ADCOM GFA-6006/02 Owner’s Manual |

GFA-6002

& GFA-6006

Custom Install Power Amplifiers

G       F       A

6006

distortion alert          >

<    on / standby

ch 1

ch 2

ch 3

ch 4

ch 5

ch 6

thermal protection     >

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

2

3

ADCOM GFA-6006/02 Owner’s Manual |

WELCOME

Dear Fellow ADCOM Product Owner,

Welcome  to  the ADCOM  family!  For  more  than  twenty  years, ADCOM  products  have  delivered 

excellent performance and value for customers around the world. Our products are designed by 

our experienced and demanding engineering team, built to the highest standards in our factory, 

and sold and serviced through dealers, custom installers, and other retailers whose primary goal 

is your complete satisfaction.

We  know  you  are  anxious  to  hear  your  new  power  amplifier  in  action,  but  please  take  a  few 

minutes to read this owner’s manual before connecting the power amplifier to your system. It 

is particularly important that you connect your power amplifier to your preamplifier while they 

are unplugged and your other equipment is turned off. This will protect your equipment from 

potential short circuits that may occur during installation. In addition, it is important that you 

allow for adequate ventilation around your power amplifier and other equipment, since excessive 

heat buildup can shorten the life of any electronic product, including the power amplifier. Once 

you have correctly connected your new power amplifier to your other components, you should 

be able to enjoy many trouble-free years of performance.

We conduct a thorough quality and performance test on each and every power amplifier we build 

in our factory prior to shipment. In the rare case of a defect that may occur after shipment, we 

stand behind our power amplifier with a five-year parts and labor warranty. To register for this 

warranty,  please  complete  and  mail  the  enclosed  warranty  card  back  to ADCOM.  Also,  please 

keep a copy of your sales receipt with the owner’s manual so you may provide proof of eligibility 

for the warranty should the need arise.

We know you will be very happy with the audio performance of your new power amplifier. We 

hope you will also consider other ADCOM products, such as our line of multichannel amplifiers, 

preamplifiers  and  digital  source  components.  In  addition,  we  design  and  manufacture  comple-

mentary  products  such  as  surge  suppressors  and  speaker  selectors.  Please  visit  our  web  site  at 

www.adcom.com to learn more about our complete line of stereo, home theater, and distributed 

audio/video products.

On behalf of all of us at ADCOM, I want to thank you for selecting our product for your home or 

business entertainment system. 

Sincerely,

Douglas Klein

President

ADCOM is a registered trademark of Klein Technology Group, LLC.

ADCOM 

Telephone: (480) 607-2277

A division of Klein Technology Group, LLC 

Fax: (480) 348-9876

8541 East Anderson Drive 

Email: info@adcom.com

Scottsdale, Arizona 85255 USA 

Web: www.adcom.com

Copyright © 2003 Klein Technology Group, LLC. All rights reserved. No part of this manual may be repro-

duced or electronically transmitted without the express written consent of Klein Technology Group, LLC.

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

2

3

ADCOM GFA-6006/02 Owner’s Manual |

Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2

Table of Contents . . . . . . . . . . . . . . . . . . . . . .  3

Precautions and Warnings . . . . . . . . . . . . . . .  4

Unpacking Your Amplifier . . . . . . . . . . . . . . .  5

Safety Information . . . . . . . . . . . . . . . . . . . . .  5

Description & Features . . . . . . . . . . . . . . . . .  6

Installing & Connecting . . . . . . . . . . . . . . . . .  7

Description of Front Panel . . . . . . . . . . . . . .   8

Front Panel Illustration . . . . . . . . . . . . . . . . .   8

Description of Rear Panel. . . . . . . . . . . . .  9-11

Rear Panel Illustration . . . . . . . . . . . . . . . . . .  9

Trouble Shooting . . . . . . . . . . . . . . . . . . . . .  12

Service Information . . . . . . . . . . . . . . . .  12-13

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . .   13

Your Responsibilites . . . . . . . . . . . . . . . . . . .  13

GFA-6002 Specifications . . . . . . . . . . . . . . .  14

GFA-6006 Specifications . . . . . . . . . . . . . . .  15

TABLE OF CONTENTS

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

4

5

ADCOM GFA-6006/02 Owner’s Manual |

THE FOLLOWING PRECAUTIONS AND SAFETY INSTRUCTIONS 

ARE REQUIREMENTS OF UL AND CSA SAFETY REGULATIONS

Warning: To reduce the risk of fire or electric shock, do 

not expose this unit to rain or moisture.

The  graphic  symbol  of  a  lightning  flash  with  an 

arrow  point  within  a  triangle  signifies  that  there 

is  dangerous  voltage  within  the  unit  and  it  poses 

a  hazard  to  anyone  removing  the  cover  to  gain 

access  to  the  interior  of  the  unit.  OnIy  qualified 

service  personnel  should  make  any  such  attempt.

The  graphic  symbol  of  an  exclamation  point  within 

an  equilateral  triangle  warns  a  user  of  the  device 

that it is necessary to refer to the instruction manual 

and  its  warnings  for  proper  operation  of  the  unit.

Do not place this unit on an unstable cart, stand, tripod, 

bracket, or table. The unit may fall, causing serious 

injury to a child or adult, and serious damage to the 

unit.  Use only with a cart, stand, tripod, bracket, or 

table recommended by the manufacturer or sold with 

the unit. Any mounting of the device should follow the 

manufacturer’s instructions, and should use a mounting 

accessory  recommended  by  the  manufacturer.

Read  all  the  safety  and  operating  instructions  before  connecting  or  using 

this unit.

Retain this notice and the owner’s manual for future reference.

All warnings on the unit and in its operating instructions should be adhered to.

All operating and use instructions should be followed.

Do not use this unit near water. For example, near a bathtub, washbowl, 

kitchen sink, laundry tub, in a wet basement, or near a swimming pool.

The unit should be installed so that its location or position does not interfere 

with  its  proper  ventilation.  For  example,  it  should  not  be  situated  on  a 

bed, sofa, rug, or similar surface that may block the ventilation openings; 

or placed in a built-in installation, such as bookcase or cabinet, that may 

impede the flow of air through its ventilation openings.

The unit should be situated away from heat sources such as radiators, heat 

registers, stoves, or other devices (including amplifiers) that produce heat.

The unit should be connected to a power supply outlet only of the voltage 

and frequency marked on its rear panel.

The power supply cord should be routed so that it is not likely to be walked 

on or pinched, especially near the plug, convenience receptacles, or where 

the cord exits from the unit.

Clean unit only as recommended in its instruction manual.

The power supply cord of the unit should be unplugged from the wall outlet 

when it is to be unused for a long period of time.

Care should be taken so that objects do not fall, and liquids are not spilled, 

into the enclosure through any openings.

This unit should be serviced by qualified service personnel when:

A. The power cord or the plug has been damaged; or

B. Objects have fallen, or liquid has been spilled, into the unit; or

C. The unit has been exposed to rain, or liquids of any kind; or

D. The unit does not appear to operate normally, or exhibits a marked  

  change in performance; or

E. The device has been dropped, or the enclosure damaged.

DO  NOT  ATTEMPT  SERVICING  OF  THIS  UNIT  YOURSELF. 

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

ATTENTION

POUR PREVENIR LES CHOCS ELECTRIQUES NE PAS UTILISER CETTE FICHE 

POLARISEE AVEC UN PROLONGATEUR, UNE PRISE CE COURANT OU UNE 

AUTRE SORTIE CE COURANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES 

A FOND SANS EN LAISSER AUCUNE PARTIE A DECOUVERT.

CAUTION

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS POLARIZED PLUG WITH 

AN  EXTENSION  CORD,  RECEPTACLE  OR  OTHER  OUTLET  UNLESS  THE 

BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.

CAUTION POWER LINES

Any outdoor antenna must be located away from all power lines.

OUTDOOR ANTENNA GROUNDING

If  an  outside  antenna  is  connected  to  your  tuner  or  tuner/preamplifier, 

be sure the antenna system is grounded so as to provide some protection 

against  voltage  surges  and  built-up  static  charges.  Section  810  of  the 

National  Electrical  Code,  ANSI/NFPA  No.  701984,  provides  information 

with respect to proper grounding of the mast and supporting structure, 

grounding  of  the  lead-in  wire  to  an  antenna  discharge  unit,  size  of 

grounding conductors, location of antenna discharge unit, connection to

grounding electrodes, and requirements for the grounding electrode.

a. Use No.10 AWG (5.3 mm

2

) copper, No.8 AWG (8.4 mm

2

) aluminum, No.17 

AWG (1.0 mm

2

) copper clad steel or bronze wire, or larger, as a ground wire.

b.  Secure  antenna  lead-in  and  ground  wires  to  house  with  stand-off 

insulators spaced from 46 feet (1.221.83 m) apart.

c.  Mount  antenna  discharge  unit  as  close  as  possible  to  where  lead-in  enters 

house.

d. Use jumper wire not smaller than No.6 AWG (13.3 mm

2

) copper, or the 

equivalent, when a separate antenna grounding electrode is used. See NEC 

Section 810-21 (j).

EXAMPLE  OF  ANTENNA  GROUNDING  AS  PER  NATIONAL  ELECTRICAL  CODE 

INSTRUCTIONS CONTAINED IN ARTICLE 810. RADIO AND TELEVISION EQUIPMENT.

NOTE TO CATV SYSTEM INSTALLER

This reminder is provided to call the CATV system installer’s attention to 

Article 82022 of the National Electrical Code that provides guidelines for 

proper grounding and, in particular, specifies that the cable ground shall 

be  connected  to  the  grounding  system  of  the  building,  as  close  to  the 

point of cable entry as practical.

power lines

ground clamp

power service grounding

electrode system

(e.g. interior metal water pipe)

ground clamps

ground clamps

optional antenna grounding

electrode driven 8 feet (2.44 M) into

the earth if required by local codes.

bonding jumper, d

service

entrance

equipment

service entrance

conductors

standoff

insulators, b

mast

antenna

lead-in wire

antenna

discharge

unit, c

ground wire, a,b

to external antenna

terminals of radio receiver

ground wire, a,b

CAUTION

RISK OF ELECTRIC SHOCK 

DO NOT OPEN

CAUTION

RISK OF ELECTRIC SHOCK 

DO NOT OPEN

CAUTION

RISK OF ELECTRIC SHOCK 

DO NOT OPEN

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

4

5

ADCOM GFA-6006/02 Owner’s Manual |

Unpacking the Amplifier

Before your new ADCOM amplifier left 

our factory, it was carefully inspected 

for  physical  imperfections  and  tested 

for  all  electrical  parameters  as  a 

routine  part  of  ADCOM’s  systematic 

quality  control.  This,  along  with  full 

operational  and  mechanical  testing, 

should  ensure  a  product  flawless  in 

both  appearance  and  performance. 

After  you  have  unpacked  the  GFA-

6002/06,  inspect  it  for  physical 

damage.  Save  the  shipping  carton 

and  all  packing  material  as  they  are 

intended  to  reduce  the  possibility  of 

transportation  damage  should  the 

amplifier  ever  need  to  be  shipped 

again.  In  the  unlikely  event  damage 

has  occurred,  notify  your  dealer 

immediately and request the name of 

the carrier so a written claim to cover 

shipping damages can be initiated. The 

right to a claim against a public carrier 

can  be  forfeited  if  the  carrier  is  not 

notified promptly in writing and if the 

shipping carton and packing materials 

are not available for inspection by the 

carrier. Save all packing materials until 

the claim has been settled.

Safety Instructions

 

DANGER:

  Visible  and  invisible  laser 

radiation  when  open  and  interlock 

failed  or  defeated.  Avoid  direct 

exposure to beam.

WARNING:

  There  are  no  user 

serviceable 

parts 

inside. 

Refer 

all  servicing  to  qualified  service 

personnel.

WARNING:

  To  reduce  the  risk  of  fire 

or  electric  shock,  do  not  expose  the 

unit  to  moisture  or  water.  Do  not 

allow  foreign  objects  to  get  into  the 

enclosure.  If  the  unit  is  exposed  to 

moisture, or a foreign object gets into 

the enclosure, immediately disconnect 

the power cord from the wall. Take the 

unit  to  a  qualified  service  person  for 

inspection and necessary repairs. Read 

all  the  instructions  before  connecting 

or  operating  the  component.  Keep 

this manual so you can refer to these 

safety  instructions.  Heed  all  warnings 

and  safety  information  in  these 

instructions and on the product itself. 

Follow all operating instructions. Clean 

the enclosure only with a dry cloth or a 

vacuum cleaner. You must allow 10 cm 

or 4 inches of unobstructed clearance 

around the unit. Do not place the unit 

on a bed, sofa, rug, or similar surface 

that  could  block  the  ventilation 

openings.  If  the  unit  is  placed  in  a 

bookcase  or  cabinet,  there  must  be 

ventilation  of  the  cabinet  to  allow 

proper  cooling.  Keep  the  component 

away  from  radiators,  heat  registers, 

stoves,  or  any  other  appliance  that 

produces heat.
The unit must be connected to a power 

supply  only  of  the  type  and  voltage 

specified  on  the  rear  panel.  Connect 

the  component  to  the  power  outlet 

only  with  the  supplied  power  supply 

cable  or  an  exact  equivalent.  Do  not 

modify  the  supplied  cable.  Do  not 

defeat  grounding  and/or  polarization 

provisions.  The  cable  should  be 

connected  to  a  3-pin  polarized  wall 

outlet, matching the wide blade of the 

plug to the wide slot of the receptacle. 

Do  not  use  extension  cords.  Do  not 

route  the  power  cord  where  it  will 

be  crushed,  pinched,  bent,  exposed 

to  heat,  or  damaged  in  any  way.  Pay 

particular attention to the power cord 

at the plug and where it exits the back 

of the unit. The power cord should be 

unplugged from the wall outlet if the 

unit  is  to  be  left  unused  for  a  long 

period of time. Immediately stop using 

the  component  and  have  it  inspected 

and/or serviced by a qualified service 

agency if:
•  the power supply cord or plug has 

  been damaged;

•  objects have fallen or liquid has 

  been spilled into the unit;

•  the unit has been exposed to rain;

•  the unit shows signs of improper  

  operation; or

•  the unit has been dropped or 

  damaged in any way.

FCC Information:

 This equipment 

has been tested and found to comply 

with the limits for a Class B digital 

device, pursuant to Part 15 of the 

FCC Rules. These limits are designed 

to provide reasonable protection 

against harmful interference in 

a residential installation. This 

equipment generates, uses and 

can radiate radio frequency energy 

and, if not installed and used in 

accordance with the instruction, may 

cause harmful interference to radio 

communications. However, there is 

no guarantee that interference will 

not occur in a particular installation. 

If this equipment does cause harmful 

interference to radio or television 

reception, which can be determined 

by turning the equipment off and 

on, the user is encouraged to try to 

correct the interference by one or 

more of the following measures:
•  Reorient or relocate the receiving  

  antenna.(TV, radio, etc.)

•  Increase the separation between  

  the equipment and receiver

•  Connect the equipment to an outlet  

  on circuit different from that to  

  which the receiver is connected.

•  Consult the dealer or an  

 

  experienced radio/TV technician 

  for additional help.

Caution:

  This  device  complies  with 

part  15  of  the  FCC  Rules  operation  is 

subject to the following to conditions: 

(1) This device may not cause harmful 

interference, and (2) this device must 

accept  any  interference  received, 

including interference that may cause 

undesired operation.

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

6

7

ADCOM GFA-6006/02 Owner’s Manual |

Description of Unit

Congratulations on your decision to purchase the GFA-6002 or 
GFA-6006 custom installation power amplifier. The GFA-6002 
and GFA-6006 have been designed to be musically accurate 
in a configuration specifically designed to integrate with any 
home audio pre-amplifier. You have made a wise choice that 
will reward you for years to come with exceptionally accurate 
and musical sound reproduction. To realize the full potential 
of your new amplifier, and before making any connections to 
it, please read these operating and installation instructions 
thoroughly.

GFA-6002 Features

• Precision-matched devices used throughout the signal path

• 27,000 µF of power supply-filter capacitance to optimize 
transient response

• Bridgeable operation

• Audio IN and OUT for each channel for flexible system 
configuration

• Independent input level controls for each channel

• Independent power supplies for each channel

• Fewer gain stages improve signal reproduction accuracy

• Custom toroidal power transformer provides better 
regulation and greater peak current capability

• Independent thermal-overload and distortion LEDs for all  
channels

• High quality, gold-plated 5-way binding posts

• High quality, gold-plated RCA jacks

• Large independent internal heatsinks for greater cooling 
capability of output devices

• Two convenient modes of power ON/OFF triggering; 3-30V 
AC/DC triggering & audio signal sensing

• Heavy gauge, anodized aluminum front panel

• Powder-coated, baked chassis and top cover for greater 
durability

• Cooling vents for greater efficiency and cooler operation 
while driving low impedance loads

• Ground lift to eliminate ground loops

• Detachable AC cord for easier installation 

GFA-6006 Features

• Precision-matched devices used throughout the signal path

• 60,000 µF of power supply-filter capacitance to optimize 
transient response

• Bridgeable operation; 6/5/4/3 channels

• Audio IN and OUT for each channel for flexible system 
configuration

• Independent input level controls for each channel

• Independent power supplies for each channel

• Fewer gain stages improve signal reproduction accuracy

• Custom toroidal power transformer provides better 
regulation and greater peak current capability

• Independent thermal-overload and distortion LEDs for all 
channels

• High quality, gold-plated 5-way binding posts

• High quality, gold-plated RCA jacks

• Large independent internal heatsinks for greater cooling 
capability of output devices

• Two convenient modes of power ON/OFF triggering;3-30V 
AC/DC triggering & audio signal sensing

• Heavy gauge, anodized aluminum front panel

• Powder-coated, baked chassis and top cover for greater 
durability

• Cooling vents for greater efficiency and cooler operation 
while driving low impedance loads

• Ground lift to eliminate ground loops

• Detachable AC cord for easier installation

G       F       A

6006

distortion alert          >

<    on / standby

ch 1

ch 2

ch 3

ch 4

ch 5

ch 6

thermal protection     >

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

6

7

ADCOM GFA-6006/02 Owner’s Manual |

Installing the GFA-6002

and GFA-6006

During  normal  home  operation  the 
internal  heatsinks  of  the  GFA-6002/
6006  may  become  warm.  However, 
there  are  instances  during  high-level 
playback  into  low  impedances  when 
the  heatsinks  will  become  much 
warmer  than  usual.  To  ensure  the 
amplifier’s  long-term,  trouble-free 
operation  it  is  necessary  to  provide 
adequate ventilation for the heatsinks. 
Therefore,  the  GFA-6002/6006  should 
be  kept  away  from  external  sources 
of  heat  such  as  radiators  and  hot-air 
ducts. The GFA-6002/6006 should never 
be  placed  with  other  heat-producing 
components  in  a  cabinet  or  enclosure 
lacking  free  air  flow.  The  top  and 
bottom panel of the amplifier’s chassis 
have been provided with vents to allow 
the  necessary  cooling  of  the  internal 
components. It is imperative that these 
vents are not obstructed in any way.

We  recommend  that  you  do  not  stack 
other  components  on  top  of  the 
GFA-6002/6006.  This  is  particularly 
important  if  your  system  includes 
low-impedance  loudspeakers  which 
are  difficult  to  drive,  or  if  you  will 
consistently  demand  high  volume 
levels  from  the  amplifier  and  speaker 
system. Not only will heat generated by 
the  amplifier  affect  the  performance 
of  equipment  stacked  on  top  of  the 
GFA-6002/6006,  but  the  free  flow  of 
air through the ventilating slots in the 
amplifier may be partially obstructed.

If you observe these recommendations, 
the  GFA-6002/6006  will  perform 
reliably in any reasonable environment. 
You  should  also  pay  attention  to  such 
normal  considerations  as  protection 
from  excessive  dust  and  moisture. 
Occasional  vacuuming  of  accumulated 
dust on the chassis, panels and around 
the ventilating slots should be all that 
is required.

The optimal performance of your new 

GFA-6002/6006  will  ultimately  depend 
on the care with which you make the 
connections  between  the  amplifier, 
pre-amplifier,  surround  sound  decoder 
and  the  loudspeakers.  All  input  and 
output  signal  connections  should  be 
made only with high quality, low-loss, 
low  capacitance  cables  following  the 
recommendations  in  the  Inputs  and 
Outputs  section  of  CONNECTING  THE 
GFA-6002/6006.

Connecting the

GFA-6002 and GFA-6006

When  connecting  the  amplifier  to  the 
loudspeaker,  it  is  vital  to  maintain 
proper  polarity  (positive  to  positive, 
negative  to  negative).  On  the  GFA-
6002/6006,  the  positive  terminal  is 
color coded RED and labeled “+,” and 
the negative is color coded BLACK and 
labeled “-”.  The positive terminal on 
the speaker will be color coded RED, or 
will be labeled “+,” “pos,” “positive,” 
“8  ohms”  or  “4  ohms.”  The  negative 
terminal  on  the  speaker  will  be  color 
coded  BLACK,  or  will  be  labeled  “-,” 
“neg,”  “negative,”  “C,”  “Common,” 
“G,” or “ground.”

We  recommend  that  your  speaker 
cables  be  terminated  with  “U”  type 
spade  connectors.  These  will  give  the 
most  contact  area  insuring  long-term 
reliability.  The  spade  connector  should 
have a maximum width of 0.57 inches and 
an opening width of no less than 0.25".

To properly connect the speaker cable 
to the binding posts, turn the insulated 
head of the binding post clockwise until 
the wire or connector is firmly secured. 
Finger  pressure  is  sufficient  and  you 
should  not  use  pliers  or  other  tools 
which  could  damage  or  over-tighten 
the binding-post assembly. The binding 
posts  have  been  designed  in  such  a 
way  that  finger  pressure  is  all  that  is 
required  to  cause  a  “pinching”  action 
among the different metal surfaces to 
ensure proper connection.

It  is  very  important  to  use  the 
correct  size  of  wire  in  order  to  avoid 
unnecessary  loss  of  amplifier  power 
in  the  cable,  reduction  of  amplifier 
damping  factor  and  other  undesirable 
conditions.  Sound  audio  engineering 
practice  suggests  the  use  of  at  least 
AWG16,  stranded,  copper  cable. 
Recommended  capacitance  of  the 
speaker  wire  should  not  exceed  5OpF 
per foot. This insures high frequencies 
will not be rolled off.

All  loudspeakers  having  a  nominal 
impedance  down  to  4  ohms  can  be 
connected  to  and  driven  by  the  GFA-
6002/6006.  The  amplifier  can  drive 
these  low-impedance  speakers  at 
more  than  adequate  power  levels 
with  no  difficulty.  It  should  be  noted 
that  many  loudspeaker  systems  which 
are  nominally  rated  at  4  ohms  drop 
in  impedance,  in  some  parts  of  their 
frequency range, to as low as 2 ohms 
(and  sometimes  less).  You  will  not 
experience difficulties even with these 
very  low  impedance  loads  unless  you 
demand excessively high volume levels 
from your system.

We  do  not  recommend  that  you  run 
multiple  sets  of  speakers  to  each 
speaker output on the GFA-6002/6006. 
Instead, we recommend that you use a 
multiple  speaker  selector  such  as  the 
ADCOM GFS-300 or GFS-600. A speaker 
selector enables you to maintain good 
sonic  integrity  while  giving  you  the 
flexibility  to  add  speakers  throughout 
your  house  and  maintain  proper 
impedance levels to help prevent over 
heating of the amplifier.

Finally,  we  suggest  that  you  follow 
this chart for speaker wire lengths and 
gauges. If longer runs are needed, it is 
best to consult with your ADCOM Dealer 
to  maximize  the  performance  of  your 
system with your exact conditions.

up to 24 feet — AWGI6 
up to 36 feet — AWGI4 
up to 58 feet — AWGI2

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

8

9

ADCOM GFA-6006/02 Owner’s Manual |

Description of Unit:

Front Panel

[1] On/Standby/Vacation

This LED monitors the status of operation 
of  the  amplifier.  The  LED  will  glow 
amber whenever the rear panel Power/
Vacation switch is in the OFF (powered 
down  with  only  minimal  circuitry 
energized)  or AUTO  position  (amplifier 
is in the standby mode). When powered 
up (from AUTO) using the 3-30V AC/DC 
triggering or signal sensing feature, the 
LED will change to red, changing back 
to amber when there is no longer signal 
present  or  the  3-30V AC/DC  triggering 
is not energized. The LED will glow red 
whenever the rear panel power switch 
is in the ON and the GFA-6006/6002 is 
energized. 

The  Power  LED  indicates  that  there  is 
AC  voltage  being  fed  to  the  amplifier, 
but  it  does  not  signify  that  the  entire 
amplifier’s  circuits  are  in  operation. 

If,  for  example,  one  of  the  Thermal 
Protection  LEDs  glows,  that  amplifier 
channel  will  not  produce  sound 
even  though  the  Power  LED  may 
still  glow.  Additionally,  the  internal 
power  transformer  is  provided  with  a 
thermostat  which  will  interrupt  power 
into the transformer if its temperature 
exceeds  125°C. This  high  temperature 
will  seldom,  if  ever,  be  encountered 
unless  the  amplifier  is  subjected  to 
abnormal conditions, such as operation 
into loads of less than 3 ohms at very 
high listening levels. If the AC Fuse has 
not failed, the Power LED is out, and the 
Thermal Protection LED does not glow, 

this would indicate that the thermostat 
within the transformer has opened.

Once  the  temperature  within  the 
transformer  decreases  to  a  normal 
level,  the  thermostat  will  reset  itself 
automatically  and  normal  operation 
will  resume.  If  you  are  to  avoid 
continually  tripping  the  thermostat  in 
the  transformer,  you  must  reduce  the 
sound  level  demands,  correct  the  load 
impedance of the loudspeakers, or both.

[2] Thermal Protection

The  GFA-6002/6006  are  provided  with 
a  thermal  protection  circuit  which  will 
shut  down  the  individual  amplifiers 
if  its  heatsink  temperature  reaches 
85°C. The Thermal Protection LEDs will 
light  whenever  the  thermal  protection 
circuit in its respective channel has been 
triggered and the amplifier is inoperative. 
The  thermal  protection  circuitry  will 
typically be triggered by very high power 
demands  into  impedances  much  lower 
than the amplifier is capable of driving 

at those levels. If any amplifier channel’s 
output through the loudspeaker(s) ceases 
abruptly and its Thermal Protection LED 
glows,  you  will  know  that  its  heatsink 
temperature  has  become  unacceptably 
high and the circuitry is protecting the 
amplification  devices.  Please  note  that 
the  Power  LED  will  remain  on  and  the 
amplifier  will  still  be  energized.  Once 
the temperature of the heatsink(s) drops 
to a safe operating level, that amplifier 
will automatically resume operation.

Activation  of  the  Thermal  Protection 
circuitry  in  any  of  the  channels  of 
amplification  in  the  GFA-6002/6006  is 
an  indication  that  the  amplifier  has 

been  over-driven  or  that  the  load  the 
loudspeakers  are  presenting  to  the 
amplifier  is  unreasonably  low.  If  you 
wish  to  prevent  recurrent  activation 
of the thermal protection circuitry, you 
must reduce the volume-level demands 
or correct the load impedance condition 
which may be causing activation of this 
circuitry.

[3] Distortion Alert

The  Distortion  Alert  circuit  is  a 
unique  ADCOM  distortion  detection 
system  which  reads  all  forms  of 
non-linear  distortion  such  as  THD,  IM, 
slew-induced,  “clipping,”  etc.  The 
Distortion  Alert  LEDs  will  light  when 
distortion  reaches  approximately  1% 
regardless  of  impedance,  voltage/
current  phase  angle  or  the  reactance 
of  the  loudspeakers  which  the 
amplifier  is  driving.  Sometimes,  when 
the  amplifier  is  in  use,  the  LEDs  may 
occasionally flicker during high volume 
listening, particularly if you are driving 

low  impedances.  This  flickering  is 
no  cause  for  concern.  The  LEDs  are 
simply warning you that the amplifier is 
approaching its maximum power output 
into the particular loudspeakers you are 
using. If, however, the Distortion Alert 
LEDs  glow  brightly  or  are  illuminated 
most  of  the  time  during  playback, 
you are over driving the amplifier and 
should turn down your volume control to 
reduce the listening level. Otherwise, it 
may cause the Thermal Protection to be 
activated or, in extreme cases, damage 
your loudspeakers.

1

2

3

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

8

9

ADCOM GFA-6006/02 Owner’s Manual |

Description of Unit:

Rear Panel

[4] Inputs & [5] Outputs

The  audio  inputs  and  outputs  for  the 
GFA-6002  and  GFA-6006  are  through 
high-quality,  gold-plated  RCA  jacks  to 
minimize high-frequency losses, noise, 
etc. They will accept standard RCA-type 
plugs, one for each of the channels. To 
insure  that  the  performance  designed 
into  the  amplifier  is  preserved,  you 
should  use  the  highest  quality  audio 
cables possible. 

The GFA-6002 and 6006 feature inputs 
and  outputs  for  each  channel  to 
allow “daisy-chaining” of channels or 
additional amplifiers in an installation. 
To  direct  signal  from  one  channel  to 
another, connect an appropriate cable 
(RCA to RCA, male to male) from the 
output of one channel to the input of 
the desired channel. 

In  bridged  operation  (see  Bridged 
Operation) 

only 

the 

Bridged 

Mono  Input  is  to  be  used.  On  the 
GFA-6006,  bridged  mono  inputs  are 
channels 1,3, and 5. On the GFA-6002, 
bridged mono input is channel 1. For 
“daisy-chaining”  the  corresponding 
outputs for these channels are active.

[6] Input Level Adjustment

Each  channel  has  an  input  level 
adjustment.  The  purpose  of  this 
adjustment  is  to  balance  levels 
in  installations  where  physical 
circumstances  may  create  a  large 
difference  in  volume.  Turn  the 
level  control  to  the  fully  clockwise 
position  for  maximum  sensitivity; 
turning the control counter clockwise 
reduces  sensitivity.  Use  a  small 
blade  screwdriver  to  adjust.  In 
balanced  operation  only  the  input 
adjustments for channels 1, 3, and 5 
(GFA-6006)  or  channel  1  (GFA-6002) 

are effective (see BRIDGED OPERATION 
for more details).

[7] Amplifier Outputs

The  GFA-6006/6002’s  connections  to 
the  loudspeakers  are  made  through 
high-grade,  5-way,  binding  post 
terminals. There are two terminals for 
each  speaker,  which  are  colored  RED 
for  the  positive  (+)  output  and  BLACK 
for the negative (-) output. The binding 
posts will accept a variety of connector 
types; the most secure and prevalent of 
these is the “U”-type spade connectors 
(at  least  0.25”  wide  and  maximum 
width of 0.57”). The terminal will also 
accept  bare  wire  (up  to  AWG10)  and 
“banana” type plugs (single or dual).

In  connecting  the  amplifier  to  the 
loudspeaker,  it  is  vital  to  maintain 
proper  polarity  (positive  to  positive, 
negative  to  negative)  in  stereo 
operation. On the GFA-6006/6002, the 
positive  terminal  is  color  coded  RED 

4

5

8

6

7

9 10 11 1

GFA-6006 Rear Panel

GFA-6002 Rear Panel

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

10

11

ADCOM GFA-6006/02 Owner’s Manual |

and  labeled  “+,”  and  the  negative  is 
color coded BLACK and labeled “-”. The 
positive terminal on the speaker will be 
color  coded  RED,  or  will  be  labeled 
“+,” “pos,” “positive,” “8 ohms,” or “4 
ohms.”  The  negative  terminal  on  the 
speaker will be color coded BLACK, or 
will be labeled “-,” “neg,” negative,” 
“C,” “Common,” “G,” or “ground.”

Note: Bridged operation requires different 
loudspeaker connections. For details see 
the section Bridged Operation.

[8] Bridged Operation

In  bridged  operation  the  output  of 
two  stereo  amplifier  channels  are 
“combined”  to  drive  one  monophonic 
speaker.  In  the  bridged  mode  the 
GFA-6002 and 6006 wattage capability 
increases  to  175  Watts  at  8  ohms 
per  bridged  channel.  The  GFA-6006 
allows  for  any  of  three  adjoining 
“pairs”  of  amplifiers  to  be  bridged. 
For  input  directions  see  the  section 
Audio  Signal  Inputs  and  Outputs.  To 
engage  bridged  operation  for  a  pair 
of  amplifier  channels,  switch  the 
corresponding  toggle  switch  to  the 
bridged  position.  In  bridged  operation 
the  proper  loudspeaker  connection  is 
to  the  POSITIVE  (+)  terminals  of  each 
of  the  pair  of  bridged  channels.  Do 
Not  connect  the  Negative  (-)  speaker 
terminals  under  any  circumstances  in 
the bridged mode.

[9] 3-30V AC/DC Triggering

The  GFA-6002  and  GFA-6006  are  very 
high power amplifiers and as such must 
be directly connected to the wall outlet 
or  an  appropriate  surge  protector  or 
AC  line  conditioner.  It  must  never  be 
connected  to  the  “switched”  outlets 
on  the  rear  panel  of  a  pre-amplifier. 
Usually,  this  would  mean  that  when 
you turn on/off your pre-amplifier you 
would have to turn on/off your power 
amplifier separately. We have, however, 
provided  the  ability  to  control  the 
OFF/ON  function  (actually  “powering 
up” from standby) of the amplifier by 
a  12-Volt  DC  output  jack  on  the  rear 
of  certain  ADCOM  pre-amplifiers  and 
tuner  pre-amplifiers.  When  using  this 
feature  the  rear  panel  Power  Switch 
must be left in the in “auto” position. 
To connect, you will need a mono-mini 
phone  plug  to  a  mono-mini  phone 
plug  cable  of  appropriate  length  (not 
included) to reach from the rear panel 
jack of the amplifier to the rear panel 
of  the  pre-amplifier.  Contact  your 
dealer  for  information  on  using  this 
feature  with  ADCOM  and  other  brand 
pre-amplifiers.  Although  12V  DC  is 
optimal,  the  circuit  will  operate  from 
approximately 3 to 30V AC or DC, not to 
exceed  250mA.  The  center  conductor 
(tip) is positive. When using the 3-30V 
AC/DC triggering method the unit will 
return  to  standby  approximately  two 

and one half minutes after the signal is 
no longer present.

Audio Signal Sensing

Alternately, the sensing of audio signal 
can  turn  on  the  6002/6006  amplifier. 
Any  time  the  amplifier  detects  the 
presence  of  an  incoming  audio  signal 
it will “power up” from standby. Please 
note  that  the  speed  of  “turn  on”  by 
AC/DC  triggering  and  audio  sensing  is 
different.  AC/DC  triggering  is  slightly 
faster.  When  using  the  signal  sensing 
method, the unit will return to standby 
approximately two and one half minutes 
after  the  signal  is  no  longer  present. 
An  incoming  signal  level  of  5-7  mV  is 
required to trigger this sensing method.

[10] AC Fuse

The  AC  Fuse  protects  the  electronic 
circuits  of  the  GFA-6002/6006.  This 
fuse, normally, will fail only if there is 
an overload within the GFA-6002/6006. 
It  may,  however,  fail  if  the  amplifier 
attempts  to  deliver  very  high  power 
into very low-impedance loudspeakers. 
In  either  case,  BE  SURE  TO  REPLACE 
THE  AC  FUSE  ONLY  WITH  AN  EXACT 
REPLACEMENT FUSE.

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

10

11

ADCOM GFA-6006/02 Owner’s Manual |

The proper fuse values are:

GFA-6002 for 120 volt operation

Fuse Rating: 5 Amp 250 Volt
Buss®: AGC-5/250V
Littlefuse®:(3AG) 312005/250V

GFA-6002 for 230 volt operation

Fuse Rating: 3 Amp 250 Volt
Buss®: AGC-3/250V
Littlefuse®:(3AG) 312003/250V

GFA-6006 for 120 volt operation

Fuse Rating: 12 Amp 250 Volt
Buss®: AGC-12/250V
Littlefuse®:(3AG) 3120012/250V

GFA-6006 for 230 volt operation

Fuse Rating: 6 Amp 250 Volt
Buss®: AGC-6/250V
Littlefuse®:(3AG) 312006/250V

Before  attempting  to  replace  a  failed 
fuse, be certain to unplug the AC Power 
Cord from the AC wall outlet to prevent 
possible  electrical  shock.  Replace  the 
AC fuse only with one identical in type 
and rating as printed on the rear panel. 
DO  NOT  USE  ANY  SUBSTITUTE  FUSES 
WITH  DIFFERENT  RATINGS  OR  VALUES. 
Failure to observe this precaution may 
cause serious damage to the amplifier 
circuits, may create a hazard fire, and 
may void the warranty.

If  the  Power  LED  does  not  glow,  it 
may  be  an  indication  that  the  AC 
fuse  has  blown.  If  you  are  using  the 
12V  DC  Triggering  feature  it  may  be 

possible  that  there  is  a  problem  with 
that  connection.  To  determine  if  the 
problem  is  caused  by  a  malfunction 
in  the  12V  DC  system,  remove  the 
small  plug  inserted  into  the  I2V  DC 
Triggering  jack.  Press  the  front  panel 
power  switch  to  turn  off  the  amp, 
and  immediately  re-press  the  power 
switch. If the problem is caused by the 
12V DC triggering circuit the amp will 
turn on and the LED will glow. DO NOT 
attempt repair of the 12V DC system. If 
you are not sure or the amplifie displays 
other  symptoms,  please  consult  the 
RESOLVING PROBLEMS section.

Fuse Replacement

Since  the  fuse  has  a  ceramic  body 
and  you  cannot  visually  examine  the 
fuse element, it is suggested that you 
replace it with an identical substitute 
or bring the fuse to your ADCOM dealer 
so they may check its integrity.

[11] AC Power Cord

The AC cord provides power to operate 
all  the  GFA-6002/6006’s  circuits.  Its 
plug  can  be  connected  to  a  standard 
wall outlet provided the outlet supplies 
a  voltage  compatible  with  the  power 
requirements printed on the rear panel 
of the GFA-6002/6006.

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

12

13

ADCOM GFA-6006/02 Owner’s Manual |

Troubleshooting

Use  the  troubleshooting  notes  above  to  solve  common 
situations that don’t require professional attention. If the 
steps stated in possible solution do not resolve your prob-
lem,  then  please  contact  your ADCOM  dealer  or  call  the 
ADCOM  customer  service  department.  Any  problems  not 
covered  here  should  be  brought  to  the  attention  of  your 
ADCOM dealer or ADCOM customer service department.

A  special  note  on  “hum:”

  When  there  is  a  low-volume 

“hum”  audible  throughout  your  speakers,  even  with  the 
main  volume  turned  all  the  way  down,  you  have  a  com-
mon phenomenon known as a “ground loop.” A ground loop 
is  basically  a  difference  in  ground  voltages  between  two 
or  more  components  which  are  connected  electrically  and 
which creates multiple current paths where there must only 
be  one.  This  difference  in  potentials  creates  a  60Hz  low-
level sound (approximately a low A), that seems to “hum.”
It can be caused by adding new components to your system, 
but that does not imply there is anything electrically wrong 
with any new component. With the advent of audio/video 
and home theater systems, the problem has become com-
monplace.  Generally,  the  cause  is  the  Cable-TV  incoming 
signal line. This new incoming line may add an additional 
ground  at  a  different  potential  to  the AC  line  ground  of 
your  other  equipment  (refer  to  note  I  and  2,  to  trouble-
shoot a hum problem).

Note  1:

  Cable  TV  systems  can  sometimes  contribute  to 

ground  loop  problems  which  cause  “hum.”  To  determine 
if your cable system is the contributing factor, disconnect 

the Cable-TV incoming signal line (round, 75Ω) at the wall, 
or the first component the cable is connected to (i.e. the 
cable  box,  or  VCR).  If  the  hum  is  no  longer  present,  you 
must insert a “75Ω ground loop isolator” before reconnect-
ing the line. You should check with your ADCOM dealer to 
obtain  one.  If  the  “75Ω  ground  loop  isolator”  works  only 
partially or not at all, then please read note 2 to complete 
the troubleshooting procedure.

Note 2:

 Make sure that the power amplifier is at least 6” 

from processor or other equipment using microprocessors. 
Usually  putting  another  component  between  them  is  suf-
ficient  to  minimize  the  hum.  If  this  does  not  reduce  the 
hum,  turn  the  system  off  and  disconnect  all  Inputs  from 
the amplifier. If the hum still persists, then your dealer or 
service center must examine the unit/system. If the hum 
disappears, try another set of RCA cables. Connect one RCA 
cable at a time to see if one specific cable is responsible. 
If any or all cables cause the hum to appear, then the unit 
should be evaluated for proper operation by your dealer or 
authorized service center. Please see our website or call us 
for a list of authorized service centers in your area.

Servicing

ADCOM  has  a  technical  service  department  to  answer 
questions pertinent to the installation and operation of your 
unit. In the event of difficulty, please contact us for prompt 
advice.  If  your  problem  cannot  be  resolved  through  our 
combined efforts, we may refer you to an authorized repair 
agency, or authorize return of the unit to our factory. To aid 
us in directing you to a convenient service center, it would 

SYMPTOM 

POSSIBLE REASON  

POSSIBLE SOLUTION

Power LED does not 

AC Power Cord(s) not plugged in. 

Plug in AC Power Cord(s).

glow. No sound 

AC Fuse(s) failed. 

Replace AC Fuse(s).

 

Transformer thermal protection engaged. 

Wait until unit cools down. It will reset.

 

I2V DC triggering malfunctioning. 

Reset power switch manually. Check

 

 

connection of 12V DC trigger at source.

Power LED glows, 

Preamp or source unit is not on. 

Make sure whole system is on.

but no sound 

Connections in rear of amp are loose. 

Verify all connections on rear of amp.

One channel not 

INPUT(s) or OUTPUT(s) connector 

Verify both connections on that channel.

producing sound 

disconnected or loose.

 

Speaker disconnected. 

Verify connection at speaker.

 

Internal protection engaged. 

Bring to Dealer or Service Center.

Hum from all speakers 

Ground loop (difference in ground voltages 

If Cable TV is present (see Note 1).

at any volume 

between components). 

If Cable TV is not present (see Note 2).

Hum from all speakers 

Problem with source unit (CD, tape, etc.), 

Try different source (tuner, tape, etc.)

(hum goes up or 

or RCA cable connecting that source unit 

and/or different RCA cable.

down with volume) 

to the preamp.

Hum from the amplifier 

Some major appliance, dimmer, halogen or 

Make sure all appliances, dimmers and

itself 

fluorescent light is creating interference. 

suspect lights are off.

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

12

13

ADCOM GFA-6006/02 Owner’s Manual |

be helpful if you indicate which major city is accessible to 
your home.

Please address mail inquires to:
ADCOM Service
8541 East Anderson Drive
Scottsdale, Arizona 85255 USA

Phone, Fax or Email inquires to:
Voice: (480) 607-2277 or Fax: (480) 348-9876
Monday through Friday, 8:00 AM to 4:00 PM MST
Email: service@adcom.com

For fax inquires, please include a return fax number for the 
reply. When calling or writing about your ADCOM product, 
be  sure  to  note  and  refer  to  its  serial  number  as  well  as 
the  date  of  purchase  and  the  dealer  from  whom  it  was 
purchased.  In  any  communications  to  us,  please  include 
a  daytime  phone  number  where  we  may  reach  you.  In 
the  event  the  unit  must  be  returned  to  our  factory  for 
service,  you  will  be  instructed  on  the  proper  procedure 
when you call or write for a return authorization. 

Under no 

circumstances should your unit be shipped to our factory 
without prior authorization, or packed in other than its 
original carton and fillers.

If the original shipping carton and its fillers have been lost, 
discarded, or damaged, a duplicate carton may be obtained 
from our service department for a nominal charge.
Always ship prepaid via United Parcel Service (UPS) or other 
approved  carrier.  Do  not  ship  via  parcel  post,  since  the 
packing  was  not  designed  to  withstand  rough  parcel  post 
handling.  Improper shipment of the product will void your 
warranty coverage.

Warranty

ADCOM, a division of Klein Technology Group, LLC, makes 
the following limited warranties. These limited warranties 
extend to the original purchaser or any person receiving this 
product as a gift from the original purchaser and to no other 
purchaser or transferee. 

There is no warranty provided by 

ADCOM for products purchased from unauthorized outlets 
or dealers or from previous owners.
Limited Five Year Warranty (Home, Non-Commercial Use Only)

ADCOM warrants this product against defects in materials or 
workmanship for a period of five (5) years after the date of 
original retail purchase from an ADCOM authorized dealer. 
During this period, ADCOM will repair or replace a defective 
product or part, at our option, with a new or refurbished 
product or part without charge to you, as long as you follow 
the procedures listed below.

Limited Ninety (90) Day Warranty (Commercial Use Only)

ADCOM warrants this product against defects in materials or 
workmanship for a period of ninety (90) days after the date 
of  original  purchase  from  an  ADCOM  authorized  dealer. 
During this period, ADCOM will repair or replace a defective 
product or part, at our option, with a new or refurbished 
product or part without charge to you, as long as you follow 
the procedures listed below.
All  implied  warranties,  including  implied  warranties  of 
merchantability  and  fitness  for  a  particular  purpose  are 
limited in duration to the duration of the warranty period.
This  warranty  excludes  all  incidental  and  consequential 
damages,  unless  contravened  by  state  law. This  warranty 
gives  you  specific  rights  and  you  may  have  other  rights 
which vary from state to state.
No  person,  agent,  distributor,  dealer,  or  company  is 
authorized to change, modify or extend the terms of these 
warranties in any manner whatsoever.

Your Responsibilities

The above warranties are subject to the following conditions:
(1) You must retain and present your dated invoice or bill 
of sale to provide proof of original purchase from an ADCOM 
Authorized Dealer and coverage under the warranty period.
(2)  You  must  notify  us  within  ten  (10)  days  after  you 
discover a defective product or part.
(3) All warranty servicing of this product must be done by 
ADCOM or an authorized ADCOM Service Center.
(4)  This  warranty  is  only  valid  if  this  product  has  been 
purchased and used in the United States. Warranty coverage 
for  products  purchased  and  used  outside  of  the  United 
States is provided by local ADCOM authorized distributors.
(5)  Charges  by  third  parties  for  set-up,  installation, 
adjustments,  shipment,  insurance,  and  other  charges  are 
not covered by this warranty.
(6)  This  warranty  extends  only  to  defects  in  material  or 
workmanship  as  limited  above  and  does  not  extend  to  any 
product or part which has been lost or discarded by you or 
to damage to products or parts caused by misuse, accident, 
Acts  of  God  such  as  lightning  or  fluctuations  in  electrical 
power, improper installation, improper maintenance or use in 
violation of instructions provided in this Owner’s Manual, or to 
products which have been altered or modified. This warranty 
does not extend to products which have had the serial number 
removed, altered, defaced, or rendered illegible.
(7)  Physically  damaged  products  are  not  covered  by  this 
warranty and will be returned as received without repair.

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

14

15

ADCOM GFA-6006/02 Owner’s Manual |

GFA-6002 Specifications

Power Rating (To IEC/CEA-490A Requirements)

  70 Watts continuous average power into 8 ohms at any frequency between 20Hz and 20kHz with all channels driven  
  at less than 1.0% THD.
  100 Watts continuous average power into 4 ohms at any frequency between 20Hz and 20kHz with all channels driven  
  at less than 1.0% THD.
  Bridged Power: 175 Watts continuous average power (one channel) into 8 ohms at any frequency between 20Hz and  
  20kHz with at less than 1.0% THD.

IM Distortion 

(SMPTE)

  1 watt to 70 watts into 8 ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   ≤ 0.05%
 

IM Distortion 

(CCIF, Any Combination from 4kHz to 20kHz)

  70 watts into 8 ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   ≤ 0.01%
 

Frequency Response @ 1 Watt into 8 Ohms

  10Hz to 20kHz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   +0, -0.25dB

Power Bandwidth

 

(-3d B)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5Hz to 130kHz

Dynamic Headroom Into 4 Ohms

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1.8 dB

Signal to Noise Ratio, “A” Weighted

  70 watts into 8 ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   ≥ 100dB
 

Gain

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  29dB

Input Sensitivity

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  variable

Input impedance

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   17k ohms

Damping Factor

  2OHz to 2OkHz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ≥ 400

Rise Time

  5kHz, 90V, peak-to-peak square wave, 20% to 80%. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2.7µS

Power Consumption (Continuous, All Channels Driven)

  Quiescent. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  30VA
  Maximum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   600VA
 

General

Power

 (available in 230VAC by special order). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  115VAC—50/6OHz

Chassis Dimension

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 

3” (76.2mm) x 17” (432mm) x 11.5” (292.1mm)

Maximum Dimensions

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3.5” (88.9mm) x 17” (432mm) x 12.5” (317.5mm)

Weight

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   18 lbs. (8.2kg)

Weight, Packed

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   21 lbs. (9.5kg)

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

14

15

ADCOM GFA-6006/02 Owner’s Manual |

GFA-6006 Specifications

Power Rating (To IEC/CEA-490A Requirements)

  70 Watts continuous average power into 8 ohms at any frequency between 20Hz and 20kHz with all channels driven  
  at less than 1.0% THD.
  100 Watts continuous average power into 4 ohms at any frequency between 20Hz and 20kHz with all channels driven  
  at less than 1.0% THD.
  Bridged Power: 175 Watts continuous average power (one channel) into 8 ohms at any frequency between 20Hz and  
  20kHz with at less than 1.0% THD.

IM Distortion 

(SMPTE)

  1 watt to 70 watts into 8 ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   ≤ 0.05%
 

IM Distortion 

(CCIF, Any Combination from 4kHz to 20kHz)

  70 watts into 8 ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   ≤ 0.01%
 

Frequency Response @ 1 Watt into 8 Ohms

  10Hz to 20kHz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   +0, -0.25dB

Power Bandwidth

 

(-3d B)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5Hz to 130kHz

Dynamic Headroom Into 4 Ohms

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1.8 dB

Signal to Noise Ratio, “A” Weighted

  70 watts into 8 ohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   ≥ 100dB
 

Gain

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  29dB

Input Sensitivity

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  variable

Input impedance

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   17k ohms

Damping Factor

  2OHz to 2OkHz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ≥ 400

Rise Time

  5kHz, 90V, peak-to-peak square wave, 20% to 80%. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2.7µS

Power Consumption (Continuous, All Channels Driven)

  Quiescent. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  45VA
  Maximum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1440VA

 

General

Power

 (available in 230VAC by special order). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  115VAC—50/6OHz

Chassis Dimension

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 

4.75” (120.7mm) x 17” (432mm) x 14.5” (368.3mm)

Maximum Dimensions

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5.25” (133.4mm) x 17” (432mm) x 15.5” (393.7mm)

Weight

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  33 lbs. (15kg)

Weight, Packed

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  38 lbs. (17.2kg)

 


background image

|  ADCOM GFA-6006/02 Owner’s Manual

16

ADCOM

A division of Klein Technology Group, LLC

8541 East Anderson Drive

Scottsdale, Arizona 85255

Voice: (480) 607-2277

Fax: (480) 348-9876

http://www.adcom.com

 GFA6002_06_manual_v1