T510 Weekly Programming Thermostat

 

with

 

LCD Screen

                                   

Installation Manual

 

 

Weekly Programming Thermostat  

with  

LCD Screen  

Weekly  circulation, it  is  possible  to  set  6  periods  called  events

 

each  day  with 

different  temperatures,  also  you  can  select

 

"manual  mode"  or  " temporary 

control  mode"  according  to  your  individual

 

requirements.  The  thermostat  is 

recommended for

  the control of

 

electric heating devices or on/off valve actuator 

used in water-based heating systems

 
Technical data:

 

Voltage                               : AC230V (AC110V/AC24V available)

 

Power consumption

            : 2W 

Setting range

             

   

   : 5

~90

 

Limitation range         

  

   : 5

~99

  (factory setting

: 35

Switching differential 

  

   :0.5

~10

  (factory setting

:

 

±

1

Ambient temperature

         : -5

~50

 

Protective housing

             : IP20 

Housing material

               : self-extinguishing PC

 

 

Daily use of the thermostat

 

1

  on/off "

2

  In the manual mode

press "

" or"

"to make temporary control

 

3

  Press"

" or"

" to increase or decrease pre

-

set temperature.

 

4

  Press"

"  and"

"and  hold  for  5  seconds  at  the  same  time  to  adjust 

time.  Press

  "

"  to  choose  object  to  adjust;

 

Press"

" or "

" to 

increase or decrease your set values; Press "

" to

 

confirm and exit.

 

5

  Press the "

" key to select manual mode or clock -controlled program 

mode. 

6

  It displays the time or the preset temperature alternately, and it displays 

the measured temperature directly.

 

7

  When you press 

"

" and"

"at the same time and hold for 5 seconds, 

the thermostat

  will be locked/unlocked. When it is locked, no operation 

can be carried out until it is unlocked.

 

 

Display symbols

 

  Manual mode  

  Period control mode                   

 

   

Heating                                         

  Getting up, the first period        

  Out in the morning, the second period                           

 

  Going home at noon, the third period

 

  Out in the afternoon, the

  forth period

 

 

Going home in the evening, the fifth period

 

  

Sleeping at night, the sixth period

 

 
 

Period programming

 

Press "

" and hold for 5s to enter the mode of Period programming.

 

Key 

Period 

Symbol 

Time 

 

Temperature

 

 

 

we
ek
day
 

 

06:00 

 

 

 

 

 

 S

e

th

e

 

s

tart
/e

nd 
time

  
 

20

 

S

et

 pr

o

g

ra

mme

tem
p

er

at

u

re

 

 

08:00 

15

 

 

11:30 

15

 

 

12:30 

15

 

 

17:00 

22

 

 

22:00 

15

 

we
ek
e

n

d

 

 

08:00 

22

 

 

23:00 

15

 

 
Advanced setting (qualified person preferred )

 

When the thermostat

  is turned off, You can press"

"

  and turn on it at the 

same time ,then you can enter the mode of advanced setting.

 

Symbol 

Setting 

               or 

ADJ 

Temperature

 

calibration 

Adjust measured temperature

 

 

SEN 

Sensor mode

 

IN: built-in sensor

 

OUT: floor sensor

 

ALL:  both sens

ors 

3. 

LIT  

Limitation 
temperature

 

Adjust limitation value, 
Limitation range:5

~60

 

DIF 

Switching 
differential 

Adjust switching differential 

LTP 

Antifreeze 
function 

Turn on/off Anti-frozen 
function 

PRG 

Set vacation 
mode 

00: 5/2 day mode

 

01: 6/1 day mode

 

02: 7 day mode  

RLE 

Potential- free 
output and main

 

power output in 
the 
same/different 
way 

Change the present

 

linkage way 

DLY  

Delay time of 
Potential- free 
output  

Change linkage delay time

 

HIT 

Max t emperature

 

Limitation temperature

 

setpoin t 

 

AFAC 

Reset to

 factory 

settings 

Press"

"and hold for 5s

all 

parameters will

  be reset 

 

Sensor failure:

 

Please  select  the  right  sensor  mode  when  operation,  it  will  display  the 
"Err" symbol on screen far sensor failure, thermostat must be

 

checked till 

the fault is eliminated

 

 

Explanation of symbols:

 

Period mode

Antifreeze

temperature

Lock key

heating

power

NTC

Decrease key

Increase key

Menu

Week

Time 

Six period

Manual mode

 

Dimension:

 

Unit: mm 

86

86

13

43

 

 

 

 


background image

V. 1.02

WARMTEC Sp. z o.o., Al. Jana Pawła II 27, 00-867 Warszawa

biuro@warmtec.pl

www.warmtec.pl

2

Mounting steps:

 

1  

Release the front cover by inserting a screwdriver

 

into bottom crack

 

 

  2    Taking  the  backing  plate  apart  according  to  the  following 

diagram 

 

  3    Mounted the backing plate in the wall socket by screwdriver 

 

 

4    After  connect  wires,  the  thermostat

 

mounted  on  the  backing 

plate and remounted the cover and frame

 

 

Connection diagram

 

 

1

2

3

4

5

6

7

X

L

N

N1  L1

Sensor

AC230V

16A

 

 

 

 

 

 

 

 

T510