IMPORTANT!
Please read this before installing your unit.
1. Complete wiring to backplate, clip programmer onto

backplate, 

power

power

power

power

power up

 up

 up

 up

 up

 

and rotate dial through a full

24 hour rotation.

Mounting Location

To ensure convenience of use, the RWB30 should be fitted in a position

which allows easy access. It is recommended that the unit is placed at

a height of 1.4 metres from the floor.

NB

The RWB30 should not be installed in locations that are directly

exposed to water splashes or steam from cooking utensils and

kettles etc.

Backplate

The RWB30 is supplied with the industry standard backplate to which

the system must be wired. The backplate can be fitted directly to the

wall or it may be wired on a standard conduit box. If it is fitted to a wall,

do not mount on an unearthed metal or metallic surface. If a conduit

box is fitted all wiring to the backplate should pass through the base.

The backplate is the same as that used with: RWB3, RWB30, RWB50,

RWB100 series and RWBXT Timeswitches.
When the RWB30 is used as a direct replacement no re-wiring is

necessary, (except in the case of the RWB3 when 

a link should be

inserted across Terminals L and 2 as shown in Fig. 2).

Timeswitch Wiring Diagrams

Timeswitch Wiring Diagrams

Timeswitch Wiring Diagrams

Timeswitch Wiring Diagrams

Timeswitch Wiring Diagrams

RWB30 Timeswitch Installation Instructions

RWB30

Fig. 2

* RWB30

RWB30 Timeswitch

The voltage applied to terminal 2, is switched to terminal 4 when the

timeswitch is in the ON position and to terminal 3 when the

timeswitch is in the OFF position (see Fig. 2). If 240V direct mains

switching is required link terminals L to 2.

Note:

 All external wiring must comply with current IEE regulations.

Wiring of this unit should be carried out by a qualified electrician.

Whilst every effort is made to ensure the accuracy of the instructions

given, you will appreciate that the discrepancies may occur due to a

variety of reasons outside our control. If after wiring your system you

find that it does not work properly you should:

Check that you have used the correct system and wired it correctly.

Ensure that no wiring unit links have been missed and all screws are

tight.

Check with the Technical Help line, there may be a simple explanation.

(Technical Help Line: 01952 602048 Mon - Fri 9am - 5pm).

N.B.  These units are not suitable for control of immersion

heaters.

Fitting the Unit to the Backplate

Tilt the bottom of the case away from the wall, locate the two slots in

the top of the case, over the two tabs at the top of the backplate. Push

the bottom of the case towards the wall, slotting the two backplate

screws into the bottom of the case, and tighten the screws. This

enables the contacts in the unit to engage with those in the backplate.

T

T

T

T

Technical Data

echnical Data

echnical Data

echnical Data

echnical Data

R

R

R

R

RWB30

WB30

WB30

WB30

WB30

Supply:

200/240V 50HZ

Contact rating:

6A (resistance)

2A (inductive)

Switching voltage:

24 to 240V

Ambient temperature range: 0ºC to 30ºC

Environmental humidity:

90% RH

Housing:

ABS resistant to fire as EN60730 standard

Safety Standard:

Conforms to EN60730, class A for use in

normal pollution situation.

s

Siemens Building Technologies Ltd.

Landis & Staefa Division

Hortonwood 30, Telford TF1 4ET

Tel: (01952) 677690

Fax: (01952) 602059

Help Desk

Tel: (01952) 602048

Orders

Tel: (01952) 602063

Application Example
COMBI  BOILER

Key
1

Combi Boiler

2

RWB30  Timeswitch

3

RAD Room Thermostat

Wiring Diagram for Combination Boilers

Wiring Diagram for Combination Boilers

Wiring Diagram for Combination Boilers

Wiring Diagram for Combination Boilers

Wiring Diagram for Combination Boilers

It is a good wiring practice that

the supply to the unit should be

via a two pole disconnection

providing at least 3mm air gap.

Please note:

only insert link as above

in Fig. 2 for boilers with 240V

AC.

Be warned:

most combination boilers use

24V so do 

not

 insert the link

for these applications.

Fig. 3

RWB30

Landis & Staefa Division

 


background image

RWB30 Timeswitch

User Instructions

Using Override (Advance)

To advance the programme, that is to bring forward the next ON or OFF

period as shown in the example below, press the override button.
EXAMPLE:

  WITHOUT (OVERRIDE) ADVANCE

EXAMPLE:

WITH (OVERRIDE)  ADVANCE  AT 5.35 AM

Adjusting the Clock (Dial Time)

To set the clock to the correct time of day rotate the dial clockwise as

shown by the arrow so that the correct time is adjacent to the raised

line with time written against it. Please note the dial is a 24 hour dial

with times shown numerically at two hour intervals and bars for hours

between.

NB

Do not rotate the dial anti-clockwise as this could cause damage to

the mechanism.

Changing the ON/OFF Times

The RWB30 is supplied with factory settings (See 

Factory Settings

)

which will operate unless you change the set times:
If you wish to change the factory settings to your own times you can do

this easily:
No 1 tappet (orange) is the first ON during the 24 hour period

No 2 tappet (blue) is the first OFF during the 24 hour period

No 3 tappet (orange) is the second ON during the 24 hour

period

No 4 tappet (blue) is the second OFF during the 24 hour period
To set the tappets to your own programme times hold the dial and slide

the relevant tappet and rotate it in either direction to your desired time,

then rotate dial through a full 24 hour rotation.

NB

This should be carried out with the programmer connected and

power supply switched on to the backplate.

Power Failure

In the event of a mains power failure do not move the dial until power

has been restored. If accidentally the dial has been moved during a

power failure then rotate the dial through a full 24 hour rotation before

resetting to actual time.

TAPPET No.

1

2

COLOUR

ORANGE

BLUE

ON

OFF

TAPPET No.

2

COLOUR

BLUE

OFF

Using Boost

BOOST

Pressing this button once brings the unit ON for 1 hour.

To activate 

BOOST

 push the 

BOOST

 button.

NB

This feature operates in OFF, ONCE and TWICE modes

only.

EXAMPLE:

  BOOST PRESSED AT 12.00

EXAMPLE:

 BOOST PRESSED AT 8.00

TAPPET No.

1

OFF

3

4

COLOUR

ORANGE

ORANGE

BLUE

ON

ON

OFF

TAPPET No.

1

2

BOOST

3

4

COLOUR

ORANGE

BLUE

I HR

ORANGE

BLUE

ON

OFF

ON   OFF

ON

OFF

ALL DAY

 — The unit will switch ON at the morning ON and OFF at the

evening OFF.

EXAMPLE:

CONSTANT

 — Continuously ON

When the unit is in an ‘ON’ mode as above the LED lights for each

circuit will be on.

TAPPET No.

1

4

COLOUR

ORANGE

BLUE

Introduction

The RWB30 is an advanced daily timeswitch combining the benefits of

electronic reliability and ease of use with mechanical dial operation.

Please take time to read these operating instructions carefully.
For installation see the enclosed instructions.

Features

— Up to 2 ON/OFF periods per day.

— ADVANCE feature to bring forward the next ON or OFF period as

required.

— BOOST feature to give an immediate 1 hour ON period at any time.

— Remembers last condition (ie ON or OFF) in the event of power

failure.

— Volt free contacts suitable for combination boilers.

Factory Settings

Before leaving the factory your RWB30 was programmed to switch your

system ON and OFF at the following times:

ON at 6.00 a.m.

OFF at 8.30 a.m.

ON at 4.30 p.m.

OFF at 10.30 p.m.

To activate this base programme:
Set clock dial to correct time. See 

Adjusting the Clock (Dial Time)

.

Operating Controls

All controls for daily use are located on and to the right hand side of the
dial.

Setting the Switching Programme

To make your selection slide the selector so that the vertical mark is

pointing to the desired position as below.

OFF

 — Continuously OFF.

TWICE

 — The unit will switch ON and OFF according to the morning

and evening settings.

EXAMPLE:

TAPPET No.

1

2

3

4

COLOUR

ORANGE

BLUE

ORANGE

BLUE

ON

OFF

ON

OFF