Operation Guide 3M-30
The 3M-30 programmable communicating
thermostat operates via a high-quality, easy-
to-use touch screen. To program or adjust
your 3M-30, simply touch your finger firmly to
the screen. The screen will automatically light
up and you will hear a “beep.” The screen will
respond differently to different types of touches,
so you may want to experiment by touching it
different ways, finger, fingernail, etc. Do not use
a sharp or metallic device; it will scratch the
screen.
ENGLISH
Statement of use:
100% Compatible with all popular
residential HVAC systems; 24VAC single, two stage
conventional heating systems (gas/oil/electric), heat pumps,
single stage or with auxilliary heat (electric or fossil),
zoned forced air and zoned hot water (2 or 3 wire), millivolt
systems (with 24VAC adapter), one or two stage cooling,
and hybrid systems.
button
Save
Energy
button
Power Grid
status
indicator
top cover
Touch screen
Wire
terminals
Mode
Fan
MENU
button
PROG
Reset
button
HVAC
selections
switches
bottom
cover
DAY
F
LINK
RADIO
TARGET TEMP
1
COOL
AUTO
PM
switch
switch
1005-002-001

PG
2
PG
2
Control Screens
Before you operate the 3M-30 please get familiar with these basic control screens. All the 3M-30
functions are accessed through these screens. HOME, MENU, PROGRAM and MANUAL . The
3M-30 touch screen technology allows you to select (by touching) an item and change it using the +/-
arrows or the time arrows.
HOME Screen
The
HOME
screen is displayed when the
unit is operating. Touching the HOME icon
on the screen will always return you to
this screen.
To set a Mode:
Set the mode switch on the side to the
desired mode COOL or HEAT.
FAN
MODE
-
HEAT-OFF-COOL
DAY
PM
TARGET TEMP
HEAT
Thermostat
Mode
Time of day
Current Room
Temperature
Lock indicator
Target
Temperature
Day

PG
2
PG
2
PG
3
MENU Screen
The
MENU
screen is the gateway to many functions or settings of the
3M-30. It is displayed when you press the MENU button.
[See page 9 for details]
DIFF SWING
FILTER
PM
F
C
HVAC
SETUP
CALIBRATE
Set Day
Touch this area to set
the day of the week
Set Time
Touch this area to set
the time of day.
Left arrow goes back,
right arrow goes forward.
Calibration control
Use this to calibrate your
LCD display match to
another thermometer.
Set
o
C -
o
F
Touch this to set
temperature display.
Lock Program
Touch for 5 sec
to lock or unlock.
Filter Timer
set
Chirp set
Touch this to turn the
audible chirp on or off.
Temperature Swing set
Differential set
for 2nd Stage
HOME
Touch to
return to
HOME
screen.
HVAC SETUP
Touch this to configure the
3M30 to work with your
HVAC system.

PG
4
PG
4
PROGRAM Screen
The
PROGRAM
screen sets the 3M-30 control for your
home HVAC system. It is displayed when you press the PROG button.
[See page 7 for details]
PROGRAM
MORN
AM
F
COPY
DAY
HEAT
Set Program Day
Touch this area to set the day of the
week you want to program TargetTemps for.
Set Time Slot
Touch this area to set the
Time Slot you want to program.
Set Program Time
Touch this area to set the
time of day you want each
time period to start.
Left arrow goes back,
right arrow goes forward.
[Touch and hold for fast set]
Copy
Touch this area to copy
current day’s program
to the next day.
Temp Up / Temp Down
Touch these to raise
and lower each Target Temp.
[Touch and hold for fast set]
Return HOME
When programming is complete
touch this to run your program and
return to the HOME screen.

PG
4
PG
4
PG
5
MANUAL Screen
The
Manual Screen
control screen is where you can make
temporary changes to your 3M-30’s operation. Touch the main temperature display to use this
screen.
[See page 12 for details]
HOLD
TEMPORARY
F
TEMP
HOLIDAY
HEAT
Target Temperature
Room Temperature
Return HOME
Temp Up / Temp Down
arrows
Touch these to raise and lower
the manual override Target Temp.
HOLIDAY
Touch this to invoke a
single program that repeats day
after day until you turn it off.
HOLD
Touch this area to operate the thermostat as
a manual thermostat. It will keep the temperature
you set until you change it or cancel
HOLD.
Manual Override indicator
Shows TEMPORARY when
you have modified the Target.

PG
6
PG
6
Initial Settings
Press
MENU
to prepare the thermostat (from HOME screen).
Set day of the week -
Touch the Day of the week area to cycle through the days of the week to select the current day.
Set time of day -
Touch the Time of Day arrows to move the time selection forward or backward until
it displays the current time. Touch and hold for faster setting.
Set oF-oC display -
Touch the oF and it will toggle to oC.
Set audible chirp -
Touch the musical note icon to select the chirp
or no chirp.
Return
HOME
by touching the
icon.
Forward
Backward

PG
6
PG
6
PG
7
Auto-run Program
The 3M-30 comes pre-programmed with an EPA approved program. This program is recommended
by the EPA for energy efficiency. We strongly recommend that you Auto-Run this program for one
week, and see if it works for you. If it does not fit your needs you can always input a custom program.
To run the EPA program, set the mode switch to HEAT or COOL.
Press the MENU button and use the arrows by the time display to set the time.
Touch the DAY area and advance it to select the present day.
Touch HOME. The unit is now running the program.
t
All Days
70
o
F 62
o
F 70
o
62
o
F
MORN
6:00am
HEAT
DAY
8:00am
EVEN
6:00pm
NITE
10:00pm
All Days
78
o
F 85
o
F 78
o
F 82
o
F
MORN
6:00am
COOL
DAY
8:00am
EVEN
6:00pm
NITE
10:00pm
EPA
TO CHANGE THE PROGRAM:
Make sure the 3M-30 mode switch is set to either HEAT or COOL, then press the
PROGRAM
button.
This puts you at the
PROGRAM
screen [see page 4]. The programmed start time is diplayed in the
upper left. The TIME SLOT icon indicates the active TIME SLOT in the default program [MORN, DAY,
EVEN, NITE]. The programmed Target Temperature is shown on main display.
The HEAT program and the COOL programs are separate.

PG
8
PG
8
Select the
day
you want to program.
The day of the week starts at SU - Sunday and can be advanced to the day you want to program.
Touch the day of the week area to cycle through the days of the week to the desired day.
Select the
time slot
(period) you want to program (MORN,DAY, EVEN, NITE).
Touch the time slot area to cycle through to the desired period.
Select the desired
start time
of that time slot.
Touch the time arrows to select the desired period’s starting time. Hold arrow down for fast time
scrolling.
Select the desired
target temperature
for that time slot.
Touch the +/- arrows to select the desired period’s temperature.
To
COPY
one day’s programming to the next day, touch COPY DAY once. The information for the
current day will be copied to the next day which will appear on the screen. Holding down COPY for
over 3 seconds will copy to all 7 days.
Touch HOME to return to the Home screen.

PG
8
PG
8
PG
9
MENU Screen Functions
Press MENU to bring up MENU screen.
TIME of DAY
Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per
touch). Touch and hold the arrow for fast time set (15 minute jumps).
DAY of Week
Touch DAY area to select present day.
SWING
(HVAC cycling rate) This feature allows you to set the desired variance in temperature
between the 3M-30 setting and the room temperature required before the heating or cooling system
will turn on—from 0.5° to 2.0° F (.25° to 1° C). For example, if SWING is set to 2.0° F and the 3M-
30 is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F.
Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC then
runs and will shut off at the Target Temperature.
To set
SWING
:
Touch SWING.
Touch the left/right arrows to set the SWING from 0.5° to 2.0° F.
The HVAC will run more frequently at .5°F and less at 2°F. Default is 1°F.
Touch HOME to return to the MENU screen.

PG
10
PG
10
Chirp set
-
Touch this to turn the audible chirp sound on or off.
F
C
Set -
Touch this to switch the temperature display scale from oF to oC .
FILTER
- AIR FILTER ALERT - The 3M-30 can be programmed to remind you when the air filter
needs changing.
Touch FILTER. The display will show the usage to date.
Touch FILTER for over 3 seconds and the display will change to LIMIT.
Touch arrows to set desired usage limit before filter alert comes on home screen.
When this limit is reached, FILTER will be on home screen.
Limit may be set from 0 to 999 days; default is 90 days.
To reset, the usage back to 0, touch usage number; touching it again restores the displayed usage.
Touch HOME to return to the MENU screen.
LOCK
(The 3M-30 has 2 lock modes)
Touch icon for 5 seconds; the unit will go into the PARTIAL lock mode. The user can temporarily
override the 3M-30 Target Temperature with the +/- buttons only. (1 bar)
For FULL lock : Touch the icon again for 5 seconds to go to full lock. No changes can be made. Full
lock shows
(2 bars). Once locked, the 3M-30 will respond just to MODE and MENU.

PG
10
PG
10
PG
11
To UNLOCK , Press MENU.
Touch and hold icon for 5 seconds for 2 bars (if not there already).
Then touch and hold the icon for another 5 seconds. Each 5 second touch and hold must be separate.
Return
HOME
by touching the
icon.
CALIBRATE
Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient
temperature. You do have the option, however, to change the display temperature to match that of a
previous thermostat, or to match another thermostat already in your home. The range of change is from
-6°F to +6°F or -3°C to +3°C.
To change your Thermostat Calibration,
touch
MENU
and then touch
CALIBRATE.
Use the + / - to adjust the displayed temperature up or down, as desired.
The DELTA FACTOR that appears on the screen will also automatically increase or decrease for
each 0.5° (F or C) adjustment so you can see your change. The large display will show the modified
temperature reading that will be displayed on the HOME screen and used as the new room temperature.
Press
HOME
to return to the Home screen.
DIFF
(Used for 2 stage normal or heat pump with auxillary only, not on screen for single stage).
The differential is the number of degrees between the room temperature and the Target Temperature at
which the 2nd stage will be used. Default is 2°F.
Touch
MENU
and then
DIFF
. use the arrows to set the
DIFF
.
Recommend
DIFF
be set to 2°F for very cold climates and to 4°F for warm climates.

PG
12
PG
12
MANUAL Screen Functions
The 3M-30 has 4 manual override commands. The manual screen is accessed by touching the large
current temperature display on the middle of the HOME screen.
IMPORTANT:
The Mode must be in HEAT or COOL to access the manual screen.
TEMPORARY override
Touch the + / - arrows to select your desired temporary Target Temperature.
Touch HOME to return to operation. The
TEMPORARY
icon will display indicating you have modified
the Target Temperature for the current Time Slot only. It goes back to the program target at the next
period. Also once in temporary, if the target is set the same as the programmed target for that period,
the word TEMPORARY will go out.
HOLD
This will hold the target temperature you set indefinitely, until you turn
HOLD
off.
HOLD
will allow
you to operate your thermostat as a manual thermostat. It will keep whatever temperature you set until
you change it or cancel hold. Take care using the
HOLD
function as the program is now bypassed. To set
a hold target temperature, touch
HOLD
and use the +/- icons to select your hold temperature. The
HOLD
icon will display on the HOME screen indicating you have changed the Target Temperature. The system
will
HOLD
this temperature until you return to the manual screen and de-select
HOLD
by touching it. Hold
is also canceled when you set the mode to OFF.
HOLIDAY
This is a single program that repeats day after day until you turn it off. It supersedes the
weekly program. To use it touch
HOLIDAY
on the temporary screen. The default holiday program is
shown below. To modify this program, touch the PROGRAM button and then touch the DAY area until

PG
12
PG
12
PG
13
HOLIDAY appears (after SAT). The default HOLIDAY program is set as 2 time slots; all day (same
target MORN, DAY and EVEN) and a different target for NITE. [Default program: HEAT 70
o
F all day
and 62
o
F at night. COOL 78
o
F all day and 82
o
F at night.]
EMER
(in HEAT PUMP type)
If you setup your 3M-30 for HEAT PUMP with auxiliary heat, EMER function is available with a
switch under the top cover on the right. If you switch EMER to ON, your heat pump is disabled and
auxiliary heat is your sole source of heat. This manual override stays active until you switch EMER
off. Auxiliary heat is more expensive than the heat pump so use EMER only if the heat pump cannot
keep up or is defective.
Other Functions
Save Energy Button
The “Save Energy” feature on the 3M-30 provides a simple, easy-to-use way to help you manage
your energy use. SAVE ENERGY automatically adjusts your Target Temperature up in COOL or
down in HEAT by 4
o
F. To use Save Energy, press the Save Energy button in the upper left corner
of the unit. The screen will now read “Save Energy”. To return to normal operation, press the “Save
Energy” button again. This is useful to save energy if you are gone for a short time.

PG
14
PG
14
FAN Switch
AUTO
: The fan control is normally in
AUTO
mode, meaning that the fan operates automatically with
the HVAC system and the thermostat. When the fan switch is in
ON
, the fan will run continuously until
switched back to
AUTO
.
[NOTE: Fan
ON
function is available in the OFF mode to allow simple ventilating.]
Simple Screen
This display mode limits the amount of information on screen and limits the functions to just the
+/- arrows. To access the limited display “Simple Sceen”, hold down the PROGRAM button for 12
seconds. Hold down the PROGRAM button for 12 seconds to leave the limited display screen.
RESET button
The RESET button re-boots the 3M-30 processor. It does not effect the user
programs that have been stored in permanent memory.
Compressor Protection
The 3M-30 has a minimum cycle time of 4 minutes to protect your
compressor in cool and in heat pump (if you have one). The Home screen will show a small clock and
A/C during this time and the compressor will not come on until the 4 minute delay is over.

PG
14
PG
14
PG
15
Communicating Thermostat
The 3M-30 has 2 RTM-1 radio ports. These allow your thermostat
to communicate with other systems. Depending on your area
power company, programs may be available to connect your
thermostat to power grid status information. This can make it easy
for you to moderate your energy use at peak hours and use power
when it is less expensive.
Using USNAP Radios
- The USNAP ports allow you to
connect your 3M-30 to your home WiFi network. This can give you
access to your home’s HVAC system even when you are away
[with additional web service]. It can also give you access to web
based efficient energy management sites that can help you save
money and protect the environment.You can connect your 3M-
30 to an AMI network for In Home Display of electric grid status or connect to a Home Automation
network for HA functionality with remote access to your HVAC system and home conditions.
To Insert a USNAP radio module:
Power off the 3M-30. Insert the radio module in either
slot on the back of the 3M-30. Power up 3M-30.
To connect
to a network follow the instructions that
came with the USNAP module.
USNAP port
USNAP
radio
Caution
DO NOT INSERT or REMOVE USNAP
radio
modules if power is ON. This can damage the
thermostat or radio modules.
Customer support: filtrete@radiothermostat.com
888-607-5824
or www.radiothermostat.com/filtrete