PDF User Manual

  1. Home
  2. Manuals
  3. CNB IDC4050IR Install Manual

CNB IDC4050IR Install Manual

IDC4050F IDC4050VR IDC4050VF

Made by: CNB
Type: Install Guide
Category: Security Camera
Pages: 18
Size: 2.53 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

1 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

 
 
 

XNET Network Dome Camera Install Guide 

( IDC4050IR, IDC4050F, IDC4050VR, IDC4050VF ) 

 
 
 
 
 
 

 

 

<IDC4050IR>                                                                    <IDC4050F> 

 

   

         

 

<IDC4050VR>                                                                  <IDC4050VF> 

 
 

 

Ver. 1.0 (101004) 

 


background image

2 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

About this Manual

 

 

A compatibility and durability test ensured this product’s high performance.   

 

This manual is for XNET IP Dome Camera users only, and it describes operations related to 

XNET IP Dome Camera.   

 

Please read this manual thoroughly paying attention to cautions and warnings before using 

the product even if you have used similar products before. 

 

 

Important Notices 

 

The copyright of this manual is owned by CNB Technology Inc.   
It is illegal to copy and distribute this manual without permission.   
Damages caused by use of parts not recommended and by misuse will not be 

applicable for support.     

Contact the store or the manufacturer immediately if (you think) there is any problem 

with the product.     

Contact the store or the manufacturer before disassembling the product for alteration 

or repair.   

XNET is a trademark of CNB Technology Inc.   
This product complies for CE (Europe) and FCC (USA) regulations for industrial/home 

use electrical device. 

 

 


background image

3 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

Index 

 

 

1. About XNET ......................................................................................................................... 4 

1.1. About XNET ....................................................................................................................... 4 

1.2. Features of XNET ............................................................................................................... 4 

1.3. Applications ....................................................................................................................... 4 

2. About the Product   ............................................................................................................... 5 

2.1. Contents ........................................................................................................................... 5 

2.2. Product Information   ......................................................................................................... 5 

2.2.1 Product Composition   ....................................................................................................... 5 

2.3. Hardware Designation   ...................................................................................................... 6 

2.3.1. Switch and Controls   ....................................................................................................... 6 

2.3.2 Connecting Cables ............................................................................................................ 7 

2.3.3 Connecting to Alarm Devices   ........................................................................................... 9 

3. Software Installation   ......................................................................................................... 10 

3.1. Installing XNET   .............................................................................................................. 10 

3.1.1. Installation  .................................................................................................................. 10 

3.1.2. Cable Connection   ........................................................................................................ 11 

3.2. Installing IP-Installer Software and Configuring IP address   ................................................ 12 

3.2.1. About IP-Installer 

   ...................................................................................................... 12 

3.2.2. Configuring IP Address

   ................................................................................................ 12 

4. Using Web Viewer   ............................................................................................................. 14 

4.1. Logging In   ..................................................................................................................... 14 

4.2. Web Viewer Page ............................................................................................................. 15 

5. Specification ...................................................................................................................... 17

 

 

 

 

 

 

 

 

 

 


background image

4 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

1. About XNET 

 

 

1

1

.

.

1

1

.

.

 

 

A

A

b

b

o

o

u

u

t

t

 

 

X

X

N

N

E

E

T

T

 

 

XNET is an internet based security and surveillance system that is compatible with various network conditions 

through  easy  installation  and  user  interface  as  well  as  multi-functional  compressor  Codec  such  as  H.264, 

MJPEG. XNET provides stable real-time surveillance by real time video/ audio at 1080P level, local storage for 

any network problems, and hybrid IP technology that can be used with existing analog CCTV devices.             

 

1

1

.

.

2

2

.

.

 

 

F

F

e

e

a

a

t

t

u

u

r

r

e

e

s

s

 

 

o

o

f

f

 

 

X

X

N

N

E

E

T

T

 

 

 

Most advanced Video compression technology (H.264/MJPEG) 

 

Progressive technology - Progressive scan makes the image sharp and clear without ghost effect. 

 

Hybrid IP Technology - CCTV analog video output can be used for existing analog CCTV devices. 

 

Transmission of Multi-Codec stream - Live video signal can be compressed to H.264 or MJPEG and sent to 

meet various applications of network or user. 

 

2-way Audio Communication (Bi-directional voice communication between Client’s PC and XNET)   

 

Smart Event feature - On the top of motion detection and sensor/alarm feature, pre- and post- alarm 

feature allows automated surveillance without an attendant’s monitoring.   

 

Install/ Operation Wizard - Install/ Operation Wizard not only makes it easy for installers and users, but 

also offers a unified installation setup for massive scale installations.   

 

Up to 3 motion detection areas   

and Video data transmission to FTP site or e-mail upon detecting a motion.     

 

Supports Various resolutions    - 1080P(1920x1080), SXGA(1280x1024), 720P(1280x720), D1(720x480), 

VGA(640x480), CIF(320x240) 

 

Remote Control over the network for software upgrade 

 

1

1

.

.

3

3

.

.

 

 

A

A

p

p

p

p

l

l

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

 

 

 

Surveillance  (Building,  store,  factory,  parking  lot,  financial  institutions,  government  buildings,      military 

facilities, etc.) 

  Remote  video  monitoring  (Hospital,  kindergarten,  traffic  monitoring,  remote  branch  office,  weather, 

environment preservation, and illegal disposal of trash, etc.) 

 

Real time broadcasting over the internet (Resort facility, parties, festivals, etc), remote business meetings, 

and educational trainings, etc. 

 

 

 


background image

5 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

2. About the Product   

 

2

2

2

2

2

2

2

2

....

....

1

1

1

1

1

1

1

1

....

....

    

    

C

C

C

C

C

C

C

C

o

o

o

o

o

o

o

o

n

n

n

n

n

n

n

n

tttt

tttt

e

e

e

e

e

e

e

e

n

n

n

n

n

n

n

n

tttt

tttt

s

s

s

s

s

s

s

s

    

    

Please make sure the following contents are included when you open the package

Contents 

Description 

Additional info. 

XNET 

XNET IP Dome Camera   

 

 

AC Power Cable 

2Jack Cable 

 

 

POWER ADAPTOR 

INPUT : 100~240VAC 50-60Hz 
OUTPUT : 12VDC 2A 

 

GUIDE PATTERN 

Guide Pattern 

 

 

CD   

Software and User’s manual   

 

Accessory   

Terminal (8P) 1EA, SCREW 3EA, Wall Anchors 3EA 

 

 

2

2

2

2

2

2

2

2

....

....

2

2

2

2

2

2

2

2

....

....

    

    

P

P

P

P

P

P

P

P

rrrr

rrrr

o

o

o

o

o

o

o

o

d

d

d

d

d

d

d

d

u

u

u

u

u

u

u

u

c

c

c

c

c

c

c

c

tttt

tttt

    

    

IIII

IIII

n

n

n

n

n

n

n

n

ffff

ffff

o

o

o

o

o

o

o

o

rrrr

rrrr

m

m

m

m

m

m

m

m

a

a

a

a

a

a

a

a

tttt

tttt

iiii

iiii

o

o

o

o

o

o

o

o

n

n

n

n

n

n

n

n

    

    

XNET 

(

IDC4050IR, IDC4050F, 

IDC4050VR, IDC4050VF

Install CD 

IP-Installer 

Viewer Program   

(CNB-CMS) 

 

 

 

IP Dome Camera 

(IDC4050VR) 

A software that assigns an IP address 
to the product     

A software that monitors and records 
Audio  and  Video  signal  from  the 
device   

 

2

2

.

.

2

2

.

.

1

1

 

 

P

P

r

r

o

o

d

d

u

u

c

c

t

t

 

 

C

C

o

o

m

m

p

p

o

o

s

s

i

i

t

t

i

i

o

o

n

n

 

 

XNET Product 

LENS 

IR LED 

DC FAN 

IDC4050IR 

FIXED LENS 

IDC4050F 

FIXED LENS 

IDC4050VR 

VARIFOCAL LENS 

IDC4050VF 

VARIFOCAL LENS 

 

 

 


background image

6 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

2

2

.

.

3

3

.

.

 

 

H

H

a

a

r

r

d

d

w

w

a

a

r

r

e

e

 

 

D

D

e

e

s

s

i

i

g

g

n

n

a

a

t

t

i

i

o

o

n

n

 

 

2

2

.

.

3

3

.

.

1

1

.

.

 

 

S

S

w

w

i

i

t

t

c

c

h

h

 

 

a

a

n

n

d

d

 

 

C

C

o

o

n

n

t

t

r

r

o

o

l

l

s

s

 

 

This shows Camera module inside the dome cover.     

 

 

 

 

 

 

 

 

 

 

 

 

Factory Reset 

Press and hold for more than 3 seconds while power is on to recall factory default settings 

 

 

Adjusting Lens   

Focus Adjust: Adjust the Focus using a knob. 

 

 

Power Terminal 

Network Terminal 

Factory Reset button 

Recalls 

factory 

default 

configurations 

IR LED 

Analog Video Output 

Alarm Input/Output 

CDS Sensor 

Mic/Audio Input 

Audio Output 

PWR,CPU,EVENT LED

PWR,CPU,EVENT LED

PWR,CPU,EVENT LED

PWR,CPU,EVENT LED    

Network 

DC FAN

DC FAN

DC FAN

DC FAN    

Megafixel

Megafixel

Megafixel

Megafixel    

fixed lens

fixed lens

fixed lens

fixed lens    

 


background image

7 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

2

2

.

.

3

3

.

.

2

2

 

 

C

C

o

o

n

n

n

n

e

e

c

c

t

t

i

i

n

n

g

g

 

 

C

C

a

a

b

b

l

l

e

e

s

s

 

 

 

 

Analog Video Output 

 

Use this output to monitor the analog video signal while installing.   

(Select Video Out at menu screen to enable this output) 

Power 

Supplies Power to the Xnet product. Use 12V DC Adapter in the package

 

 

Do  not  use  this  connector  when  powering  up  the  product  through  LAN 
cable.  (PoE)    The  product  is  not  covered  under  warranty  when  it  is 
damaged  by  connecting  both  Ethernet  power  and  12V  DC  power  to  this 
terminal. 

 

 

 

 

 

 

 

 

 

- Alarm Sensor Input (+) 

- Alarm Sensor Input (-) 

- Alarm Output 

- Alarm Output (COMMON) 

 

- MIC/ Line Input 

- GND 

- Line Output 

- GND 

Alarm Terminal 

Audio Connection Terminal 

Connect to a 

Connect to a 

Connect to a 

Connect to a 

Monitor

Monitor

Monitor

Monitor    

Connect to an 

Connect to an 

Connect to an 

Connect to an 

Adaptor

Adaptor

Adaptor

Adaptor    

 


background image

8 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

Audio Connection

Audio Connection

Audio Connection

Audio Connection

 

MIC/Line Input (Mono) 

Connects to auxiliary Audio Device or microphone.   

Line Output (Mono) 

Audio  signal  output  to  a  Power  Amplified  device  or  Speaker.  This  can  be  used  to  listen  to  the  audio 

signal sent from a remote PC for Bi-directional Audio communication. 

  ALARM Input/Output 

Connect to Alarm Input and Output   

 

Sensor Input : Wires from various sensor type (IR, heat, and magnetic) can be connected. 

 

Relay Output : Connect to an external Alarm device that operates by a relay such as Siren     

 

                  Lamp or Alarm Light.   

 

Please refer to 

“2.3.3 Connecting to Alarm devices” 

for Sensor and Relay connection. 

 

 

Network Terminal 

  This Ethernet terminal connects to 100Mbps LAN through an RJ-45 connector. When optional PoE is used, 

the power will be supplied from the Network Cable.   

 

Link LED 

Yellow light indicates that the network is properly connected.   

 

Act LED 

Green light indicates that the XNET system connected to 100Mbps LAN. This green lamp will blink if   

the system receives data. 

 

 

 

 

 

 

 

Act LED

Act LED

Act LED

Act LED    

Link LED

Link LED

Link LED

Link LED    

 


background image

9 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

2

2

.

.

3

3

.

.

3

3

 

 

C

C

o

o

n

n

n

n

e

e

c

c

t

t

i

i

n

n

g

g

 

 

t

t

o

o

 

 

A

A

l

l

a

a

r

r

m

m

 

 

D

D

e

e

v

v

i

i

c

c

e

e

s

s

 

 

 

 

Alarm Input 

Wires from various sensor type (IR, heat, and magnetic) can be connected to 

Alarm

 in(+)/(-) terminal as 

shown in figure 2.5. (NC or NO of sensor input can be selected at Menu screen.)   

Alarm Sensor device requires a separate power source. 

 

Internal Circuitry                                                                      External Circuitry 

 

 

Alarm Output 

This terminal can only be connected up to DC 30V/400mA.    An additional relay device has to be used to 

control higher voltage or current.   

 

Internal Circuitry                                          External Circuitry 

 

 

 

 

 

 

 

 

 

 

 

 


background image

10 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

3. Software Installation   

 

This  section  provides  brief  guidelines  to  install  the  XNET  quickly  and  to  monitor  XNET’s  Video  and  Audio 

signals  easily.    If  you  have  questions  about  details  not  explained  in  this  section  or  if  the  product  is  not 

functioning as described, please refer to FAQ before contacting the store.   

Our homepage is 

http://www.cnbtec.com

 

3

3

.

.

1

1

.

.

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

i

i

n

n

g

g

 

 

X

X

N

N

E

E

T

T

 

 

3

3

.

.

1

1

.

.

1

1

.

.

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

 

Mount the Camera to a ceiling or a wall. Make sure the base is firm enough to hold the Camera.   

 

                                IDC4050IR Model 

 

 

 

 

 

 

Adjust the position, zoom, and focus as shown below:   

 


background image

11 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

 

3

3

.

.

1

1

.

.

2

2

.

.

 

 

C

C

a

a

b

b

l

l

e

e

 

 

C

C

o

o

n

n

n

n

e

e

c

c

t

t

i

i

o

o

n

n

 

 

A PC or a laptop computer is required to set up an IP address. 

 

Compatible operating system: Windows 2000/ Windows XP/ Windows Vista 

 

Since  the  default  IP  address  of  the  device  is  192.168.123.100,  set  up  the  IP  address  of  the 

computer like the following:   

  IP Address : 192.168.123.101    Subnet Mask : 255.255.255.0 

Connect LAN cable to the Network Terminal of the product.( Use a crossover cable when connecting 

it directly to a PC, and use a direct cable when connecting it to a HUB)                           

                         

                                     

 

 

 

 

 

 

Connect the camera to the power. 

 

Use the Alarm Sensor/ output and audio terminal if necessary. 

TILT : 90˚ 

Horizontal   

Rotation : 360˚ 

PAN : 360˚ 

FOCUS 

ZOOM 

COMPUTER 

Direct Network 

Cable 

NETWORK HUB 

COMPUTER 

Crossover 

Network Cable 

  Cable 

 


background image

12 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

3

3

.

.

2

2

.

.

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

i

i

n

n

g

g

 

 

I

I

P

P

-

-

I

I

n

n

s

s

t

t

a

a

l

l

l

l

e

e

r

r

 

 

S

S

o

o

f

f

t

t

w

w

a

a

r

r

e

e

 

 

a

a

n

n

d

d

 

 

C

C

o

o

n

n

f

f

i

i

g

g

u

u

r

r

i

i

n

n

g

g

 

 

I

I

P

P

 

 

a

a

d

d

d

d

r

r

e

e

s

s

s

s

 

 

 

3

3

.

.

2

2

.

.

1

1

.

.

 

 

A

A

b

b

o

o

u

u

t

t

 

 

I

I

P

P

-

-

I

I

n

n

s

s

t

t

a

a

l

l

l

l

e

e

r

r

 

 

 

 

A unique IP address has to be configured in order to connect IP camera and monitoring PC to a 

network. IP-

Installer  software  provided  in  the  Installation  CD  (included  in  the  package  and  also  available  to  download 

from  our  website  http://

www.cnbtec.com

)  will  configure  IP  address  easily.  If  your  network  have  a  DHCP 

server that automatically assigns IP addresses to IP cameras. If your network does not have a DHCP server, 

the default IP address of the device is 192.168.123.100. Refer to IP Installer user’s manual for detail. 

 

3

3

.

.

2

2

.

.

2

2

.

.

 

 

C

C

o

o

n

n

f

f

i

i

g

g

u

u

r

r

i

i

n

n

g

g

 

 

I

I

P

P

 

 

A

A

d

d

d

d

r

r

e

e

s

s

s

s

 

 

 

 

A. The following box will appear when you start the IP-installer software.   

 

 

 

Figure 3-2. IP Installer Start box 

 

 

 

 

 

 

 

 

 

 

 


background image

13 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

B. Select the camera of which you wish to change the IP address and click 

(Set IP Address)   

button to bring up the following box in Figure 3-3.   

 

 

Figure 3-3. IP Address box 

 

C. When you enter the IP address and click Set button, the box shown in Figure 3-4 will appear.   

 

Figure 3-4. Select 

Network Adapter Box 

 

D. Select the adapter and click select button to change the IP address of the camera. 

 

 

 

 

 

 

 

 

 

 


background image

14 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

4. Using Web Viewer   

 

Connecting to network devices can be done using internet web browser or “XNET-CMS” software.    This guide 

explains  about  using  internet  web  browser  only.  For  instructions  on  how  to  configure  network  connection 

using 

XNET-CMS software, 

please refer to 

XNET-CMS Manual, which can be found in the installation CD.   

 

4

4

.

.

1

1

.

.

 

 

L

L

o

o

g

g

g

g

i

i

n

n

g

g

 

 

I

I

n

n

 

 

Enter the IP address of the device on the address bar of your web browser and press enter key. Then the 

following webpage will appear: 

 

 

 

Figure 4-1 

Log-in Box 

 

Enter  the  user  name  and  password  to  bring  up  the  web  viewer  page.  The  default  id  and  password  is 

root

”, “

admin

” respectively. If  you want to use a different HTTP port number from the default value, 

simply  put  a  colon  and  port  number  at  the  end  of  the  IP  address.  (For  example,  enter  the  following 

address when changing the port to 8080: 

http://192.168.123.100:8080

 

 

<Address format for accessing as an administrator> 

 


background image

15 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

(When using default IP address and port number)     

        http://192.168.123.100 

(When IP address and port number changed)                     

http://IP

 address: new port number 

 

 

 

 

 

 

4

4

.

.

2

2

.

.

 

 

W

W

e

e

b

b

 

 

V

V

i

i

e

e

w

w

e

e

r

r

 

 

P

P

a

a

g

g

e

e

 

 

Web viewer page consists of Video monitor screen and menu option buttons.   

 

 

Figure 4-2 Web Viewer

 Page 

 

 

If  you  forget  the  administrator’s  password,  “Factory  Reset”  is  the  only  way  to  regain  access. 
However, since this will retrieve all default settings, you need to configure the network settings 
using IP installer software again. 

For  security  purpose,  it  is  recommended  to  change  the  administrator’s  id  and  password  from 

their default values. Please be careful not to forget them or expose them to others.    Please refer 

to 

[

Web Viewer Manual] 

for detail

 


background image

16 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

Item 

Sub Item 

Description 

Capture 

Captures and saves the current image as a still picture. 
The image is saved as jpeg file in the following folder: 

C:

\

xNetCapture   

Setting 

Brings up Menu screen. 
Setup page for each XNET feature can be opened from this Menu screen.   

Please refer to [XNET Owner’s Manual] for detail.   

Live View 

Main Stream 

When this box is checked, Main Stream Video is displayed.   

Sub Stream 

When this box is checked, Sub Stream Video is displayed. 
Dual-Codec  needs  to  be  enabled  in  Video  Setup  Page  in  order  for  Sub 

Stream to be displayed.   

Please refer to [XNET Owner’s Manual] for detail. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

17 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

5. Specification 

 

XNET IP HD - IDC4050F / IDC4050IR / 

IDC4050VF / IDC4050VR 

Specifications 

Camera 

Signal System 

Progressive image processing 

Scanning System 

16:9 Progressive 

Pixel Clock 

80MHz 

Image Sensor 

Progressive CMOS Sensor 

Sync. System 

Internal 

Effective Pixels Number 

1920 (H) x 1080(V) 2.0 Mega 

Horizontal Resolution 

1100 TV Lines 

Video Output Level 

Select NTSC/PAL 1.0Vp-p (BNC 75Ω, composite) 

Lens 

Built-in Fixed Mega pixel Lens, f=4.0mm, F 1.8              *IDC4050F / IDC4050IR 
Built-in  DC  Iris  Vari-focal  Lens,  f=3  ~  10mm,  F  1.2          *IDC4050VF  / 
IDC4050VR 

Min. Illumination 

1 Lux (DSS on),    0 Lux (IR on)    *IR model only 

IR LED and Sensor 

850nm / 45˚ IR LED 18EA, Sensor 1EA          *IDC4050IR / IDC4050VR 

Day & Night System 

ICR(CDS Type) 

Back Light Compensation 

On/Off 

Flickerless 

On/Off 

White Balance 

Auto/Manual 

Exposure 

Auto/Manual 

Functions 

B/W 

Electronic Shutter Speed 

1/7.5 ~ 1/8000 (21 Step) 

Video / Audio 

Compression 

H.264 / MJPEG (sub stream only) 

Frame rate 

NTSC : 1, 5, 15, 30 fps 

PAL : 1, 5, 12.5, 25 fps 

Resolution 

Full HD(1920 x 1080), SXGA(1280 x 960), 720P(1280x720), 
D1(720 x 480 / 720 x 576), VGA(640x480), CIF(352 x 240 / 352 x 288) 

Audio 

Two-way (Full duplex / G.711) 

Network 

Protocol 

IPv4, HTTP, TCP, RTSP, RTP, UDP, SMTP, FTP, 
ICMP, DHCP, UPnP, Bonjour, ARP, DNS, DynDNS 

Supported DDNS 

1. CNB DDNS    2. DynDNS.org 
3. Reference code with SDK 

LAN Interface 

Ethernet 10/100 Base-T (RJ-45 Type) 

Support PoE 

Standard IEEE 802.3af supported 

Security 

Access level setup 

Multiple user access levels with password protection 

Network Security 

IP Filtering 

Alarm and Event 

Management 

Image detection 

Motion detection (Select 3 Regions - each area) 

Sensor detection 

Sensor In, Alarm out 

After Event process 

JPEG Image upload over FTP server / SMTP (E-mail server) 
AVI Movie upload over FTP server 

Applications 

Browser 

Internet Explorer 6.0 or later 

Monitoring Application 

XNET NVR, CNB CMS and Utility (IP-Installer, etc) 

Maintenance 

System Upgrade 

Firmware upgrade over HTTP 

Mechanical 

Operating Temperature 

0  ~ 40

 

Power 

DC 12V Max. 7 W 

Dimensions / Weight (Net) 

92(Ø) mm 

 

 


background image

18 / 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

D

D

o

o

m

m

e

e

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

G

G

u

u

i

i

d

d

e

e