Full Text Searchable PDF User Manual

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
1
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
1
VISIX V-Series All-in-One Cameras
VX-2A-B-IWD / VX-2A-B-RIWD Quick Start Guide
v01-2016

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
2
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
2
Table of Contents
1 Part Names and Positions .............................................................................................................................. 3
2 Installation .................................................................................................................................................... 4
3 Adjusting Angle of the Camera ...................................................................................................................... 5
4 Adjusting Zoom and Focus ............................................................................................................................. 5
5 Accessing Camera Settings and Video............................................................................................................ 6
5.1 M
ANUALLY
L
OCATE
C
AMERA
IP
A
DDRESS
(MAC
A
DDRESS
HEX
C
ONVERSION
) ............................................................ 6
5.2 A
UTOMATICALLY
D
ETECT
C
AMERA
IP
A
DDRESS WITH
3
X
LOGIC
C
AMERA
S
ETUP
U
TILITY
................................................ 6
6 View Video on Camera Web Interface ........................................................................................................... 8
6.1 I
NSTALLATION OF
A
CTIVE
X
C
ONTROL
.................................................................................................................... 8
7
Reboot .......................................................................................................................................................... 8
8
Factory Default .............................................................................................................................................. 9
9
Configure the Camera’s VIGIL Connect Alias .................................................................................................. 9
10
Adding a V-Series All-in-One Camera to VIGIL Client ................................................................................. 10
11
Hexadecimal-Decimal Conversion Table .................................................................................................... 12

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
3
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
3
1
Part Names and Positions
Please check names and positions of each part with the following image.
CAUTION:
Make sure the polarity is correct. Incorrect connection may cause malfunction or damage the IP device.
Power Adaptor Connector (DC 12V)
* Model design and appearance are subject to change without any prior notice.
LAN / POE
connector
Power Adaptor connector
GREEN : DI
WHITE : DI
COM
ORNAGE : DO
Terminal connector
Video Out
SD Card
Reset

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
4
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
4
1.1
Installation
There is only one type of mounting explained in this manual. Refer to the device’s installation guide for more
various mounting types.
CAUTION:
Sealing gaps is recommended as gaps may appear after the camera installation. Gaps may cause problems such
as moisture, water leakage and etc., which negatively affects the operation of the camera if gaps remain
unsealed.
CAUTION:
To prevent products from damage, place the camera on stable and non-vibrating surfaces If the stability is in
doubt, consult safety personnel for reinforcements, and then proceed with the installation.
Steps:
1).
Place the installation template (paper)
included in the package on the desired
installation surface.
2).
Drill three holes in correct positions based on
the template paper, and insert the anchor
blocks into the holes.
3).
Attach the silicon waterproof band included in
the package to the camera’s mounting surface
by aligning it with the three alignment holes.
4).
Connect the required cables including a power
cable and a LAN cable (or PoE cable) to the
device. Refer to
Section 1:
Part Names and
Positions
for more details.
5).
Place the camera body to match the three
alignment holes with the three anchor blocks,
and hold the camera against the surface where
the camera will be mounted.
6).
Tighten the anchor blocks with the screws
(M4x30).
7).
Adjust the heading direction of the camera
with the provided hex wrench (3mm). Please
refer to
Section 2:
Adjusting Angle of the
Camera
for more details.
8).
Adjust zoom and focus of the camera. Refer to
Section 3:
Adjusting Zoom and Focus
for more
details.
9).
Attach the lens cover on the main body by
rotating it clockwise.

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
5
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
5
2
Adjusting Angle of the Camera
Steps:
1).
Adjust the camera to the desired angle by unscrewing the joints referring to the following pictures.
2).
Connect to the web page of the device to see its real-time image in order to check whether its angle is
correctly adjusted. Refer to
Section 5:
View Video on Camera Web Interface
for details about using its
web page.
3
Adjusting Zoom and Focus
Steps:
1).
Unscrew the zoom puller and the focus puller counter-clockwise.
2).
Adjust the zoom and the focus of the lens.
3).
Tighten the zoom puller and the focus puller again by turning it
clockwise after the zoom and the focus are properly adjusted.
CAUTION:
Manual adjustment of Zoom and Focus is only possible on the
VX-2A-B-IWD
model version. Zoom and Focus
controls can be configured digitally from the camera’s web interface for
VX-2A-B-RIWD models.
See the VISIX
V-Series All-in-One Camera User Manual for more details on adjusting lens settings from the camera’s web
interface.
Zoom Puller
Focus Puller
Adjust the joint to install
the camera on the wall.
Tilting adjustment
Panning adjustment

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
6
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
6
4
Accessing Camera Settings and Video
To begin viewing video or configuring a camera’s network settings from the camera’s web interface, the user
must first identify the device’s IP address. The default IP address of the camera is
192.168.XXX.XXX.
The
default subnet mask is
255.255.0.0
On simple, private networks, a user can manually identify the IP address of the camera by converting the camera’s
MAC address hex values, however, the alternative method, which is recommended by 3xLOGIC, is to use the
3xLOGIC (VSX-IP) Camera Setup Utility. The utility makes detection and configuration of VISIX camera’s in any
network environment simple and easy, regardless of network complexity.
Both methods require that the camera and the PC being used to communicate with it reside on the same network.
4.1
Manually Locate Camera IP Address (MAC Address HEX Conversion)
Users can access the camera’s web interface and settings using a device’s default IP address: In case of generic
private network environment where IP address 192.168.XXX.XXX are used, the following procedure can be used to
identify a device’s IP address.
Steps:
1).
Convert the device’s MAC address to the IP address. Refer to
Section 10:
Hexadecimal-Decimal
Conversion Table
at the end of the manual (the MAC address of the device is written on the label
affixed to the side or bottom of the device).
2).
Start the Microsoft® Internet Explorer/Edge web browser and enter the address of the device.
3).
Web streaming and device configurations are supported through ActiveX program. When the ActiveX
installation window appears, authorize and install the ActiveX.
4.2
Automatically Detect Camera IP Address with 3xLOGIC Camera Setup Utility
Using the 3xLOGIC Camera (VSX-IP) Setup Utility is recommended for any network environment as it will find all
VISIX cameras across multiple subnet masks, utilizing mDNS search discovery. Camera information such as IP
Address, Subnet Mask and Gateway Settings will be displayed and can be edited from this utility.
Steps:
1).
To search for a device, launch the utility
VSXIPUtility.exe
. Click on
Detect Online Devices/ Change IP
Address
to proceed to the Online Devices window.
MAC address = 00-13-23-01-14-B1 → IP address = 192.168.20.177
Convert the last two sets of hexadecimal numbers to decimal numbers.

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
7
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
7
After clicking
Detect Online Devices/ Change IP Address
on the main page you will be taken to the Online
Devices window. A list of all VISIX devices discovered on your network will be visible.
2).
To select a device, click on the desired device in the generated menu under the
Select Online Devices
area.
3).
To change an IP address for a selected VISIX camera in the
Detect Online Devices Window,
select the
desired camera, click on the
Change IP Address
button. The fields under the
Configure IP Address
area
will un-grey to allow for manual editing of camera IP addresses as well as other settings.
4).
When you have finished editing the settings, click
Save IP Address
to save new changes.
5).
Start the Microsoft® Edge/Internet Explorer web browser and enter the address of the device.
6).
Web streaming and device configurations are supported through ActiveX program. When the ActiveX
installation window appears, authorize and install the ActiveX.

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
8
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
8
5
View Video on Camera Web Interface
Once the device’s proper IP address has been identified, type the IP into a web browser URL (Microsoft Internet
Explorer/Edge required for ActiveX control) to view the camera’s web interface and video stream images. The
default username and password is
admin/12345.
After initial access, an ActiveX control installation pop up may
deploy. ActiveX is required for viewing video in the browser.
5.1
Installation of ActiveX Control
Steps:
1).
When the browser asks to install the AxUMF software, click Install to proceed.
2).
When the setup installation pop-up window appears, click
Install
to proceed with rest of installation.
NOTE:
Depending on system OS and Internet Explorer version, installation experience may differ from one another.
Figures described above are from Windows 7, Internet Explorer 9 environment.
Upon completion, the camera’s web interface will be fully accessible for video viewing and settings
configuration.
6
Reboot
Perform the following procedures to reset your device:
Steps:
1).
Press the Reset button, and hold it for 2 seconds while the device is in use.
2).
Wait for the system to reboot.
CAUTION:
Please do not hold the reset button for more than 2 seconds. Otherwise, the camera may be switched to its
Factory Default settings.
-Or-
3).
Open the 3xLOGIC Camera Setup Utility.
4).
Select your device.
5).
Open Advanced Settings.
6).
Click
Reboot.

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
9
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
9
7
Factory Default
Resetting the device back to the factory default will reinitialize all parameters including the IP address back to
the factory defaults. To reset back to the factory default:
Steps:
1).
Press the reset button and hold it while the device is in use.
2).
Release the button after about 10 seconds.
3).
Wait for the system to reboot.
NOTE:
Factory Default Connection Settings
IP Address
192.168.XX.YY
Network Mask
255.255.0.0
Gateway
192.168.0.1
User ID
admin
Password
12345
8
Configure the Camera’s VIGIL Connect Alias
VIGIL Connect allows VIGIL VMS users to remotely connect to a VIGIL Server/V-Series All-in-One camera using
the system serial number or a user defined VIGIL Connect
alias
, without the need for extensive changes to an
existing network’s settings. This allows for the device to be networked with other VIGIL suite utilities with little
effort and minimal knowledge of the device’s network connection values.
Steps:
1).
To configure a VIGIL Connect alias, navigate to the camera’s
Basic Tab>Camera Configuration Menu>Site
Information Settings
page.
Figure 4-6:
Configuring a VIGIL Connect Alias
2).
Fill in the
VIGIL Connect Alias
field with an alias of your choosing.
3).
Click
Apply
to save the new alias.

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
1
0
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
10
Your VISIX V-Series All-in-One camera can now be networked with other 3xLOGIC utilities and VIGIL suite
applications (VIGIL Client, VIGIL VCM, View Lite II(Android and iOS), 3xCLOUD, etc…) using only the camera’s
VIGIL Connect Alias.
9
Adding a V-Series All-in-One Camera to VIGIL Client
Steps:
1).
To interface a VISIX All-in-One Camera with VIGIL Client, launch VIGIL Client (Local Mode only; VCM
mode will only display Servers from a networked VCM Server) and select
Servers
from the Servers top
menu. This will launch the Servers window. VISIX All-in-One devices are considered edge recording
devices, and thus are recognized as their own VIGIL Server within the VIGIL suite.
2).
Click
Add
. This will deploy the
Add/Edit VIGIL Server
window.
3).
Enable the
Use VIGIL Connect
option. If connecting using traditional network connection criteria is
desired, enter the cameras
IP Address/DNS Name
and confirm TCP/IP port status.
4).
Enter in the VIGIL Connect alias of the desired VISIX All-in-One camera (
VIGILTest1
used in the below
example). Skip this step if using traditional network connection criteria (IP/Port).
5).
Click
Test VIGIL Connect
to confirm the camera can be communicated with through the Connect
system using the provided alias. Skip this step if using traditional network connection criteria (IP/Port).
Figure 4-5:
Adding All-in-One Camera to VIGIL Client
6).
If the test is successful, then VIGIL Client can successfully communicate with the Server. Click
OK
at the
bottom of the
Add Server
window after configuring all required fields to save the new Server to VIGIL
Client. For more information on configuring VIGIL Servers, please see
Section 5.1
of the
VIGIL Client
8.0 User Guide
.

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
1
1
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
11
The camera will be visible in the Client treeview and will be represented by a
icon. The camera video
stream can be added to the VIGIL Client viewer in the same manner as VIGIL Server cameras; Simply extend the
camera’s drop-down menu and double click the icon to add it to the viewer. Alternatively, a user can drag-and-
drop the camera stream icon into the desired frame of the VIGIL Client viewer.
For more information on configuring VIGIL Servers/V-Series All-in-One camera in VIGIL Client, please see
Section 5.1
of the
VIGIL Client 8.0 User Guide.

VISIX Camera Quick Start Guide |
VX-2A-B-IWD (R)
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
1
2
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
12
10
Hexadecimal-Decimal Conversion Table
Refer to the following table when you convert the MAC address of your device to IP address.
Hex Dec
Hex Dec
Hex Dec
Hex Dec
Hex Dec
Hex Dec
Hex Dec
0
0
25
37
4A
74
6F
111
94
148
B9
185
DE
222
1
1
26
38
4B
75
70
112
95
149
BA
186
DF
223
2
2
27
39
4C
76
71
113
96
150
BB
187
E0
224
3
3
28
40
4D
77
72
114
97
151
BC
188
E1
225
4
4
29
41
4E
78
73
115
98
152
BD
189
E2
226
5
5
2A
42
4F
79
74
116
99
153
BE
190
E3
227
6
6
2B
43
50
80
75
117
9A
154
BF
191
E4
228
7
7
2C
44
51
81
76
118
9B
155
C0
192
E5
229
8
8
2D
45
52
82
77
119
9C
156
C1
193
E6
230
9
9
2E
46
53
83
78
120
9D
157
C2
194
E7
231
0A
10
2F
47
54
84
79
121
9E
158
C3
195
E8
232
0B
11
30
48
55
85
7A
122
9F
159
C4
196
E9
233
0C
12
31
49
56
86
7B
123
A0
160
C5
197
EA
234
0D
13
32
50
57
87
7C
124
A1
161
C6
198
EB
235
0E
14
33
51
58
88
7D
125
A2
162
C7
199
EC
236
0F
15
34
52
59
89
7E
126
A3
163
C8
200
ED
237
10
16
35
53
5A
90
7F
127
A4
164
C9
201
EE
238
11
17
36
54
5B
91
80
128
A5
165
CA
202
EF
239
12
18
37
55
5C
92
81
129
A6
166
CB
203
F0
240
13
19
38
56
5D
93
82
130
A7
167
CC
204
F1
241
14
20
39
57
5E
94
83
131
A8
168
CD
205
F2
242
15
21
3A
58
5F
95
84
132
A9
169
CE
206
F3
243
16
22
3B
59
60
96
85
133
AA
170
CF
207
F4
244
17
23
3C
60
61
97
86
134
AB
171
D0
208
F5
245
18
24
3D
61
62
98
87
135
AC
172
D1
209
F6
246
19
25
3E
62
63
99
88
136
AD
173
D2
210
F7
247
1A
26
3F
63
64
100
89
137
AE
174
D3
211
F8
248
1B
27
40
64
65
101
8A
138
AF
175
D4
212
F9
249
1C
28
41
65
66
102
8B
139
B0
176
D5
213
FA
250
1D
29
42
66
67
103
8C
140
B1
177
D6
214
FB
251
1E
30
43
67
68
104
8D
141
B2
178
D7
215
FC
252
1F
31
44
68
69
105
8E
142
B3
179
D8
216
FD
253
20
32
45
69
6A
106
8F
143
B4
180
D9
217
FE
254
21
33
46
70
6B
107
90
144
B5
181
DA
218
FF
255
22
34
47
71
6C
108
91
145
B6
182
DB
219
23
35
48
72
6D
109
92
146
B7
183
DC
220
24
36
49
73
6E
110
93
147
B8
184
DD
221

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
1
3
10225 Westmoor Drive, Suite 300
Westminster, CO 80021
303.430.1969
Toll Free: 877.3xLOGIC
www.3xlogic.com
© 2016 3xLOGIC Inc. All rights reserved.
Information in this document is subject to change without notice. 3xLOGIC and the
3xLOGIC logo are trademarks of 3xLOGIC, Inc. all other trademarks are property of
their respective owners.
Revised: January 22
nd
, 2016