Full Text Searchable PDF User Manual

1
CLF Colour Par 12
CLF Colour Par 12
CLF Colour Par 12
CLF Manuals
CLF Manuals
Version 1.0 November 2012
Version 1.0 November 2012

2
1.BEFORE YOU BEGIN
What is included
Ø
1 x Fixture
Ø
1 x Power cable with plug
Ø
1 x User Manua
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton; check the
contents to ensure that all parts are present, and have been received in good
condition. Notify the shipper immediately and retain packing material for
inspection if any parts appear damaged from shipping or the carton itself shows
signs of mishandling. Save the carton and all packing materials. In the event that
a fixture must be returned to the factory, it is important that the fixture be returned
in the original factory box and packing.
AC POWER
This fixture has an auto-switching switch-mode power supply that can
accommodate a wide range of input voltages. The only thing necessary to do
before powering on the unit is to make sure the line voltage you are applying is
within the range of accepted voltages. This fixture will accommodate between
100V and 240V AC 50-60 Hz. Each light is connected end to end by the power
socket
“
POWER IN
”
and
“
POWER OUT
”
on the light,
Help preserve the environment! Ensure that this product is
recycled at the end of its life. Your supplier can give details
of local arrangements for the disposal of products.

3
Safety Instructions
!
WARNING!
Please read these instructions carefully, which includes
important information about the installation, usage and
maintenance of this product..
The following symbols are used to identify important safety information on the
product and in this manual:
!
!
DANGER!
Safety hazard.
Risk of severe
injury or death
DANGER!
Hazardous
Voltage. Risk of
lethal or severe
electric shock.
WARNING!
Fire hazard
WARNING!
LED light
emission. Risk
of eye injury.
WARNING!
Refer to user
=
This light belongs to grade I protection device, therefore the light must connect
to the earth excellently. And the power connection must be operated by the
professional technician.
=
Make sure that the working voltage will not higher or lower than the rated value.
=
Make sure that the cable didn't be damage or lacerated by sharp.
=
The light must be power off when it's standing idle or before clearing.
=
The cable must with plug, and you must pull out the cable by handle the plug.
=
Please be careful when installing the lighting. Never touch the bared cable, or
it will cause the deadly electric shock.
=
Please use the suitable and safe cable to connect the light.
=
Please never remodel the light randomly, we will not take the guarantee for the
faulty and damage which caused by dismantle
repair or remodel of the
nonprofessional person.
=
Maximum ambient temperature 40
°
C. Do not operate fixture at temperatures
higher than this.
=
Never connect the device to a dimmer pack.
=
Do not daisy chain power to more than 8 units @ 120V and 15 units @ 230V.

4
2.INTRODUCTION
Specifications
l
Voltage Rating: AC100V
240V 50-60Hz
l
Power Rating:50W
l
LED Quantity: 12 pcs 3 in 1 LEDs(RGB)
l
LED: 400mA
l
Beam Angle: 20
°/
30
°
/40
°
l
Ingress Protection: Ip20
l
Product Size: 295x 195 x255mm
l
Package Size: 350x260x320 mm
l
N/W:4.6Kg
l
G/W:5.6Kg
Features
l
RGB color mixing with or without DMX controller
l
5 distinct dimming curves
l
LED display with password protection
l
Operating Modes: DMX512 Connection /Master & Slave...
l
DMX Channels: 03CH/04CH/05CH/06CH
06 channels: Dimmer+RGB+Macro &AUTO + strobe
05 channels:RGB +Dimmer+ strobe
04 channels:RGB +Dimmer
03 channels:RGB

5
Product Overview
Hanging
bracket/ floor
stand
Bracket
adjustment
knob
Power in
Power out
DMX IN
DMX OUT
Control board
Dimensions

6
3.SETUP
Installation Requirement
l
This product can be used in a variety of situations, can hang and put on
the ground.
l
If hanging the fixture for over head use, then please follow the below steps.
l
Please choose the suitable location to put or hang the light when installing it.
You must use the exclusive clamp hanger and screw when hanging it, and
make sure the weight of the light is within limits of the hanger.
l
Please make sure without any flammable objects within 0.5m when
installing the light.
l
The installation should be operated by professional person; any irregular
installation will cause the body injury or equipment damage.
l
Block access below the work area and use suitable and stable platform
when installing or servicing fixture.
Hanging Clamp
Note: sold
separately
Safety Cable
Note: the cable must be
secured through the heat
sink ventilation
passageway.

7
Connection of DMX Signal Wire
1
Please use the fixture controller wire specially when use the DMX512
Controller. Connect the (male) 3 pin connector side of the DMX cable to
the output (female) 3 pin connector of the first fixture.
2
Connect the end of the cable coming from the first fixture which will have
a (male) 3 pin connector to the input connector of the next fixture
consisting of a (female) 3 pin connector. Then, proceed to connect from
the output as stated above to the input of the following fixture and so on.
3
This product can be connected numerous lamps in series without the
need for the signal amplifier; the signal will not be weakened.
DMX IN
DMXOUT
DMX IN
DMXOUT
DMX IN
DMXOUT
3-PIN TO 5-PIN CONVERSION CHART
Note! If you use a controller with a 5 pin DMX output connector, you will
need to use a 5 pin to 3 pin adapter.
Conductor
Ground/Shield
Data ( - ) signal
Data ( + ) signal
Do not use
Do not use
3 Pin Female
(output)
Pin 1
Pin2
Pin 3
5 Pin Male (Input)
Pin 1
Pin2
Pin 3
Do not use
Do not use
3 PIN TO 5 PIN CONVERSION CHART

BUTTON
MENU
DOWN
UP
ENTER
FUNCTION
Exits from the current menu or function
Navigates downwards through the menu list and decreases the numeric
value when in a function
Navigates upwards through the menu list and increases the numeric
value when in a function
Enables the currently displayed menu or sets the currently selected
value in to the selected function
4.OPERATING INSTRUCTIONS
Control Panel Functions
8
MENU

9
OFF
DIM(1-4)
Password
V402
RED
GRED
BLUE
STRB
TIME
FADE
ON
30S
PR00
01~09
custom
SC00
01~30
scene
Pr10
custom
SC00
01~90
scene
MAIN
FUNCTION
STAT
AUTO
DMX
RUN
PERS
SET
EDIT
DISP
SUB-
FUNCTION
D000
R000
G000
B000
S000
At00
Pr00
DMX
SLAV
03CH
04CH
05CH
06CH
DIM
REST
VER
SELECTION
000~255
(0 ~ 100%)
00~20
01~10
01~10
001 ~ 512
INSTRUCTION
User can combine RED, GREEN and
BLUE to generate a custom color
Select strobe frequency
10 auto programs available
chose program from 10
“
EDIT
”
Set DMX start address
Sets the operating mode for the fixture:to
receive signal from a DMX controller
(DMX) .receive signal or Download
programs from Master fixture. (Slave)
03 channels
RGB
04 channels
Dimmer+RGB
05 channels
Dimmer+RGB+ Strobe
06 channels
Dimmer+RGB...
"Off" means select linear dimming, or
choose dimmer 1-4 to control the dimming
speed, dimming 1 of the fastest dimming
curves, 4 for the most slowly dimming curve
Reset factory defaults
Version number
User can combine RED, GREEN, and
BLUE to generate a custom color
(0~20Hz)Select strobe frequency
(0~255) step time
transition time of last step to current step
Display is always on
Display switches off and goes into
Sleep mode if the controls have not
been pressed for 30 seconds
Menu Map

10
Operating instructions
1 Factory reset
SET
Ü
REST
Ü
{UP
UP
DOWN
DOWN}
Ü
{ENTER}
Note: The password is permanently set as {UP UP
DOWN
DOWN}
Then press ENTER button
1 Custom program
EDIT
Ü
PR01
Ü
PSC01
1
Press
MENU
button until
EDIT
is displayed, press ENTER access program mode.
2
Select the program you'll edit by pressing UP/DOWN buttons. The available
range is o1-10.
3
Select the step you'll edit by pressing UP/DOWN buttons, and then press
ENTER button access program.
When 'R000' display on the screen, press the UP/DOWN button to choose the value.
Repeat this step to edit the value of 'G000', 'b000', 'S000', 'T000' and 'F000'.
Please pay attention for the 'S' is the rate of strobe. 'T' is the operating time of the
present step, the value is between 0 to 255. 'F' is the transitional time from previous
step to present step. The transitional time is the quickest when the FADE is 0.
Notice: Please operate the program in turn, from the 01st step to the 30th step.
When the operating program less than 30 steps, please set the final step value be 0
4
Repeat step 3 till complete programming.
5
Exit program mode by pressing
MENU
buttons three times.
DMX512 Controller Mode
1
Setting DMX512 Address
DMX
Ü
001--512
Access control panel function by pressing
MENU
until
DMX
is displayed.
Press ENTER, add or reduce channels by pressing UP/DOWN between 001 and 512.
Press
MENU
to exit.
2
Setting Channels
PERS
Ü
03CH
04CH
05CH
06CH
Access control panel function by prekssing MODE until
PERS
is displayed.

11
Channel
1
Dimming
2
RED
3
Green
4
Blue
5
Macro color
control& atuo
Value
000~255
000~255
000~255
000~255
0-4
5
6-19
20-24
25-49
50-59
60
61-74
75
76-84
85-89
90-94
95-99
100-104
105-109
110-114
115-119
120-124
125-129
130-134
135-139
140-144
145-149
150-154
155-159
160-164
Description
0-100%
0-100%(Or STEP TIME when CUS.01-10 is activated)
0-10 0%(Or FADE TIME when CUS.01-10 is activated)
0-100%
No Function
BLUE 100%,RED90
,GREEN97
,
BLUE100%
RED &GREEN DOWN
Purple (BLUE100%
RED UP)
Red (RED100%
BLUE DOWN)
Yellow (RED100%
GREEN UP )
Lime(GREEN100%
BLUE80%
RED78%)
Green (GREEN100%
RED & blue DOWN )
Teal (GREEN 10%
BLUE 10%)
Cyan (GREEN UP BLUE UP)
Colour Scroll Snap Speed 1 (Fastest)
Colour Scroll Snap Speed 2
Colour Scroll Snap Speed 3
Colour Scroll Snap Speed 4
Colour Scroll Snap Speed 5
Colour Scroll Snap Speed 6
Colour Scroll Snap Speed 7
Colour Scroll Snap Speed 8
Colour Scroll Snap Speed 9
Colour Scroll Snap Speed 10
Colour Scroll Snap Speed 11
Colour Scroll Snap Speed 12
Colour Scroll Snap Speed 13
Colour Scroll Snap Speed 14
Colour Scroll Snap Speed 15
Colour Scroll Snap Speed 16
06 channels
06 channels

12
Channel
5
Macro color
control& atuo
6
Strobe
Value
165-169
170-174
175-179
180-184
185-189
190-194
195-199
200-204
205-209
210-214
215-219
220-224
225-229
230-234
235-239
240-244
245-249
250-255
000-255
Description
Colour Scroll Snap Speed 17 (Slowest)
Colour Scroll FADE Speed 1 (Fastest)
Colour Scroll FADE Speed 2
Colour Scroll FADE Speed 3
Colour Scroll FADE Speed 4
Colour Scroll FADE Speed 5
Colour Scroll FADE Speed 6
Colour Scroll FADE Speed 7
Colour Scroll FADE Speed 8
Colour Scroll FADE Speed 9
Colour Scroll FADE Speed 10
Colour Scroll FADE Speed 11
Colour Scroll FADE Speed 12
Colour Scroll FADE Speed 13
Colour Scroll FADE Speed 14
Colour Scroll FADE Speed 15
Colour Scroll FADE Speed 16
Colour Scroll FADE Speed 17 (Slowest)
Strobe(00~20Hz)
05 channels
Channel
1
2
3
4
5
Value
000~255
000~255
000~255
000~255
000~255
Description
Red
Green
Blue
Dimming
Strobe(00~20Hz)

13
04 channels
Channel
1
2
3
4
Value
000~255
000~255
000~255
000~255
Description
Red
Green
Blue
Dimming
03 channels
Channel
1
2
3
Value
000~255
000~255
000~255
Description
Red
Green
Blue
Master/Slave Control Mode
1
Setting master machine
Acc
ess control panel function by pressing
MENU
until
AUTO
is displayed.
Press ENTER, select
ATXX
OR
PRXX
by pressing UP/DOWN buttons.
Press ENTER, and then press
MENU
to exit.
You can choose
ATXX
pre-set programs, the range is
o1--10
.
you can choose
PRXX
custom programs, the range is
o1--10
2
Setting slave machine
Access contro
l panel function by pressing
MENU
until
RUN
is displayed.
Press ENTER, press UP/DOWN buttons until the
SLAV
is displayed.
Press
MENU
return to MENU
3
Usage of Master/Slave
When two
or more fixtures connected, you can set up the first machine as the
Master and the followed fixtures as Slaves. The Master can choose pre-set programs ...
ATXX
OR
PRXX
, all the slaves will follow the Master's operation synchronously.

14
Symptom(s)
1 or more LED's are
not illuminating
Breaker/Fuse keeps
blowing
Device has no power
Fixture is not
responding to DMX
Loss of signal
Possible Solution(s)
Clean the fixture regularly to avoid any such failure. This fixture is
convection cooled, which means that if the surface is kept clean
and free of debris, then proper cooling will be allowed to occur
An LED may have failed, resulting in an open circuit. In this event,
all of the red, green, or blue in a single module will no longer
illuminate. This does not mean that all of the LEDs have failed,
but the circuit is wired in series.
An LED may have failed, resulting in a short circuit. In this event, only
the single LED which has failed will no longer function. This does not
mean that all of the LEDs have failed, but the circuit is wired in series.
-Note: In the event of LED failure, a replacement LED PCB
assembly may be purchased directly from Our company
Check total load placed on the electrical circuit
Check for a short in the electrical wiring: internal and/or external
Check for power on Mains
-Note: In the event of autoswitching transformer failure, the unit
can be sent in for repair; however, a replacement part can be
ordered directly from Our company
Check Control Panel settings for correct addressing
Check DMX cables
Check polarity switch settings on the controller
Check cable connections
Call service technician
-Note: In the event of Display PCB failure, a replacement PCB
can be ordered directly from Our company
Use only DMX cables
Install terminator
Note: Keep DMX cables separated from power cables or black
lights
5. APPENDIX
Service Maintenance Guide

15
Symptom(s)
COLOR-CON
Controller does not
function, or does not
function properly
Stand alone
operation
Possible Solution(s)
Make sure connector is firmly connected to device
This fixture must be in the correct mode in order to properly
respond to the COLOR-CON controller. The correct mode is
“DMX”
in the onboard Control Panel
This fixture has built-in, automatic programs that may be
triggered from the onboard Control Board

16
1
2
3
4
5
6
7
8
9
10
11
Description
Glass cover
LED Lens assembly
LED Metal-core PCB assembly
Power supply seat
XLR seat
LED Driver Board
House
Bracket Assembly
Bracket adjustment metal knob
Display PCB assembly
Electronic Transformer
Part Number
6P00118
6P00105
2P00106
5100103
5100102
2P00107
6P00118
5120117
5020105
2P00103
5080125
Blow-out Diagram.