background image

Quick Start Guide Connecting GPS 
Queclink GV-75 / GV-200 / GV-300 

Contact technical support of 

Queclink: 

(from 10 am to 6 pm 
local time of Shanghai) 
+8 621 510 82 965
support@queclink.com

Contact Technical Support of 

Escort:

+7 495 108 68 33
support@fmeter.ru

Contact technical support of

 Wialon:

+3 703 799 94 60, +7 499 918 31 86
support@gurtam.com

 


background image

2

3

Lists settings in the table to copy 
(the right button mouse → copy) 

Lists settings in the table to copy (the 
right button mouse → copy)

Lists settings

Lists settings

We introduce the SIM, connect the antennas (depending on model).

We connect to the computer, feed the GPS 

module, write APN settings.

Server configured for Wialon

GV75    

GV200

GV300

193.193.165.165

193.193.165.165

193.193.165.165

21127

20420

20479

IP-адрес

Порт

GV-200

GV-300

GV-75

Attention!

 

some particular configurations

described in the final of this document.

ATTENTION!

 any GPS module can be 

configured easily and quickly, sending an SMS 
with AT command from the configurator

1

2

3

And the interface table entries:

GV75    

GV200

GV300

+

+

+

-

-

0.3 to 16 V

+

+

+

1 und.

2 und.

2 und.

RS-232

Analog input

discrete input 
(ignition)

discrete input 
(negative)

https://yadi.sk/d/_
XzQ7Mit3ZySDs

https://yadi.sk/d/
ifEcZiLv3ZySHG

https://yadi.sk/d/
A7V7d1PR3ZySNA

 


background image

4

5

Lists settings in the table to copy 
(the right button mouse → copy)

Lists settings in the table to copy 
(the right button mouse → copy)

Escort TD-600 in RS-232 mode

Escort TD-600 in RS-232 mode

Then configure the digital interface:

For delivery of data from the 

sensors, fuel level, the next 

box is activated mask 

ERI

We deactivate the 

SACK. SACK

 

determines whether the server 

should react to the GPS module 

with a 

SACK

 message, receiving 

a message from the GPS module.

Attention!!! 

For GPS GV-75 this paragraph configurations module applies only 

to complete all tuning operations as after activating the operating mode with 

the sensor, the only way to re-communicate with the GPS module to modify 

or follow the settings it is only through SMS 

«aT + GTFRI = gv75,1,0, 0,0000,0000, 30,1000,1000, 18,30,1 ,,,, $ FFFF ‘command

4

5

5

 


background image

6

7

The wiring diagram of the sensor 
Escort TD-600 in RS-232 mode

Lists settings in the table to copy 
(the right button mouse → copy)

Escort TD-600 in RS-232 mode

Escort TD-600 in RS-232 mode

Place the Escort TD-600 to RS-232 sensor mode and establish the network address 255

Connect the sensor to the GPS module. Ready. We wialon review the reports

7

8

Disconnect mode operation GPS 

module, without forming the 

questions by RS-232 to the sensor 

(deactivate the box).

6

(The GPS module pairs are connected: 

the transmitter of a device with the 

receiver of another well Rx_ TX and RX 

TX_):

 


background image

8

9

Connecting the sensor 
in analog mode (GV300):

Connecting the sensor 
in analog mode (GV300):

Connecting the sensor in analog mode (GV300)

Connecting the sensor in analog mode (GV300)

Model

GV-75

GV-200

GV-300

Description

After activating the operating mode with the sensor (paragraph 6 of this guide), the only way to return 
to communicate to modify or further configurations GPS module is only through the SMS command 
‘AT + GTFRI = gv75 , 1.0, 0,0000,0000, 30,1000,1000, 18,30,1 ,,,, $ FFFF «

Through a small bridge or band it is necessary to mimic the signal partner availability, or connect the 
input DTR (Data Terminal Ready) and output +5 V (contacts 13 and 19 of the GPS module, previously 
activating the box output settings).

It is also necessary to connect «earth» signal for the start of counting. Do common with the sensor (18 
GV_200 contact common to the TD-600 sensor and power supply).
The first interface 232 (1) is of service through the same terminal configuration is done, the second 
serves for operations with external equipment.

No particularities and difficulties