background image

 
 

 

 

 
 
 
 

 

 

IEC INSTALLATION INSTRUCTION AND 

MAINTENANCE MANUAL 

FOR CRYSTALLINE SOLAR PV MODULE

 

 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 1 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

1.

 

INTRODUCTION 

 

This installation instruction manual provides information about CNPV Crystalline Solar Photovoltaic Modules. 
CNPV Dongying Solar Power Company Limited has a history of successful innovation within the Solar Industry. 
The company was founded in 2006 and has made significant investments in research and development, creating over 
10 patents during the company’ history. 
 
The company has several fully integrated product lines including ingots, casting, wafers, Cells and Modules of Mono 
and Poly crystalline, and those products are also exported to overseas markets. With an experienced international 
management team and a strong reputation for innovation, CNPV is one of the leaders in China’s Solar Energy Sector 
and provides the highest quality SPV Modules in a range of sizes designed to meet the requirements of the most 
demanding energy and power users worldwide. 
 

2.

 

POWER MODULE 

 

CNPV Solar Photovoltaic Modules consist of a series of electrically interconnected crystalline silicon solar cells, 
which are permanently encapsulated between a low iron toughened glass superstrate and substrate. The entire 
laminate is secured within an anodized aluminum frame for structural strength; ease of installation and to protect the 
cells from the most severe environmental conditions. 
 

3.

 

APPLICATIONS 

 

CNPV SPV Modules are a highly reliable, virtually maintenance-free direct current (DC) power source, designed to 
operate most efficiently in sunlight. CNPV series Modules are ideal to power remote homes, recreational vehicles, 
water pumps, telecommunication systems and many other applications either with or without the use of storage 
batteries. 
 

4.

 

PERMIT 

 

Before installing your system, contact local authorities to determine the necessary permit, installation and inspection 
requirements. 
 

5.

 

CLIMATE CONDITION 

 

Install the CNPV Solar Photovoltaic Crystalline series Modules in the following conditions: 
 

 

Ambient temperature:                      -20°C to +40°C. 

 

Operating temperature:                    -40°C to +85°C. 

 

Storage temperature:                        -40°C to +40°C,  

 

Humidity:                                          below 85RH% 

 

Wind pressure:                                  below 50.12lb / ft

2

 (2400Pa). 

 

Snow Load Pressure:                         below 112.76lb / ft

2

 (5400Pa). 

 

Corrosion resistance:                         Except for heavy corrosive salt area and sulfurous area. 

 

 
 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 2 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

6.  SITE SELECTION 

 
In most applications, CNPV SPV Modules should be installed in a location where they will receive maximum 
sunlight throughout the year. In the Northern Hemisphere, the Module should typically face south, and in the 
Southern Hemisphere, the Modules should typically face north. Modules facing 30 degrees away from true South (or 
North) will lose approximately 10 to 15 per cent of their power output. If the Module faces 60 degrees away from 
true South (or North), the power loss will be 20 to 30 per cent. 
 
When choosing a site, avoid trees, buildings or obstructions, which could cast shadows on the solar photovoltaic 
Modules especially during the winter months when the arc of the sun is lowest over the horizon. Shading causes loss 
of output, even though the factory fitted bypass diodes of the SPV Module will minimize any such loss. 
 
Do not install the SPV Module near naked flame or flammable materials. 
 
Do not install the SPV Module in a location where it would be immersed in water or continually exposed to water 
from a sprinkler or fountain etc. 
 

7.

 

MODULE TILT ANGLE 

 
CNPV SPV Modules connected in series should be installed at same orientation and angle. Different orientation or 
angle may cause loss of output power due to difference of amount of sunlight exposed to the Module. 

 

CNPV SPV Modules produce the most power when they are pointed directly at the sun. For installations where the 
SPV Modules are attached to a permanent structure, the SPV Modules should be tilted for optimum winter 
performance. As a rule, if the system power production is adequate in winter, it will be satisfactory during the rest of 
the year. The Module tilt angle is measured between the solar Modules and the ground (Figure 1). Optimal tilting of 
SPV Module is almost the same as the latitude of installation location. 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

SUNLIGHT 

TILT ANGLE

MODULE 

HORIZONTAL

Figure 1 SPV Module Tilt Angle 

 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 3 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

 

8. MOUNTING AND NOTES 

 
Systems should be installed by qualified personnel only. It involves electricity, and can be dangerous if the personnel 
are not familiar with the appropriate safety procedures. 

 
The Module frame is made of anodized aluminum, and therefore corrosion can occur if the Module is subject to a 
salt water environment with contact to a rack of another type of metal (Electrolysis Corrosion). If required, PVC or 
stainless steel washers can be placed between the SPV Module frame and support structure to prevent this type of 
corrosion. Module support structures that are to be used to support SPV Modules at correct tilt angles should be wind 
and snow load rated for use by the appropriate local and civil codes prior to installation. 

 
CNPV SPV Modules can be mounted as following method: 

             

 

   

 

 

 

Figure 2 Mounting Method a and b 

 
a)

 

Using corrosion-proof screws (M8) on the existing installing holes (see drawing 1, 3, 5 & 7) in the Module 
frame. The frame of each Module has 4 or 8 mounting holes (12mm×9mm) used to secure the Modules to 
supporting structure. The Module frame must be attached to a supporting rack using M8 stainless steel hardware 
together with spring washers and flat washers in four places symmetrical on the SPV Module. See method a of 
figure 2. The applied torque is about 8 Newton-meters. 

b)

 

 Using suitable Module clamps on the Module frame, see method b of figure 2. The module frame must be 
attached to supporting rack using M8 stainless steel hardware together with corrosion-proof clips in four places 
on the SPV module. See drawing 10, 12, 14 & 16, 

with clamping clip, 

for positioning of clamping clips. The 

applied torque is about 8 Newton-meters. See figure 3 if clamping mounting is on short frames of the module. 
 

 

W

idth

1/

4W

1/4

W

Length

 

c)

 

Insertion System 

Method a: Using corrosion-proof 

screws on existing Installation 

Method b. Using suitable module 
clamps on the module frame 

Using Short sides for module clamping. W 
means module width, and 1/4W means 
permissible clamping range.  
 

Figure 3. Mounting on short frames. 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 4 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

 

NOTES: 
 

(1) The Module clamps must not come into contact with the front glass and must not deform the frame. Avoid 
shadowing effects from the Module clamps and the insertion systems. It is not permitted to modify the Module frame 
under any circumstances. Recommended distance between 2 Solar Modules is 5mm considering linear thermal 
expansion of the Module frames. 
(2) Clearance between the Module frame and mounting surface may be required to prevent the junction box from 
touching the surface, and to circulate cooling air around the back of the Module.  

(3) The Modules are not designed for integral mounting as part of a roof or wall. The mounting design may have an 
impact on the fire resistance. If the Modules are to be installed on the roof or wall of a building, the fire resistance of 
roof covering or wall should be rated for the application. Here the standoff method or the rack method is 
recommended. The Modules are supported parallel to surface of the building wall or roof. Clearance between the 
Module frames and surface of the wall or roof is required to prevent wiring damage and to allow air to circulate 
behind the Module. The recommended stand-off height is 115mm. Any slope less than 5in/ft (127mm/305mm) 
required to maintain a fire class rating. Do not mount SPV Module in such way that the drain holes of SPV Module 
are intended to block up. 
(4) Do not step on the Module, although SPV Modules are quite rugged, the glass can be broken (and the Module 
will no longer work properly) if it is dropped or hit by tools or other objects. 

 

9.  GROUNDING 

 
All Module frames and mounting racks must be properly grounded in accordance with the local regulations. Proper 
grounding is achieved by connecting the Module frame(s) and structural members contiguously one to another using 
a suitable grounding conductor. The grounding conductor or strap may be copper, copper alloy, or other material 
acceptable for use as an electrical conductor per local regulations. The grounding conductor must then make a 
connection to earth using a suitable earth ground electrode.   
 
Attach a separate conductor to one of the 
 4mm diameter grounding holes marked 

 ' 

 ' on the Module frame with a screw 

and nut that incorporates an external tooth 
washer. This is to ensure positive electrical 
contact with the frame.  
 
 
 
The rack must also be grounded unless they are mechanically connected by nuts and bolts to the grounded SPV 
Modules. The array frame shall be grounded in accordance with local regulations. 
 
 
 
 
 
 
 

Figure 4 Schematic drawing 
 for SPV Module grounding 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 5 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

 

10.  BYPASS DIODES AND BLOCKING DIODES  

 
Partial shading of an individual Module can cause a reverse voltage across the shaded SPV Module. Current is then 
forced through the shaded area by the other Modules. 
 
When a bypass diode is wired in parallel with the series string, the forced current will flow through the diode and 
bypass the shaded SPV Module, thereby minimizing Module heating and array current losses. 
 
In system utilizing a battery, blocking diodes are typically placed between the battery and the SPV Module output to 
prevent battery discharge at night. 
 
Diodes that are used as blocking diodes must: Have a Rated Average Forward Current [I

F(AV)

above

 maximum 

system current at highest Module operating temperature. Have a Rated Repetitive Peak Reverse Voltage [V

RRM

above

 maximum system voltage at lowest Module operating temperature. 

 
11. WARNING AND NOTES 

 
The SPV Modules generate electricity when exposed to light. Array of many Modules can cause lethal electrical 
shock and burn hazards. Only authorized and trained personnel should have access to these Modules. To reduce the 
risk of electrical shock or burns, modules maybe covered with an opaque material during installation to avoid 
electrical shocks or burns. Do not touch live terminals with bare hands. Use insulated tools for electrical connections. 
 
Use appropriate methods to mount SPV Modules. Fall of Modules from high place will cause death, injury or 
damage. 
The SPV Module has a pair of male and female waterproof connectors. For a series electrical connection, connect 
positive (+) connector of first SPV Module to negative (-) connector of the following Module. 
Do not short the positive and the negative. Do not disconnect under load. Be sure connectors have no gap between 
the insulators. In case there is a gap, a fire and/or an electrical shock may occur.  
 
 
NOTES: 
 
(1) Artificially concentrated sunlight shall not be directed on the SPV Module. The rated electrical characteristics are 
within 10 percent of measured values under standard test conditions (Irradiance of 1000W/m

2

, AM 1.5 spectrum, and 

cell temperature of 25°C). 
(2) Under normal conditions, a solar photovoltaic Module is likely to experience conditions that produce more 
current and/or voltage than reported at standard test conditions. Accordingly the value of Isc and Voc marked on this 
Module should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor current 
ratings, fuse sizes, and sizes of controls connected to the SPV output.  
 (3) Details for wiring in accordance with the local regulations. 
(4) If you install modules in parallel electrically, each module (or series string of modules so connected) shall be 
provided with the maximum series fuse as specified. 
 
 
 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 6 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

12.  MODULE WIRING 
 

Each Module has two #12 AWG type standard 90°C sunlight resistant output cables each terminated with plug & ply 
connectors. This cable is suitable for applications where wiring is exposed to the direct rays of the Sun. We 
recommend that all wiring and electrical connections comply with local regulations. 
 
For field connections, use the minimum No. #12 AWG copper wires insulated for a minimum of 90°C and sunlight 
resistant as well. The minimum and maximum outer cable diameters of the cable are 5 to 7mm. Refer to table 1 for 
the maximum electrical rating of series fuse. 
 

13.  TYPE OF PRODUCT APPLICATION 
 

“The modules are qualified for application class A: Hazardous voltage (IEC61730: higher than 50V DC; EN61730: 
higher than 120V), hazardous power applications (higher than 240W) where general contract access is anticipated 
(Modules qualified for safety through EN IEC61730-1 and EN IEC61730-2 within this application class are 
considered to meet the requirements for Safety class II)” 
 

14. MAINTENANCE 
 

Under most weather conditions, normal rainfall is sufficient to keep the SPV Module glass surface clean. If dirt 
build-up becomes excessive, clean the glass only with a soft cloth using mild detergent and water. USE CAUTION 
WHEN CLEANING THE BACK SURFACE OF THE MODULE TO AVOID PENETRATING THE SUBSTRATE 
MATERIALS. SPV Modules that are mounted flat (0° tilt angle) should be cleaned more often, as they will not ''self 
clean'' as effectively as Modules mounted at a 15° tilt or greater. Once a year, check the tightness of terminal screws 
and the general condition of the wiring. Also, check to be sure that mounting hardware is tight. Loose connections 
will result in damage for array. Changed SPV Module must be the same kind and type. Do not touch live parts of 
cables and connectors. Use appropriate safety equipment (insulated tools, insulating gloves, etc.), when touching 
them. 
 
Cover the front surface of the SPV Module by an opaque or other material when repairing. The SPV Modules when 
exposed to sunlight generate high voltage and are dangerous. 
 

15. SPECIFICATIONS: 

 

 
See Table1 
 

Notes 

1.

 

Standard Test Condition(STC) of Irradiance of 1000W/m²

AM1.5 Solar Spectrum & 25

ºC 

cell temperature 

2.

 

Nominal Operating Cell Temperature (NOCT): 45±2

ºC

 

3.

 

The tolerance of Voltage and Current within ±10%  

4.

 

Temperature coefficient of Current is 0.05%/

º

K  

5.

 

Temperature coefficient of Voltage is -0.30%/°K 

6.

 

See SPV Module drawing for mounting and grounding holes locations. The drawing for CNPV-xxxxM and  

CNPV-xxxxB(Black module) is identical. 

 
 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 7 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

Table 1: Electrical and Mechanical Specifications. 

Module  

Series 

Model 

Dimensions 

(mm) 

Weight 

(kg) 

Electrical Performance @ STC

 

Max-System 

Voltage (VDC) 

Max-Series 

Fuse (A) 

Recommended Max. 

Module Number 

P

max

(Wp)

V

Pm

(V) 

I

Pm

(A) 

V

OC

(V) 

I

SC

(A) 

In Series

 

In Parallel

7

2

p

cs

 1

25×

125

mm 

 

SPV Modu

le

 

(Mo

n

o-Crys

ta

ll

ine Si

li

co

n ) 

CNPV-160M 

1581×809×35 15 

160  34.5 4.65 43.0 5.15 

IEC6

121

5/

IEC6

173

0:

100

0VD

C

 

10 

17 2 

CNPV-165M 

165  35.2 4.70 43.4 5.20 

17 

CNPV-170M 

170  35.8 4.75 43.8 5.25 

17 

CNPV-175M 

175  36.6 4.80 44.2 5.30 

17 

CNPV-180M 

180  37.2 4.85 44.6 5.35 

17 

CNPV-185M 

185  37.8 4.90 45.0 5.40 

17 

CNPV-190M 

190  37.8 5.05 45.1 5.55 

17 

CNPV-195M 

195  37.9 5.15 45.2 5.60 

17 

CNPV-200M 

200  38.0 5.25 45.3 5.65 

17 

CNPV-205M 

205  38.1 5.38 45.4 5.70 

17 

CNPV-210M 

210  38.2 5.50 45.6 5.80 

17 

7

2

p

cs

 1

25×

125

mm 

 

SPV Modu

le-B

lack

 

(Mo

n

o-Crys

ta

ll

ine Si

li

co

n ) 

CNPV-160MB 

160  34.5 4.65 43.0 5.15 

17 

CNPV-165MB 

165  35.2 4.70 43.4 5.20 

17 

CNPV-170MB 

170  35.8 4.75 43.8 5.25 

17 

CNPV-175MB 

175  36.6 4.80 44.2 5.30 

17 

CNPV-180MB 

180  37.2 4.85 44.6 5.35 

17 

CNPV-185MB 

185  37.8 4.90 45.0 5.40 

17 

CNPV-190MB 

190  37.8 5.05 45.1 5.55 

17 

CNPV-195MB 

195  37.9 5.15 45.2 5.60 

17 

CNPV-200MB 

200  38.0 5.25 45.3 5.65 

17 

CNPV-205MB 

205  38.1 5.38 45.4 5.70 

17 

CNPV-210MB 

210  38.2 5.50 45.6 5.80 

17 

 
 
 
 
 
 
 
 
 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 8 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

Module  

Series 

Model 

Dimensions 

(mm) 

Weight 

(kg) 

Electrical Performance @ STC 

Max-System 

Voltage  

(VDC) 

Max-Series 

Fuse (A) 

Recommended Max. 

Module Number 

P

max

(Wp)

V

Pm

(V) 

I

Pm

(A) 

V

OC

(V) 

I

SC

(A) 

In Series

 

In Parallel

54p

cs 15

15

6mm

 

SP

V

 Modul

(Mon

o-C

rys

ta

lli

ne Sili

co

n)\

 

CNPV-190M-54 

1482×992×35

 

18 

190  26.6 7.15 32.6 7.90 

IEC6

121

5/

IEC6

173

0:

100

0VD

C

 

20 

23 

3

CNPV-195M-54 

195  26.9 7.25 32.8 8.00 

23 

3

CNPV-200M-54 

200  27.0 7.40 33.0 8.10 

23 

3

CNPV-205M-54 

205  27.2 7.55 33.2 8.20 

23 

3

CNPV-210M-54 

210  27.4 7.65 33.4 8.30 

23 

3

CNPV-215M-54 

215  27.6 7.80 33.6 8.40 

23 

3

CNPV-220M-54 

220  27.7 7.95 33.7 8.50 

23 

3

CNPV-225M-54 

225  27.8 8.10 33.8 8.60 

23 

3

CNPV-230M-54 

230  28.0 8.20 33.9 8.70 

23 

3

CNPV-235M-54 

235  28.3 8.30 34.0 8.80 

23 

3

CNPV-240M-54 

240  28.7 8.35 34.1 8.85 

23 

3

60p

cs 15

15

6mm

 

SP

V

 Modul

(Mon

o-C

rys

ta

lli

ne Sili

co

n)

 

CNPV-220M 

1650×992×35 20 

220  29.7 7.40 36.8 8.00 

20 

21 

3

CNPV-225M 

225  30.0 7.50 37.0 8.10 

21 

3

CNPV-230M 

230  30.3 7.60 37.2 8.20 

21 

3

CNPV-235M 

235  30.7 7.65 37.5 8.30 

21 

3

CNPV-240M 

240  30.8 7.80 37.6 8.40 

21 

3

CNPV-245M 

245  30.9 7.93 37.7 8.50 

21 

3

CNPV-250M 

250  31.0 8.05 37.8 8.60 

21

3

CNPV-255M 

255  31.3 8.15 37.9 8.70 

21

3

CNPV-260M 

260  31.5 8.25 38.0 8.80 

21

3

CNPV-265M 

265  31.7 8.35 38.1 8.90 

21

3

72p

cs 15

15

6mm

 

SP

V

 Modul

(Mon

o-C

rys

ta

lli

ne Sili

co

n)

 

CNPV-255M 

1965×992×40 24 

250 

35.9 7.10 43.2 7.70 

20 

17 3 

CNPV-260M 260

 

36.1 7.20 43.4 7.80 

17 3 

CNPV-265M 

265  36.3 7.30 43.6 7.90 

17 3 

CNPV-270M 270

 

36.5 7.40 43.8 8.00 

17 3 

CNPV-275M 

275  36.7 7.50 44.0 8.10 

17 3 

CNPV-280M 280

 

36.9 7.60 44.2 8.20 

17 3 

CNPV-285M 

285  37.0 7.70 44.4 8.30 

17 3 

CNPV-290M 290

 

37.2 7.80 44.6 8.40 

17 3 

CNPV-295M 

295  37.3 7.90 44.8 8.50 

17 3 

CNPV-300M 300

 

37.5 8.00 45.0 8.60 

17 3 

CNPV-305M 

305  37.7 8.10 45.1 8.70 

17 3 

CNPV-310M 310

 

37.9 8.18 45.2 8.80 

17 3 

CNPV-315M 

315  38.1 8.25 45.3 8.90 

17 3 

CNPV-320M 320

 

38.3 8.35 45.4 8.95 

17 3 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 9 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

Module  

Series 

Model 

Dimensions 

(mm) 

Weight 

(kg) 

Electrical Performance @ STC 

Max-System 

Voltage 

(VDC) 

Max-Series 

Fuse (A) 

Recommended Max. 

Module Number 

P

max

(Wp) 

V

Pm

(V) 

I

Pm

(A) 

V

OC

(V) 

I

SC

(A) 

In Series

 

In Parallel

54p

cs 15

15

6mm

 

SP

V

 Modul

e-B

la

ck

 

(Mon

o-C

rys

ta

lli

ne Sili

co

n)\

 

CNPV-190MB-54 

1482×992×35

 

18 

190 26.6 

7.15 

32.6 7.90 

IE

C

612

15/

IE

C

6

1

7

3

0

:1

00

0V

D

C

 

20 

23 3 

CNPV-195MB-54 195 

26.9 

7.25 

32.8 

8.00 

23 3 

CNPV-200MB-54 200 

27.0 

7.40 

33.0 

8.10 

23 3 

CNPV-205MB-54 205 

27.2 

7.55 

33.2 

8.20 

23 3 

CNPV-210MB-54 210 

27.4 

7.65 

33.4 

8.30 

23 3 

CNPV-215MB-54 215 

27.6 

7.80 

33.6 

8.40 

23 3 

CNPV-220MB-54 220 

27.7 

7.95 

33.7 

8.50 

23 3 

CNPV-225MB-54 225 

27.8 

8.10 

33.8 

8.60 

23 3 

CNPV-230MB-54 230 

28.0 

8.20 

33.9 

8.70 

23 3 

CNPV-235MB-54 235 

28.3 

8.30 

34.0 

8.80 

23 3 

CNPV-240MB-54 240 

28.7 

8.35 

34.1 

8.85 

 23 

60p

cs 15

15

6mm

 

SP

V

 Modul

e-B

lac

(Mon

o-C

rys

ta

lli

ne Sili

co

n)

 

CNPV-220MB 

1650×992×35 20 

220 29.7 

7.40 

36.8 8.00 

20 

21 3 

CNPV-225MB 225 

30.0 

7.50 

37.0 

8.10 

21 3 

CNPV-230MB 230 

30.3 

7.60 

37.2 

8.20 

21 3 

CNPV-235MB 235 

30.7 

7.65 

37.5 

8.30 

21 3 

CNPV-240MB 240 

30.8 

7.80 

37.6 

8.40 

21 3 

CNPV-245MB 245 

30.9 

7.93 

37.7 

8.50 

21 3 

CNPV-250MB 250 

31.0 

8.05 

37.8 

8.60 

21 3 

CNPV-255MB 255 

31.3 

8.15 

37.9 

8.70 

21 3 

CNPV-260MB 260 

31.5 

8.25 

38.0 

8.80 

21 3 

CNPV-265MB 265 

31.7 

8.35 

38.1 

8.90 

21 3 

72p

cs 15

15

6mm

 

SP

V

 Modul

e-B

lac

(Mon

o-C

rys

ta

lli

ne Sili

co

n)

 

CNPV-255MB 

1965×992×40 24 

250 

35.9 7.10 43.2 7.70 

20 

17 3 

CNPV-260MB 260

 

36.1 7.20 43.4 7.80 

17 3 

CNPV-265MB 265 

36.3 

7.30 

43.6 

7.90 

17 3 

CNPV-270MB 270

 

36.5 7.40 43.8 8.00 

17 3 

CNPV-275MB 275 

36.7 

7.50 

44.0 

8.10 

17 3 

CNPV-280MB 280

 

36.9 7.60 44.2 8.20 

17 3 

CNPV-285MB 285 

37.0 

7.70 

44.4 

8.30 

17 3 

CNPV-290MB 290

 

37.2 7.80 44.6 8.40 

17 3 

CNPV-295MB 295 

37.3 

7.90 

44.8 

8.50 

17 3 

CNPV-300MB 300

 

37.5 8.00 45.0 8.60 

17 3 

CNPV-305MB 305 

37.7 

8.10 

45.1 

8.70 

17 3 

CNPV-310MB 310

 

37.9 8.18 45.2 8.80 

17 3 

CNPV-315MB 315 

38.1 

8.25 

45.3 

8.90 

17 3 

CNPV-320MB 320

 

38.3 8.35 45.4 8.95 

17 3 

 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 10 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

Module 

Series 

Model 

Dimensions 

(mm) 

Weight 

(kg) 

Electrical Performance @ STC 

Max-System 

Voltage 

(VDC)

 

Max-Series 

Fuse (A) 

Recommended Max. 

Module Number 

P

max

(Wp)

V

Pm

(V) 

I

Pm

(A) 

V

OC

(V) 

I

SC

(A) 

In Series

In Parallel

5

4

p

cs

 1

56×

156

mm 

SPV Modu

le

 

(P

ol

y-

Cr

yst

a

ll

ine S

il

ico

n)

 

CNPV-190P-54 

1482×992×35

 

18 

190  26.2 7.25 32.7 7.95 

IEC6

121

5/

IEC6

173

0:

100

0VD

C

  

20 

23 3 

CNPV-195P-54 

195  26.5 7.35 32.9 8.05 

23 3 

CNPV-200P-54 200 

26.7 

7.5 

33.1 

8.15 

23 3 

CNPV-205P-54 

205  26.9 7.63 33.3 8.25 

23 3 

CNPV-210P-54 

210  27.1 7.75 33.5 8.35 

23 3 

CNPV-215P-54 

215  27.4 7.85 33.7 8.40 

23 3 

CNPV-220P-54 

220  27.7 7.95 33.9 8.45 

23 3 

CNPV-225P-54 

225  28.1 8.00 34.1 8.50 

23 3 

CNPV-230P-54 

230  28.4 8.10 34.3 8.55 

23 3 

CNPV-235P-54 235 

28.6 

8.20 

34.5 

 

8.65 

23 3 

6

0

p

cs

 1

56×

156

mm 

SPV Modu

le

 

(P

ol

y-

Cr

yst

a

ll

ine S

il

ico

n)

 

CNPV-210P 

1650×992×35 20 

210  29.2 7.20 36.4 7.80 

20 

21 3 

CNPV-215P 

215  29.5 7.30 36.6 7.90 

21 3 

CNPV-220P 

220  29.8 7.40 36.8 8.00 

21 3 

CNPV-225P 

225  30.1 7.50 37.0 8.10 

21 3 

CNPV-230P 

230  30.3 7.60 37.2 8.20 

21 3 

CNPV-235P 

235  30.5 7.70 37.3 8.30 

21 3 

CNPV-240P 

240  30.8 7.80 37.4 8.40 

21 3 

CNPV-245P 

245  31.0 7.90 37.5 8.50 

21 3 

CNPV-250P 

250  31.2 8.00 37.6 8.55 

21 3 

CNPV-255P 

255  31.3 8.15 37.7 8.60 

21 3 

CNPV-260P 

260  31.5 8.25 37.8 8.65 

21 3 

CNPV-265P 

265  31.7 8.35 37.9 8.70 

21 3 

7

2

p

cs15

156

mm 

SPV Modu

le

 

(P

ol

y-

Cr

yst

a

ll

ine S

il

ico

n)

 

CNPV-250P 

1965×992×40 24 

250

 

35.8 7.00 43.4 7.60 

20

 

17 3 

CNPV-255P 

255  36.0 7.10 43.6 7.70 

17 3 

CNPV-260P 260

 

36.2 7.20 43.8 7.80 

17 3 

CNPV-265P 

265  36.4 7.30 44.0 7.90 

17 3 

CNPV-270P 270

 

36.6 7.40 44.2 8.00 

17 3 

CNPV-275P 

275  36.7 7.50 44.4 8.10 

17 3 

CNPV-280P 280

 

36.9 7.60 44.6 8.20 

17 3 

CNPV-285P 

285  37.0 7.70 44.8 8.30 

17 3 

CNPV-290P 290

 

37.2 7.80 45.0 8.40 

17 3 

CNPV-295P 

295  37.4 7.90 45.1 8.45 

17 3 

CNPV-300P 

300  37.6 8.00 45.2 8.50 

17 3 

CNPV-305P 

305  37.7 8.10 45.3 8.55 

17 3 

CNPV-310P 

310  38.0 8.15 45.4 8.60 

17 3 

CNPV-315P 

315  38.2 8.25 45.5 8.65 

17 3 

 
 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 11 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

Module 

Series 

Model 

Dimensions 

(mm) 

Weight 

(kg) 

Electrical Performance @ STC 

Max-System 

Voltage 

(VDC) 

Max-Series 

Fuse (A) 

Recommended Max. 

Module Number 

P

max

(Wp)

V

Pm

(V) 

I

Pm

(A) 

V

OC

(V) 

I

SC

(A) 

In Series

 

In Parallel

5

4

p

cs

 1

56×

156

mm 

SPV Modu

le-B

lack

 

(P

ol

y-

Cr

yst

a

ll

ine S

il

ico

n)

 

CNPV-190PB-54 

1482×992×35

 

18 

190  26.2 7.25 32.7 7.95 

IEC6

121

5/

IEC6

173

0:

100

0VD

C

  

20 

23 3 

CNPV-195PB-54 

195  26.5 7.35 32.9 8.05 

23 3 

CNPV-200PB-54 

200  26.7 7.50 33.1 8.15 

23 3 

CNPV-205PB-54 

205  26.9 7.63 33.3 8.25 

23 3 

CNPV-210PB-54 

210  27.1 7.75 33.5 8.35 

23 3 

CNPV-215PB-54 

215  27.4 7.85 33.7 8.40 

23 3 

CNPV-220PB-54 

220  27.7 7.95 33.9 8.45 

23 3 

CNPV-225PB-54 

225  28.1 8.00 34.1 8.50 

23 3 

CNPV-230PB-54 

230  28.4 8.10 34.3 8.55 

23 3 

CNPV-235PB-54 

235  28.6 8.20 34.5  

8.65 

23 3 

6

0

p

cs

 1

56×

156

mm 

SPV Modu

le-B

lack

 

(P

ol

y-

Cr

yst

a

ll

ine S

il

ico

n)

 

CNPV-210PB 

1650×992×35 20 

210  29.2 7.20 36.4 7.80 

20 

21 3 

CNPV-215PB 

215  29.5 7.30 36.6 7.90 

21 3 

CNPV-220PB 

220  29.8 7.40 36.8 8.00 

21 3 

CNPV-225PB 

225  30.1 7.50 37.0 8.10 

21 3 

CNPV-230PB 

230  30.3 7.60 37.2 8.20 

21 3 

CNPV-235PB 

235  30.5 7.70 37.3 8.30 

21 3 

CNPV-240PB 

240  30.8 7.80 37.4 8.40 

21 3 

CNPV-245PB 

245  31.0 7.90 37.5 8.50 

21 3 

CNPV-250PB 

250  31.2 8.00 37.6 8.55 

21 3 

CNPV-255PB 

255  31.3 8.15 37.7 8.60 

21 3 

CNPV-260PB 

260  31.5 8.25 37.8 8.65 

21 3 

CNPV-265PB 

265  31.7 8.35 37.9 8.70 

21 3 

7

2

p

cs15

156

mm 

SPV Modu

le-B

lack

 

(P

ol

y-

Cr

yst

a

ll

ine S

il

ico

n)

 

CNPV-250PB 

1965×992×40 24 

250

 

35.8 7.00 43.4 7.60 

20

 

17 3 

CNPV-255PB 

255  36.0 7.10 43.6 7.70 

17 3 

CNPV-260PB 260

 

36.2 7.20 43.8 7.80 

17 3 

CNPV-265PB 

265  36.4 7.30 44.0 7.90 

17 3 

CNPV-270PB 270

 

36.6 7.40 44.2 8.00 

17 3 

CNPV-275PB 

275  36.7 7.50 44.4 8.10 

17 3 

CNPV-280PB 280

 

36.9 7.60 44.6 8.20 

17 3 

CNPV-285PB 

285  37.0 7.70 44.8 8.30 

17 3 

CNPV-290PB 290

 

37.2 7.80 45.0 8.40 

17 3 

CNPV-295PB 

295  37.4 7.90 45.1 8.45 

17 3 

CNPV-300PB 

300  37.6 8.00 45.2 8.50 

17 3 

CNPV-305PB 

305  37.7 8.10 45.3 8.55 

17 3 

CNPV-310PB 

310  38.0 8.15 45.4 8.60 

17 3 

CNPV-315PB 

315  38.2 8.25 45.5 8.65 

17 3 

 
 
 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 12 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

4-

Φ

9

×

12

 

INSTALLING  HOLE

1581±2

948

7

5

4

4-

Φ

12 DRAIN HOLE

2-

Φ

GROUNDING HOLE

GROUNDING MARKING

8

09±

2

4-

Φ

4

×

6

 

DRAIN HOLE

4-

Φ

4

×

4

 

DRAIN HOLE

316.5

316.5

Section A-A

magnified

8

1.

9

35

35

900(Typical)

+

1.8

1.5

 

Drawing 1 Back View of 6×12-125mm- 72cell SPV Module 

 

1 20

~

1 4

 

Module Length

1 20

~

1 4

 Module

 Length

809

158

1

809

Module

Middle Clip

End Clip

Support Rack

809

158

1

809

Module

Support Rack

M8 Screw

Mounting Drawing (with clamping clips)

Mounting Drawing (with screws)

 

 

Drawing 2 Mounting Drawing for 6×12-125×125mm 72cell SPV Module (with screws and clamping clips on long frames) 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 13 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

35

1.8

1.9

11

1.5

35

1000VD

C IP6

5

+

TUV  C

E

1202

4-Φ12 DRAIN HOLE

8-Φ9×12 INSTALLING HOLE

2-Φ4 GROUNDING HOLE

992±

2

702(For normal installation)

1200(Typical)

GROUNDING MARKING

942

4-Φ4.5×4 DRAIN HOLE

140

140

1482±2

390

390

(For High wind and snow load, these two

installation holes should also be used.)

Section A-A

(magnified)

 

Drawing 3 Back View of 6

×

9-156

×

156mm 54cell SPV Module 

 

1 20

~

1 4

 Modu

le Len

gth

1 20

~

1 4

 Mo

dule L

ength

992

148

2

992

Moudle

Middle Clip

End Clip

Support Rack

Mounting Drawing (with clamping clips)

70

2

992

148

2

992

Moudle

Support Rack

Mounting Drawing (with screws)

Screw M8

120

2

25

0

25

0

14

0

14

0

 

Drawing 4 Mounting Drawing for 6×9-156×156mm 54cell SPV Module (with screws and clamping clips on long frames) 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 14 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

1.9

+

35

35

1.8

1.5

990

4-Φ12 DRAIN HOLE

8-Φ9×12 INSTALLING HOLE

2-Φ4 GROUNDING HOLE

992±2

Section A-A

(magnified)

94

1

4-Φ4.5×4 DRAIN HOLE

330

330

1200(Typical)

1650±2

11

GROUNDING MARKING

 

Drawing 5 Back View of 6

×

10-156

×

156mm 60cell SPV Module 

 

1 20

~

1 4

 M

odul

e L

eng

t

h

1 20

~

1 4

 

M

odu

l

e L

e

ng

th

992

16

50

992

Moudle

Middle Clip

End Clip

Support Rack

Mounting Drawing (with clamping clips)

33

0

99

0

33

0

992

16

50

992

Moudle

Support Rack

Mounting Drawing (with screws)

Screw M8

 

Drawing 6 Mounting Drawing for 6×10-156×156mm 60cell SPV Module

 

(with screws and clamping clips on long frames)

 

 


background image

 

TECHNICAL SPECIFICATION 

TITLE:

  

 

IEC INSTALLATION INSTRUCTION 
MANUAL FOR THE CRYSTALLINE 
SOLAR PHOTOVOLTAIC MODULE

 

SPEC. NO.: 

CNPV-PS-M-S0010-IEC 

REVISION: J 

EFFECTIVE DATE: 

July 2012 

AUTHOR(S):

  Bypina Veerraju Chaudary, Yang Xiaowu 

Page 15 of 15

 

 

CNPV Dongying Solar Power Company Limited,  

Shengli Industry Park, Dongying City, Shandong Province 257000, PRC 

http//www.cnpv-power.com    E-mail: 

marketing@cnpv-power.com

  Tel: +86-546-7795555, Fax: +86-546-7795777 

 

+

1965±2

1177

94

1

4-R2.25×4 DRAIN HOLE

2-Φ4 GROUNDING HOLES

4-

?

9×12 INSTALLING  HOLE

GROUNDING MARKING

4-R6 DRAIN HOLE

Section A-A

magnified

11

394

394

35

40

2.0

99

2

1200(Typical)

1.8

1.5

 

Drawing 7 Back View of 6

×

12-156

×

156mm 72cell SPV Module 

 

1 20

~

1 4

 M

odu

le L

eng

th

1 20

~

1 4

 Mod

ule 

Len

gth

992

19

65

992

Module

Middle Clip

End Clip

Support Rack

Mounting Drawing (with clamping clips)

39

4

11

77

394

992

19

65

992

Module

Support Rack

Mounting Drawing (with screws)

Screw M8

 

 

Drawing 8 Mounting Drawing for 6×12-156×56mm 72cell SPV Module

 

(with screws and clamping clips on long frames)