PDF User Manual

  1. Home
  2. Manuals
  3. ClearOne BFM2 Quick Start Manual

ClearOne BFM2 Quick Start Manual

Made by: ClearOne
Type: Quick Start Guide
Category: Microphone
Pages: 10
Size: 0.45 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

Beamforming Microphone Array 2

Group Microphone for Professional Conferencing

Quick-Start Guide

 


background image

THE BEAMFORMING MICROPHONE ARRAY 2 ...............................1
QUICK-START OVERVIEW ................................................................2
CONNECTING THE BFM2  ................................................................3
UPDATING THE BFM2 FIRMWARE ..................................................4
TESTING THE MICROPHONE ARRAY ..............................................4

V

olume

 

and

 m

ute

 .................................................................................5

m

icrophone

 a

rray

 i

ndicators

 ...............................................................5 

MOUNTING THE BFM2 .....................................................................5
COMPLIANCE ....................................................................................6
PART NUMBERS

...................................................................................

6

Table of Contents

 


background image

QUICK-START GUIDE

1

THE BEAMFORMING MICROPHONE ARRAY 2

The Beamforming Microphone Array 2 (BFM2) is a 2nd generation 
Beamforming Microphone Array product featuring 24 microphones, 
beamforming and adaptive steering technology designed specifically for 
the CONVERGE® Pro 2 products: 128, 128D, 128T, 128TD, 128V, 128VD, 
120, and 48T. The BFM2 connects with the CONVERGE Pro 2 through a 
Peripheral Link (P-Link) port. 3 arrays per supported CONVERGE Pro 2 
and up to 6 BFM2s can be daisy-chained in one P-Link chain. The Power 
for the BFM2 is supplied through a Power-Over-Ethernet (PoE) or P-Link 
connection from CONVERGE Pro 2.
The BFM2 is supported for use as a ceiling-mounted, wall-mounted or 
tabletop assembly.

IMPORTANT: 

The BFM2 only can be used with CONVERGE 

Pro 2 systems. It is not compatible with CONVERGE Pro or first 
generation Beamforming Microphone Array systems.

The latest version of the CONVERGE Pro 2 firmware can be found on the 
ClearOne website at:

http://www.clearone.com/resources#professional_audio

The latest version of the BFM2 firmware and the Beamforming 
Microphone Array 2 Installation Guide can be found on the ClearOne 
website at:

http://www.clearone.com/resources#professional_microphones

 


background image

BEAMFORMING MICROPHONE ARRAY 2

2

QUICK-START OVERVIEW

Installing and using the BFM2 in your CONVERGE Pro 2 site is subject to 
the following rules:
1.  The BFM2 can only be used with CONVERGE Pro 2 systems.
2.  You must have a CONVERGE Pro 2 128, 128D, 128T, 128TD, 128V, 

128VD, 120, and/or 48T in the site. The BFM2 will not work with 
standalone 128SR or 128SRD units.

3.  You can have up to 3 BFM2s per valid CONVERGE Pro 2 unit up 

to a total of 6 BFM2s per P-Link chain. More valid CONVERGE Pro 
units may be added to increase the number of BFM2s per site.

Quick Start Procedures

These steps must be done in the following order to use the BFM2 in your 
CONVERGE Pro 2 Site:
1.  Update the CONVERGE Pro 2 firmware to the latest version using 

CONVERGE Pro 2 CONSOLE software.

2.  Connect the BFM2 to the updated CONVERGE Pro 2 via the P-Link 

bus.

3.  Update the BFM2 firmware using CONVERGE Pro 2 CONSOLE. 

(The  BFM2 firmware can not be upgraded directly without an 
updated CONVERGE Pro 2.) 

4.  Test the BFM2 
5.  Mount the BFM2

 


background image

QUICK-START GUIDE

3

CONNECTING THE BFM2

Connect the BFM2 units to the CONVERGE Pro 2 via the P-Link 
connections using CAT6-24AWG solid conductor RJ45 cables. 

The BFM2 can be powered via a P-Link

1

 from CONVERGE Pro 2 (a single 

cable carries power, audio and control), a PoE power supply

2

 (external 

or ClearOne; a maximum of three BFM2 units can be powered by one 
ClearOne PoE Injector),or a standard PoE switch

3

The power-source-selection switch should be set towards PoE if the 
BFM2 is powered by PoE, or set towards P-Link if powered by P-Link.

power-source-selection 

switch

(for future use)

1

1

2 3

 


background image

4

Daisychain Examples

Example 1

 shows a basic daisychain of three BFM2 arrays to a single 

CONVERGE Pro 2 unit:

Example 2

 illustrates a daisychain of four BFM2 arrays to two 

CONVERGE Pro 2 units:

 


background image

QUICK-START GUIDE

5

UPDATE BFM2 FIRMWARE

1.  Connect the P-Link cable between the CONVERGE Pro 2 units and 

the BFM2s.

2.  Connect the CONVERGE Pro 2 units with CONVERGE Pro 2 

CONSOLE.

3.  Open the Firmware Loader screen.
4.  Browse for the bf2_mic.mdo file.
5.  Download the BFM2 firmware.
6.  The BFM2(s) will default and reboot after the download of firmware.
7.  Units are fully upgraded. (All BFM2 units connected via the P-Link 

on the site are simultaneously updated.)

8.  Restore the saved site file to the system using CONVERGE Pro 2 

CONSOLE.

TEST THE BFM2

The BFM2 must be added to the site using the CONVERGE Pro 2 
CONSOLE software. This software also provides the capability of 
configuring the beams (enable/disable) and other characteristics 
available in Configuration mode. Refer to the online help available with the 
CONVERGE Pro 2 CONSOLE software.

V

olume

 & m

ute

These controls are available through the controller configured for your 
CONVERGE Pro 2 site.

 


background image

6

m

icrophone

 A

rrAy

 leD i

nDicAtors

The illuminated microphone indicators at the ends of the BFM2 show 
blue/red when the microphone array is active/muted. You can set the 
indicators to remain off by using CONVERGE Pro 2 CONSOLE to change 
Unit Properties for the BFM2. See the help file for more details.

MOUNT THE BFM2

The array can be ceiling-mounted in either a suspended or solid ceiling, 
or on a wall-mount assembly with the PoE or P-Link wiring passing 
through the mounting assembly and plugging into the BFM2 unit. 

Tabletop use is also supported with PoE or P-Link cables attached under 
the unit. 

NOTE: 

1st Gen BFM mounting kits are compatible with 2nd Gen 

BFM2 unit and vice versa.

Detailed instructions are included in the BFM2 Installation Guide 
available on the ClearOne website:

http://www.clearone.com/resources#professional_microphones

 


background image

QUICK-START GUIDE

7

Part Numbers

Item

White color SKU

Black color SKU

Beamforming Microphone Array 2

910-3200-201

910-3200-201-B

BMF2 Ceiling Mount kit with 12” Suspension Column

910-3200-203-12

910-3200-203-12-B

BMF2 Ceiling Mount kit with 24” Suspension Column

910-3200-203-24

910-3200-203-24-B

BMF2 Ceiling Mount kit with 36” Suspension Column

910-3200-203-36

910-3200-203-36-B

BMF2 Ceiling Mount kit with 48” Suspension Column

910-3200-203-48

910-3200-203-48-B

BMF2 Ceiling Mount kit without Suspension Column

910-3200-203

910-3200-203-B

BFM Ceiling Mount kit with 12” suspension column

910-001-005-12

910-001-005-12-B

BFM Ceiling Mount kit with 24” suspension column

910-001-005-24

910-001-005-24-B

BFM Ceiling Mount kit with 36” suspension column

910-001-005-36

n/a

BFM Ceiling Mount kit with 48” suspension column

910-001-005-48

n/a

BFM Wall Mount

910-001-006

910-001-006-B

PoE Power Supply Kit

910-3200-202

50 Ft RJ45 CAT6 Cable

910-3200-204-50

100 Ft RJ45 CAT6 Cable

910-3200-204-100

150 Ft RJ45 CAT6 Cable

910-3200-204-150

200 Ft RJ45 CAT6 Cable

910-3200-204-200

COMPLIANCE

Details on compliance can be found on the ClearOne website under 
“Resource Library”.

 


background image

BEAMFORMING MICROPHONE ARRAY

8

© 2016 ClearOne, Inc. All rights reserved.

Information in this document is subject to change without notice. QSG-0031-001 Rev 1.0 AUGUST 2016

HEADQUARTERS:

Salt Lake City, UT USA

5225 Wiley Post Way
Suite 500
Salt Lake City, UT 84116

Tel:

 801.975.7200

Toll Free:

 800.945.7730

Sales:

 800.707.6994 

Fax:

 801.303.5711 

e-mail:

 sales@clearone.com

Europe

Tel:

 +44.1454.616.977

UK Tech Support:

+44.0800.680.0682

e-mail:

 global@clearone.com

Asia Pacific

Tel:

 

+86.138.23287825

Tech Support:

 

+86.18420152949

e-mail: 

global@clearone.com

Middle East

Tel:

 +

91.9930782195

e-mail: 

global@clearone.com

TechSales

Tel:

 800.705.2103

e-mail: 

techsales@clearone.

com

Technical Support

Tel:

 800.283.5936

Tel:

 801.974.3760

e-mail: 

tech.support@clearone.

com

CLEARONE LOCATIONS