 4s2

 

Variable Temperature Thermal Sealer Service Manual 

 

 
Version: B 

 

 

 

 

 

 

 

 

23 September 2010

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 1 

 

 

 

4s2 VARIABLE TEMPERATURE THERMAL SEALER 

SERVICE MANUAL 

 
 

This manual is intended to be used as a guide to maintaining the HT121TS thermal sealer. It is valid for 

the units with S/N higher than 42256. 

The information contained in this document is subject to change without notice. 

This document is for information only, manufacturer accepts no liability for errors contained herein or for 

incidental or consequential damages with the furnishing, performance, or use of this material. 

 

If not otherwise specified, each reference to names or belongings is purely casual and has the purpose 

to illustrate the product here described. Contents of this publication may not be reproduced in any form 

or  by  any  means  (including  electronic  storage  and  retrieval  or  translation  into  a  foreign  language) 

without prior agreement and written consent from the copyright owner. 

 

All rights are reserved. 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 2 

 

 

PAGE INDEX 

 
 

 

Page # 

TROUBLE SHOOTING GUIDE 

 

1.1  Trouble Shooting Guide 

 

1.2  Terminology and Abbreviation 

INTRODUCTION 

 

2.1  Warnings 

 

2.2  General Trouble Shooting Tips 

OPERATION 

 

3.1  High Handler Sensor Adjustment 

 

3.2  Low Handler Sensor Adjustment 

 

3.3  Drawer Sensor Adjustment 

 

3.4  Front-to-Back Adjustment 

 

3.5  Left-to-Right Adjustment 

12 

 

SPARE PARTS & ACCESSORIES  

13 

 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 3 

 

1  TROUBLE SHOOTING GUIDE 

 

1.1  Trouble Shooting Guide 

 

Below are the possible faults encountered, and their most probable solutions.  Some of 
these are hypothetical faults, as they have not been encountered. 

 

Fault 

Cause 

Solution 

Difficulty 

Comments 

No power 

Blown fuse 

Replace fuse 

See User Manual 

Unit switched on 

but motors do not 

move 

Incorrect voltage set 

Change voltage from 

220V to 110V 

See User Manual 

Unit continues to 

heat and gives 

temperature error, 

“ER6” 

Old firmware version 

installed 

Update firmware to 

latest version 

*** 

See IG-007: 

Instructions for 

upgrading 

software 

Unit switched on 

but gives 

temperature error, 

“ER6” 

Unit is too cold 

Allow unit to reach 

ambient temperature 

and retry 

 

Motor can’t reach 

“home” position. 

“ER1” or “ER4” 

appear or 

countdown starts 

without 

compressing the 

plate 

High handler sensor 

remains active in 

“home” position 

Readjust the High 

Handler Sensor bar 

***** 

See 3.1 

Unit gives 

overcurrent error 

after compression 

“ER5” 

High handler sensor 

isn’t active when the 

unit is compressing 

Readjust the High 

Handler Sensor bar 

***** 

See 3.1 

Unit gives low 

handler sensor 

error, “ER8” 

Low handler sensor 

i

sn’t active when the 

motor starts running 

Readjust the Low 

Handler Sensor bar 

**** 

See 3.2 

 
 

1.2  Terminology and Abbreviation 

 

Difficulty Rating: 

Easy (can be performed by end-user) 

** 

Moderate (experienced user) 

*** 

Average (trained technician required) 

**** 

Difficult 

***** 

Very difficult (operate unit under voltage) 

 

 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 4 

 

2  INTRODUCTION 

2.1  Warnings 

 

  This manual is intended for trained technicians only 

 
 

  All the procedures, if not differently specified, must be performed with the unit 

disconnected from the mains voltage (main power). 

  If the procedures request to operate with the power  on, do NOT touch the PCB or any 

internal parts that might have a voltage. 

  Handle the unit with care. 

  If it is necessary to use tools not provided with the 4s2 or to work on faults or parts of the 

unit not included within this Service Manual, please contact your supplier. 

 

2.2  General Trouble Shooting Tips 

 

If a fault occurs and you are unsure about the problem please contact your supplier giving 
the serial number of the unit and as much information about the fault as possible. 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 5 

 

3  OPERATION 

3.1  High Handler Sensor Adjustment 

 

1.  Remove the cover 

2.  Check the high handler bar sensor can move freely.  If not, unscrew the M4 screw that fixes 

the bar slightly (see “1”, Figure 1). 

3.  Check  the  bar  is  aligned  to  the  sensor  OPT3,  on  the  top  of  the  electronic  board.    If  not, 

gently bend the bar to realign it. 

4.  Switch on the unit, push down the bar and check the LED LD3, on the top of the electronic 

board remains off.  If not, gently bend the bar upwards slig

htly (see “2”, Figure 1). 

5.  During a compression cycle (at ambient temperature) check with a calliper the distance from 

the  heater  carter  and  the  top  plate  that  supports  the  heater  and bar  is 15 +/-  0.5  mm  (see 
Figure 2).  If not, alter the distance using t

he M3 screw and lock it with the M3 nut (see “3”, 

Figure 1) 

 

Figure 1 - Sensor Bar Adjustment 

 
 

 

Figure 2 - Compression Check 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 6 

 

3.2 Low Handler Sensor Adjustment 

 

1.  Remove the cover. 

2.  Check the high handler bar sensor can move freely.  If not, unscrew the M4 screw that fixes 

the bar slightly (see “1”, Figure 3). 

3.  Check the bar is aligned to the sensor OPT1, on the bottom of the electronic board.  If not, 

gently bend the bar to realign it. 

4.  Check the bar hook doesn't touch the drawer, and that the distance from the hook and 

the bottom bar of the drawer is less than 1mm (see “2”, Figure 3).  If not, alter the 
distance using the M3 screw and lock it with the M3 nut (see “3”, Figure 3). 

 

Figure 3 - Lower Handler Adjustment

 

5.  Disconnect the motor cable from the electronic board (2 poles connector J3) 

6.  Close the drawer completely and manually lift up the platen (rotate the motor manually) 

until the hook completely blocks the drawer. Check the drawer can move by 
approximately 1 mm by pushing it (see Figure 4).  If not, unscrew the two screws that fix 
the L-bar to the drawer, and re-position it. Re-tighten the two screws (see Figure 5). If 
necessary, gently bend the L-bar. 

 

Figure 4 - Drawer Locked

 

7.  Reconnect the motor cable. 

 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 7 

 

 

Figure 5 

– L-Bar Positioning

 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 8 

 

3.3 Drawer Sensor Adjustment 

 

1.  Remove the cover. 

2.  Disconnect the motor cable from the electronic board (2 poles connector J3). 

3.  Close the drawer completely and manually lift up the platen (rotate the motor manually) 

until the hook blocks completely the drawer. 

4.  Switch on the unit, pull the drawer and verify that the LED LD2 (on the bottom of the 

electronic board) remains off (regardless of unit errors).  If not, switch off the unit, 
unscrew the screw on the drawer sensor bar and re-position it (see Figure 6). Re-tighten 
the screw. 

 

 

Figure 6 - Drawer Sensor Adjustment 

5.  Switch off the unit. 

6.  Reconnect the motor cable. 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 9 

 

3.4  Front-to-Back Adjustment 

 

3.4.1 Units up to Serial Number 42330 

 

1.  Remove the cover. 

2. 

Locate the M4 screw underneath platen that receives the PCR / microplate (see Figure 
7).  If the front of the PCR / microplate is under-sealed, tighten the screw.  If the back 
of the PCR / microplate is under-sealed, loosen the screw.

 

 

 

Figure 7 - Front-to-Back Screw Adjustment 

 

3.  It may also be necessary to adjust the drawer: 

3.1.  Disconnect the motor cable. 

3.2.  Close  the  drawer  completely  and  manually  lift  up  the  platen  (rotate  the  motor 

manually).       

3.3.  Check the pins on the lift are aligned to the adaptor plate hole (see Figure 8).  If not, 

adjust the drawer front panel by unscrewing the four M3 screws (see Figure 9), then 
execute 

“Drawer Sensor Adjustment” (see page 8). 

 

Figure 8 - Adapter Aligned 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 10 

 

 

Figure 9 - Front Panel Adjustment 

 

3.4.  Reconnect the motor cable. 

 

 

3.4.2          Units from Serial number 42343 

1.  Remove the cover 

2.  Unscrew the 4 screws that fix the lift (Figure 10). 

 

Figure 10 - Lift Screws 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 11 

 

3.  Move the lift towards front or back to centralize to the heating block (Figure 11) 

 

Figure 11 - Adjusting the lift's position 

4.  Screw the 4 screw that fix the lift. 

5.  Execute the operations described in point 3 of the previous paragraph (3.4.1). 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 12 

 

3.5  Left-to-Right Adjustment 

 

1.  Remove the cover. 

2.  Locate  the  lower  M4  screw  underneath  the  platen  that  receives  the  PCR  /  microplate  (see 

Figure 10).  If the unit is under-sealing on the right, loosen the screw and tilt the lift to the left.  
If the unit is under-sealing on the left, loosen the screw and tilt the lift to the right. 

3.  Re-tighten the screw. 

 

 

Figure 12 - Left-to-Right Adjustment 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

4s2 Variable Temperature Thermal Sealer Service Manual 

 

 

 

4titude Ltd, The North Barn, Surrey Hills Business Park, Damphurst Lane, Wotton, Dorking, Surrey, RH5 6QT, UK 
Tel: +44 (0) 1306 884885  Fax: +44 (0) 1306 884886  info@4ti.co.uk  www.4ti.co.uk

  

Page 13 

 

 

4. Spare Parts & Accessories 
 

Description 

Code 

 

Warranty Extension 2

nd

 year (12 months) 

(must be bought within 3 months of purchase)

 

4ti-0626

 

 

Warranty Extension 2

nd

&3

rd

 year (24 months) 

(most be bought within 3 months of purchase)

 

4ti-0627 

 

Adapter for Deep Well Plates  

4ti-0615 

 

Adapter for 96 Well PCR Plates 

(Incudes 4ti-0612 sealing frame FOC)

 

4ti-0625 

 

Weighted Platen 

(anti roll-up tool)

 

4ti-0602 

 

Sealing Frame 

(Only compatible with 4ti-0625)

 

4ti-0612 

 

Replacement cardboard packaging & foam inserts 

SP-0650/PAC 

 

Rubber Feet, pack of 4 

SP-0650/RUF 

 

Front Panel, light grey  

(includes keypad and circuit board for key pad)

 

SP-0650/FPG 

 

Outer metal casing, light grey  

SP-0650/OCG  

 

Screw Kit for outer metal casing 

SP-0650/SCK  

 

Power socket assembly with fuse housing 

SP-0650/POW 

 

Fuse Kit 110V, pack of 10 fuses 

SP-0650/FK1 

 

Fuse Kit 230V, pack of 10 fuses 

SP-0650/FK2 

 

Main circuit board 

SP-0650/MCB 

 

Circuit Board for key pad 

SP-0650/CBK 

 

Transformer assembly 

SP-0650/TRA 

 

Heating element assembly 

SP-0650/HEA 

 

Firmware upgrade cable 

SP-0650/FUK