background image

manual

V1.0 APRIL 2018

WWW.CLF-LIGHTING.COM

ef smoke 3100

 


background image

WWW.CLF-LIGHTING.COM

2

Machine overview

3

Safety instruction

4

AC power

6

Data link

6

Physical installation

7

Operating instructions

7

Menu navigation

DMX channels

9

Maintenance

10

Specifications

11

                               

table of CONTENTS

 


background image

WWW.CLF-LIGHTING.COM

3

machine overview

1. 

Nozzle

2. 

LED

3. 

2,5L tank

4. 

Tank fixing plate

5. 

Fluid tube

6. 

LCD display

7. 

3-pin DMX socket

8. 

5-pin DMX socket

9. 

USB

10. 

Ventilation

11. 

Handle

12. 

Safety point

13. 

Power switch

14.  PoweCON

15. 

Overload protection

 


background image

WWW.CLF-LIGHTING.COM

4

Safety Instruction

The following symbols are used to identify important safety information on the product and in this manual:

                                          WARNING!

       Read the safety precautions in this section before

        installing, powering, operating or servicing this

product

DANGER!

Safety hazard.

Risk of severe

injury or death.

DANGER!

Hazardous

voltage. Risk of

lethal or severe

electric shock.

WARNING!

Fire hazard.

WARNING!

LED light

emission. Risk of

eye injury.

WARNING!

Burn hazard. Hot

surface. Do not

touch.

WARNING!

Wear protective

eyewear

.

WARNING!

Refer

 

to

 

user

 

manual

.

Using for the first time

This product is for professional use only. It is not for household use.

This product presents risks of severe injury or death due to fire and burn hazards, electric shock and falls.

Read this manual before installing, powering or servicing the fixture, follow the safety precautions listed  below 

and observe all warnings in this manual and printed on the fixture. If you have questions about how to operate the 

fixture safely, please contact your supplier.

PROTECTION FROM ELECTRIC SHOCK

 

• 

Disconnect the machine from AC power before removing or installing any cover or part  and when not in use

• 

Always ground (earth) the fixture electrically.

• 

Use only a source of AC power that complies with local building and electrical codes and has both overload 

and ground-fault (earth-fault) protection.

• 

Before using the machine check that all power distribution equipment and cables are in perfect condition 

and rated for the current requirements of all connected devices.

• 

Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm² (16 AWG) 

minimum conductor size and an outer cable diameter of 5 - 15 mm . Cables must be hard usage type (SJT 

or equivalent) and heat-resistant to 90° C minimum.

• 

Use only PowerCON® cable connectors to connect to power input sockets. Use only PowerCON®  cable 

connectors to connect to power through put sockets.

• 

Isolate the machine from power immediately if the power plug or any seal, cover, cable, or other component  

is damaged, defective, deformed, wet or showing signs of overheating. Do not reapply power until repairs 

have been completed.

Do not expose the fixture to rain or moisture

CLF EF Smoke 3100 has an IP20 rating, indoor use only.

 


background image

WWW.CLF-LIGHTING.COM

5

Safety Instruction

PROTECTION FROM BURNS AND FIRE

• 

Do not operate the machine if the ambient temperature (Ta) exceeds 45°C.

• 

The exterior of the machine becomes hot during use. Avoid contact by persons and materials. Allow the 

machine to cool for at least 10 minutes before handling.

• 

Keep all combustible materials (e.g. fabric, wood, paper) at least 100 mm  away from the nozzle

• 

Keep flammable materials well away from the machine

• 

Ensure that there is free and unobstructed airflow around the machine

• 

Do not place objects within 200 mm  of the machine

• 

Do not attempt to bypass thermostatic switches or fuses.

• 

If you relay power from one machine to another using power throughput sockets, do not connect more than 

1 machines in total to each other in an interconnected chain.

• 

Connect only other machines to fixture power throughput sockets. Do not connect any other type of device 

to these sockets.

• 

Do not connect any other type of device to these sockets.

• 

Do not stick filters, masks or other materials onto any optical component.

• 

Do not modify the machine in any way not described in this manual 

• 

Do not connect machine to a dimmer

PROTECTION FROM INJURY

• 

Ensure that persons are not looking at the LEDs from within 3 meters when the product lights up suddenly. 

This can happen when power is applied, when the product receives a DMX signal, or when SERVICE menu 

items are selected.

• 

Fasten the fixture securely to a fixed surface or structure when in use. The fixture is not portable when 

installed.

• 

Ensure that any supporting structure and/or hardware used can hold at least 10 times the weight of all the 

devices they support.

• 

Allow enough clearance around the head to ensure that it cannot collide with an object or another fixture 

when it moves.

• 

Check that all external covers and rigging hardware are securely fastened.

• 

Block access below the work area and work from a stable platform whenever installing, servicing or moving 

the machine

• 

Do not operate the machine with missing or damaged covers, shields or any optical component.

 


background image

WWW.CLF-LIGHTING.COM

6

ac power

power voltage

Check  that  the  voltage  range  specified  on  the  machine  serial  number  label  matches  the  local  AC  mains 

power  voltage  before  applying  power  to  the  fixture.  The  machine  accepts  AC  mains  power  at  100-240  V 

nominal,  50/60  Hz.  Do  not  apply  AC  mains  power  to  the  machine  at  any  other  voltage  than  specified.

power cables

Power  input  and  throughput  cables  must  be  rated  20 A  minimum,  have  three  conductors  1.5  mm²  (16 AWG) 

minimum conductor size and an outer cable diameter of 5 - 15 mm. Cables must be hard usage type (SJT or 

equivalent)  and  heat-  resistant  to  90°C  minimum.  In  the  EU  the  cable  must  be  HAR  approved  or  equivalent.

If  you  install  a  power  plug  on  the  power  cable,  install  a  grounding-type  (earthed)  plug  that  is  rated  20 A  mini

-

mum. Follow the plug manufacturer’s instructions. Table 1 shows standard wire color-coding schemes and some 

possible  pin  identification  schemes;  if  pins  are  not  clearly  identified,  or  if  you  have  any  doubts

Wire color (EU models) Wire color (US models) Conductor

Symbol

Screw (US)

Brown

Black

Live

L

Yellow or Brass

Blue

White

Neutral

N

Silver

Yellow / green

Green

Ground (earth)

Green

Table 1: Wire color-coding and power connections

      

or

data link

A DMX 512 data link is required in order to control a machine via DMX. The machine has 3 & 5-pin XLR connectors for DMX data 

input and output. The pin-out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+) Pins 4 and 5 in the 5-pin XLR 

connectors are not used.   

tips for reliable data transmission

To connect the machine to data:

1. 

Connect the DMX data output from the controller to the closest machines male 3 & 5-pin XLR DMX input connector.

2. 

Connect the DMX output of the machine closest to the controller to the DMX input of the next machine and continue       

connecting machines output to input.

 


background image

WWW.CLF-LIGHTING.COM

7

physical installation

Warning! The machine must be either fastened to a flat surface such as a stage or wall, or clamped to a truss or 

similar structure in any orientation using a rigging clamp.

Warning! At all times machine can cause injury or damage it if falls, attach an approved safety cable to one of the

safety cable attachment points on the base (see “machine overview” on page 4).

Check that all surfaces more far aways then a minimum of 200 mm. from the machine, that combustible materials 

(wood, fabric, paper, etc.) are minimum 100 mm. from the nozzle, that there is free airflow around the machine 

and that there are no flammable materials nearby. 

Fastening the machine to a flat surface

The  machine  can  be  fastened  to  a  fixed  flat  surface  that  is  oriented  at  any  angle.  Check  that  the  surface 

can  support  at  least  10  times  the  weight  of  all  machines  and  equipment  to  be  installed  on  it.

Warning! The supporting surface must be flat otherwise the air vents in the base may be blocked, which will cause 

overheating. Fasten the machine securely. Do not place it on a surface or leave it where it can be moved or can fall 

over. Attach a securely anchored safety cable to the safety cable attachment point (see “machine overview” on page.

If the machine is installed in any location where it may fall and cause injury or damage if the primary attachment 

fails:

1. 

Block access under the work area. Working from a stable platform. 

2. 

Secure the machine with a secondary attachment such as an approved safety cable that is rated for the 

weight of the machine using one of the attachment points at the edges of the base (see “machine overview” 

on page 4). Do not use any other part of the machine as a safety cable attachment point.

operating instructions

1. 

After checking that all the parts are intact and complete, position the machine on a flat surface.

2. 

Only use designated CLF Lighting smoke liquid. Machine can be harmed when using other fluids and warranty is expired.

3. 

Connecting the power cord. Before power on, make sure it is connected with the rated voltage.

4. 

Turn on the machine, it will immediately start heating up, the digital display will show “WARMING UP”. 

Menu instruction

1. 

MENU button: When it shows “HEAT”, press “menu” button to enter the page “ADDR”

2. 

UP button: Increase the relevant value of each page 

3. 

DOWN button: Decrease the relevant value of each pag

4. 

ENTER button: Enter or exit each page 

Wireless Controll

When the unit is powered on, and the wireless status is ON, the LCD display will show “wireless setup”. In such case, user can register 

the wireless remote by pressing any button for 1s on the remote. If the LCD display flickers twice, then it is matched with the unit suc

-

cessfully. One unit can match with 5 remotes at most. If user register the sixth one, then the memory for the first five remotes will be 

erased. Press ON button to run the unit or OFF button to stop it. When the machine is under wireless remote control, the haze output 

is the one set by VOLUME OUT. For example, if the VOLUME OUT is 1%, then it will be 1% when controlled by wireless remote. 

Press button A to  run,  release it to stop. The operation of B,C,D is same as button A.

Note:

1. 

When matching the wireless remote, please make sure the LCD display flicker twice. Then release the A  button to  match the 

wireless remote, Otherwise, it might fail. 

2. 

If the wireless remote setup is OFF(i.e. LCD displays “Wireless Set OFF”), when the machine is powered on again, the LCD 

display will not show “wireless setup”.

3. 

Wireless remote control will void if the unit is connected to DMX.

 


background image

WWW.CLF-LIGHTING.COM

8

menu navigation

 

 

 

MENU:  

Scroll through setting menu;

 

 

 

 

UP:  

Increase, multiplex “TIMER” button; 

 

 

 

DOWN:  

Decrease, multiplex “VOLUME” button; 

 

 

 

ENTER:   In/Out, multiplex “stop” button;

Press “ MENU ” button to switch different pages, 10 pages in total:

1. 

Ready To Fog:    

The machine is ready to work

2. 

Interval Set: 

 

To set the interval of timer mode , adjustable from 1~200s

3. 

Duration Set: 

 

To set the duration of timer mode , adjustable from 1~200s

4. 

Channel A from 0-10 

Set the color when triggered by wireless remote controller button A

5. 

Channel B from 0-10 

Set the color when triggered by wireless remote controller button B

6. 

Channel C from 0-10 

Set the color when triggered by wireless remote controller button C

7. 

Channel D from 0-10 

Set the color when triggered by wireless remote controller button D

8. 

DMX512 Address:  

The DMX address can be set up from 1 to 512

9. 

Wireless Set: 

 

To turn on/off the wireless function

10. 

Language: 

 

Select the language saved by “Enter”

When the machine is not working, press “Stop” to Exit. When the machine is working, press “Stop” to stop machine working and 

go back to home page. Press UP or DOWN to change the value in each setting page. At home page, press TIMER button to 

activate timer mode, LCD displays as below:

• 

Interval 10s: Interval countdown

• 

Duration 10s: Duration countdown

 

The two pages will display circularly when each countdown finish, “Interval” and “Duration” time could be set in page 2 and 3. At 

home page, press VOLUME button to activate volume mode, the machine starts to fog

At Channel A page, press ENTER button to LED color setting page. Press UP and DOWN to choose color. Press ENTER to save 

and exit the setting. There are total 11 LED color modes, which are “OFF”, “Co1-Co9” (9 colors) and “random color changing 

(rand)” mode. The color setting of Channel A wil be effected when press button A of the wireless controller.

1. 

When set to OFF, the LED would not light up. 

2. 

9 colors are as following:

• Co 1:  Red  

 

 

• Co 6:  Orange

• Co 2:  Green 

 

 

• Co 7:  Yellow

• Co 3:  Blue 

 

 

• Co 8:  Sky blue

• Co 4:  Pink  

 

 

• Co 9:  White

• Co 5:  Purple

After setting the color, the corresponding color will light up when output controlled by wireless remoter. When Random mode, the 

LED will change color randomly, the interval is 1s.  

 

Note:

  When connected to DMX controller, the color setting from this page will be invalid, the LED color would be controlled by 

DMX controller 

Wireless remote control button 1-4 trigger the options set in the color program CH-1-CH-4, 

 

respectively. DMX When connected DMX controller, the LCD shows DMX address setting page only, to easily set DMX address.

 


background image

WWW.CLF-LIGHTING.COM

9

fluid

dmx channels

Channel

Function

Value

Percentage

Remark

CH 1

FOG output

010 - 255

0 - 100%

000 - 009 = OFF

CH 2

Inner LED red output

010 - 255

0 - 100%

000 - 009 = OFF

CH 3

Inner LED green output

010 - 255

0 - 100%

000 - 009 = OFF

CH 4

Inner LED green output

010 - 255

0 - 100%

000 - 009 = OFF

CH 5

Outer LED red output

010 - 255

0 - 100%

000 - 009 = OFF

CH 6

Outer LED green output

010 - 255

0 - 100%

000 - 009 = OFF

CH 7

Outer LED blue output

010 - 255

0 - 100%

000 - 009 = OFF

CH 8

Color Macro

010 - 255

0 - 100%

000 - 009 = OFF

CH 9

Color Macro speed

010 - 255

0 - 100%

000 - 009 = OFF

CH 10

LED strobe

010 - 255

0 - 100%

000 - 009 = OFF

CH 11

LED dimmer    

010 - 255

0 - 100%

000 - 009 = OFF

          

This machine use electronic program to detect whether there is fluid inside tube or not, hence to protect the pump from being damaged 

when there is no fluid. 

1. 

How to activate “low-fluid protection”. When the and activate it, so when the internal inspection module check out there is no oil 

inside the tube but the machine is still working, then the machine will get into oil free protection 20s later by shutting the pump off. 

The digital display will keep flashing.

2. 

How to release “low-fluid protection”. When the machine is under the protection of low fluid, after refilling the fluid, there are three 

ways to release the protection. 

3. 

Keep pressing the one board red fog button until the fog liquid fill the tube completely, then the machine would exit low-fluid 

protection.

4. 

Under the wireless remote control, keep pressing any buttons until the fog liquid fill the tube 

 

completely, then the machine would exit low-fluid protection.

5. 

Under the DMX control, firstly push the slider of channel one to the value below 10(Fog OFF),then push the slider up to value 

above 10(Fog ON), the machine would exit low-fluid protection by doing so. 

Note:

 When the machine is heating up. HEAT page is prior to ADDR and all the other pages. Without connecting with DMX, the digital 

display will back to page ADDR automatically.

 


background image

WWW.CLF-LIGHTING.COM

10

maintenance

Oil injection trouble: 

Refers to the fog fluid atomizing in the heater pipe of the machine is not good, heater temperature cannot be timely and effective transmit 

to the fog fluid, fog fluid cannot  all atomization and lead to oil injection.

1. 

Using the low quality or counterfeit fog fluid, low quality fog fluid have more impurities, easy to adhere to the pipe wall and hindered 

temperature transmission result in incomplete atomization caused oil injection.

2. 

Using an incorrect fog fluid. Different fog fluid have different required atomization temperature. If you use the wrong fog fluid result in 

oil cannot fully atomization caused oil injection.(fig 1)

Heater blocking trouble:

Poor atomization oil injection is the early signs of heater block.   Using poor quality fog fluid or not timely maintenance cleaning the fog 

machine for a long time. Inevitable will appear the terminal symptom of heater blocking.

1. 

heater blocked is because used inferior fog fluid or not maintenance for a long time. Have nothing to do with the quality of machine. 

Like a car with poor quality gasoline produce poor oil circuit failure or long-time no maintenance the car will inevitably appear bigger 

problems. (fig 2)

Solutions to these problems:

Fog machine heating pipes used for a long time and then the pipe wall will easily produce sediments (The more inferior fog fluid the more 

impurities thus lead to oil injection or blocked). All fog machines need regular maintenance (fog machine maintenance cycle for 1 to 2 

months/time). 

 

Specific maintenance method: after heating the 35% white vinegar plus 65%  distilled water and then spray 10 to 15 times.

Conclusion: 

As long as the fog machine with oil injection or heater blocking after using a period of time.  It was caused by fog fluid quality or lack of 

maintenance,  has nothing to do with the quality of the machine. Please use the original high quality fog fluid and timely maintain it, then it 

can be used for a long time

 


background image

WWW.CLF-LIGHTING.COM

11

specifications

Power

3100W

LED

LED bottom smoke: 9 PCS RGB

LED top smoke: 23 PCS RGB

Voltage / frequency

AC100V - 240V - 50/60Hz

Fuse

15A/250V

Power consumption; 

all effects static, zero light output

<25W

AC power input

PowerCON

DMX data in/out

5 pin & 3 pin locking XLR

Netto weight 

16kg

Size

475x401x205mm

Control

DMX & Wireless 

Channel

11 channels

Output

54000CUFT/MIN (max 10m height and max 8 sec)

Settings and addressing

Control panel with backlit LED graphic display

Protocol

USITT DMX512-A & Wireless

Color

Black

Housing

High strenght die-casting aluminium and metal

Protection rating

IP20

Orientation

Up and downwards (when fuel tank is rotated)

Min. distance to combustable materials

100mm from machine

Min. distance to iluminated surfaces

200mm from machine

Wireless remote

4 button remote

Fluid consumption

3,7min/L

Fluid capacity

2,5L

Fluid brand

CLF Fog fluid

Heat up time

4 min

Max. ambient temperature (Ta max)

45°C

 

 


background image