READY 

ARMED 

STAY 

BYPASS 

TROUBLE 

READY = When Green, all Zones are Sealed and  
the System is ready to be Armed. 

ARMED = Indicates the System is Armed in Away Mode. 

STAY = Indicates the System is Armed in Stay Mode. 

BYPASS = When Flashing, a Zone has been Manually Bypassed.  

TROUBLE = When Flashing there is a current System  
 

       Activation, requiring Resetting. 

TROUBLE = On Steady the Activation has been Reset,  
 

       but a Fault still remains. 

Please see the Memory  

 

       Display page for Current System Fault codes.

 

Area Activation indicators 

Zone Activity indicators 

Memory/Event indicator 

Multi Function Display 

= ARM will put the system into Away/Normal Armed State. 

= STAY will put the system into Home/Stay Armed State. 

= BYPASS followed by a zone number (i.e. 01, 12 ect.) then enter will disable that zone. 

= CONTROL is an extra function button, that can be used to control outputs. 

= PANIC will put the system into an immediate alarm activating the sirens. 

= MEMORY allows you to view current and past events, 

see page 4 for more info.

 

= PROGRAM is used to get into client and installer modes, to change programming. 

= Will turn ON and OFF Chime Mode 

Page 2/8 

Then hold 

 


background image

Local Edit Mode gives you the ability to adjust some individual keypad functionality.   

 

Including:12/24 hour time, Temperature display, KP Tamper, KP software version, KP Address,  
 

   Calibrate Temperature, Backlight Brightness, Display Contrast and Beeper Tone. 

To Enter Local Edit Mode, please press               then               then  

 

The display will then read    

 

To Exit Local Edit Mode, please press               then  

Once in Local Edit Mode use the programming addresses below to make changes if required. 

 

  P=                 E =   

To Increase press  

To Decrease press 

P 900 E  1 ON = 12-hour clock, 1 OFF = 24-hour clock 
 

2 ON = Clock and Temperature displayed alternatively, 2 OFF = Clock Only 

 

3 ON = Display Temperature when ENTER button is pressed, 3 OFF = Feature disabled  

 

4 ON = Enable Keypad Tamper 

(Not available on this Keypad) 

 

5 ON = All Lights will turn off after 90seconds of inactivity.  

 

P 901 E  Keypad Software Version, 

the KP current software version will be displayed. 

 

P 902 E  Keypad Address (1-8) 

keypads on the same system must each have a different address 

 

P 903 E  Calibrate Temperature Sensor

the current temperature will be displayed. 

 

 

(

Warning 

don’t adjust this location unless you have a calibrated temperature source available )

 

 
P 904 E  Backlight Brightness

display will read                  to adjust press              or

 

 

P 905 E  LCD Contrast

display will read                  to adjust press              or

 

 

P 906 E  Buzzer Tone

display will read                  to adjust press              or

  

 

P 920 E  Default 

all Keypad Local Edit Programming Options will be returned to factory default.

 

 

Note, after adjusting any programming options,                       must be pressed to save changes. 
 
 

*You can not access Local Edit Mode if the system is Armed or Stay Armed

 

Page 3/8 

 

Lights Out Mode: This great little feature is perfect if you find the keypad backlight is too bright,  
when installed in a bedroom. If option 5 is turned On under Local Edit Mode address P 900 E, the 
backlight behind the display and the buttons will turn off, after 90 seconds of no zone activity. If a 
zone is then triggered the backlight will come back on for 90 seconds. The backlight will also come 
back on if a button is pressed. 

 

Easier Programming: We’ve added a simple step through ability to commonly used programming 
addresses. For example enrolling Radio Pendants, start like normal in program mode then P 18 E 21 E 
once the first slot is loaded, pressing           will step you to the next slot for loading and so on.  
This feature works on most addresses, such as user codes, user permissions, phone numbers & more 

 


background image

YEAR 

MONT

DAY 

TIME 

FLASHING 

ON 

SLOT NO. 

A  

A Zone light may appear, indicating 
what Zone the Memory Event relates to.  

A letter indicates what Area the  

Memory Event relates to.  

Past Event Code 

next  

memory  

event 

exit out of 

memory mode 

Flashing = Past Event 
(use Past Event Code table)  

*=not availabe  
for all events 

action by* 

On Steady = Current Event 
(use Current Event Code table)  

Current Event Code 

Pressing the Memory button once will bring 
up any Current System Faults/Alarms 

Continuing to press the Memory button will cycle 
through the Past Events from newest to oldest 

when event 
occured  

= Battery Low (BATTery Low)  

= Mains fail (AC Power Fail)  

= Dialler Kiss-Off Failure (Call Failure)  
= Keypad Missing (KeyPad Sabotage Alarm) 

 

= Line Fail (Telephone LINE Fault)  
= 12V fuse or Output Failure (OutPut or FuSe Failure) 

 

= Pendant Battery Low (Pendant BATtery Low)  
= RF battery Low (Radio Zone BATtery Low)  
= Delinquency Alarm (Area DELinQuency Alarm)  
= Supervised Detector Failure (Radio Zone SUPervise Signal Failure)  
= SensorWatch Alarm (Zone SensorWatch Alarm)  

= No Current System Faults 

Page 4/8 

 


background image

= 12V Fuse Failure Alarm (12V Fuse Failure Alarm) 
= 12V Fuse Failure Restore (12V Fuse Failure Restore)  
= 24 Hour Zone Bypass Reinstated (24 Hour Zone Bypass Re-Instated) 
= 24 Hour Zone Bypass (24 Hour Zone BYpass)  
= 24Hour Zone Alarm (24 Hour Zone Alarm)  
= 24 Hour Zone Alarm Restore (24 Hour Zone Alarm Restore)  
= AC Power Fail Alarm (AC Power Fail Alarm)  
= AC Power Fail Restore (AC Power Fail Restore)  
= AC Fail Reported via Dialler (AC Fail Reported Alarm)  
= AC Fail Restore Reported via Dialler (AC Fail Restore Reported)  
= Automatic Test Message sent (Automatic TeST Message sent) 

 

= Area Armed by ARM button (AWay by ARM Button) 

 

= Auto Arm Fail Restore (Away AUto-Arm Fail Restore 

 

= Auto Arm Fail (Away AUto-Arm Fail) 

 

= Area Armed by Keyswitch (AWay by KeySwitch) 

 

= Area Armed by Upload/Download (AWay By PHone) 

 

= Area Armed by DTMF (AWay Armed by PHone) 

 

= Area Armed by Pendant (AWay by Pendant-TX

 

= Area Armed by Time Zone (AWay by Time Zone) 

 

= Area Armed by User (AWay by User) 
= Panel Low Battery (Panel Low BATtery Alarm) 

 

= Panel Low Battery Restore (Panel Low BATtery Restore) 

 

= Clock Changed by PC (Clock Changed by PC

 

= Clock Changed at panel (Clock Changed at PaNel) 
= Callback Initiated (CalLBacK Initiated) 

 

= CRC Error (CRC Error) 

 

= Panel Defaulted (Panel DEFauLted) 

 

= Area Delinquency Alarm (Area DELinquency Alarm) 

 

= Area Delinquency Alarm Restore (Area DELinquency Alarm Restore) 

 

= DTU Data sent to Panel (DTU to Panel Transfer) 

 

= Excessive Code Attempts Alarm (Excessive CoDe Attempts Alarm) 

 

Page 5/8 

 


background image

= Event Buffer Cleared at Keypad (EVent Buffer Cleared at KeyPad) 

 

= Event Buffer Cleared from PC (EVent Buffer Cleared from PC
= Duress Alarm at Keypad (KeyPad Duress Alarm) 

 

= Fire Alarm at Keypad Restore (KeyPad Fire Alarm Restore) 

= Fire Alarm at Keypad (KeyPad Fire Alarm) 

 

= Duress Alarm at Keypad Restore (KeyPad Duress Alarm Restore) 

 

= Medical Alarm at Keypad (KeyPad Medical Alarm) 
= Medical Alarm at Keypad Restore (KeyPad Medical Alarm Restore) 

 

= Panic Alarm at Keypad (KeyPad Panic Alarm) 
= Panic Alarm at Keypad Restore (KeyPad Panic Alarm Restore) 

 

= Keypad Missing (KeyPad Sabotage Alarm) 
= Keypad Re-Instated (KeyPad Sabotage Restore)  
= Keypad Tamper Alarm (KeyPad Tamper Alarm) 
= Keypad Tamper Alarm Restore (KeyPad Tamper Alarm Restore) 

 

= Manual Test Message sent (Manual TeST Message sent) 

 

= Area Open by ARM Button (OPen by ARM Button)  
= Area Open 

Normal or Stay by Keyswitch (OPen by KeySwitch) 

= Output Turned Off by KP/Control/PC or DTMF (OutPut Turned OFF) 

 

= Output Turned On by KP/Control/PC or DTMF (OutPut Turned ON
= Area Open 

Normal or Stay by PC or DTMF (OPen by PHone) 

 

= Area Open Stay by STAY Button (OPen Stay by STAY Button) 

 

= Output Tamper Alarm (OutPut Tamper Alarm) 
= Output Tamper Alarm Restore (OutPut Tamper Alarm Restore) 
= Area Open 

Normal or Stay by Pendant (OPen by Pendant-TX

 

= Area Open by Time Zone (OPen by Time Zone) 

 

= Area Open 

Normal or Stay by User (OPen by User)  

= PC to Panel Comms Ended (PC to Panel Comms OFf) 

 

= PC to Panel Comms Started (PC to Panel Comms ON

 

= Panel Data sent to DTU (Panel to DTU Transfer)  
= Telephone Line Failure (TelePHone Line failure Alarm) 

= Excessive Code Attempts Restore (Excessive CoDe Attempts Restore) 

 

Page 6/8 

 


background image

= No Kiss-Off to Dialler Event (PHone Call Not Kissed-Off ) 

 

= Exit Program Mode (PRoGram Mode Exit) 

 

= Enter Program Mode ( PRoGram Mode Entry) 

 

= Receiver Fail (ReCeiVer Fail) 

 

= Receiver Fail Restore (ReCeiVer Fail Restore) 

 

= RF Zone Battery Low (RF Zone Battery Low Alarm) 

 

= RF Zone Battery Restore (RF Zone Battery Restore)  
= RF Interference Alarm (RF Interference Alarm) 

 

= RF Zone Supervise Fail Restore (RF Zone Supervise Fail Restore)  

 

= RF Zone Supervise Fail Alarm (RF Zone Supervise Fail Alarm) 

 

= RF Interference Alarm Restore (RF Interference Alarm Restore) 

 

= RF Zone Tamper Alarm (RF Zone Tamper Alarm) 

 

= RF Zone Tamper Restore (RF Zone Tamper Restore) 

 

= Radio Zone Deleted (Radio-RF Zone Deleted) 

 

= Learning Radio Zone (Radio-RF Zone Learning) 

 

= Spare Off 2 

 

= Area Armed Spare 1  
= Area Armed Spare 2 

 

= Area Open Spare 2 

 

= Area Stay Armed by Keyswitch (STay by KeySwitch) 
= Soak Test Off (Soak Test OFf)  
= Soak Test On (Soak Test ON

 

= Area Stay Armed by Upload/Download (STay Armed by PC

 

= Area Stay Armed by STAY button (STay Armed by STAY Button) 

 

= Area Stay Armed by Pendant (STay by Pendant-TX

 

= Area Stay Armed by User (STay by User) 

 

= System Tamper Alarm (System TaMPer Alarm) 

 

= System Tamper Alarm Restore (System TaMPer Alarm Restore) 

 

= Pendant-TX Battery Low (Pendant-TX Battery Low Alarm) 

 

= Telephone Line Failure Restore (TelePHone Line Failure Restore) 
= Dialler Call Un-answered (PHone Call Not Answered) 

Page 7/8 

 


background image

= Walk Test Off (Walk Test OFf) 

 

= Pendant-TX Panic Alarm Restore (Pendant-TX Panic Alarm Restore) 

 

= Learning Pendant (TX-Pendant Learning) 

 

= Walk Test On (Walk Test ON

 

= Zone Arm Alarm (ZonArm Alarm) 

 

= Zone Arm Alarm Restore (ZoNe Arm Alarm Restore) 

 

= Zone Bypass Re-Instated (ZoNBypass Re-Instated) 

 

= Zone Bypass (ZoNBYpass) 

 

= Zone Near Alarm (ZoNNear Alarm)  
= Zone Near Alarm Restore (ZoNNear Alarm Restore) 

 

= Zone Stay Alarm (ZoNStay Alarm) 

 

= Zone Stay Alarm Restore (ZoNStay Alarm Restore)  
= Zone Tamper Alarm (ZoNTamper Alarm)  
= Zone Tamper Alarm Restore (ZoNTamper Alarm Restore) 

 

= Zone Verified Alarm (ZoNVerified Alarm) 

 

= Zone Verified Alarm Restore (ZoNVerified Alarm Restore) 
= Zone Sensorwatch Alarm (Zone SensorWatch Alarm) 
= Zone Sensorwatch Alarm Restore (Zone SensorWatch Alarm Restore) 

 

= Pendant-TX Battery Low Restore (Pendant-TX Battery Low Restore) 

 

= Pendant-TX Panic Alarm (Pendant-TX Panic Alarm)  
= Pendant Deleted (TX-Pendant Deleted) 

 