PDF User Manual

  1. Home
  2. Manuals
  3. BHO DZF-6050 Operation Manual

BHO DZF-6050 Operation Manual

DZF-6090\ DZF-6210

Made by: BHO
Type: Operation Manual
Category: Oven
Pages: 13
Size: 0.46 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

  

 

 

 

 

 

 

 

 

 

 

 

Vacuum Drying

 

Purging

 

Oven

(Controlled by Microchips with Timing Function)

Operation Manual

Our Lawyers Say:

 

This is a general-purpose vacuum oven for professional, industrial or educational use.

It is suitable for a working environment where no

 

flammable, volatile or combustible materials are being heated.

This oven is not intended for hazardous use.

Your satisfaction and safety require a complete understanding of this unit.

Read the instructions thoroughly and be sure all operators are given

 

adequate training before attempting to put the unit in

 

service.

This equipment must be used only for its intended application.

 

 

 

 

Our Design Engineers Say:

 

Your oven is intended for use indoors, at temperatures between 25°C and 40°C,<

 

80% Relative Humidity.

 

Extreme external

 

temperatures or humidity levels can affect the oven’s ability

 

to control temperature.

 

 

* If sample releases vapor under heating, place a dryer between the vacuum pump and the oven to

 

avoid vapor damage to the pump.

 

* Always wear thermal

 

gloves and protective goggles during operation.

 

* Always use the power cord that comes with the unit. Never modify the cable.

 

 

* Keep oven away from any electromagnetic interference. Do not unplug the oven during normal

 

operation.

 

*Do not try to heat flammable/explosive materials or materials that may release corrosive substances.

 

 

  

*When vacuuming is done, the vacuum valve should be closed first before turning off the power to

 

the vacuum pump; otherwise vacuum pump oil may backflow into the oven.

 

*Keep the oven clean at all time; clean the glass and chamber with soft cotton cloth after each use.

 

 

  

*If oven is to be kept idle for a long time, protect its circuit board with neutral grease or Vaseline to

 

avoid corrosion, and cover the oven entirely to keep it away

 

from dust and moisture.

 

 


background image

  

 

 

 

 

 

 

 

 

2. Features and specifications

These ovens can greatly reduce drying time by maintaining  a consistent vacuum level within the chamber. Oven operation is

controlled by a digital microcontroller  which is used to achieve

 

temperature  precision and accuracy. our vacuum ovens goes

 

through a 24-hour vacuum leak test before leaving our factory.

*Dual layer observation window with solid tempered safety glass.

*Radiant wall heating system(Surfacce Heating Tech) provides optimal

 

uniformity and conserves chamber space.

*Easy-to-clean 304 stainless steel interior for exceptional durability and ease of maintenance.

*Adjustable-force latch and door sealing gasket maintain consistent vacuum level.

 

 

 

 

 

 

 

 

 

Model:DZF-6050 Vacuum Oven/1.9CF

220V 50/60Hz 1-PH

 

5.9

 

Amps

USA standard 3-prong plug

1,

3

00 watts.Mica Heating Pads JP tech

Stainless steel SUS304#

 

 

 

 

Power

Power connection

 

Heaters

Chamber Material

 

Temperature controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low proportional gain, PID control for heater output

by microcomputer

Ambient to 100°C

Celsius

/Fahrenheit

±1

°C

/ ±1

°

F

1-9999 minutes

415 x 370 x 345mm (WxDxH)

Come with 4 removable aluminum heating shelves.

710 x 550x 550mm(WxDxH)

840 x 680 x 680mm(WxDxH)

Better than 500 microns/millitorrs depend on the Vacuum Pump.

 

<133Pa

 

 

 

 

 

 

 

KF-25 Vacuum Port

 

&

 

1/2

-10mm Hose Port (Gas

 

Back Fill System)

Silicone

Built-in circuit breaker, overheat protector

 

 

 

Temperature range

Temperature units

 

Temperature accuracy

 

Dwelling timer range

Chamber dim

Shelf

Unit dimensions

Shipping dimensions

Vacuum level

Maximum Vacuum

Vacuum Outlet/Gas Inlet

 

Door gasket material

 

Safety

Tempered Glass

Shipping weight

 

  

15mm tempered safety glass

 

8

1

kgs(Packed into Export Woodencase).

 

 


background image

  

 

 

 

 

 

 

 

Power

Power connection

 

Heaters

 

 

 

Chamber material

 

Temperature controller

 

 

 

 

 

 

 

 

Temperature range

Temperature units

 

Temperature accuracy

 

Dwelling timer range

 

Chamber dim

 

 

 

 

 

 

 

 

Shelf

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model:DZF-6090 Vacuum Oven/3.2

CF

220V 50/60Hz 1-PH

 

4.5Amps

USA standard 3-prong plug

1,000 watts.Built inside

 

2

 

aluminum shelves for the

fastest, most energy efficient and most even heating.

SUS304#

Low proportional gain, PID control for heater output

by

 

microcomputer

Ambient to

 

10

0°C

Celsius

/Fahrenheit

±1

°C

/ ±1

°

F

1-9999 minutes

18 x 18 x 18" (WxDxH) divided into three sections, arranged vertically.

2 non-removable

 

aluminum heated shelves,divided into two 17.5 x 17.5 x4" (WxDxH) sections,

arranged vertically.

30.9 x 23.4x 27.5"(WxDxH)

33.9 x 27.4 x32.5"(WxDxH)

Better than 500 microns/millitorrs depend on the

 

Vacuum Pump.

<133Pa

KF-25 Vacuum Port

 

&

 

1/2

-10mm Hose Port (Gas Back Fill System)

Silicone

Built-in circuit breaker, overheat protector

1

9

mm tempered safety glass

1

1

0KG

 

 

Unit dimensions

Shipping dimensions

Vacuum level

Maximum Vacuum

Vacuum Outlet/Gas Inlet

 

Door gasket material

 

Safety

Tempered Galss

Shipping weight

 

Custom Extra 2 removal aluminum shelves for 3.2

CF 

Vacuum Oven. 

 


background image

  

 

 

 

 

 

 

Power

Power connection

 

Heaters

 

 

 

Chamber material

 

Temperature controller

 

 

 

 

 

 

 

 

Temperature range

Temperature units

 

Temperature accuracy

 

Dwelling timer range

 

Chamber dim

 

 

 

 

 

 

 

 

Shelf

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model:DZF-6090 Vacuum Oven/3.4

CF

220V 50/60Hz 1-PH

 

6.8

Amps

USA standard 3-prong plug

1,

5

00 watts.Built inside

 

3

 

aluminum shelves for the

fastest, most energy efficient and most even heating.

S

US#304

Low proportional gain, PID control for heater output

by microcomputer

Ambient to

 

10

0°C

Celsius

/Fahrenheit

±1

°C

/ ±1

°

F

1-9999 minutes

18 x 18 x 18" (WxDxH) divided into three sections, arranged vertically.

3 non-removable aluminum heated shelves,divided into two 17.5 x 17.5 x5" (WxDxH) sections,

arranged

 

vertically.

30.9 x 23.4x 27.5"(WxDxH)

33.9 x 27.4 x32.5"(WxDxH)

Better than 500 microns/millitorrs depend on the Vacuum Pump.

<133Pa

KF-25 Vacuum Port

 

&

 

1/2

-10mm Hose Port (Gas Back Fill System)

Silicone

Built-in circuit breaker, overheat protector

19mm tempered safety glass

1

2

0KG

 

 

Unit dimensions

Shipping dimensions

Vacuum level

Maximum Vacuum

Vacuum Outlet/Gas Inlet

 

Door gasket material

 

Safety

Tempered Glass

Shipping weight

 

Custom Extra 3 removal aluminum shelves for 3.

4CF 

Vacuum Oven. 

 


background image

  

 

 

 

 

Power

Power connection

 

 

Heaters

 

 

 

Chamber material

 

Temperature controller

 

 

 

 

 

 

 

Model:DZF-6210 Vacuum Oven/7.8

Plus

220V 50/60Hz single phase

 

9.09

A

USA standard 3-prong plug

2000watts. Built inside

 

5

 

aluminum shelves for the

fastest, most energy efficient and most even heating.

SUS 304#

Low proportional gain, PID control for heater output

by microcomputer

Ambient to

 

10

0°C

Celsius

/Fahrenheit

 

 

 

 

 

 

Temperature range

Temperature units

 

Temperature accuracy

Dwelling timer range

Chamber dim

 

Shelf

 

 

 

 

 

 

 

 

 

±1

°C

/ ±1

°

F

1-9999 minutes

22 x 24 x 25" (WxDxH) divided into three 22 x 24 x

 

5

"

(WxDxH) sections, which arranged vertically.

5

 

non-removable aluminum heating shelves with individual in-oven temp sensor, heater and

controller (additional stackable shelves

 

available)

35 x 31 x 38" (WxDxH)

38 x 35 x 43" (WxDxH)

Better than 500 microns/millitorrs depend on Vacuum Pump.

 

 

 

 

 

 

 

 

 

 

 

<133Pa

13.5 CFM single stage

KF-25 Vacuum Port

 

&

 

1/2

-10mm Hose Port (Gas Back Fill System)

Silicone

19mm

 

  

Unit dimensions

 

Shipping dimensions

Vacuum level

Maximum

vacuum pressure

Vacuum Pump

Vacuum Outlet/Gas Inlet

Door gasket material

  

Tempered Glass

 

Unit/shipping weight

 

220Kgs

 

Custom Extra 

removal aluminum shelves for 

7.8Plus  

Vacuum Oven. 

 


background image

  

 

 

 

3. Guidelines

 

using the vacuum oven

1. Put your

 

target

 

into the

 

vacuum

 

oven;

 

C

lose the door;

 

C

lose the

 

black

 

vacuum release; open the vacuum valve

and turn on the power to the vacuum pump to start the purging process

,

When vacuum level in the oven reaches

 

30 inch mercury

 

(or read

 

76cmHg);

 

C

lose the vacuum valve first

 

BEFORE

 

turn off the vacuum pump.

 

 

2. Turn on the

 

Vacuum

 

oven,

 

S

et target temperature and confirm it. Temperature in the oven starts to rise and

 

the heating indicator will blink.

 

 

 

 

3. If your target temperature is low, setting can be done twice to minimize temperature spike. For example, if

target temperature is 40°C, the first target temperature value can be set to 30°C, and when temperature rises

 

excessively and starts to drop, set the temperature one more time to 40°C.Thus,temperature overshooting can be

 

reduced or prevented and temperature dwelling state can be started ASAP.

 

 

 

4. Length of  drying time should be selected  based on humidity level  of your sample. In  case drying time is long

and vacuum  level reduces, it  is

 

necessary to  purge the oven  again to restore  desired vacuum level  (make sure

 

your vacuum pump can work at your target temperature).

 

 

 

5.

A

fter

 

purging

 

drying process done, turn off the oven; open the vacuum release valve before opening the door.

It is possible that the sealing gasket may stuck onto the glass door and the door cannot be open easily. Wait a

 

while until the gasket restores itself before trying to open the door again.

 

 


background image

  

 

4.

 

Preset target temperature “SP” & Purging working time St

Running

 

mode: after the oven is first turned on, controller will be in running mode.

 

Setting mode: hold and “Set” button for

 

6 seconds in running mode to enter into the setting mode.

 

Controller will return to running mode automatically if no action is taken in 60

 

seconds.

 

4-1. Setting target temperature and dwelling time

 

1. Plug in power cable, switch on circuit breaker in the back and turn on the oven.

 

 

 

2

. Press ‘Set’ button once, controller will display “SP”, now use “Shift”, “Decrease” or “Increase”

 

button to set

 

your target

 

temperature.

 

 

3

. Press ‘Set’ again to confirm, controller will display “S

t

”, now use “Shift”, “Decrease” or “Increase” button to set dwelling time

 

in minutes (you can set it to display in hours with the “Hn”

 

 

setting). Oven starts timing the

 

first time actual temperature re

aches target temperature. If “S

t

” is

 

set to zero, oven will

 

continue to run at target temperature until turned off manually.

 

4

. Press ‘Set’ again to confirm all settings.

 

5. When dwelling time is up, the controller will

 

disp

lay “End” and buzz for 60 seconds. It can be

 

muted by pressing any button.

 

6

. Press and hold “Reset” for 3 seconds to restart oven operation.

 

 

7. During heating, if alarm is set and actual temperature is over that limit, buzzer will sound continuously a

nd “ALM” light will

 

come on. Press any key to mute it.

 

Prompts

 

Names

 

 

 

Description

 

 

Sp

 

St

 

 

Target Temperature value

 

Dwelling time

 

 

 

range Default

value

Amb+10

℃~

100

0-9999 (0) minutes

 

Single point control set temperature(

)

0 = continuous heating, use co

de “Hn” to

 

change unit

 

 


background image

  

 

 

 

 

 

 

 

 

*

MENU I & MENU II

Under running mode, press and hold “Set” button for

 

6

 

seconds;

 

C

ontroller will display “Lc”.

Enter

 

3

 

and press

 

“Set” for the menu in

 

MENU I

E

nter

 

9

 

and press “Set” for menu in

 

MENU II

.

After you done with the setting

 

change, press and hold “Set” for 3 seconds to

 

save and exit to running mode

.

MENU I:

Prompt

 

Name

 

Description

 

 

 

 

 

 

When Lc = 3, controller enters into the menu below

 

 

If SV>(SP+AL), ALM light comes up, buzzer sounds and oven stops

 

heating

Represents the specific control method of the relay.

 

 

 

 

 

Pass Key

Over-temp alarm

Control Cycle

 

Lc

 

AL

T

 

P

 

Proportional

 

Increase P reduce temperature overshooting,decrease P to allow faster heating rate.

 

default Value

3

0~100(5)

5

35

 

I

 

Integral

 

Increase I to lower temperature

 

fluctuation

 

Adjusted to reduce temperature overshooting.

 

 

1~1000s

(200s)

 

D

 

Differential

 

 

0~1000s

(200s)

 

Pb

 

 

 

 

 

 

 

-10~10

(0)

 

Ambient

 

adjustment

 

PK

 

Et

 

Hot adjustment

 

Timing Function

 

 

 

 

 

 

-999~999

(0)

0~2(2)

 

 

 

Offset the temperature difference ambient and oven when it is turn off.

Pb   =   temperature    measured   by   exterior thermocouple(s)

 

 

temperature displayed by

controller

Offset the temperature difference between the controller and actual reading inside

the oven. (use the calibration formula in 5-2 section)

0: no timer function

1: with timer function, SV window will always display dwelling time.

2: with timer function, SV window will display dwelling time after oven temperature

reaches target temperature.

 

 


background image

  

MENU II:

 

Prompt 

Name 

Description 

default Value 

Lc 

Pass key 

Shut off 

When Lc = 9, controller enters into the menu below 

Co 

If SV>(SP+Co), ALM light comes up, buzzer sounds and oven stops heating 

0~50(5) 

Heat Function 

Timer unit 

Hn 

En 

0: minute 1: hour 

0-1 (0) 

0~1(0) 

Timer end mode 

0: stop temperature controller when dwelling time is over 

1: continue to display temperature when dwelling time is over 

Lt 

Max Watt Output     Max Watt heating Output 

0~100 

(

100

0~1 

oP 

Door Controll 

Function 

0,Door Controller Function(Close) 

1,Door Controller Function (Open) 

*The Function is under innovation. 

(1) 

rH 

Max temperature     Set maximum temperature the controller can go to 

(Do NOT modify. Setting max temperature too high could permanently damage your oven) 

0~400 

(100) 

 


background image

  

10 

 

 

 

 

 

AutoTune

1:)

Plug on

 

220Volts 50/60Hz Open

 

the  power switch

.

2:)Press "set" then increase or decrease to target temp (eg

.

 

Sp=

33

).

  

then press "set" (St=0) and then press "set"

 

6 seconds

 

save and exit.

It is easily to operate in default leaving factory for

 

purging drying process

.

 

 

 

 

 

 

 

 

If client are not

 

satisfied with target temp (always find over heat problem)during heat process.

How to make it normal working? Easily Follow below steps:

1:)Power Off Vac Oven and Open Door Cool down inside oven temp below 33deg C----(Cool Down 30-50minutes).

2:)

Power On

.Then Press  "set" 6" it  will showing Lc"  increase 3 then  entry into "Menu  I" Press "Set"  again to find  out "P"

increase "35" press "set" again I" increase "200" press "set" then D" increase "200" then press "set" 6" save and exit.

3:)Press "AT" 6" it will entry into Autotune Process for (eg

 

33

deg C ) The "AT" light flashing and working to find out the best

 

PID data and save and exit

 

(once it finished the light always light on).Then Power Off. Wait 30 minutes.

 

 

Autotune Process

 

function:in order to  avoid Over Heating Temp(eg. You want 48deg  C if AT,it will not over heat  higher than

 

<50deg C) to protect material.

 

Caution:Autotune Process 50deg C ( 30-50deg C ) the uniform temp working well and without over heat temp.

 

 


background image

  

11 

5. How to Calibrate your vacuum oven.  

NOTE: Before calibrating your oven, make sure you are familiar with basic oven heating operation. 

Every oven has been calibrated and tested before leaving our factory, usually self calibration is not necessary. 

However, if the temperature requirements are very strict, or if target temperature is set around upper or lower 

limits of the oven temperature range, the measured temperature might not be accurate against the actual 

temperature in the oven. 

5-1. Calibration by Auto-Tune (AT) 

Use auto-tune to set a more accurate temperature control and faster heating rate. 

a. Set temperature to your maximum target temperature, press “Set” to confirm.

 

b. Under running m

ode, press and hold “Shift/AT” button for 5 seconds until the indicating light “Run/AT”

 

starts to blink. The oven is now in PID auto-tune mode. 

c. After two cycles of fluctuation, auto-tune is done and the AT light goes off. This could take a few hours. The 

“Set” button is disabled during this period.

 

d. New PID parameters are automatically saved for future use. 

e. Now set the target temperature. You will be ready to use the oven. 

5-2. Calibration by formula 

First, calculate the offset value using the formu

lation below. Then press and hold “Set” button for 3 

seconds; 

controller will display “Lc”. Enter 3 and press “Set”. Go to “PK” and set it to your calculated offset value.

 

Press and hold “SET” for 3 seconds to confirm.

 

Offset value = (temperature measured by exterior thermocouple(s) 

 temperature displayed by 

controller) x 1000 / temperature displayed by controller 

5-3. Calibration by adjusting PID manually (requires experience and practice) 

After an auto-turn, if you still feel that temperature is unstable, you can manually adjust PID. PID adjustment 

is a very useful for you to control the oven temperature in an acceptable range but requires some practice and 

patience. 

After an auto-tune, if you still feel that temperature is unstable, you can manually adjust PID. PID adjustment 

is a very useful tool for controlling the oven temperature within an acceptable range, but requires some 

practice and patience. 

a. First, adjust P whenever you start a PID adjustment. P represents proportion adjustment; increasing P 

reduces temperature overshooting, while decreasing P to allow for a faster heating rate. (You may need to try 

this step a few times before you get the best result). 

b. “I” represents integral time. Increase I to lower temperature fluctuation. It can be use

d to eliminate the 

steady-state error after the system enters a steady state by correctly setting P. In other words, I is often used 

after P. Give I a big value before decreasing P a little, in order to get to a steady state, and then decrease I to 

eliminate errors under the steady state. Check if the PV is in your desired range. Continue to try to change 

P and I to get the best result. 

c. “D” represents differential time, which can overcome the unstable and oscillating state. Adjust D to reduce

 

temperature overshooting. It is usually set after I adjustment. Firstly, set D to 0, then gradually increase it to 

check if you have an acceptable result (In this process, P and I may also be changed). 

 


background image

  

12 

6. Troubleshooting. 

Without Power 

Without power supply 

Broken power cord or Loose plug 

Circuit breaker is off 

Check power supply 

Change power cord 

Turn on circuit breaker 

PV window is 

displaying 

Faulty pt100 thermocouple or loose 

connection 

Check   connection   or    change 

thermocouple 

-----

”, “LLL.L” or “HHH.H”

 

Faulty temperature controller 

If the thermocouple is OK and connection 

is good, replace  the  temperature 

controller. 

Failure to heat unit 

Setting times out 

Modify the set time and restart the oven 

Check and make sure all connection 

Loose connection on temp controller 

Faulty controller 

Faulty heating element 

Replace temperature controller 

Replace heating elements 

Reset all parameters to default 

Check all connections 

Parameter error 

Temperature control Fail 

Loose connection on pt-100 thermocouple 

Faulty controller 

Replace temperature controller 

Adjust preset temperature 

Preset temperature too low 

Abnormal alarming 

Faulty controller 

Without Vacuum 

Parameter error 

Replace temperature controller 

Vacuum the oven 

for oven temperature 

Large  temperature 

Reset all parameters to default 

difference  between 

Sensor of thermometer has been placed at 

incorrect place 

Place the sensor on the oven self 

PV value and actual 

value 

 


background image

  
  

 

13 

8. Support 

We offer 2 year limited replacement warranty for all electronic parts from the date we shipped goods. 

If you find any defective parts caused by manufacturer please feel free to contact us and 

we will replace them for you. 

 

 

420PMU

is not responsible for any damage or consequence damage caused by misuse.

 

After the 

warranty period, we will continue to provide support

 

and spare parts at a reasonable cost.