Full Text Searchable PDF User Manual

CLF ARES
LEDWASH
V1.0 December 2015

Dimensions
All dimensions
are
in
millimeters
2

Safety Information
The
following
symbols
are
used
to
identify
important
safety
information
on
the
product
and
in
this
manual
:
WARNING!
Read the safety precautions in this section before
installing, powering, operating or servicing this
product
DANGER!
Safety hazard.
Risk of severe
injury or death.
DANGER!
Hazardous
voltage. Risk of
lethal or severe
electric shock.
WARNING!
Fire hazard.
WARNING!
LED light
emission. Risk of
eye injury.
WARNING!
Burn hazard. Hot
surface. Do not
touch.
WARNING!
Wear protective
eyewear
.
WARNING!
Refer
to
user
manual
.
Warning! Risk Group 3 (high risk) LED product according to EN 62471. Do not look into the beam at a distance
of less than 8.3 meters from the front surface of the product. Do not view the light output with optical
instruments or any device that may concentrate the beam.
l
l
Always ground (earth) the fixture electrically.
l
Use only a source of AC power that complies with local building and electrical codes and has both overload and
ground-fault (earth-fault) protection.
l
Before using the fixture, check that all power distribution equipment and cables are in perfect condition and rated for
the current requirements of all connected devices.
l
Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm² (16 AWG) minimum
conductor size and an outer cable diameter of 5 - 15 mm. Cables must be hard usage type (SJT or equivalent) and
heat-resistant to 90° C minimum.
l
Use only PowerCon true cable connectors to connect to power input sockets. Use only PowerCon true
cable
connectors to connect to power throughout sockets.
l
Isolate the fixture from power immediately if the power plug or any seal, cover, cable, or other component is
damaged, defective, deformed, wet or showing signs of overheating. Do not reapply power until repairs have been
completed.
This
product
is
for
professional
use
only
.
It
is
not
for
household use
.
This
product
presents
risks
of
severe
injury
or
death
due to fire and burn
hazards
,
electric
shock
and
falls
.
Read this manual before
installing
,
powering
or
servicing
the fixture
,
follow the
safety
precautions
listed
below
and
observe
all
warnings in this manual
and printed on the fixture
.
If you
have
questions
about
how
to
operate the
fixture
safely
,
please
contact
your
supplier
PROTECTION
FROM
ELECTRIC
SHOCK
Disconnect the fixture from AC power before removing or installing any cover or part and when not in use.
3

l
Do not expose the fixture to rain or moisture.
l
Refer any service operation not described in this manual to a qualified technician.
l
Socket outlets used to supply fixture fixtures with power or external power switches must be located near the fixtures
and easily accessible so that the fixtures can easily be disconnected from power.
l
Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C .
l
The exterior of the fixture becomes hot during use. Avoid contact by persons and materials. Allow the fixture to
cool for at least 10 minutes before handling.
l
Keep all combustible materials (e.g. fabric, wood, paper) at least 100 mm away from the head.
l
Keep flammable materials well away from the fixture.
l
Ensure that there is free and unobstructed airflow around the fixture.
l
Do not illuminate surfaces within 200 mm of the fixture.
l
Do not attempt to bypass thermostatic switches or fuses.
l
If you relay power from one fixture to another using power throughout sockets, do not connect more than five fixtures
in interconnected chain.
l
Do not stick filters, masks or other materials onto any optical component.
l
Do not modify the fixture in any way not described in this manual
l
Do not look continuously at LEDs from a distance of less than 8.3 meters from the front surface of the fixture without
protective eyewear such as shade 4-5 welding goggles. At less than this distance, the LED emission can cause eye
injury or irritation. At distances of 8.3 meters and above, light output is harmless to the naked eye provided that the
eye’s natural aversion response is not overcome.
l
Do not look at LEDs with magnifiers, telescopes, binoculars or similar optical instruments that may concentrate
the
light
output
.
l
Ensure that persons are not looking at the LEDs from within 8.3 meters when the product lights
up
suddenly
.
This
can
happen
when
power
is
applied
,
when
the
product
receives
a
DMX signal
,
or when
SERVICE menu
items
are
selected
.
l
Fasten the fixture securely to a fixed surface or structure when in use. The fixture is not portable when installed.
l
Ensure that any supporting structure and/or hardware used can hold at least 10 times the weight of all the devices they
support.
l
Allow enough clearance around the head to ensure that it cannot collide with an object or another fixture when
it moves.
l
Check that all external covers and rigging hardware are securely fastened.
l
Block access below the work area and work from a stable platform whenever installing, servicing or moving
the fixture.
l
Do not operate the fixture with missing or damaged covers, shields or any optical component.
PROTECTION
FROM
BURNS
AND
FIRE
PROTECTION
FROM
INJURY
4

Contents
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Fixture overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Using for the first time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Power voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Power cables and power plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Data link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Connecting the data link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Tips for reliable data transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
DMX protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Onboard control menus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Control panel and menu navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DMX address setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
WDMX control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Control mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Dimming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Enable passwork lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Restoring factory default settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5
5

Fixture overview
6
Safety
cable
attachment
point
Display
DMX
input
AC mains power
input
G Clamp with
Quicklock # 875760
(Optional)
AC
mains
power
through
DMX
output
Antenna
Wireless
S
olutions

Introduction
Warning! Read “Safety Information” on page 3 before installing, powering, operating or servicing the
fixture. Before applying power to the fixture:
.
l
Carefully review “Safety Information” starting on page 3.
l
Check that the local AC mains power source is within the fixture’s power voltage and frequency ranges.
l
See “Power cables and power plug” on page 8. Install a PowerCon input connector on a suitable power
cable. If drawing power from a mains power outlet, install a suitable power plug on the power cable.
Using for the first time
7
l
This CLF Ares fixture features:
l
RGBW color control with color temperature control
l
‘Color wheel’ color
l
Onboard control panel and backlit LCD graphic display
l
Smooth electronic dimming
l
Electronic shutter with strobe and pulse effects
l
Calibrated and raw modes
l
Each line can be control independently
=
Refresh frequency 600/1200/2400/4800 adjustable
l
Wireless DMX multimode(2.4GHz) by Wireless Solution Sweden
=
Master, Slave Function
=
XLR 3-pole DMX standard sockets

AC
power
Warning Read
“
Safety
Information
”
starting
on
page
3
before
connecting
the
fixrures to
AC
mains power
.
Warning!
For
protection
from
electric
shock
,
the
fixture
must
be
grounded
(
earthed
).
The powerdistribution
circuit
must
be
equipped
with
a
fuse
or
circuit
breaker
and
ground
-
fault
(
earth
-
fault
)
protection
.
Warning!
Socket
outlets
or
external
power
switches
used
to
supply
the
fixture
with
power
must
be located
near
the
fixture
and
easily
accessible
so
that
the
fixtures
can
easily
be
disconnected
from power
.
Important! Do
not
insert
or
remove
live
PowerCon
connectors
to
apply
or
cut
power
,
as
this may
cause
arcing
at
the
terminals
that
will
damage
the
connectors
.
Important!
Do
not
use
an
external
dimming
system
to
supply
power
to
the
fixture
,
as
this may cause
damage
to
the
fixture
that
is
not
covered
by
the
product
warranty
.
The
can be hard-wired to a building electrical installation if you want to install it permanently, or a power plug that is
suitable for the local power outlets can be installed on the power cable.
,
Warning!
Check
that
the
voltage
range
specified
on
the
fixture s
serial
number
label matches
the
local
AC
mains
power
voltage
before
applying
power
to
the
fixture
.
The fixtures accept AC mains power at 100-240 V nominal, 50/60 Hz. Do not apply AC mains power to the fixture at any
other voltage than that specified on the fixture’s serial number label.
Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm² (16 AWG) minimum
conductor size and an outer cable diameter of 5 - 15 mm. Cables must be hard usage type (SJT or equivalent) and heat-
resistant to 90° C minimum. In the EU the cable must be HAR approved or equivalent.
If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated 20 A minimum. Follow
the plug manufacturer’s instructions. Table 1 shows standard wire color-coding schemes and some possible pin
identification schemes; if pins are not clearly identified, or if you have any doubts
!
fixture
Power voltage
8
Wire Color
(
EU models
)
Wire
Color
(
US models
)
Conductor
Symbol
Screw
(
US
)
brown
black
live
L
yellow or brass
blue
white
neutral
N
silver
yellow
/
green
green
ground
(
earth
)
or
green
Table
1
:
Wire
color
-
codig and power
connections
Power cables and power plug

Data
link
A DMX 512 data link is required in order to control a fixture via DMX.
The fixture has 3-pin XLR connectors for DMX data input and output. The pin-out on all connectors is pin 1 = shield,
pin 2 = cold (-), and pin 3 = hot (+).
Or the fixture has 5-pin XLR connectors for DMX data input and output. The pin-out on all connectors is
pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+). Pins 4 and 5 in the 5-pin XLR connectors are not used
Use shielded twisted-pair cable designed for RS-485 devices: standard microphone cable cannot transmit control data
reliably over long runs. 24 AWG cable is suitable for runs up to 300 meters. Heavier gauge cable and/or an amplifier is
recommended for longer runs.
To
connect
the
fixture
to
data
:
1
.
Connect
the
DMX
data
output
from
the
controller
to
the
closest
fixture’s
male
3
-
pin
XLR
DMX
input connector
.
2
.
Connect
the
DMX
output
of
the
fixture
closest
to
the
controller
to
the
DMX
input
of
the
next
fixture
and continue
connecting
fixtures
output
to
input
.
Tips for reliable data transmission
Connecting the data link
9

DMX protocols
21CH
1
2
3
16CH
27CH
1
2
3
30CH
1
2
3
11CH
1
2
3
4CH 9CH
1
2
3
10
DMX Value
0 - 19
20 - 24
25 - 64
65 - 69
70 - 84
85 - 89
90 - 104
105 - 109
110 - 124
125 - 129
130 - 144
145 - 149
150 - 164
165 - 169
170 - 184
185 - 189
190 - 204
205 - 209
210 - 224
225 - 229
230 - 244
245 - 255
0 - 255
0 - 39
40-44
45-49
50-54
55-59
60-64
65-69
70-74
75-89
90 - 94
95 - 99
100 - 104
105 - 109
110 - 114
115 - 119
120 - 124
125 - 129
130 - 134
135 - 139
140 - 144
145 - 149
150 - 154
155 - 159
160 - 164
165 - 169
170 - 174
175 - 179
180 - 239
240 - 244
245 - 249
250 - 255
Function
Electronic
shutter
effect
Shutter
closed
Shutter
open
Strobe
1
(
fast
→
slow
)
Shutter
open
Strobe
2
:
opening
pulse
fast
→
slow
Shutter
open
Strobe
3
:
closing
pulse
(
fast
→
slow
)
Shutter
open
Strobe
4
:
random
strobe
(
fast
→
slow
)
Shutter
open
Strobe
5
:
random
opening
pulse
(
fast
→
slow
)
Shutter
open
Strobe
6
:
random
closing
pulse
(
fast
→
slow
)
Shutter
open
Strobe
7
:
burst
pulse
(
fast
→
slow
)
Shutter
open
Strobe
8
:
random
burst
pulse
(
fast
→
slow
)
Shutter
open
Strobe
9
:
sine
wave
(
fast
→
slow
)
Shutter
open
Strobe
10
:
burst
(
fast
→
slow
)
Shutter
open
Dimmer
0
-
100
%
intensity
Fixture
control
settings
No
function
1
SILENT MODE (level 1)-70% fan speed
1
SILENT MODE (level 2)-40% fan speed
1
SILENT MODE (level 3)-20% fan speed
No
function
1
Fan mode FULL
1
Fan mode REGULATED
1
Fan mode SILENT
No
function
1
Calibrated color output mode- COLOR CALIB = ON
1
output mode -
= ON
1
Raw color output mode- COLOR CALIB = OFF
No
function
1
Normal dimming, speed of changes unrestricted
No
function
1
Smooth dimming, speed of changes restricted slightly
No
function
600 Hz Refresh rate
1200Hz Refresh rate
2400Hz Refresh rate
4800Hz Refresh rate
No Function
1
WDMX - ON
No Function
1
WDMX - OFF
No Function
1
WDMX - RESET
No Function
2
DMX
No Function
illuminate display
1 Value must be held for 3 seconds to activate.
2
Please
refer
the page
of
15
.(
calibrate
by DMX control)
Value must be held for 3 seconds to activate.
(
)
Manual
calibration
Manual
calibration
Manual
calibration
mode

11
21CH
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
16CH
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
27CH
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
30CH
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
11CH
4
5
6
7
8
9
10
11
4CH
1
2
3
4
9CH
4
5
6
7
8
9
DMX Value
000 - 009
010 - 255
000 - 255
000 - 255
000 - 255
000 - 255
000 - 009
010 - 255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
000-255
0-9
10-19
20-29
......
180-189
190-199
200-255
Function
No Function
Color
wheel
rotation
effect
Red(0-100%)
Green(0-100%)
Blue(0-100%)
White(0-100%)
No Function
Color temperature(2500K-10000K)
LED block 1 dimmer
LED block 1 -Red 1(0-100%)
LED block 1 -Green 1(0-100%)
LED block 1 -Blue 1(0-100%)
LED block 1 -White 1(0-100%)
LED block 1 -Fade(dimmer speed)
LED block 2 dimmer
LED block 2 -Red 2(0-100%)
LED block 2 -Green 2(0-100%)
LED block 2 -Blue 2(0-100%)
LED block 2 -White 2(0-100%)
LED block 2 -Fade(dimmer speed)
LED block 3 dimmer
LED block 3 -Red 3(0-100%)
LED block 3 -Green 3(0-100%)
LED block 3 -Blue 3(0-100%)
LED block 3 -White 3(0-100%)
LED block 3 -Fade(dimmer speed)
LED block 4 dimmer
LED block 4 -Red 4(0-100%)
LED block 4 -Green 4(0-100%)
LED block 4 -Blue 4(0-100%)
LED block 4 -White 4(0-100%)
LED block 4 -Fade(dimmer speed)
NO Function
AUTO 1
AUTO 2
......
AUTO 18
AUTO 19
NO Function
AUTO Speed or Dimmer Speed
AUTO cycle
AUTO speed

12
Onboard control menus
Menu
Item
Options
Notes
(
Default
setting
s
in
bold
)
DMX
ADDRESS
CONTROL
MODE
1-XXX
21CH
4CH
9CH
11CH
16CH
27CH
30CH
0-255
0-255
0-255
0-255
0-255
(0-20)
REGULATED
SILENT Level(1-3)
FULL
High
Normal
NORMAL
SMOOTH
ON/OFF
ON
OFF
RESET
NO CALIBRATION
MANUAL
FACTORYON
600/1200/2400/4800
Level(1-10)
DMX HOLD
NO DMX HOLD
VXXX
TOTAL
XXXX
RESET Reset OK
XXX
℃
0-255
0-255
0-255
Set DMX start address
Select 21/04/09/11/16/27/30 channel setting
(0~20Hz)Select strobe frequency
Enables or Disables password
Color calibration mode off.
Manual
calibration
m
ode
,
R
GBW
t
o
w
hite
i
s
c
ustom
c
alibration
Factory
calibration
m
ode
,
R
GBW
t
o
w
hite
i
s
F
actory
c
alibration
Select the refresh frequency
Set
the
LCD
display
brightness
The
fixture
w
ill
s
tay
t
he
l
ast
value
s
w
hen
y
ou
d
isconnect DMX
The
fixture
h
as
n
o
o
utput
w
hen
y
ou
d
isconnect DMX
Auto programs
Auto speed
Manual
calibration
m
ode
,
R
GB
t
o
w
hite
i
s
c
ustom
c
alibration,(
require password)
0~100%
0~100%
0~100%
0~100%
0~100%
single
leds or two
color mixing
in
full
power
with
120%
output
protection
Turn on the Wireless Board
Turn off the Wireless Board
Reset the Wireless Board
CPU firmware version
USE of time
Use time reset(password)
LED
board
current
temperature
Return all settings to factory defaults
Cooling
fan
speed
regulated
three
level
o
f
s
ilent
m
ode
t
o
c
ontrol
t
he
o
utput
Max
.
cooling
fan
speed
Normal
mode
o
utput
Normal
dimming
with normal
speed
Smooth
dimming
with
slow
speed
STATIC COLOR
Dimmer
FANS
LED POWER
Dimmer speed
KEY-Lock
W-DMX
CALIBRATION
Refresh rate
LCD brightness
DMX HOLD
AUTO(1-20)
Speed(0-20)
Software type
Usage time
Temperature
LOAD
Red
Green
Blue
Red
Green
Blue
White
Strobe
PERSONALITY
INFO
MANUAL CALIB
FACTORY SET
AUTO

13
Setup
The onboard control panel and backlit graphic display are used to set the
's DMX address,
configure individual fixture settings (personality), read out data and execute service utilities. See “Onboard
control menus” on page 12 for a complete list of menus and commands.
Using the control buttons
l
To enter a menu, select a function or apply a selection, press
(Enter).
l
Press (Up) and
(Down) to scroll within a menu or adjust values.
l
To escape a function or move back one level in the menu structure, press
(MODE).
l
The DMX address is configured using the DMX ADDRESS menu in the control panel.
Press
the
button
“
UP”
to
switch
off
Wireless
DMX
or
disconnect
with
all
connected
Transmitters
.
Press
the
button
“
DOWN'
to
set
the
unit
in
the
”ready
to
connect
with
all
not
connected
transmitters'
mode
.
If
you
press
the
mode
button
on
the
Wireless
solution
transmitter
all
the
ready
to
connect
units
will
be
connected
.
If
the
unit
is
successfully
connected
in
the
home
display
the
sign
“
”
.
Appears
.
If
the
unit
is
not
connected
to
a
transmitter
in
the
home
display
the
sign
“
”
.
If
the
unit
switched
off
in
the
home
display
the
sign
“
”
.
The Wireless Board will reset.
fixture
►
▲
▼
◄
Holding down the "UP" and "DOWN" button for more than 3 seconds, the MENU display rotated 180°
l
In order to facilitate for inspection the signal, If the display to flicker when it's not receiving any DMX
signal
l
Holding the
MENU
and
ENTER
button for more than 3 seconds,
Control panel and menu navigation
DMX address setting
WDMX control
: V
:OFF
: X

l
is the default setting. It gives a virtually instantaneous reaction when you dim from one intensity to another
,
but
dimming
slowly
from
one
intensity
to
another
may
appear
slightly
uneven
.
l
The
SMOOTH
setting gives smoother dimming during slow changes in intensity, but it limits the speed of dimming
changes
slightly
.
This
makes
it
ideal
for
slow
,
smooth
dimming
,
but
a
short
time
-
lag
may
be noticeable
if
you
try
to
dim
quickly
from
one
intensity
to
another
.
NORMAL
The
fixture
factory
default
settings
can
be
restored
by
applying
a
FACTORY
SETTING
→
LOAD
command
.
Restoring factory default settings
Standard
Manual
DMX
control
mode
is
selected
in
the
CONTROL
MODE
menu
.
The
fixture
has
five
DMX
control
modes
:
l
Each line
l
RGBW
l
RGBW+CT
l
RGBW+CT
l
Each line
(RGBW)
l
RGBW+CT
Each line
(RGBW)
l
Each line
(dimmer+RGBW+fade)
and
modes
(RGBW)
21 channels :Strobe+Dimmer+Setting+
4 channels :
9 channels :Strobe+Dimmer+Setting+Macro color +
11 channels :Strobe+Dimmer+Setting+Macro color +
+ AUTO + AUTO/dimmer speed
16 channels:
27 channels:Strobe+Dimmer+Setting+Macro color +
+
30 channels:Strobe+Dimmer+Setting+Macro color +
CONTROL
MODE
14
Dimming
【
】 【
KEY-Lock
】 【
ON
】/【
OFF
】
{ENTER}
【
ON
】
enable lock
,【
OFF
】
disable lock
when you enable password lock and the fixture was in standby mode ,it need password { MODE
、
UP
、
MODE
、
DOWN
、
MODE
、
UP
、
MODE
、
DOWN }.then press the enter button to active.
PERSONALITY
[
[
[
Enable password lock

15
CALIBRATION
1
,
NO CALIBRATION
MANUAL
Color calibration mode is off.
2
,
Manual
calibration
mode
,
RGBW
to
white
is
according
your
custom
calibration.
Manual
calibration
can
calibrate
by
control
panel
and
DMX
channel
.
calibrate
by
control
panel
1
、
Press MODE button until
【
MANUAL
】
is displayed, press ENTER
3
、
Enter the password
3
、
Set
【
Red,Green,Blue
】
t
o
w
hite
by
c
ustom
c
alibration
Three
mode
of
color
calibration
calibrate
by DMX control
to
enter
dmx
c
ontroller
c
alibration
channel 4 is set to 245-249
Percent
0-100
0-100
0-100
0-100
0-89
90-95
96-97
98-10
0-99
100
0-100
0-100
0-100
0-100
DMX Value
0 - 255
0 - 255
0 - 255
0 - 229
230 - 234
240-244
245-249
250-255
0 - 254
255
0 - 255
0
-
255
0
-
255
0
-
255
channel
1
2
3
4
5
6
7
8
9
Function
No
function
No
function
No
function
No
function
3
come
back
t
o
D
MX
m
ode
No
function
3
turn
on
manual
calibration
mode
by dmx control
Illuminate display
3
Value must be held for 3 seconds to activate.
No
function
Save Correction,
Value must be held for 3 seconds to activate.
RED(0-255)
GREEN(0-255)
BLUE(0-255)
WHITE(0-255)
3,FACTORY
calibration
m
ode
Fixture is calibrated in the factor
y by radiant machine.

Specifications
Physical
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .495 mm
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233 mm
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .387 mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 kg without accessories
D
ynamic
Effects
Color mixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RGBW
Color temperature control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTO, variable 10 000 - 2500 K
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 PCS 4 in 1 LED
S h u t t e r e f f e c t s . . . . . . . . . . . . . . . . . . . E l e c t r o n i c , w i t h r e g u l a r a n d r a n d o m
pulse, burst and strobe effects
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21°
Control
and
Programming
Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DMX/Wireless DMX
DMX channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. .
Setting and addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control panel with backlit graphic display
Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . USITT DMX512-A
Construction
Color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Black
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High strength die-casting aluminum
Protection rating. . . . . .. . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . .IP 65
when DMX output and input is covered
Installation
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Any
Minimum distance to combustible materials . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mm. from fixture
Minimum distance to illuminated surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 mm. from fixture
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . must be fastened to structure or surface
Connections
AC power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PowerCon input socket (Ip65
when covered)
AC power throughput. . . . . . . . . . . . . . . . . . . . . . . . . . .PowerCon output socket (Ip65
when covered)
DMX data in/out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 pin locking XLR (Ip65 only when covered)
Electrical
AC
power
. . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . .
100
-
240
V
nominal
,
50
/
60
Hz
Maximum
total
power
consumption
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
360
W
Power
supply
unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auto
-
ranging
electronic
switch
mode
Power
consumption
,
all
effects
static
,
zero
light
output
. . . . . . . . . . . . . . . . . . . . . . . . <
10
W
Thermal
Cooling
. . . . . . . . . . .. . . .
Forced
air
(
temperature
-
regulated
,
low
noise
,
user
-
definable
FAN
levels
)
Maximum
ambient
temperature
(
Ta
max
.). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
°
C
Minimum
ambient
temperature
(
Ta
min
.). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
°
C
LED Quantity:
Beam Angle:
21/04/09/11/16/27/30 CHs
only
only
only
16