injectors that meet the PoE 
IEEE 802.3at specification should power three devices.
See also this app note:

http://www.clearone.com/sites/default/files/PoE_and_CP2_P-link_Periph-
eral_Products.pdf

The power-source-selection switch should be set towards PoE if the array 
is powered by PoE, or set towards P-Link if powered by P-Link.

S

Peaker

 u

Sage

When driving 2x10W speakers, each array requires its own PoE injector. 
Set the “Power Select” switch to “PoE In” when the speaker outputs will 
be used.


background image

BMA CT

6

PoE

P-Link

P-Link

Connecting 3 BMA CT units  to one CP2 Unit.

P-Link cables can vary in length up to 200 ft

BMA CT requires its own PoE (IEEE 802.3at-compliant) 

if speakers are driven

P-Link

(Power, Audio, Control)

CONVERGE Pro 2

PoE

PoE

PoE

2 x 10W

speakers

2 x 10W

speakers

2 x 10W

speakers

P-L

ink

 c

onnectionS


background image

QUICK-START GUIDE

7

PoE

PoE

Connecting 3 BMA CT units and 3 P-Link 

compatible devices to one CP2 unit.  

P-Link

(Power, Audio, Control)

CONVERGE Pro 2

Up to 200 ft.

P-Link

Up to 200 ft.

P-Link

Up to 200 ft.

P-Link

Up to 200 ft.

P-Link

Up to 200 ft.


background image

BMA CT

88

UPDATING ARRAY FIRMWARE

1.  Connect the P-Link cable between the CP2 units and the arrays.
2.  Connect the CP2 units with CONVERGE Pro 2 CONSOLE.
3.  Open the Firmware Loader screen.
4.  Browse for the  BMA_CT_vx.x.x.x.mdo file.
5.  Download the array firmware.
6.  The array(s) will default and reboot after the download of firmware.
7.  Units are fully upgraded. (All array units connected via the P-Link on 

the site are simultaneously updated.)

TESTING THE ARRAYS

The array must be added to the site using the CONVERGE Pro 2 
CONSOLE software. This software also provides the capability of 
configuring the beams (enable/disable) and other characteristics 
available in Configuration mode. Refer to the online help available with 
the CONVERGE Pro 2 CONSOLE software.

V

oLume

 & m

ute

These controls are available through the controller configured for your 
CONVERGE Pro 2 site.

m

icroPhone

 a

rray

 Led i

ndicatorS

The illuminated LED indicators on the face of the array change color 
when the microphone array is active/muted. You can choose colors to 
indicate either state, or even set the indicators to remain off by using 
CONVERGE Pro 2 CONSOLE to change Unit Properties for the array. 


background image

QUICK-START GUIDE

9

QUICK-START GUIDE

9

m

icroPhone

 a

rray

 o

rientation

The LED indicators should be oriented in the room according to the 
beam selection needs for optimal coverage. The diagrams below show 
the orientation of the LED indicators toward the head of the conference 
table with the resulting room coverage and beam mapping shown below. 
Please be certain to remove the orientation label from the perforated 
room panel before use.


background image

BMA CT

10

MOUNTING THE ARRAYS 

P

Lenum

 S

hieLd

 

with

 S

eiSmic

 c

abLeS

If installing both the plenum shield and seismic cables, four slots of 
approximately 1” length should be cut diagonally in the plenum shielding 
to match the points of seismic cable attachment. Otherwise, skip this step 
and go to page 11 for installation of plenum shield only or page 12 for 
isntallation of seismic cables only.


background image

QUICK-START GUIDE

11

P

Lenum

 S

hieLd

 i

nStaLLation

Remove the liner from adhesive in four places on underside of shielding, 
and thread cables through cut slots before attaching to ceiling. 


background image

BMA CT

12

S

eiSmic

 c

abLeS

 i

nStaLLation

The array can be ceiling-mounted in a suspended ceiling, held in place 
by the standard T-BAR grid, with additional 1/8” safety (seismic) cables 
(not included). Four attachment points are recommended for stability. If 
installing with the plenum shield, feed cables thru slots cut in earlier step 
(see Pg 10).
Detailed instructions are included in the BMA CT Installation Guide 
available on the ClearOne website: 

http://www.clearone.com/resource-product-line?pid=1030


background image

QUICK-START GUIDE

13

Part Numbers

Item

Part No.

White BMA CT 24” 

910-3200-205

White BMA CT 600mm 

910-3200-205-I

PoE Power Supply Kit

910-3200-202

50 Ft RJ45 CAT6 Cable

910-3200-204-50

100 Ft RJ45 CAT6 Cable

910-3200-204-100

150 Ft RJ45 CAT6 Cable

910-3200-204-150

200 Ft RJ45 CAT6 Cable

910-3200-204-200

COMPLIANCE

Details on compliance can be found on the ClearOne website under 
“Resource Library”.


background image

BMA CT

14

ISOMETRIC DIAGRAMS

Side

 

ViewS

 

back

 

View


background image

QUICK-START GUIDE

15

© 2019 ClearOne, Inc. All rights reserved.

Information in this document is subject to change without notice.  QSG-0074-001 Rev 2.4 Mar 2019

Headquarters:

5225 Wiley Post Way
Suite 500
Salt Lake City, UT 84116

Tel:

 801.975.7200

Sales:

 800.707.6994 

US & Canada

Tel:

 801.975.7200

Toll Free:

 800.945.7730

Fax:

 801.303.5711

International

Tel:

 

+1.801.975.7200

e-mail: 

global@clearone.com

Sales

Tel:

 801.975.7200

e-mail:

 sales@clearone.com

TechSupport

Tel:

 801.974.3760

e-mail: 

tech.support@clearone.

com

CLEARONE LOCATIONS

Supported CONVERGE Pro 2

Item

Part No.

CONVERGE Pro 2 128

910-3200-001

CONVERGE Pro 2 128D

910-3200-001-D

CONVERGE Pro 2 128T

910-3200-002

CONVERGE Pro 2 128TD

910-3200-002-D

CONVERGE Pro 2 128V

910-3200-003

CONVERGE Pro 2 128VD

910-3200-003-D

CONVERGE Pro 2 128VT

910-3200-009

CONVERGE Pro 2 128VTD

910-3200-009-D

CONVERGE Pro 2 48T

910-3200-005

CONVERGE Pro 2 48V

910-3200-006

CONVERGE Pro 2 48VT

910-3200-008

CONVERGE Pro 2 48VTD

910-3200-008-D

CONVERGE Pro 2 120

910-3200-004