background image

 

Operating manual 

MODEL : PC – 100W 

 

 

 

 

 

 

 

 

 


background image

 

Gratitude 

 

Thank you for your purchasing our product, we are always trying to serve 

you with a good quality as a reliable weighing instrument and enhanced   

features to supporting various kinds of conveniences of conveniences 

 

Specifications

 

 

PC-100W 

Items 

5 kg 

10 kg 

20 kg 

20 kg 

30 kg 

Min. Division 

0.5g 

1g 

2g 

1g 

1g 

Max. Tare 

Full Tare 

Linearity 

+ / - 1d 

Repeatability 

+ / - 1d 

Display Update 

9 times / 1sec. 

Display 

                                Vacuum Fluorescent Display 6 digit                                                                                                                                                                                                                                                                                         

Designators 

Zero, Stable, Net, Batt (optional) 

Operating Temp. 

- 10 

°

C ~ 40 

°

C

   

Humidity 

Below than RH 85% 

Power Source 

115, 230 AC 50, 60 Hz or Rechargeable battery(Optional)   

Consumption 

Approx. 6 W 

Fuse 

250V / 0.5A 

Platter size 

(W)350 mm x (D)270 mm 

Product size 

(W)365 mm x (D)365 mm x (H)160 mm 

Product Weights 

Approx. 8 kg(net), 10 kg(gross) 

Battery Power Pack (optional) 

Battery Charging 

11 hours with using scale 

Time 

15 hours without using scale 

Battery Duration 

15 hours with continue using 

Product Weights 

Approx.9.2 kg(net), 11.5 kg(gross) 

 

 

 

 


background image

 

Precautions 

 

● 

Locate the scale on a flat and rigid site that is free of vibrations 

● 

Locate the scale out of direct sunlight 

● 

Do not use radio devices which emit a strong electromagnetic fields near by 

● 

Do not apply sudden impact to the platter 

● 

Level the scale with four adjusters

 

● 

Do not spill the water to the scale 

 

Do not use cleaners included solvent or sinner 

 

The scale should be calibrated by authorized person prior to being used 

 

Turn on the scale at least 10 minutes before using   

 

Unpacking and assembly 

 

● 

Take out packed equipment(scale) with both hands 

● 

Take off the polystyrene and vinyl packing   

● 

Locate the scale on a rigid desk 

● 

Put stainless steel platter on the platform 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

Names of parts 

 

 

 
 
 
 
 

 


background image

 

Keys and function 

 

Keys 

Functions 

 

This key is used to set numbers

 

 

This key used to clear numbers

 

 

ZERO 

This key used to correct zero shift, activated on stabled on 

Stable marked

 

 

TARE 

This  key  used  to  entering  tare  weight,  activated  on  stable 

marked

 

 

*

 

HOLD 

This key used to hold weighing and wake up from stand by 

mode (battery pack)

 

 

MODE 

This key used to change the mode. 

Normal mode, Count mode, Limit mode 

 

SET 

This key used to set the mode 

 

Designators and functions 

 

Designators 

Functions 

ZERO 

    It indicates centered zero 

STABLE 

It indicates stable status in weighing 

NET 

It indicates tare entered 

HOLD 

It indicates the hold display 

BATT 

It indicates battery using and exhausted when blink   

 

 

0         

 


background image

 

Using Battery (optional) 

 

Scale  works  by  battery  when  not  in  using  AC  power,  please  read  carefully  for 

the  best  condition  of  rechargeable  battery,  while  scale  is  being  worked  by 

battery the designator “BATT” is indicated 

   

1. First operation from delivery 

      The  battery  may  be  exhausted  during  a  long  delivery  or  other  reasons, 

please charge the battery fully. 

 

2. Charging times 

      Times  for  a  full  charged  battery  are  11  hours  with  scale  turned  on  and  15 

hours  with  scale  turned  off.  When  you  use  a  scale  out  door  it  is 

recommended charge the battery after message “Lo-bAt” (low battery) 

 

3. Voltage indication 

      Scale indicates a voltage either turned on by power switch or restarting from 

stand by mode by “ * ” key 

 

4. Warning voltage 

      The  battery  exhausted  to  lower  level  then  scale  warns  “Lo-Bat”  with  beep 

sound  three  times,  this  means  battery  will  work  a  few  hours  more,  please 

charge the battery 

 

5. Power down voltage 

    If the scale is left after a message “Lo-Bat” for a long time then scale will put 

power  down  mode  itself,  at  this  moment  turn  off  power  switch  immediately 

and commence the charging battery 

 

6. Stand by mode 

      Scale is left without weighing or key input for a time which has been set to 

waiting time then scale will jump into the stand by mode in order to saving a 

battery  power  and  scale  will  wake  up  by  pressing  “  *”  key,  waiting  time  is 

programmable. 

 

 


background image

 

 

Operation 

 

1. Setting a waiting time(optional)

 

 

  Press “    *    ” key with empty platter(zero status) 

 

  Press “    *    ” key again, number displayed means   

waiting time in second 

 

  Waiting time changes by pressing “TARE” key 15 

seconds interval up to 3 minutes, choose a time 

*    Set time “0”for a continue operations 

 

  Press “    *    ” key programming and exit to normal mode 

 

  Remove commodity 

 

  Remove tare and press “TARE” key, designator 

“NET” is turned off 

 

2. General weighing

 

Always confirm “ZERO” mark before weighing and read weight after 

“STABLE” marked on 

  Put commodity on the platter 

   

  Read weight after stable marked on 

 

  Remove commodity 

 

 

 

 

3. Weighing with tare

 

A.  Unknown Tare 

  Place the tare on the platter 

timE 

30 

45 

324 

324

 

156 

 


background image

 

 

  Press “TARE” key, designator “NETS” is turned on 

 

  Put commodity on the tare 

 

  Read weight after designator “ STABLE” marked on 

 

  Remove commodity 

 

  Remove tare and press “TARE” key, designator 

“NET” is turned off 

 

 

B.  Known Tare 

  Enter a tare weight by number keys 

 

  Press “TARE” key, designator “NET” is turned on 

 

  Put commodity on the tare 

 

  Read weight after designator “STABLE” marked on 

 

  Remove commodity 

 

4. Weighing with hold function

 

Weighs a live animal, fishes or others, hold weighing displays a averaged weight and 

return to zero removing it(them) 

  Put fish(es) on the platter 

 

  Press “HOLD” key 

                                                                                                                                                           

“Blink” 

 

  Read a weight averaged 

 

  Remove fishes 

324 

324 

156 

156 

324 

324 

12xx 

HOLd

 

1236 

1236 

 


background image

 

 

5. Density measurements(optional)

 

Set a platform with hole and install the scale as shown illustration below, weigh a part 

in water and calculate it by density formula 

 

 

 

 

 

6. Errors table

 

 

Errors 

Meanings 

Treatments 

Remarks 

ZEro 

Initial zero failure 

Turn on scale with 

empty platter 

Call service 

 

EEP 

Memory failure 

Call service 

 

AdC 

Analog circuit failure 

Call service 

 

PArA 

Memory failure 

Call service 

 

Lo-BAt 

Low battery 

Charge battery 

Battery option 

 

 

 

 

 

 


background image

 

10 

7. Personal memorandum

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

 

 

 

 

 

 

 

 

 


background image

 

11 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACOM Inc. 

Head Office & Factory ; 
679-1 Yugyo-ri, Gunnae-myun, Pocheon-si, Kyunggi-do, 
487-875, Korea 
Tel ; +82 31 531 2205      Fax ; +82 31 531 9199 
Internet ; 

www.acominc.co.kr