Quick Installation Guide

For the SuperStack

®

 II Switch 3900 and Switch 9300 Systems

This guide provides quick procedures for installing one or more of the 
SuperStack

® 

II Switch 3900 and the SuperStack

® 

II

 

Switch 9300 systems. 

The guide is intended for the network administrator who has experience 
installing communications equipment.

System Setup Tasks

To get your system and its components to the state at which you can 
connect to your network, follow the setup tasks in the figure. If you need 
more information on each setup task, see the related sections in this 
guide or complete details in the indicated documents.

green

=  enabled, link OK

flashing green

=  disabled, link OK

off

= link fail

1000 Base - SX

Super Stack II

Switch 9300

TX

RX

1

1000 Base - SX

10 Base - TX

1000 Base - LX

Console

TX

RX

2

TX

RX

3

TX

RX

4

TX

RX

5

TX

RX

6

TX

RX

7

TX

RX

8

TX

RX

9

TX

RX

10

TX

RX

11

TX

RX

12

Pckt

Stat

Pckt

Stat

Status

Status

1x

6x

12x

7x

13

18

24x

19x

25

30

36x

31x

green

= enabled, link OK

flashing green

= disabled, link OK

off

= link fail

Fault

Power

10/100 BASE - TX

2

3

1

10 11 12

4

5

6

7

8

9

2

3

1

10 11 12

4

5

6

7

8

9

1

1

1

17

1

18 19 20 21 22 23 24

1

1

1

17

1

18 19 20 21 22 23 24

2

2

2

29

2

30 31 32 33 34 35 36

2

2

2

29

2

30 31 32 33 34 35 36

Pckt

Stat

Pckt

Stat

Pckt

Stat

SuperStack

®

 II Switch 3900 (36-port)

SuperStack

®

 II Switch 9300

Install Gigabit Ethernet
Modules (Optional)

(Switch 3900 only)

1000BASE-SX/1000BASE-LX
Gigabit Ethernet Module
Installation Guide

5

6

Attach Cables to the System
and the Optional Modules

Getting Started Guide,

  Chapter  3

Install the Additional
Power Supply (Optional)

Advanced RPS Power Module
Type 2 User Guide

4

Install the System on a
Table Top or in a Rack

Getting Started Guide,
Chapter 2

3

Unpack the SuperStack II
Switch 3900 or 9300 System

Unpacking Instructions

2

Determine Site Requirements

Getting Started Guide,
Appendix B

Software Installation and
Release Notes

1

Administer and Operate
the System

Command Reference Guide and
the

 Implementation Guide

(on the Documentation CD)

10

Solve Problems

• This 

Quick Installation Guide

Getting Started Guide, Chapter 6

9

Configure the System for
Management

Getting Started Guide, Chapter 5

8

Power Up the System

Getting Started Guide,
Chapter 4

7

 


background image

2

Quick Installation Guide

Installing the 
System

To install the SuperStack II Switch 3900 or Switch 9300 system in your 
network, follow the steps in this section.

Audience

This guide is intended only for 

trained technical personnel

. Do not 

attempt to install or service a SuperStack II Switch 3900 or Switch 9300 if 
you do not have the proper training. For training information, call 
1-800-NET-3COM in the United States and Canada. For training 
information elsewhere, visit the 3Com website at www.3com.com.

WARNING:

 For your safety and to ensure adequate cooling airflow, keep 

blank faceplates over any empty slots on the Switch 3900.

Install the SuperStack II Switch 3900 or Switch 9300 system in an area 
that meets the requirements in Table 1.

For more information on site requirements, see Appendix B in the 

Getting 

Started Guide

 for your system

.

Check the packing slip to verify that you have all of the components that 
you ordered. 

The system is shipped with one internal power supply. If you have ordered 
a redundant power supply or uninterruptible power supply for the 
system, have it available for installation. 

Determine Site
Requirements

1

Table 1   

System Site Requirements

Location

Ambient (room) temperature — 0 to 50 °C (32 to 122 °F)

Relative humidity — 10% to 90%, noncondensing

A level surface for system installation 

Power

Power supply — 

100 to 240 VAC

Power source location — AC or DC power source within approximately 
1.8 meters (6 feet)

Input voltage options — 100 to 120 VAC or 200 to 240 VAC

Current rating — 

1.3 amperes at 120 volts

 

Unpack the
System

2

 


background image

Quick Installation Guide

3

Before You Begin

Before you install the system: 

Move the system close to where you plan to install it.

Have a Number 1 Phillips screwdriver available.

Have the hardware kit that comes with the system available. See 
Table 2.

Determine whether you are installing the system on a tabletop or in a 
distribution rack. 

For complete installation instructions, see Chapter 2 in the 

Getting 

Started Guide

 for your system. 

WARNING: 

Hazardous energy exists within the SuperStack II 

Switch 3900 and Switch 9300 systems. Follow instructions in the 

Getting 

Started Guide

 to avoid electric shock or equipment damage. Many 

installation and troubleshooting procedures should be performed only by 
trained technical personnel. 

The system operates using a single power supply assembly and is shipped 
with one internal power supply. 

You can connect an uninterruptible power supply (UPS). 

You can also connect a redundant power supply (RPS). 

These additional power supplies are orderable and shipped separately. 
Contact your network supplier.

For instructions on how to install the RPS, see the 

Advanced RPS 

Power Module Type 2 User Guide

.

Table 2   

Hardware Kit

Item

Qty Use in

Rubber feet (self-adhesive)

4

Installing the system on a table top

Mounting bracket

2

Installing the system in a distribution rack

M4 x 10 Phillips pan-head screws

6

Installing the system in a distribution rack

Install the
System

3

Install Optional
Power Supply

4

 


background image

4

Quick Installation Guide

If you have ordered one or two additional Gigabit Ethernet modules for 
your SuperStack II Switch 3900 system, you are now ready to install the 
modules. 

CAUTION: 

Electrostatic discharge (ESD) can damage components on a 

module, causing complete or intermittent failures. ESD damage occurs 
when the module is improperly handled. When handling modules, be 
sure to read and follow the ESD safety information provided in the 

Module Installation Guide

For installation instructions, see the 

1000BASE-SX/1000BASE-LX Gigabit 

Ethernet Module Installation Guide

 that is shipped with the module. 

Cable your system for connecting these elements to your network:

10/100BASE-T connectors (3900 only)

1000BASE-SX or LX connectors (3900 and 9300)

10BASE-T out-of-band port connector (9300 only)

Console port (3900 and 9300)

For information on cabling ports, see Chapter 3 in the 

Getting Started 

Guide

 for your system. 

Place the system near an easily accessible power outlet because the only 
way that you can power the system up or down is to insert or remove the 
power cord from the power source. To get your system powered up and 
ready to operate:

1

For the Switch 3900, verify that each unused slot is covered with a blank 
faceplate.

To view possible error messages in the Administration Console while the 
system is running power-up diagnostics, connect a terminal, workstation, 
or PC with terminal emulation software to the system’s Console port. 

2

On the back panel of either the Switch 3900 or the Switch 9300, plug the 
power cord into the power receptacle. 

CAUTION:

To prevent a possible fire hazard, be sure to fully insert the 

power cord.

3

Plug the other end of the power cord into a power outlet.

Install Modules
(Switch 3900 only)

5

Attach the
Cables

6

Power Up
the System

7

 


background image

Quick Installation Guide

5

LEDs and Power-up Diagnostics

Your system runs diagnostic software at power up. This software verifies 
that every component in the system is operating correctly. If any 
component fails during power-up diagnostics, the system either fails to 
power up or, for the Switch 3900, it prevents faulty modules from coming 
online. 

For diagnostic messages, view the system display in the Administration 
Console (if you have connected the system to a workstation). 

For the Switch 3900, when the system comes up, verify which modules, if 
any, have failed diagnostics by checking the module LEDs.

The system and port LEDs are described in Table 3. 

Table 3   

System and Port LEDs

LED

Name

Type

Color 
Indications

Description

Power

System 
power

Green

The system is powered up.

No light

The system is powered down.

Fault

System 
fault

Yellow

The system has failed diagnostics or 
some other operational error has 
occurred.

Blinking 
yellow

Diagnostic software is not running.

No light

The system is operational.

Pckt

Packet

Port 
activity

Yellow

Data is passing through the port.

Blinking 
yellow

Data is passing through the port.

No light

Data is not passing through the port.

Stat

Status

Port 
link

Green

The port is online.

Blinking 
green

The port is online but disabled.

No light

The port is off-line.

 


background image

6

Quick Installation Guide

Your system is shipped from the factory with IEEE 802.1D bridging set to 
disabled. To configure system features for your particular networking 
environment, you must first establish management access. 

Initially, you can only manage your system locally through a direct 
terminal connection to the Console port. You use this interface to 
configure additional access mechanisms, as shown in Table 4. 

For more information on access mechanisms, see Chapter 6 in the 

Getting Started Guide

 for your system or Chapter 2 in the 

Implementation Guide

.

Defining an Interface

Once you have configured initial access, you can manage your system in 
one of these ways:

In-band

 — Manages the system and its attached LANs over the same 

network that carries your regular data traffic. You configure an IP 
address on any Ethernet port. 

Out-of-band (9300) 

 

Uses a dedicated network for management 

data. You configure a system management interface for the Ethernet 
10BASE-T out-of-band port and assign it an IP address. 

Table 4   

System Management Access Mechanisms

Access 
Mechanism

Access Description

Interface

Terminal

Connect directly to the Administration Console 
and stay attached during system reboots

Console port

Modem

Access the Administration 
Console from remote sites

Console port 

IP 

Access the Administration Console using the 

rlogin

 or 

Telnet

 commands

Use an external SNMP management 
application (such as the 3Com Transcend

®

 

applications) to communicate with your 
system’s SNMP agent

Use the Web Management suite of 
applications that is embedded in the 
software

Ethernet port that 
is assigned an IP 
address

Configure System
for Management

8

 


background image

Quick Installation Guide

7

Modem

 — Uses a modem to establish a connection between your 

current Administration Console session and the Console port. When 
you have configured the modem from the Administration Console 
menu system, the Console appears to be directly connected to the 
external modem.

These management access mechanisms are described briefly next and 
more completely in the 

SuperStack II Switch 3900 and Switch 9300 

Implementation Guide

.

In-band Management (Switch 3900 and 9300).

To manage your 

network in band:

1

From the top level of the Administration Console, enter:

ip interface define

2

Enter the IP address of the interface.

3

Enter the subnet mask. Press Return or Enter to accept the default or 
current value.

4

Enter the index number of the VLAN that you want to associate with the 
IP address.

For more information about configuring VLANs, see the 

SuperStack II 

Switch 3900 and Switch 9300 Implementation Guide

.

Out-of-band Management (Switch 9300 only). 

To manage your 

network out of band: 

1

From the top level of the Administration Console, enter:

ip interface define

2

Enter the IP address for the out-of-band port.

3

Enter the subnet mask. Press Return or Enter to accept the default or 
current value.

4

Enter 

system

 as the interface type.

 


background image

8

Quick Installation Guide

This section explains how to identify and correct system problems and 
suggests some things that you can do if you cannot resolve a problem.

Symptom

Possible Sources of Problem and Steps to Take

Power failure 

System does not power up.

Possible sources of problem:

System is not receiving power.

Power supply has malfunctioned.

Recommended actions:

1

Verify that the building’s power outlet has power.

2

Check that the power cord is firmly inserted into 
the system and into the building’s power outlet.

3

If you are using an RPS or UPS, check that it is 
firmly plugged into the building’s power outlet.

4

Try another power cable, RPS, or UPS.

5

If the system still does not operate, remove the 
power cord from the system and contact your 
network supplier or 3Com Technical Support.

LED Status

Possible Sources of Problem and Steps to Take

Power

 LED does not light.

Possible source of problem: 

System failure

Recommended actions: 

1

Shut down the system by removing the power 
cord.

2

Contact your network supplier or 3Com Technical 
Support.

Fault

 LED blinks yellow.

Possible source of problem: 

Diagnostic software is not running.

Recommended actions:

1

Check the Administration Console display for 
diagnostic messages.

2

Contact your network supplier or 3Com Technical 
Support.

Solve
Problems

9

 


background image

Quick Installation Guide

9

LED Status 

Possible Sources of Problem and Steps to Take

Pckt

 LED does not light.

Possible sources of problem: 

Software error has occurred.

Traffic is disabled in the software.

Recommended action: 

Examine the Administration Console display for 
diagnostic messages.

Verify that the port is not disabled by Spanning 
Tree.

Contact your network supplier or 3Com Technical 
Support.

Stat

 LED does not light.

Possible sources of problem: 

System does not recognize a connection to the 
port.

Cabling is not fully attached to the port.

Cabling to the port is faulty.

Recommended actions: 

1

Verify that all cables are firmly inserted into both 
the system’s affected port and the attached 
device. 

2

Test for faulty cables. When the problem is 
corrected, the

 

LED lights green.

3

If the LED does not light, contact your network 
supplier or 3Com Technical Support.

 


background image

10

Quick Installation Guide

Technical Support

If you experience system problems that are not addressed in this guide, 
contact your network supplier or 3Com Technical Support. Before you 
call, gather the following information and have it available:

System type and serial number

Maintenance agreement, or the purchase date and the warranty 
information from the last page of the 

Getting Started Guide

 for your 

system

Release number of installed software

Brief description of the problem

Some of this information can be viewed in the system display in the 
Administration Console. See the 

Command Reference Guide

 for more 

information. 

For information on where to call, see the Technical Support section of the 

Software Installation and Release Notes

 or the 3Com Web site: 

www.3com.com.

For information on how to administer and operate the SuperStack II 
Switch 3900 and Switch 9300, see the 

Command Reference Guide,

 the 

SuperStack II Switch 3900 and Switch 9300 Implementation Guide,

 the 

Web Management User Guide 

on the Documentation CD, and the

 

Software Installation and Release Notes

Administer and
Operate System

10

 


background image

 


background image

http://www.3com.com/

Part Number 10012928 
Published August 1999

3Com Corporation
5400 Bayfront Plaza
Santa Clara, California
95052-8145

Copyright © 1999, 3Com Corporation. All rights reserved. No part of this documentation may be 
reproduced in any form or by any means or used to make any derivative work (such as translation, 
transformation, or adaptation) without written permission from 3Com Corporation. 3Com Corporation 
reserves the right to revise this documentation and to make changes in content from time to time without 
obligation on the part of 3Com Corporation to provide notification of such revision or change.

3Com Corporation provides this documentation without warranty, term, or condition of any kind, either 
implied or expressed, including, but not limited to, the implied warranties, terms, or conditions of 
merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or 
changes in the product(s) and/or the program(s) described in this documentation at any time.

Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may 
not be registered in other countries. 3Com, the 3Com logo, and SuperStack are registered trademarks of 
3Com Corporation.

All other company and product names may be trademarks of the respective companies with which they are 
associated.