ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

 
 
 

 

 
 

 

      

ACUO 9O8 Serie

 

 

 

 

 
 
 

AEV On Air broadcast console 

 
 
 
 
 
 
 
 
 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

 

Guarantee 

The equipment is warranted for a period of 2 years from the date of invoice (ex-works). The 
warranty does not cover faults provoked by carelessness, natural causes and parts subject 
to wear. In addition, the cost of shipment is not covered. The warranty will be voided if the 
equipment is mishandled. 

 

Technical Support 

If you require technical support, contact AEV SERVICE giving a clear and concise account of 
your speciic problem. Quote the serial number of your equipment by referring to the AEV 
nameplate attached to the equipment itself as this is the most important piece of information 
to be provided. 
Telephone: +39 051 6630904 Fax: +39 051 893605 
 

Factory Service and Repairs 

If problems arise while the equipment is being installed, consult this manual and check that 
the installation is being carried out properly. If the problems still cannot be solved, call the AEV 
SERVICE Department for further information. If the problem is a minor one we can a telephone 
call will probably sufice. If, on the other hand, the equipment is to be shipped to AEV for 
service or repairs.  
 

Shipping Instruction 

When shipping the equipment to AEV, use the original package in order to be certain that it will 
be fully protected during handling. If you need the original package, call us for a new one. 
If you ship the equipment in a different packing container, take care to provide a double 
package by interposing padding material between the two containers in order to fully protect 
the equipment during shipment. The package should be marked “FRAGILE” in red. 
Remember that the RMA number must be clearly visible on the package. If it is not, the 
equipment will not be accepted. 
 

IMPORTANT: 

Carefully read this paragraph as it contains important instructions concerning 

operator safety and directions regarding the installation, operation and maintenance of the 
equipment. 
Failure to observe the safety instructions and information given in this manual 

constitutes an 

infringement of the safety rules and design specifications provided for this piece of 
equipment

AEV Broadcast Srl declines all responsibility 

if any one of the safety rules given here in is 

not observed. 

AEV Broadcast Srl declines all responsibility 

if the end-user resells the product. 

The equipment is to be used by people capable of operating it in a trouble-free manner and 

it 

is assumed that they are aware of the following safety rules. 

• Keep this manual with the utmost care and close at hand so that it can be consulted 
whenever needed 
• After unpacking the equipment, check it for condition. 
• Avoid banging the equipment. 
• The packing material (plastic bags, polystyrene, nails, etc.) must never be left within the 
reach of the children, as 

these items are potential sources of danger

• Do not use the equipment in places where the temperature is not within the recommended 
range, as specified by the manufacturer. 
• Before connecting the equipment, make sure the nameplate specifications correspond to the 
mains electricity supply (the nameplate is located on the equipment enclosure). 
• Do not remove the sticker from the equipment as it contains important specifications and the 
relevant serial number. 
• To join the equipment to the mains supply, use the power cord purchased with the 
equipment. 
• The equipment must be used only for the purpose it was designed for. 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

• Abuse or misuse of the equipment is 

extremely dangerous 

for people, pets and property. 

The manufacturer declines all responsibility for damage and injury resulting from 

improper 

use 

and 

mishandling

• Certain basic safety rules must be observed when using electrical equipment, in particular: - 
Never touch the equipment with wet and/or damp hands or other parts of the body. 
- Keep the equipment away from drops of water or sprinkling systems. 
- Never use the equipment near high heat sources or explosive material. 
- Do not introduce any extraneous matter into the equipment. 
- Do not allow children or untrained people to use the equipment. 
• Before cleaning or servicing the equipment outside, disconnect it from the supply and wait at 
least 2 seconds before working on it, as recommended by current safety regulations. 
• In the event of faults and/or improper operation, turn off the equipment, shut off the 
electrical power and call your dealer. 
• Do not attempt to make repairs and/or adjustments when covers/guards or circuit boards are 
to be removed. 
• Blown fuses inside the power supply indicate that there may be a fault in the power supply 
itself. The fuses must be replaced by qualified and authorised persons. It is advisable to call 
your nearest dealer. 
• Call your dealer for any repairs and be certain original spare parts are used. 

Failure to observe this rule may adversely affect the safety level of your equipment

• The equipment is to be connected to the mains supply and provided with adequate and 
efficient earth conductors. 
• The electrical wiring must be done in compliance with current electrical codes CEI 64-8 
“Electrical specification for domestic buildings”. 
• When installing, leave a clearance of at least 1 cm around the equipment to allow air to pass 
freely. 

NOTE. This piece of equipment has been manufactured to the highest standards of 
workmanship. It must be used properly and serviced as recommended to ensure 
long-term dependable operation. 

The installation must be done in order to be able to guarantee an easy access to the cable of 
feeding. 
The device of dissection of the equipment is the cable of feeding, so it must be unconnected 
from the equipment every time it is necessary to do any type of maintenance. 
 

 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

 

Contents 

Guarantee....................................................... 2 

Technical Support .............................................. 2 

Factory Service and Repairs .................................... 2 

Shipping Instruction ........................................... 2 

Precautions .................................................... 3 

Contents ....................................................... 4 

Features ....................................................... 5 

Input functions and channels ................................... 5 

Input channel configuration .................................... 5 

Outputs ........................................................ 6 

External controls .............................................. 5 

Monitoring ..................................................... 5 

Input configuration ............................................ 5 

Input setting .................................................. 5 

Master outputs.................................................. 6 

External control................................................ 6 

Monitoring ..................................................... 6 

Micro - Line channel ........................................... 7 

Digital - Line Module .......................................... 8 

USB - Line Module .............................................. 9 

Monitoring section ............................................ 10 

Telephone hybrid section ...................................... 10 

Control Room & Control Studio section ......................... 11 

Master setupu section ......................................... 11 

Rear Panel — Connections ...................................... 12 

RJ connectors pin out ......................................... 14 

Logic GPI/O port .............................................. 14 

Telephone hybrids - operation

.................................. 16

 

Technical specifications ...................................... 17 

 
 

 
 
 
 
 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

Features 
 

audio inputs: 

8 double-channels 
balanced Micro and line inputs, digital AES/EBU, USB audio I/O interface 
 

Faders: 

Faders (100 mm) with A/B input selector, 3 bands tones control

 

on each input. 

 

Input functions and channels 
 

-

 

Four Microphone inputs      ( MIC1,...,MIC4 ) 

-

 

Eitgh stereo line inputs       ( LIN1,......LIN8 ) 

-

 

Two digital AES/EBU input  ( DIG1, DIG2 ) 

-

 

Two USB audio inputs        ( USB1, USB2 ) 
 

Input channels configuration: 

 

Channel 1 : MIC1 /  LINE1 
Channel 2 : MIC2 /  LINE2 
Channel 3 : MIC3 /  LINE3 
Channel 4 : MIC4 /  LINE4 
Channel 5 : DIG1 /  LINE5 
Channel 6 : DIG2 /  LINE6 
Channel 7 : USB1 / LINE7 
Channel 8 : USB2 / LINE8 

 

Input setting 
 

All settings are independent for each input, via encoder. 
Channel setting: 
- Gain / Level adjustment 

 

 

-12÷+12 dB 

- Input balance 

 

 

 

 

-12÷+12 dB 

- tone equalizer High, Medium , Low  

-14÷+14 dB 

- Private tel   

 

 

 

 

OFF/ON 

- Control Studio 

 

 

 

 

OFF/ON 

- PGM assignement  

 

 

 

SPEECH/MUSIC 

- C. Room Mute 

 

 

 

 

OFF/ON 

- ST MU  

 

 

 

 

 

OFF/ON 

- Tally   

 

 

 

 

 

OFF/ON 

- Talk back on C.Studio   

 

 

OFF/ON 

- Phantom Power (only for Micro inputs)  OFF/ON 
 
Also you can to select the Bus assignment pushing the following buttons: 

-

 

PGM 

-

 

UTL 

-

 

AUX 

-

 

CUE 

 
 

 
 
 
 
 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

Master Outputs 
 

PGM

:Analog balanced stereo with XLR connectors 

UTL

: Analog balanced stereo with XLR connectors 

AUX: 

Analog balanced stereo with RJ45 connector 

PGM Dig: 

digital AES/EBU stereo with RJ45 connector 

UTL  Dig: 

digital AES/EBU stereo with RJ45 connector 

 

Auxiliary outputs 
Control Room: 

Analog balanced stereo with RJ45 connector 

Control Studio: 

Analog balanced stereo with RJ45 connector 

Mute C. Studio: 

Analog balanced stereo with RJ45 connector 

Headphone : 

Analog stereo with Jack 6,3 mm connector 

 

Auxiliary input 
External : 

Analog balanced stereo with RJ45 connector 

 

 

External controls 

- Remote Fader with logic controls, (START/STOP) with RJ45 connector 
- GPI Opto-isolated logic inputs 
- GPO Opto-isolated logic outputs 
 

Monitoring 

- Level control for headphone, Control Room, Control Studio mutable 
- External inputs for Monitor 
- Headphone with integrated amplifier 
- double stereo digital VU-Meter on the TFT display PGM ( fixed ) SEL ( EXT, UTL, AUX ) 
 

 

 
 
  

 
 
 

inputs  

encoder 

channels fader 

section 

C.Room & 

C.Studio section 

Telephone hybrid 

section 

Encoder Master 

VU display  

section 

Digital TFT 

display 

start channel 

 display 

channels 

assignement 

busses 

assignement 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

Micro - Line channel ( channels 1 – 4 ) 

 

All controls on the Micro-Line input channel are described below. 
 
 

       

 

 
 
 
 
 
 
 

 
 
 
 

 
 

– START lamp, it 

lights when the channel fader is 

active 

 

– knob jog ; directly it select the Gain input level the 

range is -12 ÷ +12 dB; 

 
 in sequence, the following commands: 
 
1th push-buttom Balance adjust (-12 ÷ +12 dB) 
 
2th push-buttom Treble band adjust (-14 ÷ +14 dB) 
 
3th push-buttom Middle band adjust (-14 ÷ +14 dB) 
 
4th push-buttom Bass band adjust (-14 ÷ +14 dB) 
 
5th push-buttom Private Tel active (OFF/ON) 
 
6th push-buttom TB Studio to C.Room active (OFF/ON) 
 
7th push-buttom PGM bus selection ( Speech/ Music) 
 
8th push-buttom Control Room Mute active (OFF/ON) 
 
9th push-buttom Mute C.Studio active (OFF/ON) 
 
10th push-buttom Tally active (OFF/ON) 
 
11th push-buttom TB Regia to C. Studio active 

(OFF/ON) 

 
12th push-buttom Phantom power for the  
condenser microphone active ( OFF/ON ) 
  

– MIC to activate the microphone source (only with 

the channel in STOP) 

microphones. 
 

– LINE to activate the line source (only with the 

channel in STOP) 

 

– PGM Button for routing the channel to the PGM bus. 

 

– UTL Button for routing the channel to the UTL bus. 

 

– AUX Button for routing the channel to the AUX bus. 

 

- Button enabling the preview CUE. 

 

- Fader.

 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

Dig - Line Module ( channels 5 – 6 ) 

 

All controls on the Dig-Line input channel are described below. 
 

    

 

 
 
 
 
 
 
 

 
 
 

 
 

 

– START lamp, it 

lights when the channel fader is 

active 

– knob jog ; directly it select the Gain input level 

the range is -12 ÷ +12 dB; 

 
 in sequence, the following commands: 
 
1th push-buttom Balance adjust (-12 ÷ +12 dB) 
 
2th push-buttom Treble band adjust (-14 ÷ +14 dB) 
 
3th push-buttom Middle band adjust (-14 ÷ +14 dB) 
 
4th push-buttom Bass band adjust (-14 ÷ +14 dB) 
 
5th push-buttom Private Tel active (OFF/ON) 
 
6th push-buttom TB Studio to C.Room active 

(OFF/ON) 

 
7th push-buttom PGM bus selection ( Speech/ Music) 
 
8th push-buttom Control Room Mute active 

(OFF/ON) 

 
9th push-buttom Mute C.Studio active (OFF/ON) 
 
10th push-buttom Tally active (OFF/ON) 
 
11th push-buttom TB Regia to C. Studio active 

(OFF/ON) 

 

– DIG to activate the digital AES/EBU source (only 

with the channel in STOP) 
 

– LINE to activate the line source (only with the 

channel in STOP) 
 

– PGM Button for routing the channel to the PGM 

bus. 
 

– UTL Button for routing the channel to the UTL 

bus. 
 

– AUX Button for routing the channel to the AUX 

bus. 
 

- Button enabling the preview CUE. 

 

- Fader.

 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

USB - Line Module

 

( channels 7 – 8 )

 

All controls on the USB-Line input channel are described below. 
 
 
 
 

 

 
 

 
 
 
 
 
 
 
 
 

 

– START lamp, it 

lights when the channel fader is 

active 

 

– knob jog ; directly it select the Gain input level the 

range is -12 ÷ +12 dB; 

 
 in sequence, the following commands: 
 
1th push-buttom Balance adjust (-12 ÷ +12 dB) 
 
2th push-buttom Treble band adjust (-14 ÷ +14 dB) 
 
3th push-buttom Middle band adjust (-14 ÷ +14 dB) 
 
4th push-buttom Bass band adjust (-14 ÷ +14 dB) 
 
5th push-buttom Private Tel active (OFF/ON) 
 
6th push-buttom TB Studio to C.Room active (OFF/ON) 
 
7th push-buttom PGM bus selection ( Speech/ Music) 
 
8th push-buttom Control Room Mute active (OFF/ON) 
 
9th push-buttom Mute C.Studio active (OFF/ON) 
 
10th push-buttom Tally active (OFF/ON) 
 
11th push-buttom TB Regia to C. Studio active 

(OFF/ON) 
 

– USB to activate the digital usb source (only with the 

channel in STOP) 
 

– LINE to activate the line source (only with the 

channel in STOP) 
 

– PGM Button for routing the channel to the PGM bus. 

 

– UTL Button for routing the channel to the UTL bus. 

 

– AUX Button for routing the channel to the AUX bus. 

 

- Button enabling the preview CUE. 

 

- Fader. 

 
 

 
 


 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

10 

Monitoring section 

 

 

 
 
 
 

 

- Button for selecting the EXT input on 

Switched digital VUMeters. 
 

- Button for selecting the Master UTL 

output on Switched digital VU-Meters. 
 

- Button for selecting the Master AUX 

output on Switched digital VU-Meters. 

 
 

 

 

 

 

Telephone hybrids section 

 

                 

 

 
 
 
 
 

 
 
 
 
 
 

 
 
 

1A 

- HOOK button for telephone line 1 hook-up. 

1B 

- HOOK button for telephone line 2 hook-up. 

 

2A 

- Button for Stanby state for telephone line 1. 

2B 

- Button for Stanby state for telephone line 2. 

 

3A 

- Button for TX+ adjust for telephone line 1. 

3B 

- Button for TX+ adjust for telephone line 2. 

 
4A 

- Button for TX- adjust for telephone line 1. 

4B 

- Button for TX- adjust for telephone line 2. 

 

 
5A 

- Button for RX+ adjust for telephone line 1. 

5B 

- Button for RX+ adjust for telephone line 2. 

 
6A 

- Button for RX- adjust for telephone line 1. 

6B 

- Button for RX- adjust for telephone line 2. 

 
7A 

- Button for assigning the tel1 to the PGM bus. 

7B 

- Button for assigning the tel2 to the PGM bus. 

 
8A 

- Button for assigning the tel1 to the UTL bus. 

8B 

- Button for assigning the tel2 to the UTL bus. 

 
9A 

- Button for assigning the tel2 to the AUX bus. 

9B 

- Button for assigning the tel2 to the AUX bus. 

 
10A 

-Button for assigning the tel2 to the CUE 

bus. 

10B 

-Button for assigning the tel2 to the CUE 

bus. 
 

 
 

 
 

1A 

2A 

3A 

4A 

5A 

6A 

7A 

8A 

9A 

10A 

1B 

2B 

3B 

4B 

5B 

6B 

7B 

8B 

9B 

10B 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

11 

Room & Studio section 

 

 

 
 

Control Studio selection 

 

– Button for selecting the EXT input for 

routing it to the Control Studio output. 

- Button for selecting the master PGM output 

for routing it to the Control Studio output. 

- Button for selecting the master UTL output 

for routing it to the Control Studio output. 

- Button for selecting the master AUX output 

for routing it to the Control Studio output. 

- Button for selecting the CUE bus for routing 

it to the Control Studio output. 
 

 
Control Room selection 
 

– Button for selecting the EXT input for 

routing it to the Control Room outputs. 

- Button for selecting the master PGM output 

for routing it to the Control Room outputs. 

- Button for selecting the master UTL output 

for routing it to the Control Room outputs. 

- Button for selecting the master AUX output 

for routing it to the Control Room outputs. 

 

Talk Back  

 

10 

- Button to active the Talkback function to the 

Control Studio outputs. 

 

 

Talk back Regia to Studio

When the TB (talk back) button is pressed, the 
signal of the enabled microphone is sent to the 
Control Studio output. 
 

 

Channel with function talkback to studio 
(TBST: ON) 

 

Channel in STOP 

 
What happens:  

 

the Talk back button of the remote fader 

lights 

up

 

 

the previous selection of the Control Studio flashes

 

 

the audio signal present in the Control studio is 
replaced by the channel selected in TB 

 

 

Talk back Studio to Regia

 : 

(need the Remote Fader) 

 

Channel 

connected to the Remote Fader unit 

with 

talkback function activated (STCR: ON) 

 

Channel in STOP 

 
What happens when the remote TB (talk back) 
button is pressed:  

 

the Talk back button of ACUO 

flashes

 

 

the previous selection of the Control Room flashes

 

 

the audio signal present in the Control Room is 
replaced by the channel connected to the Remote 
Fader unit

 

 

the signal of the enabled microphone is sent 
to the Control Room output. 
 

 

 

Master setup 

 

Master knob jog ; directly it select the Gain headphone level, the range is -∞ ÷ +8 dB; 
in sequence, the following commands: 
1th push-buttom Control Room level (-∞ ÷ +8 dB) 
2th push-buttom Control Studio level (-∞ ÷ +8 dB) 
3th push-buttom PGM output level (-12 ÷ +12 dB) 
4th push-buttom External input level (-12 ÷ +12 dB) 
5th push-buttom CUE interlock (OFF/ON) 
6th push-buttom PGM Digital sample rate ( 32, 44.1, 48, 96 KHz ) 
7th push-buttom UTL  Digital sample rate ( 32, 44.1, 48, 96 KHz ) 

8th channel selection to associate the command I / O Start/Stop A (GPIO 1)  
9th channel selection to associate the command I / O Start/Stop B (GPIO 2)  
10th channel selection to associate the command Out Start/Stop C

 

10 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

12 

 

 

Rear panel – connections 
 

 

 
 

 

 

Microphone inputs connection 

 
 
 
 

 

 
 
 

 
 

Line inputs connection 

 
 
 
 

 

 
 
 
 

 
Outputs & Ausiliary connection 

 
 
 
 

 

 

 
 
 
 

 
 
 

 

– Microphone 1 input XLR F connector.  

- Trimmer adjusting the MIC 1 input level from 0 ÷ 

to +30 dB for very low volume microphones. 

– Microphone 2 input XLR F connector.  

- Trimmer adjusting the MIC 2 input level from 0 ÷ 

to +30 dB for very low volume microphones. 

– Microphone 3 input XLR F connector.  

- Trimmer adjusting the MIC 3 input level from 0 ÷ 

to +30 dB for very low volume microphones. 

– Microphone 4 input XLR F connector.  

- Trimmer adjusting the MIC 4 input level from 0 ÷ 

to +30 dB for very low volume microphones 

 
 
 
 

  

– Line 1 input RJ45 connector. 

 

10 

– Line 2 input RJ45 connector. 

11 

– Line 3 input RJ45 connector. 

12 

– Line 4 input RJ45 connector. 

13 

– Line 5 input RJ45 connector.  

14 

– Line 6 input RJ45 connector. 

15 

– Line 7 input RJ45 connector. 

16 

– Line 8 input RJ45 connector. 

 

 
 
 
 
 
 

17 

– Dig1 & Dig2 input RG45 connector.  

18

- Control Studio Mutable output RJ45 connector 

19 

– External input RG45 connector.  

20 

– Control Room output RJ45 connector. 

21 

– AUX output RJ45 connector 

22 

– Control Studio output RJ45 connector. 

23 

– PGM Dig & UTLDig input RG45 connector.  

24 

– Remote Fader RG45 connector.  

 
  

 

11 

13 

15 

10 

12 

14 

16 

17 

19 

21 

23 

24 

18 

20 

22 

 

Microphone inputs 

Line inputs 

Outputs & ausiliary 

Telephone 

line 

XLR Outputs 

Head/USB/Logic & PWS 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

13 

 
 
 
 

Telephone connection 

 
 

 

 

 

 
 
 
 
 

 

Outputs XLR connection 

 
 

 
 

 

 
 

 

 

 
 
 

Head/USB/Logic & PWS connections 

 
 
 
 
 

 

 
 
 

 

 
 

 

 

 

 

 
 
 

 
 
 
 
 
 
25

 - Connector RJ45 for telephone line 1. 

26

 - Connector RJ45 for telephone service 1. 

27

– Connector RJ45 for telephone line 2. 

28

– Connector RJ45 for telephone service 2. 

 
 
 
 

 
 
 
 
 
 
 
 
 
29

 - UTL left channel XLR connector. 

30

 - UTL right channel XLR connector. 

31 

- PGM left channel XLR connector. 

32 

- PGM right channel XLR connector. 

 
 
 

 
 
 

 

 
 
 
 

33 

– Logic I/O DB15 connector. 

34 

– PWS connector. 

35 

– Headphone jack 6,3 mm connector. 

36 

– USB 1 connector.  

37 

– USB 2 connector. 

38 

– USB serial connection. 

 

 
 
 
 
 
 
 

 

 
 

26 

28 

33 

34 

35 

36 

37 

38 

 

32 

31 

30 

29 

25 

27 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

14 

 

Line in /AUX/C.Room/C.Studio/Ext     
RJ45 pin out 

 

      

 

 

 
 

Digital Outputs RJ45 pin out 

 

      

 

 
 
 

 

Remote fader RJ45 pin out 

 

 

 

 
 
 

 

Tel line/ tel set  RJ45 pin out 

 
 

                                         

 

 
 

 

 

 

 
 

Logic I/O pin out 

 

 

            

 

 
 
 

 
 

 

 

 
1e 

– left channel + 

2e 

– left channel - 

3e 

– right channel + 

4e 

– GND  

5e 

– N.C. 

6e 

– right channel – 

7e 

– N.C. 

8e 

– N.C

 

 
 

1o 

– UTL dig + 

2o 

– UTL dig - 

3o 

– PGM dig + 

4o 

– GND  

5o 

– N.C. 

6o 

– PGM dig + 

7o 

– N.C. 

8o 

– N.C. 

 
 

1p 

– +5v 

2p 

– IN 

3p 

– Start/Stop L 

4p 

– Start/Stop S 

5p 

– Talk Back L 

6p 

– Talk Back S 

7p 

– GND 

8p 

– GND 

 
 
 
1t 

– N.C. 

2t 

– N.C. 

3t 

– N.C. 

4t 

– tel set 

5t 

– tel line 

6t 

– N.C. 

7t 

– N.C. 

8t 

– N.C. 

 
 
 
1–9 

– GPO1 Start/Stop A; Start=close, 

Stop=open 

2–10 

–GPO2 Start/Stop B; Start=close, 

Stop=open 

3–11 

– GPO Tally; (Start)+(Tally ON) 

4–12 

– GPO3 ; (Start) with selected channel 

5-13 

– GPI1 Start/Stop IN A ; Toggle 

6-14 

– GPI2 Start/Stop IN B ; Toggle 

7

      +5V 

8

      GND  

15

    GND 

 

1o      8o 

1p      8p 

1e      8e 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

15 

 

Logic GPI/O port 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

GPO 1 Out ( Start / Stop A)

 through the encoder master to the voice GPIO1 (Start 

/ Stop A) select the channel assignment, so when the channel will in Start,  the 
contact between 1 and 9 will close, with the channel in Stop  the contact is open .

 

 

 

GPO 2 Out ( Start / Stop B )

 through the Master encoder select GPIO2 (Start / 

Stop B) and select the channel assignment, so when the channel will put in Start, 
the contact between 2 and 10 will close , with the channel put in Stop the contact is 
open.

 

 

 

GPO Tally

 : Endcoder in each channel, through the Encoder, to the item TALLY set 

ON , so closes the contact between pins 3 and 11 will close when the channel is put 
in Start

 

 

 

GPO 3

 : Endcoder by the Master, under GPO3 select the channel assignment , so, 

the contact between pins 4 and 12 will close  when the channel will put in Start in, 
the contact will open when you put in Stop  the channel.

 

 

 

GPI 1 ( In Start/Stop A)

 : through the Master encoder select 

GPIO1 (Start/Stop 

A)

 and select the channel assignment, in which way , from the outside, through a 

circuit to activate the photo - coupler placed between the pins 5 and 13, states Start 
and Stop will alternate in the channel , the status of which will be remote using the 
control 

Out Start/Stop A 

 

 

GPI 2 ( In Start/Stop B ) 

through the Master encoder select 

GPIO2 (Start/Stop 

B) 

and select the channel assignment, in which way , from the outside, through a 

circuit to activate the photo - coupler place between pins 5:13 states will alternate 
start and stop of the channel , the status of which will be using the remote control 

Out Start/Stop A 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

16 

 

 
 
 
Telephone hybrids - operations 

 

 

Incoming Phone Call: 

HOOK

 button flashes 

 

 

Attach incoming call, press the 

HOOK

 key (it remains lit)

 

 

Telephone call on hold: 

 

o

 

buttom 

HOOK

 in ON

 

o

 

CUE

 (ON) of the bar phone selected 

 

o

 

PRIV TEL

 (ON) of the microphone channel

 

o

 

Regia Microphone in 

STOP

 

 

 

 

Meeting function:

 

o

 

(

STBY OFF

) enabled on the same bus hybrids 

TEL1

TEL2

 and possibly a 

channel with microphone 

 

o

 

to listen to audio on your phone to activate the corresponding bus C. Room 

(Regia) and / or C.Studio (studio).

 

o

 

PRIV TEL

 (ON) of the microphone channel

 

 
 

 

 

 

 


background image

 

 

ACUO 908 Serie  -  AEV ON AIR CONSOLE

     

 

 

AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  info@aev.eu 

 

   

17 

TECHNICAL SPECIFICATIONS 

 

Microphone Inputs 

Input configuration  

 

 

 

Electronically balanced 

Input Impedance   

 

 

 

200 Ω 

Sensitivity Level Range    

 

 

Adjustable from –70 ÷-40 dBu (Trimmer adj.) 

Input Level Range  

 

 

 

±12 dBu (Digital adj. step 0,5 dB) 

Maximum Input Level  

 

 

 

- 30 dBu 

Phantom Supply   

 

  

 

48 Vdc selectable 

100 mm Fader  

 

 

 

 

VCA Digital controlled

 

Connector    

 

 

 

 

XLR Female 

 
Line Inputs 

Input configuration  

 

 

 

Electronically balanced 

Input Impedance    

 

 

 

10 K Ω (600 Ω wired) 

Input Level Range  

 

 

 

±12 dBu (Digital adj. step 1,0 dB) 

Headroom    

 

 

 

 

+ 18 dBu 

100 mm Fader control    

 

 

VCA Digital controlled

 

Connector    

 

 

 

 

RJ-45 

 
Digital inputs 

Input configuration  

 

 

 

AES/EBU, IEC958,S/PDIF & EIAJ CP340/1201  

Sample Rate  

 

 

 

 

Automatic 32, 44.1, 48, 96 KHz converter 

100 mm Fader control 

 

 

 

VCA Digital controlled

 

Connector   

 

 

 

 

RJ-45 

 
Telephone Hybrid 

Input configuration  

 

 

 

Opto-coupled 

Input impedance    

 

 

 

600 Ω Bal 

Line Compensation  

 

 

 

Automatically (max 5 Km) 

Tx Level  

 

 

 

 

 

±12 dBu (Digital adj. step 0,5 dB) 

Rx Level Range  

 

 

 

 

±12 dBu (Digital adj. step 0,5 dB) 

Frequency response  

 

 

 

300 Hz ÷ 3400 Hz (-2 dB)  ; 300 Hz ÷ 3400 Hz (-1.5 dB) 

Distortion    

 

 

 

 

< 1.5 % 

Noise  

 

 

 

 

 

 -60 dB. 

 
Analog Outputs 

Output configuration 

 

 

  

Electronically balanced 

Output Impedance  

 

 

 

100 Ω 

PGM Output Level Range  

 

 

-12 ÷ +12 dBu 

Connector   

 

 

 

 

XLR male 

UTL/AUX Output Level Range   

 

0 dBu fixed   

Connector   

 

 

 

 

RJ-45 

C Room Mut.Output Lev.  

 

 

- 12÷ +12 dBu 

Connector   

 

 

 

 

RJ-45 

 
Digital Outputs 

Output configuration 

 

 

 

AES/EBU, IEC958,S/PDIF & EIAJ CP340/1201  

Sample Rate  

 

 

 

 

Automatic 32, 44.1, 48, 96 KHz converter 

Connector    

 

 

 

 

RJ-45 

 
Headphones 

configuration Type  

 

 

 

Stereo unbalanced (C.Room no Muted) 

Output Impedance  

 

 

 

50 Ω 

Connector    

 

 

 

 

JACK 6,3 mm 

 
Logic I/O 

Configuration 

 

 

 

 

Optic solid state relay 

Max Voltage  

 

 

  

 

50 Vdc/ac 

Max Current  

 

 

 

 

100 mA 

Connector   

 

 

  

 

DSUB 15 pole female 

USB Port 

 

 

 

 

 

2 x USB 2.0 interface 

 
Dimensions

   

 

 

 

 