Electric Boilers 

MINI ULTRA

M

odels from 6 kW  to 12 kW  : 

2 08 / 2 40 V   s in g le   p h a s e    

 

INSTALLATION & OPERATING MANUAL 

  

 

 

 

Your MINI ULTRA Electric Boiler has been carefully assembled and factory tested to provide 
years of trouble-free service.  The following information and safety measures are provided to 
enable proper installation, operation, and maintenance of this product. 
  
It is imperative that all persons who are expected to install, operate or adjust this boiler 
should read these instructions carefully.   
 
Any questions regarding the operation, maintenance, service or warranty of this electric 
boiler should be directed to the supplier.   
 
When all installation steps have been completed, insert this installation manual in its original 
envelope, and keep in a safe place (close to the boiler) for future reference. 

 

THERMO 2000 INC.   

 

 

 

 

 

 

revision: June.2014 

Printed in Canada

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

2.

 

Ratings & Specifications at 120/240** Vac/1ph (3 wires L1-N-L2): 

MINI ULTRA 

Cable*! 

90C 

Breaker!

Model 

Capacity 

KW/BTU at 

240Vac** 

Amps. ! 

Elements at 

240Vac** 

Electric 

Element(s) 

at 240Vac 

 

Stages 

Cu 

Al 

Amp. 

MINI Ultra 6 

6 / 20,470 

25 

2 x 3 KW 

40 

MINI Ultra 7.5 

7.5/25,590 

31 

1X4.5+1X3K 

40 

MINI Ultra 9 

9 / 30,710 

37.5 

2 x 4.5 KW 

50 

MINI Ultra 12 

12 / 40,940 

50 

2 x 6 KW 

70 

 
Add the amperage (Max. 5amp-1/6hp) of the circulating pump if it is connected directly to the boiler 
A higher capacity cable an breaker could be required. In all cases the local Electrical Code has priority. 
** Can be connected to a 208Vac/1ph electrical supply. The resulting capacity will be of 75% of the 

nominal capacity at 240V and the amperage will be of 87%. 

 

Dimensions 

 

Connections 

Overall dimensions 

Inlet/ heating return 

3/4 “ NPT Fem 

Height 

21-1/2 inches 

Outlet/ heating supply 

3/4 “ NPT Fem 

Width 

9 inches 

Pressure relief valve 

3/4 “ NPT Fem 

Depth 

9 inches 

Drain valve 

3/4 “ NPT Fem 

Weight 

40 lbs. 

 

Operating temp. range: 50°F (10C) to 190°F (88C).  Maximum pressure : 30 psi (207kPa) 

 

 

Figure 1.

 

 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

3.

 

 

      General Safety Precautions 

 

Be sure to read and understand the entire Installation & operation manual before attempting to 
install or to operate this water heater.  Pay particular attention to the following General Safety 
Precautions.  Failure to follow these warnings could cause property damage, bodily injury or 
death.  Should you have any problems understanding the instructions in this manual, STOP, 
and get help from a qualified installer or technician.  

 

INTRODUCTION 

 

 

These important safeguards and instruction 
appearing in this manual are not meant to 
cover all possible conditions and situations 
that may occur.  It should be understood that 
common sense, caution and care are factors 
which cannot be built into every product.  
These factors must be supplied by the 
person(s) caring for and operating the unit. 

 
LOCAL INSTALLATION REGULATIONS 

This  electric  boiler  must  be  installed  in 
accordance  with  these  instructions  and  in 
conformity with local codes, or in the absence of 
local  codes,  with  the  National  Plumbing  Code 
and  the  National  Electric  Code,  current  edition.  
In  any  case  where  instructions  in  this  manual 
differ  from  local  or  national  codes,  the  local  or 
national codes take precedence. 
 

SECURITY CONSIDERATIONS 

All  installations  have  a  maximum  design 
operating pressure limited to 30 psi (207kPa) by 
a safety relief valve.   
 
Boiler  operating  temperature  range  is  from 
50

0

F(10C)  and  190°F(88C).    This  boiler  is 

designed  to  be  used  only  in  a  hot  water  close 
circuit heating system. 
A  mix  of  water  and  propylene-glycol  antifreeze 
specially  formulated  for  heating  system  can  be 
used up to a maximum concentration of 50%. 
 

 
 
 
 

 
CHECK LIST

  

Please check the identification tag on the unit to 
make sure you have the right model. 
 

 

List of components shipped with the unit : 

 

Pressure relief valve set at 30 PSI. 

 

Drain valve. 

 

Temperature & pressure indicator 
(Factory installed). 

 

Outdoor temperature sensor 

 

 

SHIPMENT INSPECTION 

Inspect the electric boiler for possible shipping 
damage.  The manufacturer’s responsibility 
ceases upon delivery of goods to the carrier in 
good condition.  Consignee must file any claims 
for damage, shortage in shipments, or non-
delivery immediately against carrier. 

 

WARNING 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

4.

 

INSTALLATION 

 
 
The manufacturer’s warranty does not cover any damage or defect caused by installation, or 
attachment, or use of any special attachment other than those authorized by the manufacturer 
into, onto, or in conjunction with the water heater.  The use of such unauthorized devices may 
shorten the life of the boiler and may endanger life and property.  The manufacturer disclaims any 
responsibility for such loss or injury resulting from the use of such unauthorized devices 

 

LOCATION 

The electric boiler should be installed in a clean, 
dry  location.    Long  hot  water  lines  should  be 
insulated  to  conserve  water  and  energy.    The 
electric  boiler  and  water  lines  should  be 
protected 

from 

exposure 

to 

freezing 

temperature. 
The  electric  boiler  must  be  located  or  protected 
so  as  not  to  be  subject  to  physical  damage,  for 
example, by moving vehicles, area flooding, etc.  

 

 
The  electric  boiler  should  not  be  located  in 
an  area  where  leakage  of  the  tank  or  water 
connections  will  result  in  damage  to  the 
adjacent  area  or  to  lower  floors  of  the 
structure.    When  such  areas  cannot  be 
avoided,  a  suitable  drain  pan  or  non-
flammable  catch  pan,  adequately  drained, 
and  must  be  installed  under  the  boiler.   
The pan must be connected to a drain. 
NOTE:  Auxiliary catch  pan MUST conform to 
local codes. 

 

 
The  boiler  can  be  mounted  directly  on  a  wall 
with  adequate  screws.  It  needs  to  be  properly 
leveled. 
All models in alcoves. The  ambient temperature 
must not exceed 90F (32C) 
The electric boiler should not be located near an 
air vent blowing  a corrosive  atmosphere or high 
humidity.  The limited warranty is void when the 
failure of  the  electric boiler  is due to a corrosive 
atmosphere.

 

The choice of the mounting position of the boiler 
shall  be  made  in  relation  with  the  required 
clearances  shown  below  and  the  fact  that  the 
electric  element  compartment  of  the  boiler 
needs clearance to allow their replacement. 
°

CLEARANCE  

 

For  adequate  inspection  and  servicing  the 
following minimum clearance is necessary: 

Sides 

4 in. /10cm 

 Electric elements side  

14 in./35cm 

Front side of the boiler 

24 in./60cm 

Back  

0 in./0cm 

 

 

Fig. 2 Mounting position

CAUTION 

WARNING 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

5.

 

 

BOILER WATER CONNECTIONS   

Make sure you connect the accessories and the piping to the proper connection fittings as indicated at figure 
2 above and according to the selected mounting position. 
Figure 3 below shows typical connections of a MINI boiler to a radiant floor heating system. The location of 
the distribution system components may be different from what is represented. 

 

Figure 3 : Typical piping lay-out 

 

Flow check valve 

On heating systems having more than one pump, 
each  pump  will  need  to  be  equipped  with  a  flow 
check  valve  either  incorporated  into  the  pump  or 
separate. 

 
Pressure relief valve 

This  component  supplied  with  the  unit  must  be 
installed  directly  to  the  boiler  housing  to  the 
appropriate connection according to the mounting 
position.   
Connect the outlet of the relief valve downward to 
a safe location in case of discharge. 
The piping diameter used for the discharge piping 
shall not be smaller than that of the valve outlet.  .  
No  valve  of  any  type,  restriction  or  reducer 
coupling should be installed on the discharge line.  
Local  codes  shall  govern  the  installation  of  relief 
valves. 

 

Expansion tank

 

The  expansion  tank  must  be  able  to  store  the 
required  volume  of  boiler  water  during  maximum 
design  operating  temperature.  The  maximum 
allowable  operating  pressure  is  30PSI  (207kPa). 
Contact 

your 

plumbing 

supply 

house 

for 

assistance. 

 
Water pressure feeder regulator 

When  a  pressurized  water  supply  is  available  in 
the  building,  a  make-up  systems  consisting  in  a 
water  pressure  reducer  generally  set  at  12psi 
(83kPa) and equipped  with check  valve  satisfying 
local  regulations  must  be  installed  between  the 
boiler and the water supply system.  
If the boiler is installed  in a building that does not 
have a water supply and when the local plumbing 
codes  allows,  it  is  possible  to  simply  manually 
pressurized  the  heating  system  equipped  with  an 
expansion tank to 10 (7kPa)to 28psi (193kPa) and 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

6.

 

manually  maintain  a  minimum  pressure  when 
required.  Another  possibility  is  to  install  a 
pressurized storage tank specially made for those 
applications  that  will  inject  on  request  an 
appropriate  quantity  of  liquid  to  maintain  an 
appropriate pressure on the heating system. 
 

Air bleeder   

Installation  of  manual  or  automatic  air  vents  are 
required to eliminate all air from the boiler and the 
heating distribution system.  
When  the  boiler  is  installed  above  the  heating 
distribution 

system, 

an 

automatic 

air 

separator/eliminator  must  absolutely  be  installed 
at  the  outlet  of  the  boiler  in  order  to  eliminate  all 
possibilities  of  air  buildup  inside  the  boiler  that 
would damage the heating elements. 
 

Circulating pump 

We  recommend  that  the  pump  be  installed  at  the 
outlet  of  the  boiler  with  isolating  valves  as  shown 
in figure 3. 
The pump shall be selected such as to be able to 
supply  adequate  flow  in  relation  to  the  heating 
distribution  system  on  which  it  will  be  connected 
and the heating capacity of the boiler installed. 
The  table  below  will  give  you  details  on  required 
water  flow  for  distribution  systems  having  to 
operate with a differential temperature of 10F and 
20F between their inlet and outlet

Model

Diff. 10F (usgpm) Diff. 20F (usgpm) Boilerpress.drop 

MINI Ultra 6

4.0

2.0

Negligible

MINI Ultra 7.5

5.1

2.5

Negligible

MINI Ultra 9

6.0

3.0

Negligible

MINI Ultra 12

8.2

4.1

Negligible

The boiler has to be activated only upon a call for 
heat and when a pump will be working (no jumper 
allowed on TT terminals) a minimum water flow of 
1usgpm is recommended. 
Your  heating  wholesaler shall  be in good position 
to  recommend  the  appropriate  model  for  your 
application. 
The  amperage  drawn  by  the  pump  and  other 
120volts  components  shall  not  exceed  5  amps  or 
1/6HP. 
 

Drain valve 

Installed  at  the  lowest  point  of  the  unit,  it  allows 
the  unit  to  be  drained  for  the  eventual 
replacement of a defective component. 

 
Strainer 

This  component  is  used  to  collect  potential 
sediments  coming  from  the  distribution  system 
and more particularly from systems made of steel 
piping 

and 

radiators. 

If 

such 

sediments 

accumulate at the bottom of the boiler it could be 
harmful  to  the  heat  transfer  of  the  elements  and 
generate premature failures.  
 

 
ELECTRICAL CONNECTIONS: 

 
Main boiler supply 

Wiring  must  conform  to  the  National  Electrical 
Code and to state or local code requirements. 
The electric boiler must be electrically grounded in 
accordance with local codes, or, in the absence of 
local codes, with the National Electrical Code. 
Wiring  must  come  from  a  120/240  Volt  (single 
phase,  60  Hz)  “L1-L2-N”  circuit  protected  by  a 
properly sized breaker. 
Wire  gage  (3  wires+ground)  must  be  properly 
sized.  Consult the boiler rating plate to select the 
proper breaker and wire gage. 
The main terminal block of the boiler is suitable for 
#14 to #2 wires. 
Supply  cables  can  be  made  of  Aluminum  or 
Copper and be rated for 90C (194F). 
If  aluminum  cables  are  used,  it  shall  be  of  an 
adequate  size  (generally  bigger)  to  meet  the 
National electrical code. 

 

Electrical supply of External accessories 

The  total  120vac  consumption  of  the  boiler  and 
external accessories must not exceed 5A. 
The  maximum  electrical  consumption  of  24vac 
external  accessories  connected  to  R&C  terminals 
must  not  exceed  30Va.  The  available  voltage  at 
the boiler transformer must not drop below 24Vac. 

 
Outdoor temperature sensor 

If  you  want  the  target  boiler  temperature  to 
modulate  according  to  the  outdoor  temperature  ( 
when the outdoor  temp.  will  get colder, the target 
temp.  will  get  higher)  ,  the  supplied  outdoor 
sensor will have to be connected to S1 S1 before 
turning the power on to the unit.  
The installation of this sensor avoids the operation 
of  the  boiler  when  the  outdoor  temperature 
exceeds  the  selected  value  corresponding  to  the 
maximum temperature required for heating. 
The sensor shall be connected to terminals S1-S1 
in the boiler using a two conductor cable 18ga. 

 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

7.

 

Thermostat(s) and pump(s) connections: 

 
Thermostats: 
Use a low voltage 24Vac thermostat designed for 
central  heating  (not  electric  baseboards).  Some 
thermostats  are  equipped  with  floor  temperature 
sensor. 
The  purpose  of  the  thermostat  is  to  transmit  an 
heat  demand  to  the  boiler.  When  this  demand  is 
received,  the  boiler  will  control  the  activation  of 
the heating elements. 

 

Heating  systems  equipped  with  one 

thermostat and one pump: 

With  an  18  gauge  cable,  connect  the  room 
thermostat as follow: 
Thermostat with 2 wires: Connect the two wires to 
the R & W boiler terminals. 
Thermostat  with  3  wires:  Connect  the  C/R/W 
wires  from  the  thermostat  to  corresponding 
terminals on the boiler 
Using  14  gauge  wires,  connect  the  circulating 
pump directly to terminals “P and “P” (120vac). 
N.B.  The amperage  drawn by the pump must not 
exceed 5A-1/6HP. 
 

 

Multiple pumps zoning applications: 

Components  shall  be  connected  in  such  a  way 
that when a thermostat is calling for heat, only the 
corresponding pump be operated and an auxiliary 
contact  X-X  closes  to  give  the  signal  of  the  heat 
demand  to  the  boiler  otherwise  the  elements  will 
not be working.  
To do so, you will need relays as illustrated below. 
Boiler terminals PP- will not be used. 
N.B.  Do  not  install  a  jumper  between  terminals  R 
W of the boiler. 

Fig.4: Multiple pumps electrical diagram. 

Zoning with motorized valves

 : 

Connect  the  low  voltage  thermostat  to  the  zone 
valve.  Components  must  be  wired  to  ensure  that 
only  the  zone  valve  corresponding  to  the  zone 
calling for heat is actuated. When a zone valve  
opens,  it  generally  closes  a  switch  that  is 
incorporated in  it. Connect  each switch to the  “R” 
& “W” terminals in the boiler. 
Connect  the  circulator  to  terminals  “P”  and  “P”  in 
the  boiler.(max.  5A-1/6hp)  .  The  electrical 
connections of the motorized zone valves shall be 
made 

according 

to 

the 

manufacturer’s 

instructions.  

Fig. 5 Zone valves electrical diagram. 
 

R W 

R W 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

8.

 

 

 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

9.

 

ADJUSTMENTS OF THE CONTROL MODULE  

 

INTRODUCTION 

The MINI Ultra boiler is mainly designed to be 
installed on closed circuit applications where the 
water of the heating system flows directly from the 
boiler to the heating distribution system  (Standard 
parallel Piping system) 

Two operation modes are then offered: 

 

Fixed boiler temperature set point (the 

outdoor sensor shall not be installed) 

  

 

Outdoor reset  

 

DISPLAYED INFORMATION 

The electronic control uses an LCD display to 
make all adjustments and to visualize the 
operation of the system.

 

 

OPERATION OF THE INTERFACE 

The  controller  uses  four  push  buttons  at  the 
bottom  of  the  display  to  select  and  adjust  the 
parameters. 
The  button 

is  used  to  access  to  the 

configuration menu and confirm a selection. 

The 

buttons  are  used  to 

select an item or adjust a value.  
The 

button  enables  the  illumination  of  the 

display under two different modes.  
The  default  mode  will  enable  the  illumination  of 
the  display  for  a  period  of  10  sec.  each  time  a 

button  is  pressed.  If  the 

is  pushed,  the  light 

will  be  continuously  illuminated.  Just  press  the 
button to change the mode of activation. 

 

 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

10.

 

OPERATION 

IN 

“FIXED 

BOILER 

TEMPERATURE SET POINT”

  

For 

installation 

where 

the 

boiler 

target 

temperature  shall  be  maintained  at  a  fixed 
temperature  that  will  not  vary  in  relation  to  the 
outdoor temperature, the sequence of operation 
will be as follow: 
On a call for heat from the room thermostat, the 
circulating  pump  will  start  and  the  boiler  will 
activate the  number of  stages required to get to 
and maintain the outlet temperature of the boiler 
near  the  selected  target  temperature.  A  rotation 
of  the  stages  based  on  an  equal  time  period  of 
operation is provided. 
N.B.  The  supplied  outdoor  temperature  sensor 
shall  not  be  connected  before  applying  the 
electrical power to the unit 
 
OPERATION WITH “OUTDOOR RESET”: 
For 

installation 

where 

the 

boiler 

target 

temperature  shall  modulate  in  relation  to  the 
outdoor 

temperature; 

when 

the 

outdoor 

temperature  gets  colder,  the  boiler  target 
temperature will increase. 
On  a  call  from  the  room  thermostat,  the 
circulating  pump  will  start  and  the  boiler  will 
activate the  number of  stages required to get to 
and  maintain  the  outlet  boiler  temperature  near 
the  target  temperature  established  by  the 
controller  according  to  the  outdoor  temperature. 
A rotation of the stages based on  an equal time 
period of operation is provided.  
N.B.  The  supplied  outdoor  temperature  sensor 
must be connected before applying the electrical 
power to the unit. 
 
The  boiler  target  temperature  will  be  calculated 
by  the  controller  in  relation  to  the  parameters 
selected 

in 

the 

menu 

and 

the 

maximum  target  temperature  required  when  the 
outdoor temperature will get to -10F (-23C). The 
“STD”  curve  corresponds  to  the  default 
maximum  temperature  for  a  typical  system  and 
this  value  can  be  modified  from  the  “MIN”  to 
“MAX” value shown on the following tables. 
 
 
The following tables show the values of the 
target temperature that will be obtained in 
relation to the outdoor temperature. 

80F
27C

70F

21C

60F
15C

50F
10C

10F

-12C

40F

4C

30F

0C

20F
-7C

0F

-17C

-10F
-23C

-20F

-29C

70F/21C

80F/27C

100F/-38C

90F/32C

110F/43C

120F/49C

130F/54C

Température ext.  / Outdoor temperature 

T

e

m

p

. d

e

 c

o

n

s

ig

n

e

 / 

T

a

rg

e

t t

e

m

p

STD

MAX

MIN

PLANCHER CHAUFFANT DANS BÉTON

RADIANT FLOOR IN CONCRETE

80F
27C

70F

21C

60F
15C

50F
10C

10F

-12C

40F

4C

30F

0C

20F
-7C

0F

-17C

-10F
-23C

-20F

-29C

100F/-38C

90F/32C

110F/43C

120F/49C

130F/54C

Température ext.  / Outdoor temperature 

T

e

m

p

. d

e

 c

o

n

s

ig

n

e

 / 

T

a

rg

e

t t

e

m

p

STD

MAX

MIN

PLANCHER CHAUFFANT ENTRE SOLIVES

RADIANT FLOOR BETWEEN JOISTS

140F/60C

80F/27C

80F
27C

70F

21C

60F
15C

50F
10C

10F

-12C

40F

4C

30F

0C

20F
-7C

0F

-17C

-10F
-23C

-20F

-29C

100F/-38C

90F/32C

110F/43C

120F/49C

130F/54C

Température ext.  / Outdoor temperature 

T

e

m

p

. d

e

 c

o

n

s

ig

n

e

 / 

T

a

rg

e

t t

e

m

p

STD

MAX

MIN

RADIATEURS EN FONTE

CAST IRON RADIATORS

140F/60C

150F/65C

160F/71C

170F/77C

 

T

e

m

p

. d

e

 c

o

n

s

ig

n

e

 / 

T

a

rg

e

t t

e

m

p

 

PURGE DELAY OF THE PUMP 

The controller offers the possibility to 
stop  the  operation  of  the  pump  after  an 
adjustable  delay  once  the  heat  demand  has 
been completed. 
The following choices are offered: 
-“OFF” The pump will stop immediately when the 
heat demand has been satisfied. This selection 
shall be selected on systems equipped with 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

11.

 

motorised fast closing time zone valves with in 
order to prevent noise from water hammering. 
-“15 sec to 60min”  delay where the pump will be 
kept running to enable the pump to circulate 
water into the system to equilibrate the heat in 
all the building. 
-“ON” The pump is in continuous operation. 
Required on particular heating distribution 
systems. 
 

AUTOMATIC HEATING SHUT DOWN  

When  the  outdoor  sensor  is  installed  and  that 
the  unit  then  operates  in  the  “outdoor  reset” 
mode,  the  controller  offers  the  user  the 
possibility  to  automatically  stop  the  boiler  when 
the  outdoor  temperature  reaches  an  adjustable 
value 

(0F 

(-17C) 

à 

105F 

(40C). 

This 

characteristic  is  especially  interesting  on  the 
following applications: 
-Heating 

systems 

equipped 

with 

many 

thermostats where the user wants to prevent the 
operation  of  the  unit  if  one  of  the  thermostats 
has inadvertently been activated  
-Heating systems where the owner supplies heat 
to a lodger 
-Systems connected to a geothermic heat pump 
where  we  do  not  want  the  electric  boiler  to  be 

operating  unless  the  outdoor  temperature  drops 
to a selected degree. 

CONFIGURATION OF THE CONTROLLER 

Since each type of heating distribution system is 
designed  to  operate  at  water  temperatures  that 
are  particular  to  its  operation,  the  proper 
configuration of the operating parameters of this 
particular  system  is  important  to  maximize  its 
performance. 
In  order  to  do  this,  the  installer  will  access  the 
configuration  menu  by  pressing  the 
button  for  2  sec.  until  the  first  menu  appears. 
The  selection  of  the  item  or  value  is  made  by 
pressing  the 

button  and  by 

pressing  the 

button  to  get  to  the  next 

menu.  See  table  1  below  to  visualize  the  menu 
list that will gradually be displayed. 
 
If  the  buttons  remain  untouched  for  a  period  of 
10  sec.,  the  controller  will  register  the  value  of 
the  selection  made  and  return  to  the  regular 
display  position.  It  will  also  return  to  the  regular 
display  after  reviewing  all  the  operating 
parameters of the controller. 
 
In case of a power failure, the parameters will be 
restored  as  they  were  established  before  the 
failure. 

 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

12.

 

 
Table 1:  

ITEM 

DESCRIPTION 

RANGE 

DEFAULT 

 

  

 

Choose the units the user prefers to work with 

F

0

 or C

0

 

F

0

 

 

  

 

Select the type of heating system on which the 
boiler will be installed. 

-Radiant Floor in concrete  

 

-Radiant Floor between 

joists 

 
                            

-Cast iron radiator                    

 
 
 

Hot water baseboards 

 
 
 

 

 

  

 

Adjust the maximum boiler target temperature 
required to adequately heat the building when 
the outdoor temperature is very cold. 

-Radiant Floor in concrete 

  85à 105F                                                

-Radiant Floor between 

joists 110Fà140F                           

-Cast iron radiator 135F à 

165F  

-Baseboard  

160F à 185F 

 

 

100F  

        
                                        

125F 

                           

150F 

                      

175F 

 
 

 

  

 

Select the purge period that the pump will be 
running once the heat demand is completed. 
Select OFF if the heat system is equipped with 
electric zone valves. 

OFF  

15 sec. to 60min.  

ON 

30sec 

 
 

Select the outdoor temperature at which no 
heating of the building is required (the outdoor 
sensor has to be installed) 

0F à 105F 

75F 

 

Note1: Once these parameters have been set, the controller will automatically return to its normal view 
but the user has the possibility to change the target temperature without having to go through the 
complete menus

 
 
Adjustments of the target temperature by 
the user: 

By  pressing  the 

the  end 

user has the possibility to offset the programmed 

target  temperature  without  going  through  the 
tool menus. 
When  the  +  or-  button  is  pressed,  the  value  “0” 
will  appear  and  blink  to  show  a  “0”  offset  value 
from  the  original  settings.  When  the  +  or- 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

13.

 

buttons  are  pressed  again  the  offset  value  will 
change  up  to  a  value  of  +  -10F(5C)  from  the 
original  setting  made  in  the  configuration  menu. 
The  new  value  will  blink  during  5  sec.  and  the 
display  will  then  go  back  to  the  standard  view 
and the new target temperature will be shown.  

Afterward,  when  the 
button  will  be  pressed,  it  will  show  the  value  of 
the  offset  made  previously  and  can  be  re-
adjusted. 

 

Boost system operation  

The  controller  incorporates  a  unique  feature  that 
enables the target boiler temperature to automatically 
be  increased  when  the  building  heat  load  increases 
but  cannot  be  fulfilled  with  the  actual  boiler  target 
temperature and consequently the room thermostat(s) 
cannot be satisfied within a pre-determined period. 
 
Example: 
-Return to normal heat load after low demand periods 
occurring during sunny days. 
-Long  periods  without  heating  which  needs  higher 
boiler temp. to recuperate. 
-Return 

to 

normal 

room 

temperature 

after 

thermostat’s “nights set back” program 

80F
27C

70F
21C

60F
15C

50F

10C

10F

-12C

40F

4C

30F

0C

20F

-7C

0F

-17C

-10F
-23C

-20F
-29C

70F/21C

80F/27C

100F/-38C

90F/32C

110F/43C

120F/49C

130F/54C

Température ext.  / Outdoor temperature 

T

e

m

p

d

e

 co

n

si

g

n

e

 /

 T

a

rg

e

te

m

p

NOR

MAL

BOO

ST

HAUSSE AUTOMATIQUE DU POINT DE CONSIGNE 

« BOOST »

AUTOMATIC INCREASE OF TARGET TEMPERATURE

 

The  controller  will  engage  the  “Boost”  program 
when  the  heat  demand  on  terminals  W&R  has 
been  maintained  for  a  pre-determined  period 
according  to  the  type  of  selected  application. 
Once this  period  has been  reached, the “Boost” 

icon  will  appear  on the  display and the boiler 

target  temperature  will  start  increasing  very 
slowly over a pre-determined period and up to a 
pre-calculated  maximum  value  until  the  heat 
demand  applied  on  W&R  terminals  has  been 
completed. 
On  a  new  heat  demand,  the  previous  boost 
period  is  forgotten  and  the  boiler  target  gets 
back to its original setting  
If  the  system  is  in  “boost”  most  of  the  time,  this 
means 

that  the 

boiler 

target  parameter 

established during “Setting procedure” would  be 
too low for the heating system on which the unit 
is  applied.  This  boiler  target  could  simply  be 
gradually  increased  by  pressing  the  +  button  or 
by re-setting the operating parameters using the 
tool menus. 
N.B. The boost program is  a  marvellous feature 
that  works  fine  on  applications  where  the 
number of room thermostats is in limited quantity 
otherwise  it  may  happen  that  during  very  cold 
periods  the  heat  demand  from  all  the 
thermostats may not become satisfied.  
If  your  application  needs  the  boost  program  to 
be  cancelled,  you  can  do  it  by  pressing    the 
button 

for 6 sec. and the display will show 

icon and the two options ON or OFF will blink 

and  can  be  selected  using  the  +  -  button.  The 
controller  will  register  the  selected  option  and 
return to normal operation if the buttons remains 
untouched  for  5  sec.  or  if  the 

button  is 

pressed. 
 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June.2014)

,                                                                                     Page 

14.

 

 

START UP OPERATION 

 

 
 

Before operating this boiler, be sure to read and follow these instructions, as well as the warnings 
printed in this manual.  Failure to do so can result in unsafe operation of the boiler resulting in 
property damage, bodily injury, or death.  Should you have any problems reading, following or 
difficulty in understanding the instructions in this manual, STOP, and get help from a qualified 
person. 
Do not turn on the boiler unless it is filled with water.  Do not turn on the boiler if the cold water 
supply shut-off valve is closed. 

 

Preparatory step 

 

Make  sure  that  all  the  piping  and 
electrical connections have been made.

 

 

Fill  the  boiler  and  the  heating  system 
with water.

 

 

Check for leaks.

 

 

Check  the  pressure  reading  at  the 
temperature  and  pressure  indicator.  It 
should be around 12psi.

 

 

Turn  On  the  electrical  supply  to  the 
boiler  with  no  heat  demand  from  the 
thermostat(s).

 

 

Completely eliminate all the air from the 
boiler and the distribution piping system. 
To  do  so,  activate  the  circulating  pump 
without  the  heating  elements.  If  the 
pump  is  connected  directly  on  PP 
terminals  of  the  boiler,  it  can  be 
activated  by  selecting  “ON”  in  the 
configuration 

menu 

 

after 

having 

pressed 

for 2 seconds.

 

 

Adjust the UltraSmart boiler temperature 
controller  as  explained  earlier  and  set 
the purge delay of the pump from On to 
its normal operation setting.

 

 

Set the room thermostat ON to generate 
a  heat  demand.  The  pump  shall  start. 
The  heating  elements  shall  gradually 
come on  and the  boiler temperature  will 
increase.

 

 
Start up & Inspection 

 

Measure  the  amperage  value  drawn  by 
the  unit.  It  shall  be  around  the  value 
indicated on the boiler name plate. 

 

Partially  close  the isolating valve at the 
outlet  of  the  boiler  to  reduce  the  water 
flow  and  consequently  slowly  increase 
the  outlet  temperature.  The  heating 
elements  shall  gradually  stop  as  the 
temperature  increases  and  gets  near 
the target temperature.  

 

Lower  the  adjustment  of  the  room 
thermostat(s),  the  heating  elements 
shall  stop  and the pump shall  stop after 
the delay set on the controller. 

 

Check  the  pressure  reading  on  the 
gauge of the unit. It should not be higher 
than 28 psi when the distribution system 
will  get  to  its  maximum  operating 
temperature. 

 
N.B.  On  initial  start  up  it  may  take  a 
considerable  amount  of  time  before  the  water 
reaches the target temperature  
Further  adjustments  may  be  necessary  as  you 
use your boiler and the space heating system. 
 

 
 

SAFETY PRECAUTIONS 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June 2014)

,                                                                                                     Page 

15

 

 

 

MAINTENANCE 

INTRODUCTION 
 

Properly maintained, your boiler will provide years of dependable, trouble free service.  It is recommended that a regular 
routine maintenance program be established and followed by the user.  Components are subject to eventual failure that 
requires service.  Failure to use the correct procedures or parts in these circumstances may make the unit unsafe or 
reduce the life of the boiler.   
 
 
The owner should have the following inspection and 
maintenance procedures performed: 
 

At all time

  

An immediate inspection shall be made if: 
 

 

An odor of melted plastic or overheated 
material is detected  

 

A leak coming from the unit or the heating 
system is observed 

If a leak is detected at the outlet of the safety relief 
valve, it could be related to a problem with components 
installed on your heating distribution system. A quick 
correction is then required.  
Do not plug the outlet of this valve if a dripping condition 
occurs. 

 

Twice a year: 

 

Check for the proper operation of the automatic 
air purger(s) and eliminate air from the 

 

radiators.

 

 
Annually: 

 

It is recommended that a visual inspection be 
made on the electrical compartments of the 
boiler to check the water tightness of the gasket 
on the element flange and also check for any 
signs of overheating of the components and 
wires. Required corrections should be made as 
soon as possible.

 

Parts used for replacement should be the same 
as the original equipment. 

 
 
 
 
Make sure that the power on the unit has been 
turned off before opening the electrical 
compartments of the boiler. 
 

 

Close isolating valves and clean the strainer 
located on the heating return piping. 

 

Open the boiler drain valve to eliminate 
deposits that could have settled at the bottom of 

the boiler. Stop when water gets clear. If there 
is no flow or a very small flow, it could be due to 
a large accumulation of deposits at the bottom 
of the unit. If so, close the isolating valves at the 
inlet and outlet of the boiler, remove heating 
element(s) and clean the inside of the tank with 
a strong jet of water 

WARNING 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June 2014)

,                                                                                                     Page 

16

 

 

REPAIR PARTS  

MINI ULTRA 

                                             

 

 

**When replacing a heating element, make sure to install it in the same orientation it was 
installed at the factory. 

TROUBLE SHOOTING 

PROBLEM 

CAUSES 

SOLUTION 

The display shows 

---

 in “TARGET 

TEMP” 

-There is no heating demand  
-When the outdoor sensor           
is used and the icon is        
shown, the outside temperature 
is above the boiler shut down 
setting. 
-The switch located on the back 
of the controller is set to “Bi-

Energ” and the icon 

is 

shown. 

-Generate a heat demand 
-Temporarily increase the value of this 
setting on the controller configuration. 
 
 
-Set the switch to “Elect” 

The display shows 

“Er1”

 and the 

icon 

is displayed. 

The controller is not detecting the 
presence of the outdoor sensor.  

-Make sure that the sensor cable 
connected to the unit is not in short or 
open circuit. Do not install a jumper 
between S1-S1 when the sensor is 
not required. 
-Check the resistance value (ohms) of 
the sensor. It should correspond to the 
value shown on the table below 
otherwise it should be replaced. 
Check for proper connection of the 
wires inside the boiler connected to 
S1S1 and at the controller terminals. 
 

The display shows “Er2” and blinks 

The controller is not detecting the 
presence of the boiler 
temperature sensor. 

-Check the state of the sensor located 
in the immersion well located at the 
top of the elect. element compartment. 

Heating elements

**

 

3kW : ZEL300-240V3KW 
4.5kW : ZEL300-240V45KW 
6kW : ZEL300-240V6KW 

Temperature & Pressure 
indicator 
ZMC300-75P160C 

Transformer 
ZEL400-120V50VA 

Fuse 
ZEL250-TDCC15A 

Power relays 24VAC 
ZEL100-24ACNO30 

High limit control 
ZEL200-L6C732 

Pressure relief valve 
ZMC200-SV30PSI1 

Control multi-pin connector 

Controller 

 

ZEL100-ULTRA 

Contacteur 2 pôles 
(6,7.5,9kW) 
ZEL100-2PC50120 
Contacteur 4 pôles (12kW) 
ZEL100-4P50A120 

 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June 2014)

,                                                                                                     Page 

17

 

 

--Check the resistance value (ohms) 
of the sensor. It should correspond to 
the value shown on the table below 
otherwise it should be replaced. 

Stage 2 is ON but not Stage 1 

There is no problem. A rotation 
of the stages is provided to allow 
an equal time of operation of the 
stages 

 

The boiler target temperature does 
not change when the outdoor 
temperature varies 

The outdoor sensor has not been 
detected  when  the  power  has 
been applied to the unit. 

Check the connection of the outdoor 
sensor to terminals S1S1. Turn OFF 
the power to the unit for 5 sec. and set 
it back ON. 

The boiler water temperature at the 
outlet of the unit “BOILER T

0

”does 

not get to the “BOILER TARGET T

0”

  

-The  room  thermostat  is  not  in 
constant demand. 
-Some  heating  elements  are 
defective 
-The total capacity of the boiler is 
expelled 

to 

the 

heating 

distribution 

system 

at 

this 

temperature. 

-Adjust the thermostat anticipator (If 
available) to obtain longer operating 
cycles 
-Replace defective elements 
-If a boiler water temperature higher is 
required  to  satisfy  the  heat  demands 
of  the  thermostats,  a  boiler  having  a 
larger capacity is required. 

Boiler stays in demand even when 
the thermostat is not in demand. 
(Systems with more than one 
thermostat) 
 

-On systems with electric zone 
valves, one or many end 
switches included in the valve is 
defective. 
-A jumper has been installed on 
terminals W&R of the boiler 

-Change defective end switch. 
 
 
 
-Make appropriate connections as 
shown in fig.5 

An overheated plastic odour  is 
released from the boiler 
 
 

Turn the power OFF to the boiler. 
Open the front and left side panel 
of the boiler. Check the 
components and electric wires 
for indications of overheating. 

Replace overheated components and 
check supply voltage to the boiler. 

Boiler safety valve is leaking 

-Pressure reading at the indicator 
shows a pressure above 28psi 
 
 
-Pressure is below 28psi 

-The pressure regulator on the 
distribution system is defective or the 
expansion tank is too small or 
defective. 
-Replace the safety valve 

 
 

 

  
Table 2: Sensors resistance value vs real temperature. 

 


background image

 

BTH Electric Boilers USE & CARE MANUAL 

(Revision June 2014)

,                                                                                                     Page 

18

 

 

 

MINI ULTRA

 

 

LIMITED  WARRANTY 

Warranty Coverage for Residential Installation. 

Thermo 2000 Inc. hereby warrants to the original residential purchaser that the MINI 
ULTRA tank installed in a residential setting shall be free of leaks during normal use 
and service for a period of fifteen (15) years from the date of purchase as long as 
the original residential purchaser owns the home in which the unit was originally 
installed. Residential setting shall mean usage in a single-family dwelling in which 
the consumer resides on a permanent basis. Also, residential setting shall mean use 
in multiple family dwellings in which one (1) MINI ULTRA tank is to be used in only 
one (1) dwelling.  In the event that a leak should develop and occur within this 
limited warranty period due to defective material or workmanship, such leak having 
been verified by an authorized company representative, Thermo 2000 inc. will repair 
or replace at our sole discretion the failed unit with the nearest comparable model at 
the time of replacement.  
 

The 

original residential purchaser is responsible for all costs associated with the 

removal and reinstallation, shipping and handling to and from manufacturing plant.  
The replacement unit will be warranted for the remaining portion of the original 
Warranty. 

 

Warranty Coverage for Commercial Installation. 

Thermo 2000 Inc. warrants to the original purchaser that the MINI ULTRA tank 
installed in a commercial setting shall be free of leaks during normal use and service 
for a period of fifteen (15) years from the date of purchase.  
 
Commercial setting shall mean use in other than residential setting stated above in 
the residential setting definition.  In the event that a leak should develop and occur 
within this limited warranty period due to defective material or workmanship, such 
leak having been verified by an authorized company representative, Thermo 2000 
inc. will repair or replace at our sole discretion the failed unit with the nearest 
comparable model at the time of replacement.  

 

The 

original purchaser is responsible for all costs associated with the removal and 

reinstallation, shipping and handling to and from Manufacturer.  The replacement 
unit will be warranted for the remaining portion of the original Warranty. 

 

Limited two years warranty on all MINI ULTRA 
components & parts 

All other MINI ULTRA components & parts are warranted for a period of two (2) 
years against defects due to defective material or workmanship.   

The 

original 

purchaser is responsible for all costs associated with the removal and reinstallation, 
shipping and handling to and from Manufacturer.  The components, repaired or 
replaced are warranted for the residual period of the initial warranty on the unit. 

 
 
 
 

Exclusions 

This warranty is void and shall not apply if: 

1.

 

Defects or malfunctions resulting from installation, repair, maintenance and/or usage 
that are not done in conformity with the manufacturer’s installation manual; or 

2.

 

Defects or malfunctions resulting from installation, maintenance, or repair that are 
not done in accordance with regulations in force; or 

3.

 

Defects or malfunctions resulting from improper installation, maintenance or repair 
done carelessly or resulting from consumer damage (improper maintenance, 
misuse, abuse, accident or alteration); or 

4.

 

Installation in which a relief valve (pressure) is not installed or if it is not functioning 
properly, or when it is not connected to a drain to avoid damage to the property; or 

5.

 

Installation in which liquid circulating in the tank does not remain in closed circuit or 
installation in which piping is leaking; or 

6.

 

A polybutylene pipe or radiant panel installation without an oxygen absorption 
barrier is used; or 

7.

 

Installation where the acidity of water is not within the normal Environmental 
Protection Agency (EPA) (between pH 6.5 – 8.5) guidelines or the domestic water 
contains abnormal levels of particulate matter or water exceeding 10.5 gpg; or 

8.

 

Your home contains any type of water softener system and the unit is not installed 
and maintained in accordance with the manufacturer specifications; or 

9.

 

The MINI ULTRA unit has been subjected to non authorized modifications; or 

10.

 

Defects or malfunction resulting of storing or handling done elsewhere than Thermo 
2000’s manufacturing plant; or 

11.

 

Units on which the serial number is removed or obliterated. 

 

Limitations

 

Thermo 2000 shall not be responsible for any damage, loss, and inconvenience of any 
nature whatsoever, directly or indirectly, relating to the breakdown or malfunction of the 
unit. This warranty limits its beneficiary’s rights. Nevertheless, the beneficiary may have 
other rights, which vary from state to state. 
 
This warranty replaces any other expressed or implicit warranty and constitutes the sole 
obligation of Thermo 2000 towards the consumer.  The warranty does not cover cost of 
removal, reinstallation or shipping to repair or replace the unit, nor administration fees 
incurred by the original consumer purchaser.  
 
Thermo 2000 reserves its rights to make changes in the details of design, construction, or 
material, as in its judgment constitute an improvement of former practices.  
 
This warranty is valid only for installations made within the territorial limits of Canada and 
the United States. 
 

 

Warranty service procedure 

Only authorized MINI ULTRA dealers are permitted to perform warranty obligations.  The 
owner or its contractor must provide Thermo 2000’s head office or authorized depot with 
the defective unit together with the following information:  MINI ULTRA model and serial 
number, copy of the original sales receipt and owner’s identification certificate. 

 

 
 

 

 

 

 

 

THERMO 2OOO INC. 

500, 9e Avenue, Richmond (Qc) Canada J0B 2H0 
phone:  (819) 826-5613   Fax:  (819) 826-6370 
www.thermo2000.com