PDF User Manual

  1. Home
  2. Manuals
  3. Viessmann VITOGAS 100 Technical Data Manual

Viessmann VITOGAS 100 Technical Data Manual

Made by: Viessmann
Type: Technical Data Manual
Category: Boiler
Pages: 12
Size: 0.29 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

V

V

V

VI

I

I

IT

T

T

TO

O

O

OG

G

G

GA

A

A

AS

S

S

S 1

1

1

10

0

0

00

0

0

0

Cast iron hot water heating boiler

90 to 240 MBH/26 to 70 kW

5167 462 v1.5 02/2011

Vitogas 100 with boiler stand
beside Vitocell-V 100 domestic hot water storage tank

Vitogas 100

Technical Data Manual

Model Nos. and pricing: see Price List

Vitogas 100

GS1 Series – residential, fully assembled boiler

Natural Gas-/Propane-Fired, Single-Stage Boiler

cast iron sectional construction
atmospheric, fully premix burner
Heating input: 90 to 240 MBH

26 to 70 kW

 


background image

Product Information

2

Vitogas 100

Top performance in a small package. Thanks
to its compact dimensions, the Vitogas 100
is ideal for installation in closets and
alcoves. Apart from saving space, the
Vitogas 100 is economical in terms of
energy consumption with reduced
emissions.

The benefits at a glance:

H

High operational reliability and a long
service life

due to special high-grade gray

cast iron with lamellar graphite and a low
thermal load on the heat exchanger surface.

H

Clean combustion

due to atmospheric

premix burner with super-stoichiometric
premixing: NO

x

< 27.9 ppm (air-free),

CO < 9.2 ppm (air-free). The Vitogas 100
therefore meets the toughest emission
requirements in North America, such as
California regulations (SMAQMD).

H

Economical and environmentally friendly
operation via modulating boiler water
temperatures.

Annual fuel utilization efficiency (A.F.U.E.)
of up to 85.6 %.

H

Intermittent pilot ignition system provides
soft, quiet and

extremely reliable ignition.

H

Compact dimensions

– therefore suitable

for installation in a boiler room, a utility
room or even in an open living area.

H

Problem-free transport into
difficult-to-access

boiler rooms due to light

weight and compact design.

Heat exchanger surfaces of special
high-grade gray cast iron for high
operational reliability and a long
service life

5

1

6

7

4

6

2

v

1

.5

 


background image

Product Information

Cross-Section

Product may not be exactly as illustrated.

3

Extremely effective

Heat exchanger surfaces of

Vitotronic – the new

insulation

special high-grade gray cast

generation of boiler controls:

iron with lamellar graphite

Intelligent, easy to install,
operate and service

Stainless steel atmospheric

A redundant gas

super-stoichiometric

valve doubles

premix burners for low-

operational safety

emission combustion

5

1

6

7

4

6

2

v

1

.5

 


background image

Technical Data

4

Technical data

Boiler Model

Model No.

GS1-22

GS1-29

GS1-35

GS1-42

GS1-48

GS1-60

CSA input

MBH
kW

90
26

115

34

145

42

165

48

190

56

240

70

CSA output /
DOE heating capacity

MBH
kW

76
22

98
29

123

36

140

41

161

47

203

60

Net I=B=R rating

*1

MBH
kW

66
19

85
25

107

31

122

36

140

41

177

52

Heat exchanger surface area

ft

2

m

2

16.25

1.51

21.42

1.99

26.48

2.46

31.54

2.93

36.60

3.40

46.82

4.35

Min. gas supply pressure

Natural gas
Liquid propane

“w.c.
“w.c.

5

11

5

11

5

11

5

11

5

11

5

11

Max. gas supply pressure

*2

“w.c.

14

14

14

14

14

14

A.F.U.E.

*3

%

85.6

85.5

85.5

85.5

85.5

85.4

Overall dimensions

*4

Overall length

Overall width

Width

Overall height (operation)

– Height 1 (control unit in

position for operation)

– Height 2 (control unit in

position for servicing)

Height incl. flue pipe elbow

Height of boiler stand

Height of DHW tank
positioned under the boiler
– 42 to 53 USG/

160 to 200 liter capacity

inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm

inches
mm

33¼

844

25½

650

21½

546

33¼

845

37½

955

46½

1180

39

992

250

26

660

33¼

844

25½

650

21½

546

33¼

845

37½

955

46½

1180

39¾

1012

250

26

660

34

864

33

840

29

736

33¼

845

37½

955

46½

1180

39¾

1012

250

26

660

34

864

33

840

29

736

33¼

845

37½

955

46½

1180

39¾

1012

250

26

660

34

864

36½

930

32½

826

33¼

845

37½

955

46½

1180

42½

1082

250

––

34

864

43¾

1110

39½

1006

33¼

845

37½

955

46½

1180

42½

1082

250

––

Weight

, boiler with insulation,

lbs

burner and boiler control unit

kg

273
124

326
148

375
170

428
194

481
218

582
264

Boiler water content

USG
ltr

2.6
9.7

3.1

11.7

3.6

13.8

4.2

15.9

4.7

17.9

5.8

21.9

Max. operating pressure

psig

60

60

60

60

60

60

Number of intermediate
cast iron sections

2

3

4

5

6

8

Number of burners

3

4

5

6

7

9

5

1

6

7

4

6

2

v

1

.5

 


background image

Technical Data

5

Technical data (continued)

Boiler connections

Boiler supply and return
Safety supply
Drain valve

” (male thread)
” (male thread)
” (male thread)


¾


¾


¾


¾


¾


¾

Gas supply connection

” (NPT)

½

½

½

½

½

½

Flue gas

*5

Temperature (gross)

Mass flow rate
– with natural gas

– with liquid propane

°F
°C

lbs/h
kg/h
lbs/h
kg/h

230
110

161

73

148

67

230
110

216

98

209

95

235
113

236
107
209

95

266
130

231
105
223
101

230
110

342
155
322
146

252
122

353
160
337
153

Vent pipe collar

outside Ø”

5

6

6

6

7

7

*1

Net I=B=R rating based on piping and pick-up allowance of 1.15.

*2

If the gas supply pressure is higher than the maximum permissible value, a separate gas regulator must be installed upstream of the
boiler system.

*3

With intermittent pilot electronic ignition system and vent damper.

*4

Height dimensions for Vitogas 100 include leveling bolts.

*5

Measured flue gas temperature after dilution air with combustion air temperature of 68 °F/20 °C.

"

For information regarding other Viessmann System Technology componentry, please reference documentation of the respective product.

5

1

6

7

4

6

2

v

1

.5

 


background image

Technical Data

6

Boiler Stand (Accessory)
Vitocell-H – only those
combinations which are stated
in the Price List are possible.
See Boiler/Tank Compatibility Chart
on following page.

Dimensions

Boiler
Model

GS1

-22

-29

-35

-42

-48

-60

a

b

inches
mm
inches
mm

12¼

313

13¼

337

14¼

359

11½

291

15¾

402

17¼

438

17¾

448

15½

392

19½

494

17¼

436

23

587

20½

523

5

1

6

7

4

6

2

v

1

.5

Legend

BD

Boiler Drain

BWR Boiler Water Return
BWS Boiler Water Supply
DH

Draft Hood

GC

Gas Connection

SS

Safety Supply

Ov

e

ra

ll

h

e

ig

h

t

H

e

ig

h

t

1

H

e

ig

h

t

2

Overall length

H

e

ig

h

t

in

c

l.

fl

u

e

p

ip

e

e

lb

o

w

Width

Overall width

4

8

/

1

2

1

7

m

m

3

8

½

/

9

7

9

m

m

4

2

¼

/

1

0

7

2

m

m

3

3

¼

/

8

4

2

m

m

2

6

/

6

6

0

m

m

5

8

¾

/

1

4

9

3

m

m

9

¾

2

5

0

m

m

2

8

¼

/

7

1

9

m

m

2

2

/

5

5

7

m

m

1

6

¼

/

4

1

2

m

m

1

2

½

/

3

1

9

m

m

7

¼

1

8

2

m

m

3

0

¾

/

7

8

0

m

m

BD

GC

BWR

BWS

SS

DH

6¾” / 173 mm

3” / 78 mm

26” / 663 mm

20” / 510 mm

6¾” / 173 mm

BD

NGC

BWR

BWS

SS

DH

5

4

¼

/

1

3

7

9

m

m

 


background image

Technical Data

7

Boiler/Tank Compatibility

Support bars may be required when
mounting a Vitogas 100, GS1 boiler on a
Viessmann Vitocell-H Series tank.
Refer to the following chart to determine
whether support bars are required for your
application.

Order numbers are listed for boiler/tank
combinations requiring support bars.

Certain boilers (listed with a “

z

” in the

chart) are directly compatible with the
Vitocell-H tank and thus do not require
additional hardware.

Combinations listed with “n.a.” are
incompatible. Do

not

attempt to install these

combinations.

For more information see Viessmann Price
List.

Boiler/Tank Compatibility

Vitocell-H 100

DHW storage tank

Vitocell-H 300

DHW storage tank

Vitogas 100

CHA-160

CHA-200

EHA-160

EHA-200

EHA-350

EHA-450

GS1-22/-29
GS1-35
GS1-42
GS1-48
GS1-60

z
z

n.a.
n.a.
n.a.

z
z
z

n.a.
n.a.

z
z

n.a.
n.a.
n.a.

z
z
z

n.a.
n.a.

n.a.

z
z
z

n.a.

n.a.
n.a.
n.a.

Z001 060

n.a.

Order No. = Support bars are required.

z

=

Support bars are not required. Boiler/tank are directly compatible.

n.a. = Boiler/tank are incompatible. Neither mounting with support bars, nor direct-mounting possible.

Waterside Flow (primary circuit)

Typical Flow Rates

Boiler Model

GS1

-22

-29

-35

-42

-48

-60

20°F rise

30°F rise

GPM
m

3

/h

GPM
m

3

/h

7.5
1.7
5.0
1.1

9.8
2.2
6.5
1.5

12.3

2.8
8.2
1.9

14.0

3.2
9.3
2.1

16.1

3.6

10.7

2.4

24

5.4

16.0

3.6

Use standard friction loss method for pipe sizing.

5

1

6

7

4

6

2

v

1

.5

P

re

s

s

u

re

d

ro

p

Water flow

ltr/h

GPM

w

.c

.

m

b

a

r

16

40

20

50

1.6

4

2.0

5

3.2

8

4

10

8

20

12

30

1.2

3

2

.2

5

0

0

2

.6

6

0

0

3

.5

8

0

0

4

.4

1

0

0

0

9

2

0

0

0

1

3

3

0

0

0

1

8

4

0

0

0

2

2

5

0

0

0

2

6

6

0

0

0

3

5

8

0

0

0

0.8

2

0.4

1

2.4

6

1

.3

3

0

0

1

.8

4

0

0

GS1-22

GS1-29

GS1-35 and -42
GS1-48 and -60

 


background image

Technical Data
Standard Equipment/Boiler Control Alternatives

8

Recommended Minimum Service Clearances

Minimum Clearances to Combustibles

Boiler Model

GS1

-22

-29

-35

-42

-48

-60

Rear (from
draft hood)

inches
mm

6

150

6

150

6

150

6

150

6

150

6

150

Sides

inches
mm

0
0

0
0

0
0

0
0

0
0

0
0

Flue

inches
mm

6

150

6

150

6

150

6

150

6

150

6

150

Top

inches
mm

6

150

6

150

6

150

6

150

6

150

6

150

Floor

Combustible

All clearances are measured from boiler enclosure panel.

Standard Equipment

Note:

Boiler controls and burners are purchased

separately. Please see Price List for details.

Boiler shell with mounted insulating jacket and
atmospheric premix burners for natural gas or
liquid propane conforming to local regulations.
1 carton with boiler installation fittings
1 carton with safety header
1 carton containing either a vent damper or a

power venter (please specify at time of
order).

Carrying handles (accessory) are available to
facilitate transport to the boiler location. See
Price List.

See previous page and/or Price List for
possible boiler/DHW tank combinations.

Boiler Control Alternatives

Vitotronic 100, KK10

standard boiler control for high temperature
heating systems

Vitotronic 100, KW10

standard boiler control for high temperature
heating systems with indoor/outdoor system
control

Vitotronic 100, KW10A / KW10B

standard boiler control for high temperature
heating systems with indoor/outdoor system
control
With or without DHW

Vitotronic 200, KW2

for multiple-temperature heating systems
with or without a mixing valve,
with indoor/outdoor digital boiler and heating
system control

Vitotronic 300, KW3

for multiple-temperature heating systems
with up to two mixing valves,
with indoor/outdoor digital boiler and heating
system control

5

1

6

7

4

6

2

v

1

.5

min.
27½” / 700 mm

min.
9¾”
250 mm

m

in

.

9

¾

2

5

0

m

m

m

in

.

9

¾

2

5

0

m

m

top min.
24” /
600 mm

 


background image

System Design Considerations

9

System Design Considerations

The Vitogas 100 is designed for closed loop,
forced circulation hot water heating systems
only.

Boiler selection

The boiler model size should be based on an
accurate heat loss calculation of the
building. The boiler selected must be
compatible with the connected radiation.

Venting

For proper operation of the Vitogas boiler, all
products of combustion must be safely
vented to the outdoors, while ensuring that
flue gases do not cool prematurely.
It is critical that the chimney system be
properly designed to handle the relatively
cool flue gas temperatures produced by the
Vitogas boiler.
Flue gases which cool too quickly and
produce condensation lead to damages if
the chimney diameter is too large and the
chimney system is not well insulated.
If a calculated chimney diameter lies
between two values, the larger diameter
should be selected.
The Vitogas 100, GS1 boiler is a Category I
boiler as defined in the ANSI Z21.13 CSA
4.9 Standard. Use approved vent material
(such as B-vent) only.

Intermediate section

Use the shortest possible path between the
boiler and the chimney. A maximum of two
elbows may be installed in the intermediate
section. Avoid the use of two level 90°
elbows.
The intermediate section must be sealed gas
tight at the boiler vent pipe collar and at the
chimney connection. Ensure any test port
for combustion values is sealed as well.

The chimney connection between the boiler
vent pipe collar and the chimney must be
installed with insulation. We recommend
consulting a reputable chimney installer for
advice in project-specific circumstances.

Warranty

Our warranty does not cover damages
resulting from the following:
– installation or service by unqualified and

not licensed personnel

– corrosion caused by flue gas condensation

due to low boiler water and/or return
water temperatures

– operation with contaminated fill and

supplementary feed water

For detailed warranty information, please
read warranty sheet supplied with product.

Combustion air supply

The boiler must not be located in areas or
rooms where chemicals containing chlorine,
bromine, fluorine, or other corrosive
chemicals are stored. Examples include
refrigerants, bleach, paint, paint thinner, hair
spray, cleaning solvents, water softener
salt, etc. The combustion air must not be
contaminated with any amount of the above
mentioned chemicals.

Boiler should never be installed in areas
where excessive dust, high humidity, or risk
of frost exist. Ensure adequate ventilation
and supply of fresh combustion air.

Consult Viessmann if uncertainties exist in
regard to a suitable boiler installation
location.

This boiler/burner unit needs clean fresh air
for safe operation and must be installed so
that there are provisions for adequate
combustion and ventilation air.
For gas or propane, use the “Natural Gas
Installation Code CAN/CSA-B149.1 or
B149.2” (Canada), or “National Fuel Gas
Code ANSI Z223.1” (USA), and/or
provisions of local codes.

The sizing methods outlined in the above
codes should be used when installing a
round duct to supply combustion air from
the outside.

System layout

The boiler water temperature limit is factory
set to 167 °F/75 °C.
The boiler water temperature limit can be
increased by altering the adjustable high
limit to increase the supply water
temperature.
To minimize piping losses of the system
however, we recommend that the radiation
and domestic hot water production in the
system be designed for a 158 °F/70 °C
boiler supply water temperature.

Water quality

Treatment for boiler feed water should be
considered in areas of known problems,
such as where a high mineral content and
hardness exist. In areas where freezing
might occur, an antifreeze may be added to
the system water to protect the system.
Please adhere to the specifications given by
the antifreeze manufacturer. Do not use
automotive silicate based antifreeze. Please
observe that an antifreeze/water mixture
may require a backflow preventer within the
automatic water feed and influence
components such as diaphragm expansion
tanks, radiation, etc. A 40% antifreeze
content will provide freeze-up protection to
-10 °F/-23 °C. Do

not

use antifreeze other

than specifically made for hot water heating
systems. System also may contain
components which might be negatively
affected by antifreeze. Check total system
frequently when filled with antifreeze.

Oxygen diffusion barrier
underfloor tubing

The boiler warranty does not cover leaks
resulting from corrosion caused by the use
of underfloor plastic tubing without an
oxygen diffusion barrier. Such systems must
have the non-oxygen diffusion barrier tubing
separated from the boiler with a heat
exchanger. Viessmann recommends the use
of underfloor plastic tubing with an oxygen
diffusion barrier.

Low water cut-off

A low water cut-off may be required by local
codes. If boiler is installed above the
radiation level, a low water cut-off device of
approved type must be installed in all
instances. An approved type low water
cut-off device must be provided by the
heating contractor. Do not install an
isolation valve between the boiler and the
low water cut-off.

5

1

6

7

4

6

2

v

1

.5

 


background image

Installation Examples

10

Installation Examples

These examples depict possible piping layouts
for Viessmann product equipped with
Viessmann System Technology. For boiler and
tank combinations, please install only the
feasible combinations listed in the Price List.

These are simplified conceptual drawings only!
Piping and necessary componentry must be field
verified.

Proper installation and functionality in the field is
the responsibility of the heating contractor.

Without mixing valve

e.g. with Vitotronic 100

The installation of the check valve to restrict
gravity circulation in the heating supply pipe
prevents uncontrolled heat flow to the heating
system by gravity during priority switching of
domestic hot water heating or during summer
operation.

Heating circuit
Spring-loaded flow check valve
Circulation pump
Safety header
with automatic air vent,
pressure relief valve, and
pressure gage
Expansion tank
Domestic hot water storage tank
(indirect-fired)
DHW pump module
Bypass pipe (highly recommended)
c/w two regulating valves (V

1

, V

2

)

See Installation Instructions for details.

5

1

6

7

4

6

2

v

1

.5

IMPORTANT

V

1

V

2

V

1

V

2

 


background image

Installation Examples

11

With 3-way mixing valve to regulate heating circuit

e.g. with Vitotronic 200, KW2 combined with a mixing valve actuator accessory kit

Heating circuit
Spring-loaded flow check valve
Circulation pump
Safety header
with automatic air vent,
pressure relief valve, and
pressure gage
Expansion tank
Domestic hot water storage tank
(indirect-fired)
3-way mixing valve
Bypass pipe (highly recommended)
c/w two regulating valves (V

1

, V

2

)

See Installation Instructions for details.

5

1

6

7

4

6

2

v

1

.5

V

1

V

2

V

1

V

2

 


background image

Viessmann Manufacturing Company Inc.
750 McMurray Road
Waterloo, Ontario

N2V 2G5

Canada

Tel. (519) 885-6300

Fax (519) 885-0887

www.viessmann.ca

mail@viessmann.ca

Viessmann Manufacturing Company (U.S.) Inc.
45 Access Road
Warwick, Rhode Island

02886

USA

Tel. (401) 732-0667

Fax (401) 732-0590

www.viessmann-us.com

mail@viessmann-us.com

Installation Examples

12

With 4-way mixing valve to regulate heating circuit

e.g. with Vitotronic 200, KW2 combined with a mixing valve actuator accessory kit

Heating circuit
Spring-loaded flow check valve
Circulation pump
Safety header
with automatic air vent,
pressure relief valve, and
pressure gage
Expansion tank
4-way mixing valve
Domestic hot water tank
(indirect-fired)
Bypass pipe with flow regulating
valve, for systems with large water
content (>1 USG/13 000 Btu/h / 15
ltr/kW/h of boiler input).
See Installation Instructions for details.

Underfloor heating system with system separation

Underfloor heating circuit
Spring-loaded flow check valve
Circulation pump for underfloor
heating circuit
Safety header
with automatic air vent,
pressure relief valve, and
pressure gage
Expansion tank
3-way mixing valve
Circulation pump for heat exchanger
Heat exchanger
Supply temperature sensor

T

e

c

h

n

ic

a

l

in

fo

rm

a

ti

o

n

s

u

b

je

c

t

to

c

h

a

n

g

e

w

it

h

o

u

t

n

o

ti

c

e

.

P

ri

n

te

d

o

n

e

n

v

ir

o

n

m

e

n

ta

lly

fr

ie

n

d

ly

(r

e

c

y

c

le

d

a

n

d

re

c

y

c

la

b

le

)

p

a

p

e

r.

5

1

6

7

4

6

2

v

1

.5