background image

SHOWER

WATER HEATER

MODEL  BS 35 / 45 / 60

BS 35 E / 45 E / 60 E

 

OPERATION  AND 

 

INSTALLATION  INSTRUCTIONS

 


background image

2

     

Please read carefully

      Read these instruction

carefully before using the 

appliance and retain them for 

future reference.  If the appliance 

is passed on the third party please 

hand these instructions to the new 

user.

      -  This appliance is not 

        intended for use by 

persons (including children) with 

reduced physical, sensory or mental 

capabilities,  or  lack  of  experience 

and  knowledge,  unless  they  have 

been

given supervision or instruction 

concerning use of the appliance by 

a person responsible for their safety.

      -  Children should be 

        supervised to ensure that 

they do not play with the appliance.

This water heater must be installed (water and electrical installation), commissioned 

and serviced by approved service technicians in accordance with these instructions.

 


background image

Fig 1

Fig 2

Shower head level must not be higher than the unit

A

B

C

D

105 mm

360 mm.

212 mm

100 mm

360 mm 280 mm

9

8

7

Functions

Mounting dimensions

Fig 3

Fig 4

min. 4,5 mm

max. 10 mm

10

11

The cable bushing must be 
used to provide protection 
against the penertration of water.

The unit must be earthed !

Fixing method

Electrical connection

3

1. Installation instructions

 

for the qualitified installer

 


background image

4

Fig 5

Fig 6

13

14

15

12

a - Heating Element
b - Electronic control set 
     (Phase Cut)
c - ELSD Circuit 
d - Triac Set
e - Auto Thermostat
f - ELSD-Button Board
g - ELSD Sensor Coil

b

c

a

d

e

f

g

Fixing, cleaning

Wiring Diagram

1. Installation instructions

 

for the qualitified installer

 


background image

5

1.1  Description of the unit

The      AEG    BS    pressureless    (open)  small 
instantaneous water heater is a device for 
heating  water  for  shower.    The  electrical-
power is electronically controlled. The flow 
is  controlled by using the water valve (C). 
The  unit  switches  the  power  on  once  the 
flow volume reach 1.5-2 l/min. 
The “Power” light (A) indicates that the  unit  
is  switched on.   If  the temperature 
adjustment  rotary  (B)  switch  is  turned  to 
the left, it is  possible to take a cold shower 
(the heating will not be switched on).
The  BS  is  fitted  with  an  overheating 
protection device. In the event of overheating 
the heating power will be cut off.

1.2 The essentials-in brief (Fig. 1)

 

 

A  “Power” light   

 

B  Rotary control for temperature 

 

  adjustment

 

C  Water valve

 

D  Shower  accessories

1.3 Important information

 

 

The unit must not be put  

 

 

under pressure. The outlet of 

the unit is also used as a vent. A periodical 
scale removal is essential for the function 
of the shower head.

 

 

The unit is optional  equipped 

 

 

with an ELSD (Type BS...E only).  

It is recommended to test the ELSD one 
time per month.

How to test:

Switch on the electrical supply. Press the 
Test button, the Trip light will go on. 
Press the Reset button.

 

 

Warning!

 

 

If the Trip light activate after

reset or if the light activate during shower, 
never try to fix it. Contact your dealer for 
a check and repair. 
 

1.4 Care and Maintenance

All  that  is  needed  for  cleaning  is  a  damp 
cloth.    Do  not  use  any  abrasive  cleaning 
agents or agents containing solvents.

 

 

Maintenance work may only be

 

 

carried out by a qualified installer.

1.5 Hot water capacity

The  hot  water  capacity  depends  on  the 
power of the unit, the cold water tempera-
ture, and the flow volume

1. Installation instructions

 

for the qualitified installer

 


background image

6

1. Installation instructions

 

for the qualitified installer

Technical Data

BS

Type

35

    35 E

45

   45 E

60

   60 E

Design

Open outlet

Rate pressure

0 MPa / 0 bar

Water connection

G  ½“ (Extenal Thread)

Electrical connection

1/N/PE/AC 220...240 V.

Recomended circuit breaker

20 A.

25 A.

32 A.

Recomended cable size              (Sqmm)

2.5-4

4-6

Rated power (kW)        Rated current (A)

kW - A

kW - A

kW - A

                                                                 

220 V

     

3.5 - 15.9

       

4.5 - 20.5

     6.0 - 27.3

                                                                 

230 V

     

3.8 - 16.5

       

4.9 - 21.3

     6.6 - 28.7

                                                                 240 V

     4.2 - 17.5

 

       5.4 - 22.5

     7.1 - 29.6

 


background image

Fig 7

5

6

16

4

3

2

1

Unit structure

7

2.1 Technical description 

Fig. 7
 

1.  Thermostat

 

2.  Cable duct for electrical 

 

  connection

 

3.  Power light

 

4.  Rotary control for 

 

  temperature  adjustment

 

5.  Hot water connection for  

 

 

  shower hose

 

6.  Cold water connection

Fig. 2
 

7.  Lower fixing hole

 

8.  Position for electrical 

 

  connection, concealed

 

9.  Upper fixing hole

Fig. 3
  10.  Depth for mounting screw
  11.  Rear wall installation
Fig. 5
  12.  Combination filter/seal
  13.  Washer
  14.  Water valve
  15.  Union nut (provided by client)
Fig. 7
16    ELSD (option)

  

2. Operating instructions

 

for the qualitified installer

 


background image

8

2.2 Regulations and Provisions

 

 

Regulations of the local power 

 

 

supply company must be observed.

 

 

Regulations of the water supply 

 

 

company must be observed.

 

 

Install the unit flush with the wall.

 

 

Electrical connection to be secure.

 

 

The device must be capable of 

 

 

being isolated from the mains, 

 

 

for example by  fuses, with an 

 

 

isolating distance of at least 3.5 

 

 

mm, in all poles.

 

 

The unit must be earthed  

 

 

 

(see circuit diagram).  

2.3 Important note

 

 

All the information in these

 

 

Operating and Installation

Instructions must be carefully followed. 
These instructions provide important details 
regarding the safety, operation, installation, 
and maintenance of the unit.

2.4 Installation location

 

The shower unit is to be installed  

 

in a frost-free room (disconnected 

units are to be  stored in a frost-free loca-
tion, since there will always be some water 
left in the unit) The BS is to be installed 
vertically on a wall (hot water connection 
downwards) and higher than shower head 
level.

2.5 Installing the unit

 

1.  Flush the cold water pipe thoroughly.

 

2.   Fit a secure connection cable

 

  (ensure size is correct).

 

3.  Release cover securing screw.

 

4.  Remove cover.

 

5.  Determine  the position of the

 

  drillholes and drill the holes.  

 

  Insert the wall plugs and screw in 

 

  the screws (ensure screw insertion 

 

  depth is correct, 10). Fix the base to  

 

  the wall.

 

6.  Feed the connection cable through 

 

  the duct (2) in the rear wall. Tighten 

 

  the screws.

 

7.  Fit the water valve (14) with the 

 

  washer (13). Tighten the Union nut (15)

 

8.  Connect the electrical supply.

 

9.  Fit the cover and secure with the 

 

  screw.

  10.  Turn the rotary control (B) to the 
   

left  and right (internal  setting 

   

lever will  engage).

 

11. Fit the shower accessories to the unit.

2.6 First operation
 

(Only to be carried out by a 

 

qualified installer)

 
 

 

Before switching on, set the  

 

 

water  valve  to  the  right-hand 

stop (maximum setting) and let water run 
until the pipework  and the unit are free of 
air.
- Before switching on, set the rotary
  temperature control to “OFF”
- Check the operation of the water heater

2. Operating instructions

 

for the user and the qualitified installer

 


background image

9

Handing over the unit

Explain to the user how the unit works and 
familiarise him or her with its use.
-  Advise the user about possible hazards  
  (high water temperature)
-   Hand over these  instructions, to be kept  
  in a safe place. 

2.7 Service note

 

When carrying out any work,

 

isolate the unit from the mains and 

shut off the water connection.

2. Operating instructions

 

for the user and the qualitified installer

 


background image

10

3. Guarantee

4. Trouble-shooting

For guarantees please refer to the respec-
tive  terms  and    conditions  of  supply  for 
your country.

 

  The installation, electrical

 

  connection and first operation of 

this appliance should be carried out by a 
qualified installer.

The company does not accept liability  
for failure of any good supplied which 
have not been installed and operated 
in accordance with the manufacturer’s 
instructions.

Fault

Cause

Solution

No hot water despite

flow volume setting at

right-hand stop.

The water flow volume required 

for the unit to turn on has

not been reached.

- The shower head is   

   blocked with dirt or 

   limescale.

- Flow volume too low

- Clean shower head

- Increase flow volume.

The unit is not working. 

Electricity supply and

flow available.

The water flow volume 

required for the unit to turn 

on has not been reached.

- Filter in the cold water  

  connection pipe blocked 

  with dirt.

- Water pressure not    

  enough

- Clean the filter after shut-

  ting off the cold  water 

  intake

- Increase mains pressure

“ELSD” Light on

- The safety device 

  activated.

- Press “Reset” button

 


background image

11

 


background image

SIZE:A5

MATERIAL: GREEN READ PAPER 75 G.

PLASTIC BAG : 7 x 11 INCH

PART NO. 7901-269459 

PART NAME : MANUAL BS 

Rev.04

Product code : BS 35 E : 221070 / BS 45 E : 221071 / BS 60 E : 221072