Full Text Searchable PDF User Manual

VIEW™
SLX300 S
peaker
L
in
X™
ip Z
one
a
mpLifier
i
nStaLLation
and
S
etup
G
uide
TM
AVoIP™

ClearOne
5225 Wiley Post Way
Suite 500
Salt Lake City, UT 84116
Telephone 1.800.283.5936
1.801.974.3760
Tech Sales
1.800.705.2103
FAX
1.801.974.3669
tech.support@clearone.com
support@netstreams.com
On the Web
www.clearone.com
www.netstreams.com
www.streamnetpartners.com
V
iew
SLX300 S
peaker
L
in
X ip Z
one
a
mpLifier
i
nStaLLation
and
S
etup
G
uide
C
Lear
o
ne
d
oCument
800-000-000-08 Rev 1.1 - June 13, 2012
© 2012 ClearOne and NetStreams - All rights reserved. No
part of this document may be reproduced in any form or
by any means without written permission from ClearOne
and NetStreams. Printed in the United States of America.
ClearOne and NetStreams reserves specific privileges.
Information in this document is subject to change without
notice.

Important Safety Notices ...................................................... 4
Chapter 1: Installing the SLX300 .......................................... 5
Connections and Indicators ............................................................................5
Ethernet Connection .....................................................................................6
EIM Connection (Expansion Interface Module) ...........................................6
Speaker Connections ...................................................................................6
Balanced Audio Connections .......................................................................6
LED Indicators ..............................................................................................7
Monitoring Jack ............................................................................................7
Power Connection ........................................................................................7
Chapter 2: SLX300 Setup ..................................................... 8
SLX300 Screens in the Dealer Setup Program ...............................................8
Adding an SLX300 to a Project ....................................................................8
Configuring the SLX300 ..............................................................................9
Chapter 3: Mounting Options .............................................. 13
Chapter 4: Compliance........................................................ 16
Chapter 5: Service and Support ......................................... 17
Table of Contents

4 TechSales StreamNet Design Help: 1.800.705.2103
Important Safety Notices
Read these warnings, heed all warnings, and keep for future reference.
• Clean only with a dry cloth.
• Do not use this apparatus near water.
»
CAUTION: To reduce the risk of electrical shock, do not expose
this appliance to rain or moisture. Equipment must not be
exposed to dripping or splashing and no objects filled with
liquids, such as vases, must be placed on the equipment.
• The mains socket outlet must provide a Class 1 Protective Earthing Connection
where the outlet has a protective earth (ground) connection.
• This device uses a polarized, or grounding-type plug. Do not defeat the safety
purpose of the plug. A polarizing plug has two blades with one wider than the
other, A grounding-type plug has two blades and a third grounding prong.
The wide blade or third prong is provided for safety. If the provided plug does
not fit into your outlet, consult an electrician for replacement of the obsolete
outlet.
• The mains plug or appliance connector shall be used as the disconnect
device, so the mains plug or appliance connector should always remain
readily operable.
• Audio outputs - Use “Class II Wiring” speaker cables.
• Do not block any ventilation openings. Install in accordance to the
manufacturers instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves
or other apparatuses (including amplifiers) that produce heat.
• Only use attachments/accessories specified by the manufacturer.

Chapter 1: Installing the SLX300
5
Chapter 1: Installing the SLX300
The SLX300 SpeakerLinX is a high power, networked audio amplifier. This amplifier
may be mounted any distance from the speaker location; however, longer speaker
wires may result in some distortion of the audio waveform. In addition to being a
very capable amplifier, the SLX300 can also function as the zone or room controller
and has a built-in web server which can provide a user interface. Each zone of
audio must have at least one SpeakerLinX. Combining the amplifier and room
controller, and connecting local audio sources to the SpeakerLinX minimizes the
amount of cabling required to accomplish multiple functions.
»
NOTE: The SLX300 and the SLX300i are identical except for the
power input. The SLX300 is the 120 Volt, US model, and the
SLX300i is the 240 Volt, International model.
CONNECTIONS AND INDICATORS
The SLX300 has connections for the following:
• 10/100Mb Ethernet (RJ45)
• Two +4 dBu Stereo Balanced Audio Inputs (3.5mm, 2 x 3 pin Phoenix-style)
• Two +4 dBu Stereo Balanced Audio Outputs (3.5 mm, 2 x 3 pin Phoenix-style)
• Two Stereo Speaker Outputs (7.5mm, 2 x 2 pin Phoenix-style)
• IEC Power Cord Inlet (according to US or International model ordered)
• StreamNet EIM (RJ45)
• Monitoring Jack (1/4-inch, on front)
Stereo
Speaker
Outputs
Stereo
Balanced
Audio
Outputs
EIM for Audio
Port, BluePort,
IRLinX or
KeyLinX
Ethernet
Network
Power
Cord
Input
On/Off
Switch
Stereo
Balanced
Audio
Inputs
Fuse
Access

6 TechSales StreamNet Design Help: 1.800.705.2103
Monitoring
Jack
Power/
Status
LED
e
thernet
C
onneCtion
The 10/100 Ethernet connector allow connection to a TCP/IP network that is setup
to run StreamNet. Using a standard (straight through) Category-5 or Category-6
Ethernet cable, connect the Ethernet port on the SLX300 to an available port on
your network router or switch.
eim C
onneCtion
(e
XpanSion
i
nterfaCe
m
oduLe
)
Using a standard (straight through) Category-5 or Category-6 Ethernet cable,
connect the EIM port on the SLX300 to any EIM compatible accessory. This in-
cludes BluePort, KeyLinX, IRLinX, any Audio Port, or EIM enabled external ampli-
fiers.
»
NOTE: The EIM splitter is required to install a KeyLinX or IRLinX.
It is shipped in the same box with the KeyLinX and IRLinX.
S
peaker
C
onneCtionS
Connect the left/right speaker audio outputs to the intended speakers. Use the
supplied 2-pin, 7.5mm screw cage connectors to adapt your cable to the output
plugs. Each speaker connector has an LED which is normally off, but turns red
when the related corresponding channel experiences a fault.
B
aLanCed
a
udio
C
onneCtionS
Balanced analog audio input and output allows for the use of longer cables while
reducing susceptibility to external noise. Use the supplied 3-pin, 3.5mm screw
cage connectors to adapt your cable to the input plugs.
The inputs allow external devices to supply audio to the SLX300 which is amplified
for output on the stereo speaker outputs. The audio is also encoded within the
SLX300 for access by other devices in the StreamNet network.
Balanced audio outputs can be used to connect to other amplifiers and audio
devices.

Chapter 1: Installing the SLX300
7
Led i
ndiCatorS
The front panel indicator glows blue as soon as power is applied, but turns red
when either channel amplifier experiences a fault.
The balanced input has two LEDs on the back panel by the connectors, one per
channel. The LEDs are green when there is audio activity. They turn red when the
input signal is too high and being clipped.
Each speaker connector on the back panel has an LED, they are off in normal
operation, turning red if the amplifier is overloaded or otherwise has a fault.
m
onitorinG
J
aCk
The 1/4” jack on the front of the unit allows direct monitoring of the speaker
outputs. This jack provides a voltage output -21dB below that of the speaker
output (open circuit) with an output impedance of 91 ohms. This jack is suitable
for listening with headphones.
p
ower
C
onneCtion
»
CAUTION: To reduce the risk of electric shock, grounding of the
center pin of this plug must be maintained.

8 TechSales StreamNet Design Help: 1.800.705.2103
Chapter 2: SLX300 Setup
The SLX300 is setup for use in a commercial or residential network using the
StreamNet Dealer Setup program and the StreamNet Dealer Setup manual.
StreamNet Dealer Setup is a PC-based program that allows you to configure
devices so that they can communicate across a StreamNet network. Phases of
the software setup include:
• Adding or creating a new project or opening an existing project
• Finding the new device
• Matching the new Anthology physical hardware device to the hardware setup
in the project
• Configuring the device with system-specific information
• Saving the project
• Sending the configuration files to the system
The steps involved in these processes are detailed in the DigiLinX Dealer Setup
manual available for viewing or download at www.netstreams.com.
SLX300 SCREENS IN THE DEALER SETUP PROGRAM
When you start Dealer Setup program, the SLX300 will be automatically detected
like any other DigiLinX device. Verify the configuration information on the tabs for
the device as shown in the following screen examples:
a
ddinG
an
SLX300
to
a
p
roJeCt
1. Enter the following information:
Room Name
- Room or Zone name for this device.
Model Number
- Select from the drop-down list (using the down arrow key)
to select the correct model number for this device.

Chapter 2: SLX300 Setup
9
Audio Port Name
- If you are installing an Audio Port in that room, you can
name the source input connected to that Audio Port (such as MP3 Player).
Enable Audio Port Service
- Enable the Audio Port service only if you
intend to install an Audio Port in that room. The Audio Port connects to the
RJ45 jack labeled EIM on the SpeakerLinX.
IR/KeyLinX
- This drop-down menu lets you select from two models of Key-
LinX (KL10X and KL20X), one model of IRLinX (IRL1), and two combination
models (for chaining an IRLinX off a KeyLinX) (IRL1 & KL10X, and IRL1 &
KL20X). The KL20X offer a microphone and a TALK button for the IP in-
tercom feature. The KL10X and KL20X provide an IRLinX port on the back
panel. KeyLinX or IRLinX connects to the Expansion Interface Module (EIM)
port on a SpeakerLinX.
»
NOTE: The EIM splitter is required to install a KeyLinX or IRLinX. It
is shipped in the same box with the KeyLinX and IRLinX.
Speaker Mode
- This option is designed for IP-Ready speakers which are
specifically labeled by your speaker manufacturer. Selecting this option loads
the filter and crossover arrangements designed by your speaker manufac-
turer into the signal processor of the SpeakerLinX, thereby enabling greater
performance out of your SpeakerLinX.
2. After completing the information, click
Save & Continue
.
C
onfiGurinG
the
SLX300
Adjust the settings for each SLX300 connected to the system by filling in the ap-
propriate fields on each of the tabs
.
(Refer to the Dealer Setup manual for com-
plete descriptions of each tab and field.)
The following examples show the screens used to configure the SLX300.

10 TechSales StreamNet Design Help: 1.800.705.2103
SLX300 Dealer Setup - Info Tab
SLX300 Dealer Setup - Audio Tab

Chapter 2: SLX300 Setup
11
SLX300 Dealer Setup - Stream Tab
SLX300 Dealer Setup - IR/KeyLinX Tab

12 TechSales StreamNet Design Help: 1.800.705.2103
SLX300 Dealer Setup - IR/Tab

Chapter 3: Mounting the SLX300
13
Chapter 3: Mounting the SLX300
By varying the use of the included mounting brackets, screws and the joiner plate,
one or two SLX300 units can be mounted in different ways:
• Under surface mount
• Wall mount or top surface mount
• Rack mount (dual with joiner plate)
The following illustrations show how each of these is accomplished using the
mounting brackets, screws, filler plate and the joiner plate:
Brackets Attached for Under
Surface Mount

14 TechSales StreamNet Design Help: 1.800.705.2103
Brackets Attached for Wall or
Top Surface Mount
Underside of Two SLX300s Prepared for Front Attach-
ment Rack Mount with Joiner Plate

Chapter 3: Mounting the SLX300
15
Two SLX300s Prepared for Front Attachment Rack Mount
with Joiner Plate
Two SLX300s Prepared for Rear Attachment Rack Mount
with Joiner Plate

16 TechSales StreamNet Design Help: 1.800.705.2103
Chapter 4: Compliance
C
ompLianCe
o
VerView
UL Compliance
This equipment is compliant with applicable UL (Underwriters Laboratory) safety
standards.
RoHS Compliance
All components and processes used to produce the SLX300 complies with the
RoHS initiative.
Sustainability
The SLX300 is compliant with the WEEE recycling initiative. It is made from easily
recyclable materials such as aluminum and steel.
Electrical Safety Advisory
This equipment uses AC power which can be subjected to electrical surges,
typically lightning transients which are very destructive to customer terminal
equipment. The warranty for this equipment does not cover damage caused
by electrical surge or lightning transients. To reduce the risk of this equipment
becoming damaged it is suggested that the customer consider installing a surge
arrestor.
Any modifications to the device without express authorization from ClearOne is
prohibited as per 47CFR15.21 and could void the users authority to operate the
device.
European Compliance
Details on European equipment compliance can be found on the ClearOne
website at the following location: www.ClearOne.com/resources/EuroDOC.php.

Chapter 5: Service and Support
17
Chapter 5: Service and Support
If you need assistance setting up or operating your product, please contact us.
We welcome your comments so we can continue to improve our products and
better meet your needs.
t
eChniCaL
S
upport
Telephone: 1.800.283.5936
E-mail:
tech.support@ClearOne.com
Web site:
www.ClearOne.com, www.NetStreams.com
S
aLeS
Telephone: 1.800.707.6994
E-mail:
sales@ClearOne.com
t
eCh
S
aLeS
Telephone: 1.800.705.2103
E-mail:
techsales@ClearOne.com
p
roduCt
r
eturnS
All product returns require a Return Material Authorization (RMA) number. Contact
ClearOne Technical Support before returning your product. Make sure you return
all the items and packing materials that originally shipped with your product.
HEADQUARTERS:
Salt Lake City, UT USA
5225 Wiley Post Way
Suite 500
Salt Lake City, UT 84116
Tel:
801.975.7200
Toll Free:
800.945.7730
Fax:
801.977.0087
e-mail:
sales@clearone.com
EMEA
Tel:
44 (0) 1189.036.053
e-mail:
global@clearone.com
APAC
Tel:
801.303.3388
e-mail:
global@clearone.com
LATAM
Tel:
801.974.3621
e-mail:
global@clearone.com
CLEARONE LOCATIONS
The Power of AV over IP™