Full Text Searchable PDF User Manual

CCU-550 Modem User Guide
FCC RF EXPOSURE COMPLIANCE
In August 1996 the Federal Communications Commission (FCC) of the United States with its action in Report
and Order FCC 96-326 adopted an updated safety standard for human exposure to radio frequency (RF)
electromagnetic energy emitted by FCC regulated transmitters. Those guidelines are consistent with the
safety standard previously set by both U.S. and international standards bodies. The design of this modem
complies with the FCC guidelines and these international standards.
Use only the supplied or an approved antenna. Unauthorized antennas, modifications, or attachments could
impair call quality, damage the modem, or result in violation of FCC regulations.
This CDMA 1xEVDO USB data modem has been tested for FCC RF exposure hand and body SAR
compliance with the CCU-550 USB dongle modem form factor. In order to comply with FCC RF exposure
requirements, the CDMA 1xEVDO USB data modem must be operated with the CCU-550 USB dongle
modem form factor. The use of this device in any other type of host configuration may not comply with FCC
RF exposure requirements and should be avoided. During operation, a 1.5cm separation distance should be
maintained between the antenna, whether extended or retracted, and the user’s/bystander’s body (excluding
hands, wrists, feet, and ankles) to ensure FCC RF exposure compliance.
CAUTION
Change or modification to the modem without the express consent of CMOTech Co., Ltd. voids the user’s
authority to use the equipment. This equipment has been tested and found to comply with the limits pursuant
to Part 22 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in an appropriate installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not used in accordance with instructions, can cause harmful radiation to radio communication.
However, there is no guarantee that interference will not occur in a particular installation. If the equipment
does cause harmful interference in radio and television reception, which can be determined by turning the
equipment on and off, the user is encouraged to try to correct the interference by one or more of the following
measures:
■
Reorient or relocate the receiving antenna
■
Increase the separation distance between the equipment and the receiver
페이지 1 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

■
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
■
Consult the dealer or an experienced Radio / TV technician for help.
CAUTION
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communication. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful unacceptable interference to radio and television reception,
which can be determined by turning the equipment on and off, the user is encouraged to try to correct the
interference by one or more of the following measures:
■
Reorient or relocate the receiving antenna
■
Increase the separation distance between the equipment and the receiver
■
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
■
Consult the dealer or an experienced Radio/TV technician for help.
CAUTION
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions ; (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
POTENTIALLY UNSAFE AREAS
Posted facilities
: Turn off this device in any facility or area when posted notices require you to do so.
Blasting areas
: Turn off your modem where blasting is in progress.
Observe restrictions and follow any regulations or rules.
Potentially explosive atmospheres
: Turn off your modem when you are in any area with a potentially
explosive atmosphere. Obey all signs and instructions. Sparks in such areas could cause an explosion or fire,
resulting in bodily injury or death.
Areas with a potentially explosive atmosphere are often but not always clearly marked. They include:
z
fuelling areas such as gas or petrol stations
페이지 2 / 22
제목 없음

z
below deck on boats
z
transfer or storage facilities for fuel or chemicals
z
vehicles using liquefied petroleum gas, such as propane or butane
z
areas when the air contains chemicals or particles such as grain, dust or metal powders
z
any other area where you would normally be advised to turn off your engine
It is recommended that this manual be read in conjunction with all other supporting documentation.
CCU-550 Modem Install
Setup
Insert installation CD (supplied with CMOTech Data Modem) into the CD-ROM drive.
This will automatically start the installation and install the required drivers plus CMOTech Data Modem
Application software.
Do not connect CMOTech Data Modem into your laptop/PC yet.
The installation procedures are the Windows 2000 and Windows XP.
Start setup
If the auto run does not start after inserting the CD, please double-click on “Setup.exe” file on CD ROM to
start the installation.
If you have already inserted your Modem into your PC, remove the Modem and double-click “Setup.exe”
페이지 3 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Start Auto Run
Install Shield Wizard... click 'next'
페이지 4 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Choose the installation directory and click "Next" to continue.
CMOTech Modem is configuring your new software installation.
Copying Step1 File
페이지 5 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Copying Step2 File
Check device
페이지 6 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Installation Complete. Click “Finish” and remove the installation CD.
페이지 7 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Insert Modem
Please Insert Modem
On Window 2000
As inserting Modem on Window 2000, there will not be any window and users can run applications after the
device is detected.
On Window XP
If your operation system is XP on inserting Modem, you can see “Find New Hardware” Dialog.
Click ‘Next’ button.
페이지 8 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Click ‘Continue Anyway’ button.
페이지 9 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Click ‘Finish’ button.
페이지 10 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Using the CCU-550 Modem Application Software
During this installation a Shortcut will have been placed on your desktop for the CMOTech Data Modem
Application software.
Note
: If the modem is connected to the Laptop/PC via serial port, the user will have to select the serial port
initially when the User Interface software starts up.
On auto start of the Application Software, the first screen you will see Main window.
Main
Indicator state Icons
Icon
Meaning
Icon
Meaning
No Signal
Roaming
Antenna / Signal Strength
Coverage Icon. CDMA 1x
available
Current High Data Rate
mode selected : Hybrid Mode
(1xEV-DO Preferred)
DEFAULT. The modem will
automatically look for the
highest speed network
available in this mode.
Coverage Icon. IS95 available
only
Current High Data Rate
mode selected: CDMA 1X
only Mode
Coverage Icon. 1xEV-DO
available
페이지 11 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Taskbar Icon
When the Application Software is running in the background, the Windows taskbar will show an icon as
above.
To maximize the Application Software, double click on the icon.
Dial up Network
Connection
Clicking the ‘Connect’ button. The Application Software will start dialing the Service Option selected
under dial-up when the “Connect” button is clicked (The “Connect” button can be clicked on the main window).
Current High Data Rate
mode selected: 1xEV-DO
only Mode.
Active Data connection
Dormant Data connection
페이지 12 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Verifying User.
Registering your computer on the network.
You can see above window’s right blue icon. This icon show on connection.
Warning : If you install Windows XP service pack 2, you must turn off firewall in Window security center.
If you try connecting with turn on firewall, you can see connecting fail.
Click the Windows taskbar's shield - shaped Yellow icon, you can see Window Security center
To Disconnect
Clicking the disconnect button on the Main window or Dial up slide window, will disconnect the dialup
connection and the modem will switch to idle mode.
페이지 13 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Clicking the ‘Yes’ button.
Active and Dormant state
It is on Active state when an active icon
appears on the window.If having no data transmission during
Dialup, it goes to Dormant state.
Users can discern that it is on Dormant state with an icon
displayed on the screen.
Option
페이지 14 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

General
NOTE : The ‘Apply’ button must be clicked for any changes to take effect.
Application Software auto run
: This Check box determines whether the Application Software starts
automatically
when the Modem is connected. Check the check box and press ‘Apply’ button.
Power Control
: When selected will switch the Modem off when the Application Software is closed.
If de-selected the Modem stays on when Application Software is close.
페이지 15 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Hibernation
: With the Application Software running (idle). Windows will not hibernate or switch to standby
mode.
Please select this option under General tab to close UI automatically so that windows can hibernate or switch
to standby.
Data
Connection setting
페이지 16 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

To Setting Dial-Up connection, click ‘Option’ button and click ‘Data’ button.
Also to change connecting type, click the radio Button.
NOTE : You can use Packet, QNC type in 1X current coverage. And can’t use Packet type in IS 95
coverage.
Connecting is also possible to connect (Dial-up) by clicking the connect button on the main window without
opening
the Dial-up setting window. When clicking the connect button, the last Service option will be used for dial up.
If the user changes the username or password and clicks Connect, the Application Software will store the new
username and password.
To load the The default username and password select the ‘Restore’ button, and the ‘Apply’ button must be
clicked.
Dial-up Networking - Packet
Always On is a CDMA 1x internet domain that applies to data (in Kilobytes) based charging packages.
This service allows you to remain connected to the internet all the time.
charges will apply to the amount of data sent and received with this domain.
Dial-up Networking - QNC Standard.
When you are not within CDMA 1x coverage or you have not subscribed to CDMA 1x, you can still connect to
operator's Standard Mobile internet Service using Quick Net Connect, provided you are withis CDMA
coverage.
Quick Net Connect (QNC) does not require a separate subscription
About
It displays Software/ Firmware Version, PRL ID as shown below.
페이지 17 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Data Logs
Data Logs
The User Data Counter will continuously accumulate on each session and will only clear when “Clear Data
Count” is clicked.
페이지 18 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Uninstall
Uninstall CMOTech CCU-550 Modem
To uninstall CMOTech CCU-550 Modem driver, click “Uninstall”.
Start uninstall
Execute the Uninstall program.
페이지 19 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Execute “setup.exe” in installation folder or click “Uninstall”
Auto Run
Press button
As clicking Uninstall icon, you can see a dialog below. Click yes button.
페이지 20 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

Uninstall continue.
Uninstall program remove file in your PC. (Uninstall Program deletes Drivers, Modem and Modem Application
Program.)
Uninstall Complete. Click ‘Finish’ button.
페이지 21 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...

페이지 22 / 22
제목 없음
2005-06-13
file://C:₩Documents%20and%20Settings₩Owner₩Local%20Settings...