PDF User Manual

  1. Home
  2. Manuals
  3. CLR Networks CLR-IES-42S User Manual

CLR Networks CLR-IES-42S User Manual

Made by: CLR Networks
Type: User Manual
Category: Network Router
Pages: 18
Size: 0.23 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 

 

 
 

CLR-IES-42S   

Unmanagment Industrial 

Ethernet Switch 

 

User manual 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

  (First Publish

Edition: V3.1 

 

 

 


background image

 

 

 

Notice:   

Before using this manual, please read the following license 
agreement. 
 
Important declaration: 
The  company  provided  in  this  manual  for  any  information, 
does not mean  these informations  can  provide  to  the  third 
parties. 

Notice: 

AS  technical  developing 

maybe  some  part  of 

the datasheet    get different with actual product. 
Pretty  sorry  for  this,  if  want  more  news  about 
products.  Please  check  our  website  or  connect 
with our sales directly 

 


background image

 

 

SAFETY PROVISION FOR THE USING NOTICE 

This  product  is  designed  as  a  good  and  reliable  quality, 
however it still need to avoid human hurt or destroy. 

 

Please read carefully and keep this manual for 
search. 

 

Do  not  place  the  equipment  near  water  or 
moisture. 

 

Do  not  put  anything  on  the  power  line,  it 
should be in the not touch place. 

 

To avoid fire, do not put power lines together 
or firmly connected to each other. 

 

Please  always  check  power  control  whether 
fix up with other equipments. 

 

Please keep optical fiber ports and slots clean. 
When it work, not lock fiber cross section. 

 

Please  keep  equipment  clean,  please  use  a 
soft cotton wipe it. 

 

Please follw use manual, please do not repair 
by youself. 

When  appear  following  cases,  please 

shutdown  power 

and directly connect with our company. 

 

Water split 

 

Equipment break or crust broken. 

 

Equipment working abnormity or need update. 

 

Equipment  gets  some  smell  or  smoke  or 
noise.

 

 


background image

 

 

Catalogue 

 

Chapter  1  Introduction                                             

  1 

Chapter  2  Product  Introduction                                   

Chapter  3  Hardware  construction                                 

    3 . 1   C L R - I E S - 4 2 S E t h e r n e t   s w i t c h                       4 

    3.2 CLR-IES-42S Front Panel                                                 

                                             

3.3 LED indication light                                                     

 

    3.5  Power  supply  input  PIN                                                6 

Chapter  4  Hardware  installation

                                      7 

    4.1  DIN-Rail  installation                                                        7 

    4.2  Cable  Connection                                                          7 

    4.3  Fiber  Connection                                                            8 

Chapter  5  Testing  guide                                           

        9 

    5.1  Self-examination                                                            9 

    5.2  RJ45  Port  Test                                                                9 

    5.3 Fiber Optic Port Test                                                      10 

Chapter6  Network  and  System  Allocation     

            11 

    6.1  Network  Construction                                                  11 

    6.2  System  Allocation                                                        11 

Chapter 7 Maintain and Service.

.....................................13 

7.1  On-line  service............................................................13 

7.2  Customer  service........................................................13 

7.2  Warranty  Policy...........................................................13 
 

 


background image

 

 

 

 


background image

 

 

- 1 -

Chapter 1 Introduction 

1

CLR-IES-42S Industrial Ethernet Switch 

 

The  MIEN2206-2S/2M  is  two  100Base-FX  and  four  10/100 
Base-TX  DIN-Rail  industrial  Ethernet  Switch.  Models  with  an 
extended  operating  temperature  range  of  -40

75°C  are  also 

available.  DIN-Rail  installation;  Housing  use  IP40  protection  and 
interface LED indication can display socket state.

 

 

The  unmanagement  series  of  switch is  suitable for  plug-and-play. 
All  10/100  Base-TX  ports  support  many  functions  of  automated 
trust  negotiation,  10/100Mbps  full  duplex  and  half  duplex,  flow 
control, Auto-MDI/MDI-X and so on. 

2.    CLR-IES-42S Product characteristic

 

 

High  performance  for  industrial  Ethernet  Switch10/100Base-TX 
adapt port(full/half duplex

),

auto connection with MDI/MDI-X. 

 

Broadcast Storm Protection. 

 

Rugged Design 

 

Ribbed heat-removal design; operation at -40

 to +75

 

High  performance  protection  class  with  aluminum  case  ,keep 
system working in danger and hard industrial environment. 

 

Easy DIN-Rail mounting.   

Redundancy power supply 

When  industrial  power  supply  use  DC9~36V  or  DC48V,it  support 
redundant 

double 

power 

supply 

back-up;                                                               

When industrial power supply use AC/DC 110V or AC/DC220V, it has 
only one power supply input.   
Reliable protection for EMC and against over current / over voltage 
CLR-IES-42S support relay output warning for power failure. Relay can 
give output alarm in case of power supply failure or interruption of port 
link  to  notice  or  remind  site  engineers  to  make  quick  response  for 
appropriate emergency maintenance.   

 

3

CLR-IES-42S packing list. 

Item 

QTY 

 


background image

 

 

- 2 -

CLR-IES-42S industrial Ethernet Switch  1pcs 

User manual 

1pcs 

Inspection Report for Industrial Ethernet 
switch 

1pcs 

 
 

 


background image

 

 

- 3 -

Chapter 2 Product Introduction 

2.1 Product parameters 

Content 

CLR-IES-42S 

RJ45 ports 

                   
     
                          4x 10Base-T/100Base-TX 
               

Optic ports 

                                  2 x100Base-FX   
 

System 
parameter 

Standard

IEEE 802.3, IEEE 802.3u, IEEE 802.3x

 

store-and-forward mode rate

148810pps 

MAC address table size

2K 

Converter  method: 

store-and-forward  mode

  Broad  cast 

storm Protection 

Electric 

port 

parameter 

Physics socket: RJ45 Socket(shielded) 
RJ-45 socket: 10Base-T/100Base-TX,auto negotiation 
Socket standard: IEEE802.3 standard 
Communication distance: <100m 

Optic 

port 

parameter 

Link  Budget:                  >-12dBm(Single  mode 

fiber); >-17dBm(Multimode fiber) 

RX Sensitivity:                <-38dBm(Single mode fiber);  

<-35dBm(Multimode fiber) 

Optic 

port 

parameter 

Wavelength:  1310nm(Single mode);    1550nm  (Single  mode); 
1310 nm (Multimode) 
Typical  Distance:  20

80Km  (Single  mode)  ;  <5Km  (Multi 

mode) 
Converter type: SC/FC/ST 
Transport rate: 125Mbps 

Power 
parameter 

Voltage input : DC9

36V 

Input expend: <5W 
Voltage passing: Inside 

Technical 
parameter 

Dimensions  (H

×

W

×

D):  144

×

33

×

97mm  (not  include 

DIN-Rail parts dimension) 
Installation method: DIN rail 
Weight: 0.8

 

Working 
environment 

Operation: -20

℃~

+70

 

Store: -45

℃~

+85

 

Ambient Relative Humidity: 0

95% (non-condensing) 

 

 


background image

 

 

- 4 -

Chapter 3 Hardware construction 

3.1 

CLR-IES-42S

 Ethernet switch 

CLR-IES-42S Ethernet switch case is a small Din-rail structure. 
The whole machine use six –sides sealed structure. The outside size is   
144mm x 33mm x 97mm (not including Din-rail size ). 

3.2 

CLR-IES-42S 

Front Panel 

The CLR-IES-42S is two 100Base-FX and Two 10/100 Base-TX. 

 

3.3 LED Indication lights 

The  front  panel  of  CLR-IES-42S  industrial  Ethernet  switch  have  LED 
contains several LED indicator, it can display socket state and easy to 
find & solve problem. 
 

LED 

Lights 

Status 

P1/P2 

On 

Power connect and work normal 

Off 

Power not connect or work not 

normal 

RUN 

On 

System work normal 

Off 

System not work normal   

LINK 

On 

100Base-FX have network 

connection   

Blinking 

100Base-FX network active   

Off 

100Base-FX network not connect 

10M/100M(Yellow) 

Port rate 

On 

100Mbps is active(100Base-TX) 

Off 

10Mbps is active(10Base-T) 

 


background image

 

 

- 5 -

Link/Act(Green) 

On 

Port have build active network 

connection 

Blinking 

Port active   

On 

Port do not network connection   

 

 


background image

 

 

- 6 -

3.5 Power supply input PIN 

 

 
 
 

  Side panel have one port could connect with ground directly. 
The   
CLR-IES-42S industrial Ethernet switch have standard DC9~36V power 
supply input. Also could choose DC48V input. When choose these two 
voltage , the Ethernet switch support dual power input , as spare use . 
The CLR-IES-42S industrial Ethernet switch could support AC/DC110V 
or AC/DC220V

if chose this two kind voltage input, input must from V1+ 

and  V1-,  V1+  connect  with  live  line  L,  V1-  connect  with  null  line  N. 
Please do not connect fromV2+ and V2-. 
 

 

 

 

 

Power Down Warning   

That  series  Ethernet  switch  support  power  down  warning  function. 
When  Ethernet  Switch  normally  supply  power  ,  relay  constant  close 
contact open , when Ethernet switch do not have power input or input 
power not normal , relay contact will close . 

 


background image

 

 

- 7 -

Chapter 4 Hardware Installation 

4.1 DIN-Rail installation 

That  series  equipment  back  panel  have  fixed  well  DIN  rail-way 
connection  seat.  If  need  installation,  please  check  DIN  rail  way 
condition . Main including 2 terms : 

 

Checking  DIN-Rail  is  fixed  firm,  DIN-rail  is  installed  on  other 
equipment, whether there is enough space .

 

 

Checking DIN-Rail whether suitable for power input.

 

 

Please  selected  the  correct  position.    As  below  behind  picture 
shows: 

 

Insert DIN-Rail into DIN-Rail slot and as schematics 4-1 A shows 
turning equipment

 

 

As schematics 4-1 B shows, insert DIN-rail into DIN-Rail slot and 
confirm equipment installed on the DIN-rail.

 

as show in figure 4-1 

 

4.2 Cable connection

 

  

 

After  install  Ethernet  switch  ,  please  connect  install  cable.  Cable 
installation please following behind notice: 

Equipment port connection 

This series provided 10Base-T/100Base-Tx RJ45 interface port, use the 
straight-through wire connect with terminal equipment , use cross wire 
connect network equipment . 

Figure 4-1 Installing industrial Ethernet switch in DIN-Rail 

 


background image

 

 

- 8 -

Industrial Power supply 

This  series  Ethernet  switch  supply  DC9--36V  power  (or  48V  DC 
power  ,220V  AC  power).  After  all  other  cables  connected,  you  can 
connect the power . 

4.3 Fiber connection 

This series Ethernet switch provide full-duplex 100Base-FXsingle-mode 
or  multimode  fiber  interface.  Optical  interface  type  can  be  selected 
according to requirements of SC / ST / FC. 

Attention

 

This switch uses lasers to transmit signals over fiber cable. Laser 
Class 1 laser/LED products can cause serious damage on the eyes 
harmless.  When  the  equipment  is  power  on,  please  do  not  stare 
directly into the laser beam.

 

Connection optic cable , please use following steps: 

 

When use fiber cable port, remove SC/FC/ST port cover; When it 
finish  work,  please  put  the  plastic  cover  to  protect  the  fiber  optic 
head, keep clean. 

 

Check  the  fiber  optic  cable  head  whether  it  clean  or  not.  If  it  not 
clean, will effect port and communication quality. 

 

One  fiber  optic  head  connect  with  Ethernet  switch  optic  port,  the 
other  fiber  head  connect  with  another  equipment  fiber  optic 
interface equipment. 

 

After  connection,  please  check  switch  the  front  interface’s 
LNK/ACT LED lights. If lights on, connection is available. 

 
 
 
 
 
 

 


background image

 

 

- 9 -

Chapter 5 Testing Guide 

5.1 Self-examination 

When  the  equipment  on  power  ,  front  panel  all  port  indicate  light  will 
shine in all, shine in turn once , that mean all ports work normal .   

5.2 

RJ45 Port Testing

 

As schematics 5-1 shows, when Ethernet switch on power,   
Choose any two RJ45 ports through directly network link connect with 
two testing PC network interface. and send Ping command each other, 
the  two  sides  get  right  Ping  message  and  don’t  loss  package.  At  the 
same time the yellow light on the corresponding port should be normally 
on (PC network card work in 100M Status) or light off (PC network card 
work in 10M Status), corresponding port green light should be shining . 
That means the testing two RJ45 ports working well. 
 
 
 
 

 

 

 

 

 

 


background image

 

 

- 10 - 

5.3 Fiber optic port testing 

Connect  equipment  (with  optic  port  )  as  picture  5-2  optic  link  network 
(Tx    connect  other  set  of  Rx,  Rx  connect  with  other  PC  Tx).  Choose 
any  RJ45  port  of  Ethernet  switch  directly  link  network  connect  with 
testing computer , and send Ping command each other , make sure two 
sides not lose package , and the same time corresponding optic port ‘s 
LINK light shine , that means two optic ports hardware working normal. 
Below picture is CLR-IES-42S optic port testing picture . 
 
 
 
 
 

 

 
 

 


background image

 

 

- 11 -

Chapter 6 Network and System Allocation   

6.1 Network construction 

CLR-IES-42S that series Industrial Ethernet switch provide   
2

8  x10Base-T/100Base-TX  RJ45  ports.  Each  ports  can  directly 

connect  witch  terminal  equipment,  or  connect  another  industrial 
Ethernet/hub with terminal which used as shared internet link. 

 

6.2 System Allocation 

 

CLR-IES-42S series Ethernet switch standard power supply is 
DC9--36V. Users can choose according to the actual situation 
DC48V or DC110/220V power or AC110V/220V power. 

 

Choose DC48V, input voltage is DC36—60V. 

 

Choose DC110/220v, input voltage is DC110—360v 

 

Choose AC110/220V , input voltage is AC85—265v 

 

Fiber optic port can be single mode/ multi mode and SC/ST/FC 
port. Standard allocation is SC single mode . 

 

 

 

Order Information   

 
 
 

Model 

Description   

CLR-IES-42S 

2 x 100Base-FX single –mode optic port 
2 x 10/100Base-TX Ethernet RJ45 port 

 


background image

 

 

- 12 - 

 

 
 
 

 


background image

 

 

- 13 - 

Chapter 7 Maintain and Service 

The  switch  has  5  years’  guarantee.According  to  the  Product 
Specifications of Maiwe, we will maintain or change the product for free 
which  has  any  problem  in  this  guarantee,of  that  is  not  including  the 
destroy  of  error  usage,accident,  natural  disaster  and  uncorrect 
installation. 
To ensure the customer’s profit, we also provide some methods to help 
the customer and solve their problem as followings: 
Service on line 
Call for our customer service 
Maintain or exchange 

7.1 On-line service 

In our website,you can get more useful product information and usage 
methods in the part of technical support. 

7.2 Customer service 

when you have any problem, please contact our technical support staff 
unhesitately.Our engineer will give you reply and solve your problem as 
soon as possible. 

7.3 Warranty Policy 

According  to  the  solving  process,  maintain,exchange  or  return  should 
be  confirmed  by  our  technical  staff.  You  have  to  contact  our  sales 
person to solve after this kind of negotiation. 
1. We can exchange the product in 3 month for the quality problem. 
2. We guarantee to keep the product in good repair for 5 years.