Full Text Searchable PDF User Manual

H A R D W A R E R A I D C O N T R O L L E R S
3 w a r e
®
P r o d u c t G u i d e
W i n t e r 2 0 0 8 / 2 0 0 9
AMCC reserves the right to make changes to its products, or to discontinue any product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the
information being relied upon is current. For the latest 3ware product information, visit www.3ware.com.
AMCC is a registered trademark of Applied Micro Circuits Corporation. 3ware, 3DM and StorSwitch are registered trademarks of Applied Micro Circuits Corporation in the United States. All other trademarks are the property of their
respective holders. Copyright © 2008 Applied Micro Circuits Corporation. All Rights Reserved.
FamPG_102108
215 Moffett Park Drive
Sunnyvale, CA 94089
Tel:
+1-408-542-8771
+1-877-883-9273
Email: 3waresales
@
amcc.com
www.3ware.com
Europe:
+44-1494-890700
Asia/Pacific: +65-6826-3381
China:
+86-10-6581-4916
Sales Offices for 3ware Products:

SAS
SATA
3ware RAID Controllers
The Right Tool for the Job
3ware pioneered the way for SATA and we now capitalize on our time-proven serial storage expertise to take users from SCSI to SAS. Most importantly,
whether our customers require SAS, SATA or combined SAS/SATA connectivity, 3ware will provide the right tool for the job.
Servers
Security/
Surveillance
Pro
Video
Super
Computing
NAS
Video
On-Demand
Pro
Audio
Disk-to-Disk
Backup
A P P L I C A T I O N S
F O R 3 W A R E C O N T R O L L E R S
1
Advanced RAID features, SAS and SATA II connectivity, and powerful 3ware performance architecture make 3ware controllers ideal for vertical applications
that require the highest levels of sustained write and read performance.
The interface for the direct-attach server space, SCSI’s former
mainstay. SAS is for mission critical applications that require
higher levels of availability and native expansion.
• Mission Critical Applications
• High Availability
• Native Expansion
• Optimized for Random
Performance
• Emerging Infrastructure
The cost- and performance-optimized interface for the majority
of value-end storage appliances that employ a fixed number of
drives to serve vertical applications, like video surveillance.
• Vertical Applications
• Cost Optimized
• Optimized for Sequential
Performance
• Mature Infrastructure
AMCC Headquarters in Sunnyvale, CA
T A b l e o f C o n T e n T s
3ware RAID Controllers
—
The Right Tool for the Job
1
3ware 9690SA
2
3ware 9650SE
3
3ware 9550SXU
3
3ware Sidecar
4
xSATA vs. eSATA, FireWire and USB
4
Multi-lane Cables and Connectors
5
3ware Controller/Cable Matrix
6
Battery Backup Units
8
3ware Features and Benefits
8
Putting the Pieces Together
9
Common RAID Levels
9
Hardware vs Software RAID
9
Red Hot RAID 6
10
3ware RAID Controller Part Number Matrix
10
Worldwide 3ware Distributors
and Sales Offices
11
1
Source: Gartner Dataquest Host Bus RAID Controllers Report (September 2006)
•
Industry leading 3ware® serial Attached sCsI and serial ATA
RAID controllers for performance, capacity and peace of mind
•
leading
1
supplier of sATA II hardware RAID controllers
and solutions to premier channel partners
•
over 3.0 million sATA ports shipped

SAS
3ware
®
9690sA
High Performance Serial Attached SCSI (SAS)
RAID Controllers
3ware pioneered the way for SATA and now capitalizes on time-
proven serial storage expertise to take users from parallel SCSI to
SAS. The 9690SA seizes the moment to enter the market just as
SAS hard drives, expanders and backplanes are more widely available
and as enterprise infrastructures align to realize the potential of
Serial Attached SCSI. As SAS makes inroads into the SCSI market,
users will look to SAS to provide expanded connectivity and greater
scalability and to the 3ware 9690SA for peace of mind.
Expand Your Horizon
with
SAS
Connectivity,
Data Protection
and
Performance
.
2
9690SA-8I
9690SA-8E
9690SA-4I4E
9690SA-4I
Form Factor
Low profile
Low profile
Low profile
Low profile
SAS Ports
8 Internal
8 External
4 Internal/4 External
4 Internal
Drive Interface
SAS and SATA
SAS and SATA
SAS and SATA
SAS and SATA
PCI Express
x8
x8
x8
x8
RAID Levels
0, 1, 5, 6, 10, 50,
Single Disk
0, 1, 5, 6, 10, 50,
Single Disk
0, 1, 5, 6, 10, 50,
Single Disk
0, 1, 5, 6, 10, 50,
Single Disk
Onboard Memory
512MB DDR2 533
512MB DDR2 533
512MB DDR2 533
512MB DDR2 533
Connector Type and Quantity
2X SFF-8087 mini-SAS
2X SFF-8088 mini-SAS
1X SFF-8087/1X SFF-8088 mini-SAS
1X SFF-8087 mini-SAS
BBU with Remote Battery Support
Yes
Yes
Yes
Yes
3ware 9690sA specifications
• Scalable to 128 SAS and/or Serial ATA devices
• PCI Express eight lane (x8) host interface
• Configuration flexibility with four configuration options
— 8 internal ports
— 8 external ports
— 4 internal/four external ports
— 4 internal ports
• SAS, SATA, and SATA II features, including 3Gb/s and NCQ
• Low profile form factor
• 512MB DDR2 533 ECC protected memory
• RAID levels 0, 1, 5, 6, 10, 50 and Single Disk
• RoHS 6 of 6 and WEEE compliant
3ware 9690sA series selection Guide

SATA
3ware
®
9650se
High Performance PCI Express to Serial ATA II RAID Controllers
The best keeps getting better with red hot RAID 6
AMCC’s 3ware 9650SE SATA II hardware RAID controllers deliver industry-leading
RAID 6 and RAID 5 performance, robust fault tolerance, and multi-terabyte capacities.
A PCI Express host interface, Multi-lane
™
connectivity, StorSwitch
™
architecture,
and sophisticated SATA II features drive this unrivaled performance.
3ware 9650se specifications
• PCI Express x1, x4, x8 configurations
• Serial ATA II advanced features
— 3Gb/s transfer speed
— Native Command Queuing
• Low profile form factor
— 2, 4, 8-port configurations
• Full height form factor
— 12, 16, 24-port configurations
• RAID levels: 0, 1, 5, 6, 10, 50, Single Disk, JBOD
(see chart below)
• RoHS 6 of 6 and WEEE compliant
3ware 9650se series selection Guide
9650SE-2LP
9650SE-4LPML
9650SE-4LPME
9650SE-8LPML
9650SE-12ML
9650SE-16ML
9650SE-24M8
Form Factor
Low profile
Low profile
Low profile
Low profile
Full height
Full height
Full height
Port Count
2
4
4
8
12
16
24
Drive Interface
SATA
SATA
SATA
SATA
SATA
SATA
SATA
PCI Express
x1
x4
x4
x4
x8
x8
x8
RAID Levels
0, 1, Single Disk, JBOD
0, 1, 5, 10,
Single Disk, JBOD
0, 1, 5, 10,
JBOD
0, 1, 5, 6, 10, 50,
Single Disk, JBOD
0, 1, 5, 6, 10, 50,
Single Disk, JBOD
0, 1, 5, 6, 10, 50, Single
Disk, JBOD
0, 1, 5, 6, 10, 50,
Single Disk, JBOD
Onboard Memory
128MB DDR2 533
256MB DDR2 533
256MB DDR2 533
256MB DDR2 533
256MB DDR2 533
256MB DDR2 533
512MB DDR2 533
Connector Type
Discrete
Multi-lane
Multi-lane (external)
Multi-lane
Multi-lane
Multi-lane
Multi-lane
BBU Support
No
Yes
Yes
Yes
Yes
Yes
Yes
SATA
3ware
®
9550sXU*
High Performance PCI-X to Serial ATA II RAID Controllers
High Performance PCI-X RAID solution of Choice
The 3ware 9550SXU SATA II RAID controller delivers performance, robust fault-tolerance,
and multi-terabyte capacities. Combined with an advanced RAID management
feature set that includes web-based, command-based, and API software components,
the 9550SXU, available in 4, 8, 12, and 16-port configurations, is the most compelling
PCI-X solution available.
3ware 9550sXU specifications
• PCI-X 1.0b (and PCI 2.3) compliant
— 64-bit/133/100/66MHz bus master
• Serial ATA II advanced features
— 3Gb/s transfer speed
— Native Command Queuing
• Low profile (4 and 8-port) and full height form factors
• 4, 8, 12, and 16-port configurations
• RAID levels: 0, 1, 5, 10, 50, Single Disk, and JBOD
(see chart below)
• RoHS 6 of 6 and WEEE compliant
3ware 9550sXU series selection Guide
9550SXU-4LP
9550SXU-8LP
9550SXU-12
9550SXU-12MI
9550SXU-12ML
9550SXU-16ML
Form Factor
Low profile
Low profile
Full height
Full height
Full height
Full height
Port Count
4
8
12
12
12
16
Drive Interface
SATA
SATA
SATA
SATA
SATA
SATA
Host Interface
PCI-X
PCI-X
PCI-X
PCI-X
PCI-X
PCI-X
Host Interface Speed
64-bit/133MHz
64-bit/133MHz
64-bit/133MHz
64-bit/133MHz
64-bit/133MHz
64-bit/133MHz
RAID Levels
0, 1, 5, 10, Single Disk, JBOD
0, 1, 5, 10, 50, Single Disk, JBOD
0, 1, 5, 10, 50, Single Disk, JBOD
0, 1, 5, 10, 50, Single Disk, JBOD
0, 1, 5, 10, 50, Single Disk, JBOD
0, 1, 5, 10, 50, Single Disk, JBOD
Onboard Memory
128MB
128MB
256MB
256MB
256MB
256MB
Connector Type
Discrete
Discrete
Discrete
Multi-lane
Multi-lane
Multi-lane
*A “U” has been added to all 9550SX part numbers to denote RoHS 6 of 6 compliance
3

Multi-lane
™
High-Performance SAS and SATA Cable and Connector System
Get Connected via the Multi-lane
™
expressway
AMCC’s award winning Multi-lane design enables highly reliable and stream-
lined enterprise-class SAS and SATA storage solutions by greatly reducing the
number of cables needed to connect controllers, backplanes, and standard
SAS/SATA drives.
The Multi-lane SATA cable/connection system is fast, secure, simple, and
clutter free. It combines the RAID controller’s multiple SAS/SATA ports into
single locked connections. Multiple 3Gb/s lanes of SAS/SATA traffic travel
through just one cable from the RAID controller to the system backplane
or to multiple hard drives with a breakout cable.
Multi-lane sAs and sATA Cable and Connector systems
SFF-8088 to SFF-8088
(Multi-lane external SAS)
3ware Controller Model #
9690SA (-8E, -4I4E)
3ware order #
CBL-SFF8088SAS-10M (1.0 m)
CBL-SFF8088SAS-20M (2.0 m)
SFF-8087 to Discrete
(Forward breakout cable)*
3ware Controller Model #
9690SA (8I, 4I4E, 4I)
9650SE (-4LPML, -8LPML, -12ML, -16ML)
9550SXU (-12ML, -16ML)
3ware order #
CBL-SFF8087OCF-05M (0.5 m)
CBL-SFF8087OCF-06M (0.6 m)
CBL-SFF8087OCF-10M (1.0 m)
SFF-8087 to SFF-8087
(Multi-lane internal)
3ware Controller Model #
9690SA (-8I, -4I4E, 4I)
9650SE (-4LPML, -8LPML, -12ML, -16ML)
9550SXU (-12ML, 16ML)
3ware order #
CBL-SFF8087-05M (0.5 m)
CBL-SFF8087-06M (0.6 m)
SFF-8088 to SFF-8470
(Multi-lane external SAS converter cable)
3ware Controller Model #
9690SA (-8E, -4I4E)
3ware order #
CBL-SFF8088IB-10M (1.0 m)
CBL-SFF8088IB-20M (2.0 m)
SFF-8087 to SFF-8482
(Forward SAS breakout cable w/ drive
power connectors)
3ware Controller Model #
9690SA (-8I, -4I4E, 4I)
3ware order #
CBL-SAS8087OCF-06M (0.6 m)
Multi-lane benefits
•
Multiple lanes of high speed SAS and/or SATA traffic through
a single cable
•
Increased system reliability
•
Reduced cable count
•
Streamlined storage
•
Locked connections
•
Improved airflow
5
* Breakout cables have a Multi-lane connector on one end and discrete connectors on the other end
• Forward breakout cables have a Multi-lane connector on the controller end and discrete connectors to the drives
• Reverse breakout cables have discrete connectors on the controller end and a Multi-lane connector to the backplane
Note: Cable color may differ from colors shown
SFF-8087 to SFF-8470
(Bi-directional Multi-lane hybrid cable)
3ware Controller Model #
9650SE (-4LPML, -8LPML, -12ML, -16ML)
9550SXU (-12ML, -16ML)
(SFF-8087 on controller)
3ware order #
CBL-SFF8087IB-05M (0.5 m)
CBL-SFF8087IB-06M (0.6 m)
SFF-8470 to SFF-8087
(Bi-directional Multi-lane hybrid cable)
3ware Controller Model #
9550SXU-12MI
3ware order #
CBL-SFF8087IB-05M (0.5 m)
CBL-SFF8087IB-06M (0.6 m)
SFF-8470 to SFF-8470
(Multi-lane internal)
3ware Controller Model #
9550SXU-12MI
3ware order #
CBL-IB-05M (0.5 m)
CBL-IB-10M (1.0 m)
SFF-8470 to Discrete
(Forward breakout cable)*
3ware Controller Model #
9550SXU-12MI
3ware order #
CBL-OCF-18 (0.5 m)
CBL-OCF-10M (1.0 m)
Discrete to SFF-8470
(Reverse breakout cable)*
3ware Controller Model #
9550SXU (-4LP, -8LP, -12)
9500S-4LP
3ware order #
CBL-OCR-18 (0.5 m)
CBL-OCR-10M (1.0 m)
Discrete SATA
(Standard, point-to-point SATA cable)
3ware Controller Model #
9650SE-2LP
9550SXU (-4LP, -8LP, -12)
9500S-4LP
8006-2LP
3ware order #
CBL-SATA-39 (39”/1 m)
M8 to Discrete
(Forward breakout cable)*
3ware Controller Model #
9650SE-24M8
3ware order #
CBL-M8OCF-06M (0.6 m)
CBL-M8OCF-10M (1.0 m)
M8 to SFF-8087
(Multi-lane internal “Y” cable)
3ware Controller Model #
9650SE-24M8
3ware order #
CBL-M8ML-06M (0.6 m)
Discrete to SFF-8087
(Reverse breakout cable)*
3ware Controller Model #
9550SXU (-4LP, -8LP, -12)
9500S-4LP
3ware order #
CBL-SFF8087OCR-05M (0.5 m)
CBL-SFF8087OCR-06M (0.6 m)
CBL-SFF8087OCR-10M (1.0 m)

Controller
Connector to Connector Options
Cable P/N Options
Cable Description
Where Used
To Controller
To Drives /
Backplane
3ware 9690SA SAS/SATA RAID Controllers
9690SA-8I
SFF-8087
SFF-8087
CBL-SFF8087-05M
0.5 meter cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s
Multi-lane SFF-8087 connector(s)
CBL-SFF8087-06M
0.6 meter cable
SFF-8087
SFF-8482
CBL-SAS8087OCF-06M
0.6 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four
individual SAS or SATA drives; includes individual drive power connectors
SFF-8087
Discrete
CBL-SFF8087OCF-05M
0.5 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to
the drives’ or backplane’s discrete SATA connector(s)
CBL-SFF8087OCF-06M
0.6 meter forward breakout cable
CBL-SFF8087OCF-10M
1.0 meter forward breakout cable
9690SA-8E
SFF-8088
SFF-8088
CBL-SFF8088SAS-10M
1.0 meter cable
Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s
Multi-lane SFF-8088 connector(s)
CBL-SFF8088SAS-20M
2.0 meter cable
SFF-8088
SFF-8470
CBL-SFF8088IB-10M
1.0 meter cable (converter cable)
Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s
Multi-lane SFF-8470 connector(s)
CBL-SFF8088IB-20M
2.0 meter cable (converter cable)
9690SA-4I4E
SFF-8088
SFF-8088
CBL-SFF8088SAS-10M
1.0 meter cable
Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s
Multi-lane SFF-8088 connector(s)
CBL-SFF8088SAS-20M
2.0 meter cable
SFF-8088
SFF-8470
CBL-SFF8088IB-10M
1.0 meter cable (converter cable)
Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s
Multi-lane SFF-8470 connector(s)
CBL-SFF8088IB-20M
2.0 meter cable (converter cable)
SFF-8087
SFF-8087
CBL-SFF8087-05M
0.5 meter cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s
Multi-lane SFF-8087 connector(s)
CBL-SFF8087-06M
0.6 meter cable
SFF-8087
SFF-8482
CBL-SAS8087OCF-06M
0.6 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four
individual SAS or SATA drives; includes individual drive power connectors
9690SA-4I
SFF-8087
SFF-8087
CBL-SFF8087-05M
0.5 meter cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s
Multi-lane SFF-8087 connector(s)
CBL-SFF8087-06M
0.6 meter cable
SFF-8087
SFF-8482
CBL-SAS8087OCF-06M
0.6 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four
individual SAS or SATA drives; includes individual drive power connectors
SFF-8087
Discrete
CBL-SFF8087OCF-05M
0.5 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to
the drives’ or backplane’s discrete SATA connector(s)
CBL-SFF8087OCF-06M
0.6 meter forward breakout cable
CBL-SFF8087OCF-10M
1.0 meter forward breakout cable
3ware Controller/Cable Matrix
6
3ware 9650SE Internal RAID Controllers
9650SE-2LP
Discrete
Discrete
CBL-SATA-39
39” (1m) standard, discrete, point-to-point SATA cable
Connects a controller’s discrete SATA port(s) to the drives’
or backplane’s discrete SATA connector(s)
9650SE-4LPML,
-8LPML, -12ML,
-16ML
SFF-8087
SFF-8087
CBL-SFF8087-05M
0.5 meter cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to
the backplane’s SFF-8087 Multi-lane connector(s)
CBL-SFF8087-06M
0.6 meter cable
SFF-8087
Discrete
CBL-SFF8087OCF-05M
0.5 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s) to
the drives’ or backplane’s discrete SATA connector(s)
CBL-SFF8087OCF-06M
0.6 meter forward breakout cable
CBL-SFF8087OCF-10M
1.0 meter forward breakout cable
SFF-8087
SFF-8470
CBL-SFF8087IB-05M
0.5 meter converter cable (internal hybrid)
Connects the controller’s SFF-8087 Multi-lane (ML) connector(s)
to the backplane’s SFF-8470 Multi-lane (MI) connector(s)
CBL-SFF8087IB-06M
0.6 meter converter cable (internal hybrid)
9650SE-24M8
M8
SFF-8087
CBL-M8ML-06M
0.6 meter “Y” cable
Connects the controller’s M8 Multi-lane connector(s) to the
backplane’s SFF-8087 Multi-lane connector(s)
M8
Discrete
CBL-M8OCF-06M
0.6 meter forward breakout cable
Connects the controller’s M8 Multi-lane connector(s) to the drives’
discrete SATA connectors
CBL-M8OCF-10M
1.0 meter forward breakout cable

Controller
Connector to Connector Options
Cable P/N Options
Cable Description
Where Used
To Controller
To Drives /
Backplane
9550SXU-4LP,
-8LP, -12
Discrete
Discrete
CBL-SATA-39
39” (1m) standard, discrete, point-to-point SATA cable
Connects the controller’s discrete SATA port(s) to the drives’
or backplane’s discrete SATA connector(s)
Discrete
SFF-8087
CBL-SFF8087OCR-05M
0.5 meter reverse breakout cable
Connects the controller’s discrete SATA port(s) to the backplane’s
SFF-8087 Multi-lane connectors
CBL-SFF8087OCR-06M
0.6 meter reverse breakout cable
CBL-SFF8087OCR-10M
1.0 meter reverse breakout cable
Discrete
SFF-8470
CBL-OCR-18
0.5 meter reverse breakout cable
Connects the controller’s discrete SATA connector(s) to the
backplane’s SFF-8470 Multi-lane connector(s)
CBL-OCR-10M
1.0 meter reverse breakout cable
9550SXU-12MI
SFF-8470
SFF-8470
CBL-IB-05M
0.5 meter cable
Connects the controller’s SFF-8470 Multi-lane connector(s)
to the backplane’s SFF-8470 Multi-lane connector(s)
CBL-IB-10M
1.0 meter cable
SFF-8470
Discrete
CBL-OCF-18
0.5 meter forward breakout cable
Connects the controller’s SFF-8470 Multi-lane connector(s)
to the drives’ or backplane’s discrete SATA connector(s)
CBL-OCF-10M
1.0 meter forward breakout cable
SFF-8470
SFF-8087
CBL-SFF8087IB-05M
0.5 meter converter cable (internal hybrid)
Connects the controller’s SFF-8470 Multi-lane (MI) connector(s)
to the backplane’s SFF-8087 Multi-lane (ML) connector(s)
CBL-SFF8087IB-06M
0.6 meter converter cable (internal hybrid)
9550SXU-12ML,
16ML
SFF-8087
SFF-8087
CBL-SFF8087-05M
0.5 meter cable
Connects the controller’s SFF-8087 Multi-lane connector(s)
to the backplane’s SFF-8087 Multi-lane connector(s)
CBL-SFF8087-06M
0.6 meter cable
SFF-8087
Discrete
CBL-SFF8087OCF-05M
0.5 meter forward breakout cable
Connects the controller’s SFF-8087 Multi-lane connector(s)
to the drives’ or backplane’s discrete SATA connector(s)
CBL-SFF8087OCF-10M
1.0 meter forward breakout cable
SFF-8087
SFF-8470
CBL-SFF8087IB-05M
0.5 meter converter cable (internal hybrid)
Connects the controller’s SFF-8087 Multi-lane (ML) connector(s)
to the backplane’s SFF-8470 Multi-lane (MI) connector(s)
CBL-SFF8087IB-06M
0.6 meter converter cable (internal hybrid)
3ware 9500S and 8006 Internal RAID Controllers
7
9500S-4LP
Discrete
Discrete
CBL-SATA-39
39” (1m) standard, discrete, point-to-point SATA cable
Connects the controller’s discrete SATA port(s) to the drives’ or
backplane’s discrete SATA connector(s)
Discrete
SFF-8087
CBL-SFF8087OCR-05M
0.5 meter reverse breakout cable
Connects the controller’s discrete SATA port(s) to the backplane’s
SFF-8087 Multi-lane connectors
CBL-SFF8087OCR-06M
0.6 meter reverse breakout cable
CBL-SFF8087OCR-10M
1.0 meter reverse breakout cable
8006-2LP
Discrete
Discrete
CBL-SATA-39
39” (1m) standard, discrete, point-to-point SATA cable
Connects a controller’s discrete SATA port(s) to the drives’ or
backplane’s discrete SATA connector(s)
Multi-lane Quick Reference Chart
Cable/connector
Controller P/N Suffix
Connectivity
Also Known as
SFF-8470
MI
Internal
InfiniBand
SFF-8087
ML
Internal
Mini SAS 4i, Mini SATA Internal, iPass
SFF-8088
ME
External
Mini SAS 4x, Mini SATA External, iPass
M8
M8
Internal
—
Multi-lane SFF-8087 and M8 cables provide internal connectivity from the controller to drives or the backplane.
Multi-lane SFF-8088 cables provide external connectivity from the controller to external enclosures.
External
SFF-8088
Internal
SFF-8087 or
M8
Backplane
SFF-8087 or
SFF-8470

bbU Availability features
•
Maximum reliability with cached write data protection
•
Missing Array Detection
•
Write Journaling
•
Dynamic Sector Repair
•
Drive Power-On Reset Detection
•
Extensive Drive Timeout Recovery
•
Out of Band Signaling Retry
•
Up to 72 hours of data protection in the event of
power failure
battery Mounting option
•
Battery attaches directly to the BBU Control Module
•
The BBU Control module mounts directly to the
RAID controller
Compatible RAID Controllers
•
3ware 9650SE
•
3ware 9550SXU
bbU Availability features
•
Includes all BBU-MODULE-03 features
+ Remote battery mounting capability for design flexibility
battery Mounting options
•
Battery can attach to a BBU daughter card in various positions
•
Battery can attach remotely to chassis wall, both internally and externally
•
Remote mounting kit without battery available separately
Compatible
RAID Controllers
•
3ware 9690SA
•
3ware 9650SE
•
3ware 9550SXU
bbU-MoDUle-03
bbU-MoDUle-04
battery backup Units
1
2
3
2
2
2
3
3
3
1
1
1
1
2
3
2
2
2
3
3
3
1
1
1
1
2
3
2
2
2
3
3
3
1
1
1
1
2
3
2
2
2
3
3
3
1
1
1
Battery placement options
8
3ware RAID Controller
features and benefits
StorSwitch
™
Non-blocking switch fabric architecture
Maximizes controller throughput by allowing concurrent communications with all attached
SATA drives through a pool of 32 direct memory access (DMA) channels.
Performance
StorSave
Powerful reliability enhancements
Achieves unmatched data protection while maximizing performance in critical RAID modes
when data availability, accessibility, and data protection are most needed.
Data Protection
StreamFusion
Intelligent cache algorithm
Maximizes application performance under heavy loads by dynamically allocating controller
cache for maximum bandwidth
Performance
Multi-lane
™
Award-winning connector system
Dramatically increases subsystem reliability by radically reducing cable count and improves airflow
Reliability & Convenience
RAID 6
(On select 3ware 9690SA and 9650SE
controllers)
Two sets of parity are simultaneously calculated, written, and rotated across all the drives.
This allows the array to survive up to two drive failures without losing data, for significantly
improved fault tolerance.
Data Protection
Advanced Content Streaming
(9690SA and 9650SE Controllers)
Aggressively Caches write and read data and improves write and read content streaming.
Provides intelligent caching algorithms to improve application performance in real world cases.
Application Performance
Hybrid Initialization
(9690SA and 9650SE Controllers)
Faster foreground initialization for RAID 5 and RAID 6 arrays with 16 or more drives.
Fastest background initialization for newly created arrays.
Array Availability
and Performance
Accelerated RAID Recovery
(9690SA and 9650SE Controllers)
Faster rebuild completion. Shorter verify/initialization.
Data Accessibility
and Availability

Putting the Pieces Together
Advanced 3ware RAID Features and Performance Architecture
storswitch
™
maximizes controller throughput
— StorSwitch is a unique non-blocking switch
fabric architecture that allows 3ware controllers to concurrently communicate to all attached SATA
drives through a pool of 32 direct memory access (DMA) channels for unparalleled performance
and data availability. The result is superior overall system performance compared to non-scalable
hub-based systems that share the bandwidth of a single DMA channel.
storsave optimizes data protection and performance
— StorSaves’s revolutionary combination
of powerful reliability enhancements and a battery backup unit (BBU) maximize data protection
and system reliability without sacrificing controller performance. StorSave permits 3ware controllers
to use both controller cache and disk cache during SATA RAID operations. This strengthens array
performance during optimal usage, as well as during degraded RAID 5 and RAID 6 operations which
means faster rebuild times. StorSave Profiles allow user-specified levels of protection vs. performance
(9690SA, 9650SE, 9590SE and 9550SXU only).
streamfusion maximizes application performance under multiple loads
— An intelligent
cache algorithm dynamically optimizes RAID 5 and RAID 6 disk accesses and efficiently manages
data through controller cache for guaranteed bandwidth. As the number of data streams increases,
the total bandwidth is divided equally among them. Application performance will not suffer
during heavy traffic or when multiple applications are accessing data simultaneously. 3ware RAID
controllers are not the performance bottleneck, as is often the case with software RAID and
other hardware RAID controllers.
Hard
Drive
Hard
Drive
Hard
Drive
Hard
Drive
Up to
1.5 Gb/sec
per port
3ware SATA Hardware
RAID Controller
Advanced
StorSwitch
Architecture
• Protects drive and controller cached writes in the event of a power loss
• Uses controller and drive write cache in all modes
• Dual caching for faster rebuild times
Block 10
Block 7
Block 4
P1 Parity
Disk #1
Block 11
Block 8
P2 Parity
Q1 Parity
Disk #2
Block 12
P3 Parity
Q2 Parity
Block 1
Disk #3
Q4 Parity
Block 9
Block 6
Block 3
Disk #5
Striped Data with Distributed Double Parity —
RAID 6
Host Data
P4 Parity
Q3 Parity
Block 5
Block 2
Disk #4
RAID
0
“Striping”
M
I
E
A
N
J
F
B
ETC. . .
L
H
D
O
K
G
C
RAID
1
“Mirroring”
D
C
B
A
D
1
C
1
B
1
A
1
=
RAID
5
“Rotational Parity”
3 Parity
A2
A1
A
0
B3
2 Parity
B1
B
0
D3
D2
D1
0 Parity
C3
C2
1 Parity
C
0
D2
D1
1
Drive 1
D2
1
D1
Drive 0
Drive 3
Drive 2
Stripe
RAID 10 "Striped Mirror"
SATA Disk
SATA Disk
SATA Disk
SATA Disk
Mirror
I/O
I/O
I/O
I/O
120
100
80
60
40
20
0
1
2
4
8
16
StreamFusion Performance
vs. Competition
StreamFusion assures scalable high performance
Iometer 2004.07.30dual Xeon 2.6 Ghz/1GB system/WinXP SP2/HDS7222525VLSA80/fw
V36OA60A/64KB stripes/RAID 5/all other settings at default
# Streams
AMCC
Competition 1
Competition 2
StreamFusion in Action
120
100
80
60
40
20
0
1
2
4
8
16
StreamFusion Performance vs. Competition
StreamFusion assures scalable high performance
Iometer 2004.07.30dual Xeon 2.6 Ghz/1GB system/WinXP SP2/HDS7222525VLSA80/fw
V36OA60A/64KB stripes/RAID 5/all other settings at default
# Streams
AMCC
Competition 1
Competition 2
StreamFusion in Action
9
Common RAID levels
RAID 0, 1, 5, 10 and JBOD
Block 10
Block 7
Block 4
P1 Parity
Disk #1
Block 11
Block 8
P2 Parity
Q1 Parity
Disk #2
Block 12
P3 Parity
Q2 Parity
Block 1
Disk #3
Q4 Parity
Block 9
Block 6
Block 3
Disk #5
Striped Data with Distributed Double Parity —
RAID 6
Host Data
P4 Parity
Q3 Parity
Block 5
Block 2
Disk #4
RAID
0 “Striping”
M
I
E
A
N
J
F
B
ETC. . .
L
H
D
O
K
G
C
RAID
1 “Mirroring”
D
C
B
A
D
1
C
1
B
1
A
1
=
RAID
5 “Rotational Parity”
3 Parity
A2
A1
A
0
B3
2 Parity
B1
B
0
D3
D2
D1
0 Parity
C3
C2
1 Parity
C
0
D2
D1
1
Drive 1
D2
1
D1
Drive 0
Drive 3
Drive 2
Stripe
RAID 10 "Striped Mirror"
SATA Disk
SATA Disk
SATA Disk
SATA Disk
Mirror
Block 10
Block 7
Block 4
P1 Parity
Disk #1
Block 11
Block 8
P2 Parity
Q1 Parity
Disk #2
Block 12
P3 Parity
Q2 Parity
Block 1
Disk #3
Q4 Parity
Block 9
Block 6
Block 3
Disk #5
Striped Data with Distributed Double Parity —
RAID 6
Host Data
P4 Parity
Q3 Parity
Block 5
Block 2
Disk #4
RAID
0 “Striping”
M
I
E
A
N
J
F
B
ETC. . .
L
H
D
O
K
G
C
RAID
1 “Mirroring”
D
C
B
A
D
1
C
1
B
1
A
1
=
RAID
5 “Rotational Parity”
3 Parity
A2
A1
A
0
B3
2 Parity
B1
B
0
D3
D2
D1
0 Parity
C3
C2
1 Parity
C
0
D2
D1
1
Drive 1
D2
1
D1
Drive 0
Drive 3
Drive 2
Stripe
RAID 10 "Striped Mirror"
SATA Disk
SATA Disk
SATA Disk
SATA Disk
Mirror
Block 10
Block 7
Block 4
P1 Parity
Disk #1
Block 11
Block 8
P2 Parity
Q1 Parity
Disk #2
Block 12
P3 Parity
Q2 Parity
Block 1
Disk #3
Q4 Parity
Block 9
Block 6
Block 3
Disk #5
Striped Data with Distributed Double Parity —
RAID 6
Host Data
P4 Parity
Q3 Parity
Block 5
Block 2
Disk #4
RAID
0 “Striping”
M
I
E
A
N
J
F
B
ETC. . .
L
H
D
O
K
G
C
RAID
1 “Mirroring”
D
C
B
D
1
C
1
B
1
=
RAID
5 “Rotational Parity”
3 Parity
A2
A1
A
0
B3
2 Parity
B1
B
0
D3
D2
D1
0 Parity
C3
C2
1 Parity
C
0
D2
D1
1
Drive 1
D2
1
D1
Drive 0
Drive 3
Drive 2
Stripe
RAID 10 "Striped Mirror"
SATA Disk
SATA Disk
SATA Disk
SATA Disk
Mirror
Hardware vs. Software RAID
All AMCC 3ware RAID controllers incorporate onboard processors to deliver true hardware RAID. Software RAID schemes use the system’s
processor, exploit host memory, compromise reliability and potentially rob the system of as much as 60% of its CPU cycles just to process
RAID calculations.
JBOD = J
ust a
B
unch
o
f
D
isks
• Applications requiring high bandwidth
performance but no fault tolerance
• Video production/editing
• Pre-press applications
• Provides fault tolerance and a read speed
advantage over non-RAID disks
• Applications requiring high availability
• Accounting
• Payroll
• Financial
• Most versatile RAID level providing performance,
fault tolerance and storage efficiency
• Video production/editing
• File and applications servers
• Database servers
• Email servers
• News servers
• Internet/Intranet
JBOD refers to an unconfigured disk attached to a RAID controller
• No fault tolerance
Block 10
Block 7
Block 4
P1 Parity
Disk #1
Block 11
Block 8
P2 Parity
Q1 Parity
Disk #2
Block 12
P3 Parity
Q2 Parity
Block 1
Disk #3
Q4 Parity
Block 9
Block 6
Block 3
Disk #5
Striped Data with Distributed Double Parity —
RAID 6
Host Data
P4 Parity
Q3 Parity
Block 5
Block 2
Disk #4
RAID
0 “Striping”
M
I
E
A
N
J
F
B
ETC. . .
L
H
D
O
K
G
C
RAID
1 “Mirroring”
D
C
B
A
D
1
C
1
B
1
A
1
=
RAID
5 “Rotational Parity”
3 Parity
A2
A1
A
0
B3
2 Parity
B1
B
0
D3
D2
D1
0 Parity
C3
C2
1 Parity
C
0
D2
D1
1
Drive 1
D2
1
D1
Drive 0
Drive 3
Drive 2
Stripe
RAID 10 "Striped Mirror"
SATA Disk
SATA Disk
SATA Disk
SATA Disk
Mirror
• Data is first mirrored, then striped across across
the drives to provide double drive failure
protection without the parity calculation
performance penalty of RAID 5 and RAID 6.
The mirror provides the redundancy.
• Ability to recover from a drive failure in either
mirrored set

Red Hot RAID 6
The fastest RAID 6 available
RAID 6 eliminates the risk of data loss if a second hard disk drive fails
while the RAID array is rebuilding. In a 3ware RAID 6 system, two sets
of parity are calculated, written, and rotated across all the drives.
This second simultaneous P + Q parity calculation allows the array
to survive up to two drive failures without losing data, for significantly
improved fault tolerance. RAID 6-enabled 9690SA and 9650SE control-
lers deliver unequaled RAID 6 performance.
RAID 6 represents a sea change in the RAID landscape. It provides
the industry with higher levels of data protection, data availability and
fault tolerance than RAID 5. By assuring data availability following a
second drive failure, users can rest assured that they are enjoying
maximum data protection, both in normal and degraded modes.
And, with RAID 6-enabled 3ware controllers, RAID 6 will not cripple
performance.
RAID 6 enabled 3ware Controllers
• 9690SA-8I
• 9650SE-8LPML
• 9690SA-8E
• 9650SE-12ML
• 9690SA-4I4E
• 9650SE-16ML
• 9690SA-4I
• 9650SE-24M8
3ware RAID 6: Two sets of parity data, P + Q, are striped across
disks. RAID 6 safeguards against data loss during rebuild mode
by allowing up to two consecutive drive failures for maximum
fault tolerance.
RAID 6 is recommended for:
• High capacity systems with eight or more
high capacity drives
• Enterprise/mission critical installations
Block 10
Block 7
Block 4
P1 Parity
Disk #1
Block 11
Block 8
P2 Parity
Q1 Parity
Disk #2
Block 12
P3 Parity
Q2 Parity
Block 1
Disk #3
Q4 Parity
Block 9
Block 6
Block 3
Disk #5
Striped Data with Distributed Double Parity —
RAID 6
Host Data
P4 Parity
Q3 Parity
Block 5
Block 2
Disk #4
10
3ware 9650SE PCI Express-to-Serial ATA II Hardware RAID Controllers
Model Number
Host Interface
Ports
RAID Levels
Controller Connector
Footprint
RoHS
9650SE-2LP
PCI Express x1
2
0, 1, Single Disk, JBOD
Discrete
Low profile
6/6
9650SE-4LPML
PCI Express x4
4
0, 1, 5, 10, Single Disk, JBOD
Multi-lane (SFF-8087)
Low profile
6/6
9650SE-4LPME
PCI Express x4
4
0, 1, 5, 10, JBOD
Multi-lane (SFF-8088)
Low profile
6/6
9650SE-8LPML
PCI Express x4
8
0, 1, 5, 6, 10, 50, Single Disk, JBOD
Multi-lane (SFF-8087)
Low profile
6/6
9650SE-12ML
PCI Express x8
12
0, 1, 5, 6, 10, 50, Single Disk, JBOD
Multi-lane (SFF-8087)
Full height
6/6
9650SE-16ML
PCI Express x8
16
0, 1, 5, 6, 10, 50, Single Disk, JBOD
Multi-lane (SFF-8087)
Full height
6/6
9650SE-24M8
PCI Express x8
24
0, 1, 5, 6, 10, 50, Single Disk, JBOD
Multi-lane custom hybrid
Full height
6/6
3ware 9550SX PCI-X-to-Serial ATA II Hardware RAID Controllers
Model Number
Host Interface
Ports
RAID Levels
Controller Connector
Footprint
RoHS
9550SXU-4LP
64-bit/133MHz
4
0, 1, 5, 10, Single Disk, JBOD
Discrete
Low profile
6/6
9550SXU-8LP
64-bit/133MHz
8
0, 1, 5, 10, 50, Single Disk, JBOD
Discrete
Low profile
6/6
9550SXU-12
64-bit/133MHz
12
0, 1, 5, 10, 50, Single Disk, JBOD
Discrete
Full height
6/6
9550SXU-12MI
64-bit/133MHz
12
0, 1, 5, 10, 50, Single Disk, JBOD
Multi-lane (SFF-8470)
Full height
6/6
9550SXU-12ML
64-bit/133MHz
12
0, 1, 5, 10, 50, Single Disk, JBOD
Multi-lane (SFF-8087)
Full height
6/6
9550SXU-16ML
64-bit/133MHz
16
0, 1, 5, 10, 50, Single Disk, JBOD
Multi-lane (SFF-8087)
Full height
6/6
3ware RAID Controller Part number Matrix
3ware 9690SA SAS/SATA Hardware RAID Controllers
Model Number
Host Interface
Ports
RAID Levels
Controller Connector
Footprint
RoHS
9690SA-8I
PCI Express x8
8 Internal
0, 1, 5, 6, 10, 50, Single Disk
SFF-8087 mini-SAS
Low profile
6/6
9690SA-8E
PCI Express x8
8 External
0, 1, 5, 6, 10, 50, Single Disk
SFF-8088 mini-SAS
Low profile
6/6
9690SA-4I4E
PCI Express x8
4 Internal/4 External
0, 1, 5, 6, 10, 50, Single Disk
SFF-8087 / SFF-8088 mini-SAS
Low profile
6/6
9690SA-4I
PCI Express x8
4 Internal
0, 1, 5, 6, 10, 50, Single Disk
SFF-8087 mini-SAS
Low profile
6/6

3ware 8006 PCI-to-Serial ATA Hardware RAID Controller
Model Number
Host Interface
Ports
RAID Levels
Controller Connector
Footprint
RoHS
8006-2LP
64-bit/66MHz
2
0, 1, JBOD
Discrete
Low profile
5/6
3ware Controller Specifications
Operating Systems
Microsoft® Windows® 2003/XP/2000, Red Hat Linux, SuSE Linux, Fedora
Linux, 2.4 Linux kernel, 2.6 Linux kernel, FreeBSD, 32/64-bit support,
Mac OS X (10.4.6 and above)
For complete OS listing, go to: www.3ware.com/support/OS-support
PCI Compliance
PCI Express 1.1, PCI-X 1.0b, and PCI 2.3 compliant
(64-bit/133/100/66MHz bus master)
Serial Interface
SATA and SATA II (1.5/ 3Gb/s), and SAS
RAID Features
RAID 6 on select 3ware 9650SE controllers, RAID Level Migration, online
capacity expansion, hot swap/hot spare, S.M.A.R.T. disk drive monitoring,
multiple card support, multiple logical volumes and RAID levels, remote
management, alert notifications and more
SCSI Features
Scatter/gather, command queuing, command reordering, elevator seek,
dynamic sector repair, background media scanning and more
SATA II Features
3Gb/s, Native Command Queuing, OOB Staggered Spin-up (compliant with
the SATA 2.6 specification)
Kit Contents
SAS/SATA II/SATA RAID controller and cables, CD including driver, 3ware
Disk Manager 2 (3DM®2), Command Line Interface (CLI), User Guide,
Printed Installation Documentation
Warranty
3 years
Support
Free technical support, advanced replacement option
3ware Controller Accessories
Model Number
Description
BBU-MODULE-03
Battery Backup Unit for 3ware 9650SE/9590SE/9550SX(U)
BBU-MODULE-04
Battery Backup Unit for 3ware 9690SA/9650SE/9590SE/
9550SX(U); Includes remote battery mounting kit
BATT-SPARE-02
Replacement battery for BBU-MODULE-03 and
BBU-MODULE-04
BBU-9500S-01
Battery Backup Unit for 3ware 9500S
BATT-9500S-SPARE
Replacement battery for BBU-9500S-01
RDC-400-SATA
SATA internal drive cage
RDC-TRAY-SATA
SATA drive tray (to be used with the RDC-400-SATA)
RDE-TRAY-01
Spare drive tray for 3ware Sidecar
CABLES
Please reference the cable datasheet
3ware Distributors
N o r t h A m e r i c a
Bell Micro
(US and Canada)
www.bellmicro.com
D&H
(US)
www.dandh.com
Ingram Micro
(US)
www.ingrammicro.com
Synnex
(US and Canada)
www.synnex.com
L a t i n A m e r i c a
Bell Micro
www.bellmicro.com/latinamerica
E u r o p e , M i d d l e E a s t a n d A f r i c a
Asbis
www.asbis.com
Avnet
www.avnet.com
Bell Micro
www.bellmicro.eu.com
Hammer
www.hammerplc.com
CTT
www.ctt.de
TMC
www.tmc-uk.com
A s i a P a c i f i c
APT
(China)
www.apt-storage.com
ASK
(Japan)
www.ask-corp.co.jp
Digicor
(Australia)
www.digicor.com.au
Epecom Graphics
(Singapore)
www.epecomgraphics.com.sg
Postium Korea Co., Ltd.
(Korea)
www.postium.co.kr
Synnex K.K.
(Japan)
www.synnex.co.jp
Worldwide 3ware Distributors
and sales offices
THC
(China)
www.thcsy.com
Upmost Technology Corp.
(Taiwan)
www.upmost.com.tw
3ware Sales Offices
Company Headquarters
(USA)
215 Moffett Park Drive
Sunnyvale, CA 94089
Tel:
+1-408-542-8771
+1-877-883-9273
Email: 3waresales
@
amcc.com
www.3ware.com
Europe
+44-1494-890700
Asia/Pacific
+65-6826-3381
China
+86-10-6581-4916
11