ST-PMC1 single-axis motion controller operating manual

2
/
17
Ⅰ
.Features .............................................................................................................................. 3
Ⅱ
.Front panel diagram............................................................................................................ 3
Ⅲ
. Back panel diagram and signal descriptions ....................................................................... 4
Ⅳ
. The controller connection diagram: ................................................................................... 5
Ⅴ
. The operation flow chart ................................................................................................... 5
Ⅵ
.
parameter setting: ............................................................................................................ 7
Ⅶ
.
program editing and Detailed instructions: ...................................................................... 8
Ⅷ
.The manual operation mode: ........................................................................................... 10
Ⅸ
.
Automatic operation mode ............................................................................................. 10
Ⅹ
. Installation dimensions .................................................................................................... 11
Ⅺ
. Editing and application examples: ................................................................................... 12
Ⅻ
. directive search form ....................................................................................................... 14
ⅩⅢ
. Parameters search form ............................................................................................... 15
ⅩⅣ
. Button search form ...................................................................................................... 16

3
/
17
Ⅰ
.Features
•
Number of controlled axis: Single axis; can achieve a variety of complex operation: positioning
control and non-positioning control;
•
The maximum output frequency: 40KHZ;
•
Output frequency resolution: 1Hz;
•
Programmable maximum number of rows: 99;
•
Signal input: 6 (optical isolation);
•
Signal output: 3 (optical isolation);
•
A continuous displacement range: -7,999,999 ~ 7,999,999;
•
Operating state: Autorun mode, manual operation, the program edit mode, parameter setting
status;
•
Lifting speed curve: 2 (optimization);
•
Display digits: 8 digital display, manual / automatic status display, run / stop status display, the
number of steps / counts / procedures display, edit the program, parameter display, input /
output status display, pulse and direction display ;
•
Autorun feature: You can edit, you can control the start and stop automatically run through the
panel buttons and processing and other operations at the terminal level;
•
Manual operation functions: position adjustments (manual jog speed and jog the number of
steps can be set);
•
Parameter setting function: Starting frequency, acceleration and deceleration curve, reverse
clearance, manually run length, manual speed, back to zero speed and interrupt jump the line
all can be set;
•
Program editing functions: You can insert, delete, modify the program. The controller can
identify the error Instruction;
•
Return to Zero features: It can be from the positive and negative directions, automatic return
to zero
•
The number of programming instructions: 14 instruction;
•
Outside the operating functions: interrupt operation through parameter setting and switch
connected to the terminals A and B;
•
Power supply:DC24V;
Ⅱ
.Front panel diagram
1. 8 digital led Segment displays;
2. 6 input status indicator;
3. 3 output status indicator;
4. CP pulse signal indicator;
5. CW direction signal indicator;
6 Keys: 10 keys total, and most of the composite keys,
they represent different functions in different states,
in
the following description, we just take one of the
functions represents a key.
Figure I: operation panel

4
/
17
Ⅲ
. Back panel diagram and signal descriptions
1.
CP, CW, OPTO
for stepper motor drive signal ;
CP:
pulse signal
CW:
direction signal
0PT0:
Public male end before the two signals
2.
RUN:
Start running the program, The same function as
“
Run
”
of the operation panel;
3.
STOP:
Pause program is run automatically, The same
function as
“
Pause
”
of the operation panel, After starting
again, the program continues to run;
4.
A:
A operation
B:
B operation
“
A operation
”
and
“
B operation
”
this is a major feature of the controller:
For stepper motors, we generally quantitative positioning control, such as controlling the
displacement of the motor must be running at a constant speed
,
In this way it is easy to solve,
just put the amount and speed of displacement of the programming can be.
But there are quite a lot of control is not positioning in advance, such as controlling the
stepper motor in one direction from the starting point to start running until he hit a switch after
stroke stop, then reverse direction back to the starting point. Another example requires the
stepper motor running back and forth between the two limit switch several times, and so on. In
these operations, we do not know in advance the specific value of the stepper motor
displacement, and how they should be programmed it? The controller uses: to interrupt the
operation, which we call "A Operation" and "B operation
”
,for example," A operations", workers
workflow is: when the program is running. If "A operation" signal input, motor decelerates to
stop, Program interruption, the controller remembers interrupted coordinate values, the program
jumps to the "A operation" entry address specified programs run the program;
5.
IN1
and
IN2
Switching signal input terminal
6.
OUT1
,
OUT2
and
OUT3
Switching signal output terminal,
7.
COM +
,
COM-
: the power supply of external input and output devices, this power supply is
DC24V,
COM +
is the positive terminal of the power supply,
COM-
negative side;
8.
+24V:
The positive power supply ,
GND:
Negative power supply;
The signal
RUN
,
STOP
,
A
,
B
,
IN1
,
IN2
called the input signal, they have the same input interface
circuit.
OUT1
,
OUT2
,
0UT3
called the output signal. They have the same output interface circuit.
Both input and output optical isolation circuit to ensure that the internal and external controllers
do not interfere with each other;
The state of the input signal and output signal, corresponding indicator on the panel. For input,
input low (switch is closed) Indicator light; For output signal, the output 0 is low, the light is off,
the opposite will light.
Figure II: Back panel diagram

5
/
17
Figure
Ⅲ
switch input circuit
When the switch is turned on, Input level is low, on the front panel indicator lights, the program
is defined as 0.
Figure
Ⅳ
switch output circuit
Output of low output, load conduction, front panel indicator lights, the program is defined as 1.
Ⅳ
. The controller connection diagram:
Figure
Ⅴ
controller connection diagram
Ⅴ
. The operation flow chart
Controller always operate in one of four states: automatic mode, manual mode, the program edit
mode, parameter setting state. Power or press the
Reset
, Controller to be run in automatic mode,
the cursor coordinates 0, then you can start the program to run automatically or switch to
manual mode, program editing state and parameter setting status can only switch in manual
mode. Editing completed or parameter setting procedure is completed, press the
Quit
to return
to manual mode (the program will be saved) ,in manual mode, if you switch to program edit
mode, simply press the
Edit
button, if you switch to the parameter setting state, press
Set
more
than 2 seconds.
(Note: The above mentioned
Edit, Set, Quit
, is the same button, we introduce a feature, the
button's name only choose one, the same below)
OUT1-3
CP CW OPTO
Input devices: External
Start button
、
Limit switch
、
Photoelectric switch
Output signal control relay
、
indicator light
Power supply
:
DC24V
ST-PMC1
Stepper Motor Controller
stepper motor drive
r
stepper motor

6
/
17
Press
Enter
enter data
editing
00400
Press
RUN
Automatically run the program
and displays the current status:
the coordinate values, count or
program lines
Press
STOP
Program pauses
Press
Home
Motor back to zero
in accordance with
a pre-set speed
A
operation or
B
operation
Motor interrupt the current operation,
for deceleration stop, remember the
current coordinate value, then the
program pointer operations into A or B
operation specified by the entrance to
the program.
Power on or
Rest
A:
After power on or
Rest,
Coordinates
to reset, As the coordinate zero, In
standby mode;
B:
Memory is not cleared, the data
transferred
to
the
last
stored
memory(Please refer to the "Program
Edit")
Auto Mode
L 000000
This step is step number
display, You can switch
the display mode for the
count or program
Motor run in accordance
with the appropriate amount
of displacement in the
direction and speed of
preset
Press
<
or
>
Program edit state
00 speed
Press
﹥
Move the cursor
00 speed
press
∧∨
edit number
10400
Press
Enter
Go to the next
line editing
01 end
Press
Insert
the
new
program line
01 PRUSE
Until all programs are modified
or completed entry
Press
Edit/Quit
more than 2 seconds
Press
Enter
edit
parameter
Jf
00400
Press
Enter
save parameter
Return to previous menu
press
∧ ∨
to set another
parameter
CP ------
Parameter setting status
Jf
------
Press
﹤
or
﹥
Select the
number
Jf
00400
press
∧ ∨
edit
number
Jf
01400
Press
Edit/Quit
more than 2 seconds
Press
Edit/Quit
Manual mode
-11-
000000
Press
Auto/Jog
Press
STOP
Pause manually run
Press
RUN
Press Home
Motor back to zero in accordance
with a pre-set speed

7
/
17
Ⅵ
.
parameter setting:
Out of the way of parameter setting status is: In manual mode, press
Edit
and hold the
button for 2 seconds or more , enter the parameter setting state. After parameter setting is
complete, press the
Quit
button to return to manual mode (parameters will be saved).
Parameters displayed in two rows, the first row shows the name of the parameter, the second
line shows the parameter data.
Parameter changes: After entering the parameter setting state, the first line of the display:
jf------
.
Former two parameter name in flashing: press
∧∨
, Will display the next or previous
parameter name, press Enter, Will enter the edit state (next row) parameter data, when the first
bit of data flashing display, press
∧∨
, data will be changed. press
<>
, Will move to the next
one to be modified, after the data modification, press
Enter
Save changes, press
Cancel
discard
changes and exit.
In short, the set parameters through
∧∨<>
"Enter", "Cancel"
six buttons to complete the six:
by moving left and right keys to move the cursor to the appropriate position, then the digital
display will beat, and then through the upper and lower keys to change the value: use the Enter
key to enter the data modification status, after the data modification is completed, confirm with
the Enter key to exit or discard the changes with Cancel button. Please refer to the "List of
operational processes."
N
O
Name
parameter
display form
Data range
(unit)
Parameter Description
1
Off frequency
JF- - - - - -
JF X X X X X X
400-3999
(Hz)
If the set value is less than 400Hz, the system will alarm;
Users can set different off frequencies according to their actual situation
2
Rising
and
falling curve
rS- - - - - -
rS X
L
、
H
(stripe
)
The controller has two internal optimization rising and falling speed curve,L is
a slow curve; H to a faster curve, to select a different rate of rise and fall curve
based on the actual load situation.
3
Backlash
compensation
CC- - - - - -
CC XXXX
0-9999
(pulses
number
)
Mainly used to
c
ompensate the rotation mechanism(such as a
screw, gear, etc.) The amount of displacement caused by the backlash
error
compensation is not displayed on the controller.
4
Manual
increment
HL
- - - - - -
HL X X X X
X X
1-999999
(pulses
number
)
In manual mode, the manual operation is a displacement of the
stepper motor; If the set value is equal to 0, the system will alarm.
5
Manual speed
HF- - - - - -
HF X X X X X
X
1-39999
(Hz)
In manual mode, manual operation is running speed stepper motor; If the set
value is equal to 0, the system will alarm.
6
Back
to
zero
speed
bF- - - - - -
bF X X X X X X
1-39999
(Hz)
When zeroing operation, stepper motor speed; If the set value is equal to 0, the
system will alarm
7
A
Operation"
entry address
Na- - - - - -
NA XX
00-99
(Line number
)
When the program is running, if the "A Operation" signal input port, the motor
for the deceleration stop the program at this interruption, the application
remembers interrupted coordinate values, the program will jump to this line
number specified
by the program at run the program.
8
B
Operation"
entry address
nB- - - - - -
nB XX
00-99
(Line number
)
When the program is running, such as Gao "B Operation" end signal input, the
motor will slow down to stop the program at this interruption, the application
remembers interrupted coordinate values, the program will jump to this line
number specified by the program run the program.
9
Pulse mode
CP- - - - - -
CP X
0
、
1
CP = O represented as a single pulse output, CP-side rear panel output step
pulse, CW-ended output direction level; CP = I expressed as a single pulse
output, CP-ended output on the rear panel forward step pulse, CW-ended
output inversion step pulse.

8
/
17
Ⅶ
.
program editing and Detailed instructions:
Out of the way the program editor is: In manual mode, press the
"Edit"
button. To enter the
program edit state. After the program editing is complete, press the
"Quit"
button back to
manual mode (parameters are automatically saved)
Program area of the controller can edit up to 99 instructions, each instruction in the program
there is a line number, line number for automatic numbering starts from OO arranged in order,
you can insert or delete a row in the program, but the line number will be reassigned.
The program format is: Each program is divided into two-line display (except no parameter
program), the first line displays the line number and command name, and the second line shows
the instruction data. The last instruction of the program is fixed to "END",
In short, modify the program by
"
∧
”
“
V" "<
”
“
>"
“
insert
”
“
delete
”
"Enter" "Cancel"
eight
buttons to complete: by moving left and right keys to move the cursor to the appropriate position,
then beat the digital display will then change the value via the arrow keys: Use the Enter key
enter data modification status, after the data modification is completed, confirm with the Enter
key to exit or discard the changes with Cancel button. Please refer to the operation flow chart.
Program editing instructions
P rogram edit
Operate procedure
Enter edit mode
In manual mode, press the
“
Edit
”
button
Exit edit mode
Under the state program editing line numbers flashing state, press the
“
Quit
”
key
to return to the manual mode, the program will automatically save
Clear the
program
When the program editing line numbers flashing, press and hold "
Clear
"button
for 2 seconds or more, until the first 00-line instructions for END time.
entry
a
new
program
First clear the program area, then only one program, 00 row END command,
and then press the "
Insert
" button, Directive 00 line program into a PAUSE, and
flashing display; press the "
∧
" "
∨
"command name was changed; until you find
the desired command, and then press the"
Enter
"to enter the command data
area (no parameters for command, enter the program after the completion of this
section entry), press
∧∨<>
to modify, After the changes are complete press
the "Enter" button, enter this line program is completed, you can see the next line
becomes END command, then press the "
Insert
" key entry program with the
same way until all program entry is completed.
Special Note:
When you enter a new program obviously is the correct procedure,
but the alarm controller error, this happens in a branch instruction: like
JUMP
instruction,
J-BIT
directive,
J -CNT
if these three directive Skip the line number
where this instruction is greater than the current line number, due to the jump
target has not been entered, the controller will misjudge entry line number is
wrong, in order to avoid this, we require a new program at the time of entry, these
three instructions Jump in the line number that appears temporarily replaced with
00, after the program is completed entry, Change the line number 00 to the
correct line number.
Modify program
Reference above, " entry a new program " approach, modify the current program
Insert program
When the program edit state line number is flashing, press the "
Insert
" button to
insert a new row above the current program, the program modification operations.
Delete program
When the flashing line number in the program editor, press the "
Delete
" key, the
program is deleted, the following program automatically move up.

9
/
17
Detailed instructions for directive(HH- line number, XXXXXX-- data)
Browse
program
When the program editor line numbers flashing, press "
∧
" "
∨
", you can browse
command name of each line of the program, but you want a quick look at the
instruction parameters, how to do it, you just click the "
<
" key, the parameters will
flashing a second.
No.
Directive
Name
Directive to display
the form
Description
1
Pause
directive
HH
一
PAUSE
No arguments
Program pause and wait for the panel start button or terminal
operation start signal or A, B operation signal.
2
Displacement
directive
HH_G-LEN
±
XXXXXX
When executing this directive, the controller will be conferred the
latest SPEED assignment, displacement volume parameter
settings specified in this directive set off frequency, acceleration
and deceleration curve, backlash compensation, and control the
motor running; If this instruction is not SPEED assignment, place
start frequency for running speed; Parameters of the first one is
the sign bit, 0 for positive displacement, - for negative
displacement; Parameters: -7999999 - +7999999 Unit: pulse
number if the argument is 0, it will alarm
3
Speed
assignment
directive
HH_SPEED
XXXXX
All run this program following this directive will set the speed to
run until the next occurrence rate assignment directive;
Range of parameters: I a 39,999 unit: pulses / sec (Hz)
If the parameter is 0, it will alarm.
4
Delay
directive
HH_DELAY
XXXXXXX
Delay time; parameters: I a 7,999,999 Unit: milliseconds; such as
Gao parameter set to 0, the system will alarm.
5
Uncondition
jump directive
HH
一
JUMP
XX
Unconditional jump directive, parameter XX represents the
program to jump to the line number; XX line numbers when more
than END directive line numbers, alert prompts.
6
Cycle
directive
HH
一
LOOP
XXXXXXX
From the current line to the specified line through the loop; first
two digits of the line number (requires less than the current line),
after five of cycles (0 defined as infinite). When the line number
than the current line number, the system will alarm.
7
Move to
a position
HH_G0T0
±
xxxxxxx
Run to the specified location, in practical applications, this
general location as a reference point in the system; first
parameter is the sign bit, a positive number indicates that the
zero point lies in the positive direction, negative, negative
direction indicates that this point is zero;
If the parameter value = 0, which returns zero;
Parameter Range: -7,999,999 + 7999999 Unit: pulse number
8
Output
directive
HH
一
OUT
XXXX
The first three parameters from left to right correspond to the
output terminals 0UT1-0UT3; while the corresponding front panel
LEDs 1-3 every three output has three options: O, I, N:.
0- corresponding output terminal is high, the load is not
conducting, panel lights off.
I- corresponding output terminal is low, the load is turned on, the
panel lights.
N- Maintain previous working state
The last one parameter, control buzzer
When 0- execute this command, a short buzzer sound; (Note: in
order to execute the program after the end of the next sound)
When 1- execute this command, a long buzzer sound; Note: in
order to execute the program after the end of the next sound)
When N- execute this command, the buzzer does not sound.

10
/
17
Ⅷ
.The manual operation mode:
In automatic mode, press
"Auto / Manual"
will enter the manual mode, the former two-bit
digital tube will be displayed as to
,
indicate that the manual states. Press
“
<
”
or
“
>
”
, the
motor will run manually in different directions, Speed and displacement of the running, as
determined by HF and HL of the parameters set, please refer to "Figure 6: Controller operation
flow chart
“
.
Ⅸ
.
Automatic operation mode
Power on the controller or press the reset button, automatically makes the coordinates cleared,
and redefines this coordinates of the new coordinate zero, reads the counter value, the controller
is in standby mode, press
"Run "
button or enter a start signal from the terminal, the controller
from the first row 00 program starts to run until the run to the last program END, then
automatically run ended, the controller returns to standby mode. Please refer to "Figure 6:
Controller Operation Flowchart"
In automatic mode, there are three kinds of different sub-states:
1. Standby mode: indicates that the controller is ready to run the program, simply press the
Run
button or the input signal to start the program
,
after the run, also in this state.
9
Positioning
Jump
HH_J-BIT
XX XX
The first two jumps for the line number indicating the position, the
fifth bit input port IN1-IN2 is one of them; eighth to jump condition
(0 or 1); measured when the input port is set Jump to the
directive line when the state number, otherwise, the order of
execution. END command line number line number is exceeded,
will alarm.
10
Counting
Jump
HH_J-CNT
XX XXXXX
counter directive, The first two digits is the line number, specify
the location of the jump program; after five of the set value. When
the counter counts to or greater than the set value, then jump to
a specific line number, otherwise the order of execution. END
command line number line number is exceeded, it will clarm.
11
Variable
displacement
HH_60-AB
±
x
This directive is the displacement instruction, run mode like
HH-G-LEN
±
X XX XXX X , different is running displacement can't
know ahead of time, this is a variable displacement, generated
by the interrupt operation, the controller receives an interrupt
signal, the motor slows down to stop, at this point coordinates, is
the variable
12
Counter
is
incremented 1
directive
HH
一
CNT-1
No arguments
This directive counter instruction, the internal controller has a
counter unit with a capacity of 999,999, the counter value can
display real-time status display counter; counter values are not
automatically saved when power is off, unless you manually click
counter storage key
“
﹥
”
. After power on, it will automatically be
transferred to the stored value of the latest counter, this counter
incremented1 by this directive.
13
counter clear
directive
HH_CNT-0
No arguments
This instruction to counter reset; This directive can also be
invoked with the button (in automatic mode),press:
“
V
”
to clear
counter.
14
Coordinate
cleared
HH-CLR
Execute this directive, the current coordinates and display are
cleared, The controller redefines this coordinates of the new
coordinate zero ..
15
End
of directive
HH
一
END
No arguments
End the program , When the program is running this directive,
the controller automatically run ends
The directive, can
’
t be edited, and always at the last line of the
program.

11
/
17
2. Autorun program status: indicating that the controller is running the program.
3. The automatic operation stop state: the controller is running the program is the stop button or
input from the terminal stop signal interruption .Run the program will wait to be started again at
the breakpoint.
In autorun program status
:
there are three different ways :( display by pressing the same key
“
step
”
“
count
”
“
∧
”
to shift)
1. Step number display: controller displays the current coordinate values, unit: pulse number:
2. Count display mode: The controller displays the counter value of the counter unit:a single
current number:
3. Program display: controller displays the current program line and in which the program name.
To be able to distinguish between a good three sub-state automaton states and three display
mode on the display, we use a different display mode to display the difference between the first
two :( see table below)
Ⅹ
. Installation dimensions
The controller uses the embedded instrument shell, small size and light weight (500g), recite the
front panel is 71mm*71mm, length of 105mm, specific dimensions shown below:
Display
Corresponding state
Description
Step
number
(coordinates)
display,
To be run in automatic mode
When the actual coordinate values
displayed over six digits (including the
sign bit), only Show the last six
digits
Counter display,
To be run in automatic mode
When the value of the counter more
than six digits, only
Show the last six digits
Program display,
To be run in automatic mode
The last six digits of the display, in
order to express simple current
program with six-figure line, we used
3,4-bit display the current line
number: Bit 5 Empty: The first
instruction is referred to as 6,7,8-bit
display (refer to "
directive search
form
" directive abbreviation)
Steps
number,
counting,
program three display mode
automatic operation
When the three display mode in the
automatic operation display the first
two are the same, scilicet
means the program under way.
Steps
number,
counting,
program three display mode
Automatic stop state
When the current two digits flashing,
it means that the program is
interrupted,
the
breakpoint
is
waiting.

12
/
17
Figure
Ⅶ:
installation dimensions
Ⅺ
. Editing and application examples:
Example 1
:
Parameter requirements: off frequency 2. 5KHz, lifting speed faster, backlash compensation is 0;
Operational requirements: to speed 2. 9KHz run 98,765 steps, then run 8765 steps in the
opposite direction at a speed of 15KHz, stop.
Parameter list:( Enter the parameter list parameter setting status changes) JF = 02500, rS = H, CC
= OOOO.
Program Listing:00 SPEED 02900 ; assignment to run below the speed 2. 9KHz
01 G-LEN 0009876 ; motor running 98,765 steps forward
02 SPEED 15000 ; assignment to run below the speed of 15KHz
03 G-LEN -0008765 ; 8765 step motor is running in the opposite direction
04 END ; End of program;
Example 2
:
Parameter requirements:
When the starting frequency is 2.5KHz,the Lifting speed is Slow and
Backlash compensation is 12;
Operating Requirements:
When running,Require for that after the buzzer tweet for a short
time,run 1234567 step as the speed of 39KHZ, Making three outputs for 101 state, after delaying
the time for 55.9 seconds, let the last two outputs state is 11, Program pause here, Until run
again, let the motor return to the starting point at the same rate on the other side that is
the 888 step positions, After reaching a predetermined position, the buzzer will tweet for a long
time, then the program ends!
Parameter List:
(Enter the parameter setting mode to modify) JF = 02500, rS = L, CC = 0012.

13
/
17
Program Listing :
( enter the program edit state)
00 OUT nnn0 ; Let the buzzer tweet for a short time
01 SPEED 39000 ; Assign the speed as 39KHz
02 G-LEN 01234567 ; Motor runs forward 1234567 step
03 OUT 101n ; Making three outputs for 101 state
04 DELAY 0055900 ; delaying the time for 55.9 seconds
05 OUT n11n ; let the last two outputs state is 11
06 PAUSE ; Program pause here
07 GOTO -0000888 ; let the motor return to the starting point on the other side that is the 888
step positions
08 OUT nnn1 ; Let the buzzer tweet for a long time
09 END ; the program ends!
Example 3
:
Operating Requirements:
(Ignore the parameter setting) One object, from zero that run for
2.9KHz speed to run forward 100 step (this point as the reference point of the object); After the
reference point stopped, the output is 010; Detect the input, if INI = 0, the motor will return to
zero at the same speed. If INI
≠
0, the motor will run forward 10,000 steps at a speed of 15KHz
and let buzzer alarm for a short time; And then will return to the reference point at a speed of
35KHz. If INI = 0, then return to zero, Otherwise, continue to follow the way of the first to
run.After return to zero ,The buzzer will alarm for a long time.
Program Listing :
( enter the program edit state)
00 SPEED 02900
;
Assign the speed as 2.9KHz
01 G-LEN 00000100
;
Motor runs forward 100 steps
02 OUT 010n
;
Let output state is 010
03 J-BIT 11 1 0 ;
04 SPEED 15000 ; IN1
≠
0, then assign the new speed as 15KHz
05 G-LEN 00010000 ; Motor runs forward 10000 steps again
06 OUT nnn0 ; Let buzzer alarm for a short time
07 SPEED 35000 ; Assign the speed as 35KHz, For setting the speed of returning to the
reference point
08 GOTO 00000100 ; Motor return to the reference point at the speed of 15KHz
09 LOOP 03 00000 ; Motor will run for an infinite loop ,until IN1 = 0, it will return to zero
10 SPEED 02900 ; Assign the speed of returning to zero as 2.9KHz
11 GOTO 00000000 ; Motor returns to zero at the of speed 2.9KHz
12 OUT nnn1 ; After return to zero ,The buzzer will alarm for a long time
13 END ; the program ends!
Example 4
:
Operating Requirements:
(Ignore the parameter setting) One object, from zero that run for a
high speed to run forward Until it came to the front of the limit switch, Then return to zero at the
same rate, the program ends. (Assume the system beginning frequency is 500Hz, the distance

14
/
17
from the zero to proximity switch is greater than 100 000 steps, less than 100010 steps). Design
analysis: the variable displacement of this movement does not know its precise value, but only
know it's a general range (belong to a unknown variable). We use a method for interrupting
operation to solve this problem. We connect the limit switch to the A operating port, Due the
interrupt operation,the motor will slow down to stop, If run to the limit switch as a high-speed
directly,will produce overshoot, In order to avoid the overshoot, we use this method that the first
run as a high-speed ,then run as a low-speed (low-speed is below the starting frequency).
Parameter List:
(Enter the parameter setting mode to modify) Setting A Operator address nA = 04,
other parameters are ignored.
Program Listing :
( enter the program edit state)
00 SPEED 39000 ; assign the speed as 39KHz
01 G-LEN 0099000 ; First, high-speed close to, but can
’
t hit the limit switch
02 SPEED 00400 ; low-speed frequency must below the starting frequency
03 G-LEN 07999999 ; The amount of displacement is set to the maximum, to reach the limit
switch
04 SPEED 39000 ; A Operator, assign the return to zero speed as 39KHz
05 GO-AB -A ; In the opposite direction, running the same amount of displacement,back to zero
06 END; the program ends!
Ⅻ
. directive search form
N
O.
Directive
Name
Example
Instructions, data range, unit
Directive
full name
Directive
abbreviati
on
1
pause
directive
00 PAUSE
Program pauses, waiting for the start signal
PAUSE
PAU
2
displacemen
t directive
01
G-LEN
-1234567
According to the latest SPEED assignment speed, reverse
mobile 1234567 step; pulses number
G-LEN
G-L
3
Speed
assignment
directive
02
SPEED
12345
Run this directive following assignment speed; 12345Hz
1-39999, pulses / sec (Hz)
SPEED
SPD
4
Delay
directive
03
DELAY
1234567
Delay time: 1234567 ms 1-7999999, ms
DELAY
OLY
5
Uncondition
al
jump
directive
04 JUMP
12
Unconditional jump to the line XII program runs
00-99, line number
JUMP
JMP
6
Cycle
directive
05 LOOP
03 12345
Jump from the current line to the (05) to 03 lines
for 12,345 cycles 1-99999 (0 defined as infinite),
Times (only forward loop)
LOOP
LOP
7
Move to
a position
06
GOTO
-1234567
Control the motor running to coordinate the
position of -7999999- + is -1,234,567 7,999,999,
the number of pulses (0 equivalent return to zero)
GOTO
GOT
8
Output
directive
07 OUT
03 01 N 0
Switch output is: 0UT = (K 0UT2 = 1,0UT3
unchanged internal buzzer a short sound (a =
long beep, N = no sound)
OUT
OUT

15
/
17
ⅩⅢ
. Parameters search form
9
Positioning
Jump
08 J-BiT
19 2 0
If IN2 = 0, then 1.2 = Line number which jumps
to line 19 execution data,
5 = input port, 8 = Jump status
J-BIT
J-B
10
Counting
Jump
09 J-CNT 20
12345
If the counter value> 12345, then jump to 20-line
program execution 0-59999, natural number
J-CNT
J-C
11
Variable
displacemen
t
09 GO-AB
-A
If the motor is running: the absolute value of the
displacement amount of A, A opposite to the
direction and the soil A,
±
B, the number of
pulses (Note: A, B itself as a symbol number)
Go-rb
GRB
12
Counter
Is
incremented
1
11 GNT-1
Value of the counter is incremented by 1 (Max
count up to 999999)
CNE-I
CNI
13
Counter
is cleared
12 GNT-O
Counter is cleared
CNE-O
CNO
14
Coordinate
cleared
13 CLR
Current coordinates and displays are cleared, the
motor this location as a new zero
CLR
CLR
15
End
of
directive
13 END
End of program lines, the directive can
’
t be
edited, it always located at the last line.
END
END
N
O.
Name
example
Data
range
unit
Parameter Description
1
Off
frequency
JF12345
400-3999
9
Hz
According to motor size and load
inertia, etc. to choose parameters
JF
2
Rising
and
falling curve
rS H
L,H
Strip
L slower; H faster (optimized design)
RS
3
Backlash
compensatio
n
CC1234
0 -9999
Pluse
number
Backlash compensation transmission
mechanism
CC
4
Manual
increment
HH 23456
1-999999
Pluse
number
When the manual mode, the amount of
displacement of the stepper motor
HL
5
Manual
speed
HF12345
1-39999
Hz
When the manual mode, the stepper
motor speed
HF
6
Back to zero
speed
bF12345
1-39999
Hz
When
return
to
zero
operation ,running speed of the
stepping motor
BF
7
"A
Operation"
entry
nA 18
00-99
Line
number
A operation is interrupted, the program's
entry address
NA
8
"B
Operation"
entry
nB 18
00-99
Line
number
B operation is interrupted, the program's
entry address
NB
9
Pulse mode
CP 0
0
、
1
CP = O single pulse, CP = I double pulse
CP

16
/
17
ⅩⅣ
. Button search form
Button
Function
Instruction
Use of state
Use
method
run
Start the program runs;
startup program continues
to run
Auto waiting to run status
;
run automatically stopped state;
When executing directive
pause
Click
enter
Confirm the modification of
the parameters are valid;
Confirm the changes or
enter the program effective
Parameter setting state;
program edit state
Click
Pause
Pause program is run
automatically; pause the
program is being run
Automatic
operation;
manual
operation status
Click
cancel
Cancel
modified
parameters; Cancel modify
or entry process
Parameter setting state; program edit
status
Click
home
let motor return to zero
(position when power is
on)
Auto waiting to run status
; The
automatic operation stop status;
Click
Clear
Clear
all
entered
program;
Program edit status;
Click for 2
seconds or
more
delete
Delete the current line
program
Program edit status;
Click
Auto
Converted to automatic
status:
manual
status;
Click
Jog
Converted
to
manual
status:
automatic status;
Click
Insert
Position in the program
above the current row
insert a new row program
Program edit status;
Click
Step
Displays
the
status
switches
to
coordinate
(steps) display
Auto waiting to run status
Click
count
Displays the status switch
to count display mode
Auto waiting to run status
Click
Program
Displays the status switch
to program display mode
Auto waiting to run status
Click
edit
Enter the program edit
status
manual
status;
Click
set
Enter the parameter setting
status
manual
status;
Click for 2
seconds or
more
quit
From the program edit
state or parameter setting
state return to manual
mode, and save the file to
save the modified program
or parameters
Program edit status; parameter
setting status
Click
Move
cursor
to left
Current position move to the
left
Program edit status; parameter
setting status
Click
Quick
View
Return
after
browsing
program, only the line
number
and
program
name, as this program to
see the data, click this
Program edit status
Click
Move
cursor to
down
Current position move down
one line
Program edit status; parameter
setting status
Click

17
/
17
Counter
is cleared
The current counter value is
cleared
Auto waiting to run status
Move
cursor to
right
Current position move to the
right
Program edit status; parameter
setting status
Click
Counter
save
Save the current counter
value
Auto waiting to run status
Click
reset
Reset Controller
Click