PDF User Manual

  1. Home
  2. Manuals
  3. 3xLogic V Series Quick Start Manual

3xLogic V Series Quick Start Manual

VX-2A-B-RIWD\ VX-2A-B-IWD\ VX-2A-B-IWD (R)

Made by: 3xLogic
Type: Quick Start Guide
Category: Security Camera
Pages: 13
Size: 1.28 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

1
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

VISIX V-Series All-in-One Cameras  

VX-2A-B-IWD / VX-2A-B-RIWD Quick Start Guide 

v01-2016 

 
 
 

 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

2
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

Table of Contents 

1 Part Names and Positions .............................................................................................................................. 3 

2 Installation .................................................................................................................................................... 4 

3 Adjusting Angle of the Camera ...................................................................................................................... 5 

4 Adjusting Zoom and Focus ............................................................................................................................. 5 

5 Accessing Camera Settings and Video............................................................................................................ 6 

5.1  M

ANUALLY 

L

OCATE 

C

AMERA 

IP

 

A

DDRESS 

(MAC

 

A

DDRESS 

HEX

 

C

ONVERSION

) ............................................................ 6 

5.2  A

UTOMATICALLY 

D

ETECT 

C

AMERA 

IP

 

A

DDRESS WITH 

3

X

LOGIC

 

C

AMERA 

S

ETUP 

U

TILITY

 ................................................ 6 

6 View Video on Camera Web Interface ........................................................................................................... 8 

6.1  I

NSTALLATION OF 

A

CTIVE

X

 

C

ONTROL

 .................................................................................................................... 8 

7

 Reboot .......................................................................................................................................................... 8 

8

 Factory Default .............................................................................................................................................. 9 

9

 Configure the Camera’s VIGIL Connect Alias .................................................................................................. 9 

10

 Adding a V-Series All-in-One Camera to VIGIL Client ................................................................................. 10 

11

 Hexadecimal-Decimal Conversion Table .................................................................................................... 12 

 

 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

3
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

1

 

Part Names and Positions   

Please check names and positions of each part with the following image.  

 

 

CAUTION: 

Make sure the polarity is correct. Incorrect connection may cause malfunction or damage the IP device. 

Power Adaptor Connector (DC 12V) 

 

* Model design and appearance are subject to change without any prior notice. 

 

LAN / POE 
connector 

Power Adaptor connector 

GREEN : DI 
WHITE : DI 
COM 
ORNAGE : DO 

Terminal connector 

Video Out 

SD Card 

Reset 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

4
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

1.1

 

Installation 

There is only one type of mounting explained in this manual. Refer to the device’s installation guide for more 
various mounting types. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
CAUTION: 

Sealing gaps is recommended as gaps may appear after the camera installation. Gaps may cause problems such 
as  moisture,  water  leakage  and  etc.,  which  negatively  affects  the  operation  of  the  camera  if  gaps  remain 
unsealed. 
 

CAUTION: 

To prevent products from damage, place the camera on stable and non-vibrating surfaces If the stability is in 
doubt, consult safety personnel for reinforcements, and then proceed with the installation. 

 
 
 
 

Steps: 

1).

 

Place the installation template (paper) 
included in the package on the desired 
installation surface. 

2).

 

Drill three holes in correct positions based on 
the template paper, and insert the anchor 
blocks into the holes.  

3).

 

Attach the silicon waterproof band included in 
the package to the camera’s mounting surface 
by aligning it with the three alignment holes.

 

4).

 

Connect the required cables including a power 
cable and a LAN cable (or PoE cable) to the 
device. Refer to 

Section 1: 

Part Names and 

Positions

 

for more details. 

5).

 

Place the camera body to match the three 
alignment holes with the three anchor blocks, 
and hold the camera against the surface where 
the camera will be mounted. 

6).

 

Tighten the anchor blocks with the screws 
(M4x30). 

7).

 

Adjust the heading direction of the camera 
with the provided hex wrench (3mm). Please 
refer to 

Section 2: 

Adjusting Angle of the 

Camera

 for more details.

 

8).

 

Adjust zoom and focus of the camera. Refer to 

Section 3: 

Adjusting Zoom and Focus

 for more 

details. 

9).

 

Attach the lens cover on the main body by 
rotating it clockwise. 

 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

5
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

2

 

Adjusting Angle of the Camera 

Steps: 

1).

 

Adjust the camera to the desired angle by unscrewing the joints referring to the following pictures.  

 
 
 
 
 

 

 
 
 
 
 

2).

 

Connect to the web page of the device to see its real-time image in order to check whether its angle is 
correctly adjusted. Refer to 

Section 5: 

View Video on Camera Web Interface

 

for details about using its 

web page. 

3

 

Adjusting Zoom and Focus 

Steps: 

1).

 

Unscrew the zoom puller and the focus puller counter-clockwise. 

2).

 

Adjust the zoom and the focus of the lens. 

3).

 

Tighten the zoom puller and the focus puller again by turning it 
clockwise after the zoom and the focus are properly adjusted. 

 

 
 
 

CAUTION: 

Manual adjustment of Zoom and Focus is only possible on the 

VX-2A-B-IWD

 model version. Zoom and Focus 

controls can be configured digitally from the camera’s web interface for

 VX-2A-B-RIWD models. 

See the VISIX 

V-Series All-in-One Camera User Manual for more details on adjusting lens settings from the camera’s web 
interface. 

 
 
 
 
 
 
 
 
 
 
 

Zoom Puller

 

Focus Puller 

Adjust the joint to install 

the camera on the wall.

 

Tilting adjustment

 

Panning adjustment

 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

6
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

4

 

Accessing Camera Settings and Video 

To begin viewing video or configuring a camera’s network settings from the camera’s web interface, the user 
must first identify the device’s IP address. The default IP address of the camera is 

192.168.XXX.XXX.

 The 

default subnet mask is 

255.255.0.0 

On simple, private networks, a user can manually identify the IP address of the camera by converting the camera’s 
MAC  address  hex  values,  however,  the  alternative  method,  which  is  recommended  by  3xLOGIC,  is  to  use  the 
3xLOGIC  (VSX-IP)  Camera  Setup  Utility.  The  utility  makes  detection  and  configuration  of  VISIX  camera’s  in  any 
network environment simple and easy, regardless of network complexity. 

Both methods require that the camera and the PC being used to communicate with it reside on the same network. 

4.1

 

Manually Locate Camera IP Address (MAC Address HEX Conversion) 

Users can access the camera’s web interface and settings using a device’s default IP address: In case of generic 
private network environment where IP address 192.168.XXX.XXX are used, the following procedure can be used to 
identify a device’s IP address.  

 

Steps: 

1).

 

Convert the device’s MAC address to the IP address. Refer to 

Section 10:

 

Hexadecimal-Decimal 

Conversion Table

 at the end of the manual (the MAC address of the device is written on the label 

affixed to the side or bottom of the device). 

 

 

 

 

2).

 

Start the Microsoft® Internet Explorer/Edge web browser and enter the address of the device.  

3).

 

Web streaming and device configurations are supported through ActiveX program. When the ActiveX 
installation window appears, authorize and install the ActiveX.

 

4.2

 

Automatically Detect Camera IP Address with 3xLOGIC Camera Setup Utility 

Using the 3xLOGIC Camera (VSX-IP) Setup Utility is recommended for any network environment as it will find all 
VISIX cameras across multiple subnet masks, utilizing mDNS search discovery. Camera information such as IP 
Address, Subnet Mask and Gateway Settings will be displayed and can be edited from this utility.  

Steps: 

1).

 

To search for a device, launch the utility 

VSXIPUtility.exe

. Click on 

Detect Online Devices/ Change IP 

Address

 to proceed to the Online Devices window.  

 

 
 
 
 
 
 
 
 
 

               MAC address = 00-13-23-01-14-B1 → IP address = 192.168.20.177 

Convert the last two sets of hexadecimal numbers to decimal numbers. 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

7
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

After clicking 

Detect Online Devices/ Change IP Address

 on the main page you will be taken to the Online 

Devices window. A list of all VISIX devices discovered on your network will be visible.  

2).

 

To select a device, click on the desired device in the generated menu under the

 

Select Online Devices

 

area.  

3).

 

To change an IP address for a selected VISIX camera in the 

Detect Online Devices Window,

 select the 

desired camera, click on the 

Change IP Address

 button. The fields under the 

Configure IP Address

 area 

will un-grey to allow for manual editing of camera IP addresses as well as other settings.  

 

 

 

4).

 

When you have finished editing the settings, click 

Save IP Address

 to save new changes.  

5).

 

Start the Microsoft® Edge/Internet Explorer web browser and enter the address of the device.  

6).

 

Web streaming and device configurations are supported through ActiveX program. When the ActiveX 
installation window appears, authorize and install the ActiveX. 

 

 
 
 
 
 
 
 
 
 
 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

8
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

5

 

View Video on Camera Web Interface  

Once the device’s proper IP address has been identified, type the IP into a web browser URL (Microsoft Internet 
Explorer/Edge required for ActiveX control) to view the camera’s web interface and video stream images. The 
default username and password is 

admin/12345. 

After initial access, an ActiveX control installation pop up may 

deploy. ActiveX is required for viewing video in the browser.   

5.1

 

Installation of ActiveX Control 

 

 

Steps: 

1).

 

When the browser asks to install the AxUMF software, click Install to proceed. 

 

 

 

2).

 

When the setup installation pop-up window appears, click 

Install

 to proceed with rest of installation. 

NOTE: 

Depending on system OS and Internet Explorer version, installation experience may differ from one another. 
Figures described above are from Windows 7, Internet Explorer 9 environment. 
Upon completion, the camera’s web interface will be fully accessible for video viewing and settings 
configuration.  

6

 

Reboot 

Perform the following procedures to reset your device: 

Steps: 

1).

 

Press the Reset button, and hold it for 2 seconds while the device is in use. 

2).

 

Wait for the system to reboot. 

CAUTION: 

Please do not hold the reset  button for more than 2 seconds. Otherwise, the camera may be switched to its 
Factory Default settings. 

-Or- 

3).

 

Open the 3xLOGIC Camera Setup Utility. 

4).

 

Select your device.  

5).

 

Open Advanced Settings. 

6).

 

Click 

Reboot.

 

 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

9
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

7

 

Factory Default 

Resetting the device back to the factory default will reinitialize all parameters including the IP address back to 
the factory defaults. To reset back to the factory default: 
 

Steps: 

1).

 

Press the reset button and hold it while the device is in use. 

2).

 

Release the button after about 10 seconds. 

3).

 

Wait for the system to reboot. 

NOTE: 

Factory Default Connection Settings

 

IP Address 

192.168.XX.YY 

Network Mask 

255.255.0.0 

Gateway 

192.168.0.1 

User ID 

admin 

Password 

12345 

 

8

 

Configure the Camera’s VIGIL Connect Alias 

VIGIL Connect allows VIGIL VMS users to remotely connect to a VIGIL Server/V-Series All-in-One camera using 
the system serial number or a user defined VIGIL Connect 

alias

, without the need for extensive changes to an 

existing network’s settings. This allows for the device to be networked with other VIGIL suite utilities with little 
effort and minimal knowledge of the device’s network connection values.  

 

Steps: 

1).

 

To configure a VIGIL Connect alias, navigate to the camera’s 

Basic Tab>Camera Configuration Menu>Site 

Information Settings

 page. 

 

 

Figure 4-6:

 Configuring a VIGIL Connect Alias 

 

2).

 

Fill in the 

VIGIL Connect Alias

 field with an alias of your choosing. 

3).

 

Click 

Apply

 

to save the new alias. 

 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

1
0
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

10 

Your VISIX V-Series All-in-One camera can now be networked with other 3xLOGIC utilities and VIGIL suite 
applications (VIGIL Client, VIGIL VCM, View Lite II(Android and iOS), 3xCLOUD, etc…) using only the camera’s 
VIGIL Connect Alias. 
 

9

 

 Adding a V-Series All-in-One Camera to VIGIL Client 

Steps: 

1).

 

To interface a VISIX All-in-One Camera with VIGIL Client, launch VIGIL Client (Local Mode only; VCM 
mode will only display Servers from a networked VCM Server) and select 

Servers

 from the Servers top 

menu. This will launch the Servers window. VISIX All-in-One devices are considered edge recording 
devices, and thus are recognized as their own VIGIL Server within the VIGIL suite. 

2).

 

Click 

Add

. This will deploy the 

Add/Edit VIGIL Server

 window. 

3).

 

Enable the 

Use VIGIL Connect

 

option. If connecting using traditional network connection criteria is 

desired, enter the cameras 

IP Address/DNS Name

 

and confirm TCP/IP port status.  

4).

 

Enter in the VIGIL Connect alias of the desired VISIX All-in-One camera (

VIGILTest1

 used in the below 

example). Skip this step if using traditional network connection criteria (IP/Port). 

5).

 

Click 

Test VIGIL Connect

 

to confirm the camera can be communicated with through the Connect 

system using the provided alias. Skip this step if using traditional network connection criteria (IP/Port). 

 

 

Figure 4-5:

 Adding All-in-One Camera to VIGIL Client 

 

6).

 

If the test is successful, then VIGIL Client can successfully communicate with the Server. Click 

OK

 

at the 

bottom of the 

Add Server

 window after configuring all required fields to save the new Server to VIGIL 

Client. For more information on configuring VIGIL Servers, please see 

Section 5.1

 of the 

VIGIL Client 

8.0 User Guide

 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

1
1
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

11 

The camera will be visible in the Client treeview and will be represented by a  

 icon. The camera video 

stream can be added to the VIGIL Client viewer in the same manner as VIGIL Server cameras; Simply extend the 
camera’s drop-down menu and double click the icon to add it to the viewer. Alternatively, a user can drag-and-
drop the camera stream icon into the desired frame of the VIGIL Client viewer. 

For more information on configuring VIGIL Servers/V-Series All-in-One camera in VIGIL Client, please see 

Section 5.1

 of the 

VIGIL Client 8.0 User Guide.

 

 


background image

VISIX Camera Quick Start Guide |

 

VX-2A-B-IWD (R) 

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

1
2
 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

12 

10

 

Hexadecimal-Decimal Conversion Table 

Refer to the following table when you convert the MAC address of your device to IP address. 

 

Hex  Dec 

 

Hex  Dec 

 

Hex  Dec 

 

Hex  Dec 

 

Hex  Dec 

 

Hex  Dec 

 

Hex  Dec 

 

25 

37 

 

4A 

74 

 

6F 

111   

94 

148   

B9 

185   

DE 

222 

 

26 

38 

 

4B 

75 

 

70 

112   

95 

149   

BA 

186   

DF 

223 

 

27 

39 

 

4C 

76 

 

71 

113   

96 

150   

BB 

187   

E0 

224 

 

28 

40 

 

4D 

77 

 

72 

114   

97 

151   

BC 

188   

E1 

225 

 

29 

41 

 

4E 

78 

 

73 

115   

98 

152   

BD 

189   

E2 

226 

 

2A 

42 

 

4F 

79 

 

74 

116   

99 

153   

BE 

190   

E3 

227 

 

2B 

43 

 

50 

80 

 

75 

117   

9A 

154   

BF 

191   

E4 

228 

 

2C 

44 

 

51 

81 

 

76 

118   

9B 

155   

C0 

192   

E5 

229 

 

2D 

45 

 

52 

82 

 

77 

119   

9C 

156   

C1 

193   

E6 

230 

 

2E 

46 

 

53 

83 

 

78 

120   

9D 

157   

C2 

194   

E7 

231 

0A 

10 

 

2F 

47 

 

54 

84 

 

79 

121   

9E 

158   

C3 

195   

E8 

232 

0B 

11 

 

30 

48 

 

55 

85 

 

7A 

122   

9F 

159   

C4 

196   

E9 

233 

0C 

12 

 

31 

49 

 

56 

86 

 

7B 

123   

A0 

160   

C5 

197   

EA 

234 

0D 

13 

 

32 

50 

 

57 

87 

 

7C 

124   

A1 

161   

C6 

198   

EB 

235 

0E 

14 

 

33 

51 

 

58 

88 

 

7D 

125   

A2 

162   

C7 

199   

EC 

236 

0F 

15 

 

34 

52 

 

59 

89 

 

7E 

126   

A3 

163   

C8 

200   

ED 

237 

10 

16 

 

35 

53 

 

5A 

90 

 

7F 

127   

A4 

164   

C9 

201   

EE 

238 

11 

17 

 

36 

54 

 

5B 

91 

 

80 

128   

A5 

165   

CA 

202   

EF 

239 

12 

18 

 

37 

55 

 

5C 

92 

 

81 

129   

A6 

166   

CB 

203   

F0 

240 

13 

19 

 

38 

56 

 

5D 

93 

 

82 

130   

A7 

167   

CC 

204   

F1 

241 

14 

20 

 

39 

57 

 

5E 

94 

 

83 

131   

A8 

168   

CD 

205   

F2 

242 

15 

21 

 

3A 

58 

 

5F 

95 

 

84 

132   

A9 

169   

CE 

206   

F3 

243 

16 

22 

 

3B 

59 

 

60 

96 

 

85 

133   

AA 

170   

CF 

207   

F4 

244 

17 

23 

 

3C 

60 

 

61 

97 

 

86 

134   

AB 

171   

D0 

208   

F5 

245 

18 

24 

 

3D 

61 

 

62 

98 

 

87 

135   

AC 

172   

D1 

209   

F6 

246 

19 

25 

 

3E 

62 

 

63 

99 

 

88 

136   

AD 

173   

D2 

210   

F7 

247 

1A 

26 

 

3F 

63 

 

64 

100   

89 

137   

AE 

174   

D3 

211   

F8 

248 

1B 

27 

 

40 

64 

 

65 

101   

8A 

138   

AF 

175   

D4 

212   

F9 

249 

1C 

28 

 

41 

65 

 

66 

102   

8B 

139   

B0 

176   

D5 

213   

FA 

250 

1D 

29 

 

42 

66 

 

67 

103   

8C 

140   

B1 

177   

D6 

214   

FB 

251 

1E 

30 

 

43 

67 

 

68 

104   

8D 

141   

B2 

178   

D7 

215   

FC 

252 

1F 

31 

 

44 

68 

 

69 

105   

8E 

142   

B3 

179   

D8 

216   

FD 

253 

20 

32 

 

45 

69 

 

6A 

106   

8F 

143   

B4 

180   

D9 

217   

FE 

254 

21 

33 

 

46 

70 

 

6B 

107   

90 

144   

B5 

181   

DA 

218   

FF 

255 

22 

34 

 

47 

71 

 

6C 

108   

91 

145   

B6 

182   

DB 

219   

 

 

23 

35 

 

48 

72 

 

6D 

109   

92 

146   

B7 

183   

DC 

220   

 

 

24 

36 

 

49 

73 

 

6E 

110   

93 

147   

B8 

184   

DD 

221   

 

 

 


background image

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

1
3
 

 

10225 Westmoor Drive, Suite 300 

Westminster, CO 80021 

303.430.1969 

Toll Free: 877.3xLOGIC 

www.3xlogic.com 

 

 
© 2016 3xLOGIC Inc. All rights reserved.  
Information in this document is subject to change without notice. 3xLOGIC and the 
3xLOGIC logo are trademarks of 3xLOGIC, Inc. all other trademarks are property of 
their respective owners.  
Revised: January 22

nd

, 2016