background image

A8 17

CXW-220-A817

CXW-220-A815

Range Hood

User Manual

Before

 

operating

 

this

 

unit

please

 

read

 

the

 

ser

 

manual

 

completely

 

and

 

keep

 

it

u


background image

Safety Precaution..........................................................................................

....1

Important Information.......................................................................................

.............3

Product Overview.................................................................................................

........4

Packing List.........................................................................................................

.... ....4

Installation Instructions......................................................................................

....5

User Manual.........................................................................................................

8

Maintenance..........................................................................................

10

Removal of Components...........................................................................................

10

Circuit Diagram.......................................................................................................

.. 12

Troubleshooting of General faults........................................................................................ 13

......................

..........

...........

...........

.

.................

..................

...............................

............

........... .

..

CONTENTS


background image

Prohibit  water  on  motor,  switches  or 
other electric parts; Prohibit wash range 
hood  by  water  spray.  Don’t  use  range 
hood  if  wet  or  it  may  cause  electric 
leakage or shock. 

Don’t  touch  plug,  electric  parts  or 

button  by  wet  hands,  or  it  may  cause 

electric shock. 

Safety

 

Precaution

Subject

 

to

 

harmful

 

or

 

destruct

 

degree

 

In order to avoid harm or property damage to the users or other person, the following distinction and marks 

are stipulated. They are important safety precaution, please comply strictly based on the full understanding. 

Danger

If

 

ignore this sign and operate product improperly, it’s highly possible to cause danger, 

serious injury or fire. 

If

 

ignore this sign and operate product improperly, it’s possible to cause danger, serious 

injury or fire. 

If

 

ignore this sign and operate product improperly, it’s possible to cause  injury or loss. 

Please

 

use

 

this

 

product

 

according

 

to

 

manual

 

strictly, or ROBAM shall not take any

responsible caused by improper operation. 

Don

'

t

 

allow children or weakling to use 

range hood separately, or it may cause 

electric shock or other accident. 

The  electric  wire  must  be  cut  off  before 

clean,  install  or  maintain  range  hood 

avoiding from electric shock. 

Don’t  change,  stretch,  bind  or  press 

electric  wire,  or  it’s  possible  to  cause 

electric shock or fire because of broken 

wire.

Prohibit  any  change  of  interior  circuit, 

or  it  may  cause  injury  or  other  danger, 

for example, electric shock or fire. 

Please

 

turn

 

off

 

range

 

hood

 

immediately

 

if

 

pan

 

got

 

fire

  (

range

 

hood

 

shall 

aggravate  fire  if  it’s  working)  and 
extinguish  fire  by  effective  action.  For 
example, cover flame by metal cover, turn 
off  gas  valve  immediately  and  remove 
inflammable things.

 

Any

 

abnormal,  please  turn  off  power, 

take  off  plug  or  cut  off  electric  source, 

and  contact  service.  It’s  possible  to 

cause  electric  shock  or  fire  if  using 

range hood under abnormal situation. 

Notice

 

and

 

Prohibit Mark

1

Warning

Notice

Danger

Prohibit

Prohibit

 

Flame

Prohibit

 

Touch

Prohibit

 

Touch  

by Wet Hand

   Prohibit 
Disassembly

   Strict

 

Execution

Neccessary 
Earthed

 

    Caution 
Electric Shock

Caution Scald

Warning

Prohibit

Prohibit

Prohibit

Prohibit

   Strict 
Execution

   Strict 
Execution

   Strict 
Execution

Prohibit

 

Touch

 

by

 

Wet

 

Hand

Dear users:

  

Range Hood

Thank

 

for

 

your

 

buying

 

our

 

range

 

hood

Please

 

accept

 

our

 

best

 

regards

.

Please

 

read

 

this

 

u

ser

 

manual

carefully

 

before

 

installation and operation.

*

The  pictures  in  this  manual  only  for  your  reference.  If  the  picture  isn’t  accord  with  object,  subject  to  object.  We 

keep to right to update appearance, structure or products without notice.  


background image

   Strict 
Execution

   Strict 
Execution

   Strict 
Execution

   Strict 
Execution

   Strict 
Execution

   Strict 
Execution

In  order  to  ensure  safety,  range  hood 

must be installed by specific accessory ( 

especially  expansion  pipe  and  wooden 

screws, or it may cause accidental drop 

of  range  hood).  The  pipe  bore  and  hole 

must  fit  tightly  during  the  installation  of 

metal  expansion  pipe.  It  is  prohibited  to 

make  excessively  large  hole  to  prevent 

accidental  drop  of  loosening  expansion 

pipe.

The  range  hood  must  be  used  by 

specific plug and properly ground it. It’s 

possible  to  cause  electric  shock,    hot 

plug  or    fire  because  of    improper 

electric  wire.  Installation  must  be 

executed by professional person based 

on  local  electrical  regulations.  Before 

connect  electricity,  power  must  be 

turned off. 

I f  e l e c t r i c a l  w i r e  i s  b r o k e n ,  o n l y 

professional engineer can replace it. 

 If the range hood will be used with the 

kitchen  range  burning  gas  or  other 

fuels, the room must be well ventilated.

The range hood and electric circuit must be 

installed  by  skilled  and  trained  personnel 

w i t h   r e q u i r e d   q u a l i f i c a t i o n .   W h e n  

installation, the related regulation, standard 

or instruction on fire must be   complied. It 

may  cause  danger  because  of  improper 

installation,  for  example,  electric  shock, 

drop or fire accident.

R a n g e

 

h o o d

   

m u s t

 

b e

 

i n s t a l l e d ,  

d i s a s s e m b l e d   o r   m a i n t a i n e d   b y

 

professional

 

person

.

Put  out  the  stove  fire  in  time  when  it 

is not used. That the stove fire bakes 
the range hood directly is prohibited. 
Do  not  barbecue  food  directly  under 
the range hood lest the range hood is 
damaged  and  an  accident  should 
occur.

All  operation  must  comply  with  our 

safety guidelines as well as local safety 

regulations. 

The  range  hood  is  used  only  daily  life  not 

special environment ( for example, outside). 

And it’s not allowed to exhaust dangerous or 

explosive  matter  or  air.  It  should  be  put 

under  dry  and  ventilation  environment 

without dangerous air. 

The outlet must be connect with outside. In 

order to ensure safety and fresh air, waste 

gas    should  be  exhaust  to  outside.  Don’t 

exhaust waste gas to the wall, loft or garage. 

Don’t  touch  bulb    if  it’s  on  or  just  close  in 

short time, or it may cause scald. 

It may get fire if cleaning range hood not in 

accordance with manual. 

Keep a good habit to turn off gas hob and gas valve if go outside, sleep or finish operation. Replace or 

check gas pipe regularly, since gas alarm device can’t completely avoid accident caused by gas 

leakage. 

2

Warning

Prohibit

   Prohibit

 

Disassembly

Prohibit

 

Touch

   Strict

 

Execution

   Strict

 

Execution

   Strict

 

Execution

   Strict

 

Execution

  

Range Hood


background image

3

Because  the  installation    is  difficult  and 

hood  is  heavy,  the  installation  shall  be 

executed  by  professional  person  based 

on manul. 

B e f o r e

 

r e m o v i n g

 

r a n g e

 

h o o d

 

f o r

 

installation

clean

 

or

 

maintainance

  , 

power

 

must

 

be

 

cut

 

off  avoiding  from 

electric shock. When installation, clean 

or  maintainance

protective

 

gloove

 

must

 

be

 

wear

 

avoiding

 

from

 

injury

Don

'

t

 

break

 

electric

 

wire

 

or

 

other 

i n v i s i b l e  e q u i p m e n t  w h e n  c u t t i n g 

something or drilling holes on ceiling.

When

 

the

 

oil

 

exceeds

 

2/3

 

or

 

near

 

tick

 

mark

 

in

 

the

 

oil

 

cup

clean

 

it

 

in

 

time

Don

'

t

 

eat

 

waste

 

oil

 

from

 

oil

 

cup

The

 

gas

 

from  range  hood  shall  not  be 

exhausted to hot flue used for burning gas or 

other fuels. 

When  range  hood  is  using  in  well 

sealed  building,  it  should  have  air  inlet 

or open door to ensure good ventilation. 

T h e  t e m p e r a t u r e  f o r  r a n g e  h o o d 

working can’t exceed 

40℃

.

The  wall  of  installing  range  hood  needs 

enough  strength.  For  hollow  walls,  the 

thickness of solid layer of hollow wall must 

be more than 30mm, but for concrete walls, 

it can be drill holes directly. The range hood 

must be fixed on the wall firmly. 

重要信息

Notice

Prohibit

Important Information

Package

 

of

 

Range Hood

Before use  Range hood

     

Please

 

settle those packages carefully in order to protect environment. 

     

Don’t allow children to play plastic film and package, it may cause asphyxia. Please avoid children near package 

   

material. 

    This range hood exhaust fume outside.

    Please read this manual and all information carefully before installation and operation. Please comply with our 

suggestion. If it’s necessary, please read manual for gas hob. And please keep these manual carefully for future 

reference.

    This manual is available for different models. So you may find different description with your own range hood.

    If range hood has obvious damage,  please don’t electrify and contact operator. 

    This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety.

    Children should be supervised to ensure that they do not play with the appliance.

   Strict 
Execution

   Strict 
Execution

   Strict 
Execution

   Strict 
Execution

   Strict 
Execution

   Strict 
Execution

   Strict 
Execution

  

Range Hood


background image

4

322

500

(

505

)

359

895

5

3

7

The marked sizes are for reference only. The height of drawing panel is 430, and the size in brackets is specific 
to A815

 

hood

. (

Unit

mm

7

0

220Pa

A817:895

×

500

×

A815:895

×

505

×

537

537

Rated Input Power of the Main Motor

58dB

23%

22kg

Dimensions (L×W×H)

mm

Odour Decrease Rate (Normal)

Odour Decrease Rate (Instantaneous)

76%

340Pa

98%

Rated Input Power of the Hood A817:222W  A815:224

220W

Grease Separation Rate

92%

Noise

Maximum Input Power of the Light

Net Weight of the Host

220-240V-

 

50Hz

Body Size

3

        18m /min

CXW-220-A817

CXW-220-A815

Note:

 

1.The deviation between the expressed value and measured value of air flow rate,

 

maximum static pressure 

and nominal wind pressure shall not exceed 

-

10% of the expressed value. 

3

2

When

 

stir

-

frying

 

function

 

is

 

enabled

the

 

air

 

flow rate is 19m

/

min

A817:

A815:

2W   

2W

×

2

Maximum

 

Static

 

Pressure

Model

Power Supply

Total Pressure Efficiency

Nominal

 

Pressure

Air

 

Flow

 

Rate

Technical Specification

Product Overview

  

Range Hood

Packing List

Please

 

check

 

lists

 

if

 

open

 

the

 

package.

P

a

c

k

in

g

 

 

L

is

t

No

.

Name

Quantity

No

.

Name

Quantity

1

12

11

6

5

4

3

2

Range hood

Plastic

 

expansion

 

pipe

1

 

piece

4

 

pieces

1

 

piece

1

 

set

S

 

T4x18

 

self

-

tapping

 

screw

10 piece

13

S 4

×

 

wooden

 

screw

 

T

60

4

 

pieces

10

Hitching foot stopper

 

1 piece

1 pair

7

8

Hitching 

 

foot

1 piece

9

1

 

set

Φ185 (O

D

aluminum exhaust pipe

Exhaust pipe connection

Exhaust pipe tape

Exhaust pipe fixed strip

User manual

Check valve

M6 metal expansion pipe

Oil

 

cup

1piece

14


background image

5

Installation

Notice

Keep the hood away from too many doors and windows, so as to avoid air convection affecting the efficiency.

 

Tools preparation

The hood will be installed with the following tools:1. an impact drill (with drill bit) 2. a wrench 3. a screwdriver; and 
4. a ruler.

Surrounding

Preparation for installation

Installation  and  circuit  setting  must  be  done  by  experienced  professionals.  Only  a  professionally  trained 

person  with  an  installation  qualification  can  install  the  hood.  Non-professionals  are  not  allowed  to  install, 

dismantle and repair the hood

.

Please do not power on the

 

hood

 

before

 

installation

 

to

 

avoid

 

electric

 

shock

.

Do  not  expose  the  hood  if  your  kitchen  is  under  renovation,  because  construction  materials,  dusts,  paint,

 

coatings, and emitted gases will corrode and tarnish the hood surface

Therefore, it is recommended

 

to

 

install

 

it

 

after

 

the

 

renovation

 

is

 

completed

.

Don

'

t  install  the  hood  on  wood  and  other  combustible  walls.  The  wall  shall  be  made  of  noncombustible 

materials with enough strength and the surface shall be flat.

The hood may have very sharp edges. So, please wear protective gloves during hood installation, cleaning 

or repair.

When drilling on the wall or ceiling board, keep away from embedded wires and other concealed devices to 

avoid electric shock and fire

.

Do  not  install  the  hood  at  a  too  high  position  as  well  as  keep  the  hood  free  from  disturbance  of  ambient 

airflow lest the reduction of smoke pumping effect shall occur.

When making cabinet, please leave space for installation and disassembly of the hood in order to maintain 

and overhaul the hood.

When installing, please keep the machine body remain horizontal

.

Please use single phase grounded socket and the hood shall be well grounded (water pipe grounding is not 

reliable and gas pipeline grounding has risks of causing fire disaster and explosion)

.

In  order  to  ensure  safety  and  successful  installation,  please  use  standard  accessories  provided  with  the 

hood for installation, otherwise the hood may be at risk of falling down.

If the power cord is damaged, in order to avoid danger, it must be replaced by manufacturer, professionals 

of  its  maintenance  department  or  similar  departments

Please  do  not  carry  out  restructuring,  stretching, 

knotting  and  squeezing  or  apply  heavy  objects  to  the  power  cord,  etc.,  otherwise  it  may  cause  power  cord 

damage easily,

 

leading to accidents such as electric shock and fire disaster, etc

.

After installation, please clean the surface of the hood, and then supply power for test run

.

Warning

1.The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or 
other fuels,the

 

discharge

 

of

 

air

 

must

 

fulfill

 

the

 

requirements

 

of

 

local

 

regulations

.

2.Note that when installing the metal expansion pipe, the pipe shall match with the hole in size. Overlarge hole is 
prohibited, as it will result in loose pipe and accidental drops. 
3.There shall be adequate ventilation of the room when the range hood is used at the same time as appliances 
burning gas or other fuels.
4.If the flue aperture is less than air duct

 

aperture,

 

it

 

will

 

influence

 

the

 

fume

 

suction

 

effect

 

and

 

the

 

too

 

long

 

air

 

duct

 

will

 

influence

 

the

 

fume

 

suction

 

effect, too

.

5.This product is only for daily use and please do not use it under special environment (e.g. outdoor)

nor

 

can

 

it

 

be

 

used

 

to

 

exhaust

 

hazardous

 

or

 

explosive

 

substance

 

or

 

gas

Before

 

assembly

the

 

product

 

shall

 

be

 

placed

 

in

 

environment

 

which

 

is

 

dry

ventilated without corrosive and harmful gas in the surrounding. 

  

Range Hood


background image

8328

Installation

6

500(505)

6

0

0

-8

0

0

6

5

0

-7

5

0

8

0

0

-9

0

0

10

Ceiling

Removable panel

Removal baffle

(

Figure

 

 

Installation

 

method

 

of

 

hood

 

without

 

removable

 

baffle

)

1-1

CXW

-

200

-

8312

Figure 2

Figure 3

1

0

0

468

Ceiling hole sizes

(

Figures

 

in

 

brackets

 

are

 

specific

 

to

 

the

 

A

815 

hood

)

5

0

0

(5

0

5

)

895

Projection size 
of

 

the hood top

Walls

Hole size of the exhaust pipe

φ

200

Install hitching feet

       

According to the dimension of hitching feet

drill four 60-70mm deep holes (overlarge holes are prohibited) 

accordingly with an 8mm diameter drill bit. Press the expansion pipe into the holes, and then fix the hitching feet

 

reliably

 

with 4 provided ST4

×

60 wood screws. Drill a hole with diameter of 10mm and depth of 50-55mm at the position 

65mm above the four holes and insert the M6 metal expansion pipe into the hole. (See Figure 2)

A8 17

8328

6

0

0

-8

0

0

6

5

0

-7

5

0

8

0

0

-9

0

0

10

35

±

2

Hitching foot stopper

Hitching foot

235

110

55

55

4

9

5

6

5

±

2

  

Range Hood

(

Figure

 

 

Installation

 

method

 

of

 

hood

 

with

 

removable

 

baffle

)

(

Figures

 

in

 

brackets are specific to the A815 hood)

1-2

Determine the position

    

Ceiling

Drawing panel

Mounting hole of 
the drawing panel

Main hood panel

ST4X18 
self-tapping

                     The hood shall be installed right above the hob. The minimum distance between the bearing surface of 

cooking appliance and the lowest part of hood is 650mm (larger space specified in the installation instruction of 

gas hob shall be considered. The distance for electric cooker may be reduced appropriately, depending on the 

actual situations)

       The size of removable baffle (reference: 430mm) can be adjusted according to the actual situations. The 

installation pitch of holes is shown in Figure 2. The hood body shall be centered vertically and kept level. Ceiling 

hole size is shown in Figure 3.


background image

Drilling position of the aluminum foil exhaust pipe (public flues do not require drilling)

a. Aluminum foil exhaust pipe and hob facing the window:

 

Remove one of the glasses and install a plywood

 

with

 

ventilation

 

holes

 

or

 

punch

 

directly

 

on

 

the

 

glass

b. Hob away from the window:

 

Install the aluminum foil exhaust pipe through the window that is close to the hob 

and connected outside

or install it by punching on the wall that is close to the hob and connected outside. 

c. Drill hole through the wall:

 

Determine the location of the aluminum foil exhaust pipe against the wall and draw 

the drilling range (i.e. a circle slightly larger than the pipe OD). Then use a long drill bit to drill through the wall. Pay 
attention to the wall structure and material, so as not to destroy other parts of the wall.

 

Link the aluminum foil exhaust pipe

Insert  the  end  of  aluminum  foil  exhaust  pipe  without

 

fixed

 

strip

 

to

 

the

 

pipe

 

connection

 

and

 

stick

 

with

 

tapes

Straighten

 

the

 

aluminum

 

foil  exhaust  pipe  and  then  connect  the  pipe  to  the  connection  of  public  flue  outlet

 

(

straighten

 

the

 

pipe

 

directly

 

to

 

the

 

outdoor

 

if

 

there

 

is

 

no

 

public

 

flue

). 

This

 

can

 

be

 

done

 

directly

 

when

 

the

 

public

 

flue

 

connection

 

or

 

wall

 

hole

 

is

 

larger

 

than

 

the

 

pipe

Otherwise

there

 

are

 

five

 

types

 

of

 

pipe

 

connection

 

small

 

ends

 (

OD

140, 150, 160, 170 

and

 180 

respectively

to

 

be

 

chosen

 

from

 

according

 

to

 

the

 

hole

 

size

Then

 

cut

 

the

 

excess

 

part

 

with

 

scissors

Then insert the end of the aluminum foil exhaust pipe with fixed strip in the outer ring of the check valve connection 
and seal with exhaust pipe tapes. At last, put four snaps of the check valve connection in corresponding slots, and 
rotate them clockwise to fix the exhaust pipe to the check valve. 

Install the aluminum foil exhaust pipe

7

Adjust drawing panel

       

Pull the two brackets of the drawing panel upwards to an appropriate height and then pull out the drawing 

panel by holding both sides. Remove the protective film (excluding cold plate materials) on the drawing panel and 
insert it along the gap between the main hood panel and the housing.

 

Then adjust it to the proper height. 

Install hood body

    

Fix the check valve as shown in Figure 5. Then align the hanging holes in the back of hood with the hooks of 

hitching feet

 

according

 

to

 

Figure

 

2 and

 

press

 

them

 

together

Shake

 

the

 

body

 

to

 

check

 

if

 

it’s hung securely. 

After the body is mounted, install the hitching foot stopper and gaskets to the M6 metal expansion pipe, and then 
tighten the nuts (to prevent accidental decoupling of the body under external force). 

Install drawing panel

       

As shown in Figure 1-1, there is certain gap between the drawing panel and the top plate. Push the panel 

against the top plate and then fix it to the top plate with ST4

×

18 screws.

(

If

 

installation

 

method

 

in

 

Figure

 

1-2

 

is

 

adopted there’s no need to adjust and install the drawing panel)

Figure 5

Figure 4

Φ

1

9

0

Φ

1

8

0

Φ

1

7

0

Φ

1

6

0

Φ

1

5

0

Φ

1

4

0

  

Range Hood

The exhaust wall hole diameter shall be close to that of the exhaust pipe, which shall not be too small. Otherwise, it 
will cause poor exhaust efficiency, more noises and lower airflow, etc. The connection between the pipe and the 
hole  or  the  public  flue  must  be  sealed  tightly  to  ensure  that,  the  pipe  and  the  check  valve  or  public  flue  are 
connected securely. The blades at the check valve connection or public flue connection must be flexible.

Note: During installation, straighten the aluminum foil 
exhaust pipe to avoid noises in semi-stretched state. 
Excess part may be cut with a wire cutter. 

 

Φ185 aluminum foil exhaust pipe

Exhaust 
pipe tape

Exhaust pipe 
connection

Cut the excess part smaller than the wall hole

Exhaust pipe tape

Body

Check valve

Check valve connector

ST4X18 screw

Check valve seal

Buckle

Slot


background image

User Manual

8

Plug in and 3 ticks from the buzzer will indicate qualified installation. Now the hood is in standby.

Light

Weak

Power

Switch Control Panel

Stir-frying/Strong

Maintenance

Press  Power

 

button

the

 

icon

 

is

 

on

 

and

 

the

 

hood

 

is

 

powered

 

on

 

waiting

 

for

 

operation directions. When the  Power

 

icon

 

is

 

lit

 

up

 

and

 

only

 

the

 

spotlight

 

is

 

on

press

 

the

 

power

 

button

 

gently

 

and

 

the

 

spotlight

 

will

 

be

 

turned

 

off

 

directly

if the 

fan is working under power-on mode, press the  Power

 

button

the

 

power

 

icon

 

will

 

flash

 

and

 

the  hood  will  enter  delayed  working  state,  and  all  working  state  will  be 

disabled  after  1min  (under  delayed  working  state,  all  Stir-frying/Strong

Weak

 

and

 

Light

 

buttons

 

will

 

be

 

disabled

);

When the  Power

 

button

 

and

 

all

 

functions

 

are

 

shut

 

down

.

Under  power-on  mode,  press  “Stir-frying/Strong”

 

button

 

to

 

enable

 

the

 

stir

-

frying

 

function

When

 

the

 

icon

 

twinkles

press

 

the

 

button

 

again

 

to

 

switch

 

to

 

strong

 

level

In

 

case

 

no

 

operation

 

is

 

taken

 

after

 

enabling

 

the

 

stir

-

frying

 

function

it

 

will

 

switch

 

to

 

strong

 

level

 

automatically

 

after

 

3

 

minutes

 

and

 

the

 

icon

 

will

 

stay

 

on

 

under

 

strong

 

level

Under standby mode, press the “Light”

 

button

 

once

 

to

 

turn

 

on

 

the

 

light

 

and

 

repress

 

to

 

turn

 

off

Each

 

press

 

will

 

trigger

 

a

 

tick

 

from

 

the

 

buzzer

The “Light”button

 

only

 

controls

 

the

 

light

Under power-on mode, press the “weak”

 

button

 

and

 

the

 

impellers

 

will

 

rotate

 

at

 

low

 

speed

 

to

 

inhale

 

smoke (which shows the weak level is switched on). Repress the button to turn 

off. 

  

Range Hood

Warning

1

.

There is a fire risk if cleaning is not carried out in accordance with the instructions.

2

.

Cleaning  and  maintenance  shall  be  conducted  under  outage.  Electrical  components  such  as  motor, 

switch, and connector shall not be spoiled by water so as to prevent from accidents.
3

.

It

'

s prohibited to wash with water so as to prevent accidents.

4

.

Stove fire shall be extinguished timely

 

when

 

it

 

is

 

not

 

used

do not flambe under the range hood and it

'

prohibited  to  bake  food  under  range  hood  directly

 

to  prevent  range  hood  from  damaging  and  causing 

accidents. 

5 .

If  the  supply  cord  is  damaged,  it  must  be  replaced  by  the  manufacturer,  its  service  agent  or  similarly   

qualified persons in order to avoid a hazard.
6.Accessible parts may become hot when used with cooking appliances.


background image

9

Removal of light

Raise the spotlight outward forcibly to remove it from 

the hood. Pull out the connector to replace the spotlight.

Insert a small flat head screwdriver or something

sharp in the gap between the light cover and hood. 

Insert a small flat head screwdriver or something 

sharp in the gap between the light cover and hood.

Removal of

 

A817 light

Removal of A815

 

light

  

Range Hood

Notice

Removal of Components

The hood shall be cleaned and maintained regularly depending on the surroundings, so as to keep its cleanness 

& efficiency and extend its service life. We recommend that: 

Clean the exhaust fume collecting hood and hood body after each cooking. 

To ensure smooth discharge of fumes, the filter screen shall be cleaned regularly according to actual situations. 

Be careful to avoid damage when cleaning.

It is recommended to use a neutral detergent to clean instead of strong detergents, and dry with a soft cloth, and 

should avoid the contact between detergent and control buttons.

Do not allow stains to stay on the surface of the hood for too long.

Please do not use cleaning balls, brushes and other rough objects to clean the hood to prevent the body surface 

from scratching. 

When cleaning or maintaining the hood, please wear protective gloves to prevent 

wounding during wiping. 

Please check and clean the oil cup at regular basis. When the oil reaches above 2/3 

of the cup, rotate the cup rightwards with a hand to toss away the oil, as shown in right. 

Do not touch the light bulb that has been turned on or just been turned off to avoid burns.

Please unplug it during long-term shutdown, but please do not pull hard.

1.The  machine  body  needs  not  to  be  disassembled  in  ordinary  conditions.  Disassembly  shall  be  operated  by 

professional serviceman.

2. The electricity must be cut off before clean, installation or maintenance of range hood. 

Note: The installation procedures are in reverse with the removal. Please wear protective gloves during operation 

to prevent the sharp edge of metal from hurting your hands.  

Warning

Raise the spotlight outward forcibly to remove it from 

the hood. Pull out the connector to replace the spotlight.


background image

Note:

 

In case of installing the filer mesh, face the side with screw holes inwards. 

Removal of filter mesh

Align  the  cross  screwdriver  with  the  screw  hole  and 
raise it upward forcibly meanwhile rotating it counter- 

clockwise about 120

°

,so as to remove the screw out 

of the cross slot of the exhaust fume collecting hood. 
Hold  the  bottom  of  the  mesh  with  one  hand,  and 
remove  the  screw  on  the  other  side  with  the  other 
hand by the cross screwdriver. 

Hold  the  two  screws  on  the  filter  mesh  with  both 
hands  and  pull  it  down  to  detach  the  two  prongs 
inside from the filer mesh. Then pull the filter out as 

per

 

the

 

arrow

 

direction

 

to

 

remove

 

it

Note:

 

Installation steps of the lights and switches 

are opposite to the removal steps. 

CX W- 20 0- 83 01

CX W- 20 0- 83 01

8321

CX W- 20 0- 83 01

CX W- 20 0- 83 01

CX W- 20 0- 83 01

8321

Removal of switch

Switch 

Removal of A817

 

switch

Removal steps
1. Pull out the plug

;

2. Unscrew the four screws from the back of the main hood panel. Tilt the panel forward to a certain angle, and
 then pull it up forcibly

;

3. Remove

 

the

 

drawing

 

panel

 

from

 

the

 

main

 

hood

 

panel

;

4. Use a cross screwdriver to unscrew the fastening screws on the cover to remove the cover

;

5. Unscrew the fastening screws on the retaining ring to remove the retaining ring

;

6. Unscrew the cap clockwise and take out the impeller vertically

;

7. Remove the oil cup and the filter mesh by means of removing the fastening screws with a cross screwdriver. 
Installation steps are opposite to the removal steps. 

(

When

 

you

 

install

 

the

 

impeller

please

 

add some lubricating oil on the shaft hole of it. 

Note:

 

Step 3 is unnecessary if no drawing panel is installed.

Removal steps of the whole range

 

hood

1 0

  

Range Hood

Removal of A815 switch

After removing the spotlight, remove the two screws 
on the switch with a cross screwdriver and move the 
switch  assembly  diagonally  upward  to  take  it  out 
from the lamp hole for repair and replacement. 

Untighten  two  screws  on  the  small  plate  to  remove 
the plate.

Remove  the  two  screws  on  the  switch  cover  plate 
and then rotate the cover plate to pull out the switch 
assembly for maintenance and replacement.


background image

1 1

Air passage

Electric motor

Housing

Mai n hood panel

Dr awi ng panel

Oil cup

Retaining ring

Impeller

Cap

Cover pla te

Filter mesh

Filter screen

Switch

Top cover plate

A81 7

Circuit diagram

220-240V-

LED

L
N

F

u

n

c

ti

o

n

 c

ir

c

u

it

C

K4

K3

K2

K1

A817 

 

Circuit

 

Diagram

M

XP

  

Range Hood

yellow

orange
gray

black
blue

blue

red

Yellow/Green

blue

red

brown

brown
blue

Yellow/Green

 

E

Terminal box

Control circuit


background image

220-240V-

L
N

EL

EL

C

K4

K3

K2

K1

1 2

M

X P

  

Range Hood

A815 

 

Circuit

 

Diagram

Yellow/Green

blue

red

yellow

gray

black
blue
brown

brown
blue

Yellow/Green

 

E

F

u

n

c

ti

o

n

 c

ir

c

u

it

Terminal box

Control circuit

orange

blue

red

blue

red

Troubleshooting of General faults

The light is damaged or poorly 

connected. 

The impeller is loose, and the cap 

is not tightened.

The power socket is not 

grounded well. 

Cause

No response after pressing any button

(e.g. the impeller does not rotate, or 

the light is off)

Pressing the light switch, the light is 

not lit.

Induced current exists on the hood 

body may paralyze hands

Abnormal sound during impeller 

running

Fault

No

.

1

2

3

4

 No oil in the oil cup after a period of time The body is tilt

5

Warning

The power plug is not connected 

properly or there is power failure

1. When connecting or 

replacing the plug, please 

unplug the power plug. 

2. If the range hood's 

power cords are damaged, 

it must be replaced by our 

company's professional 

maintenance staff.

3. The flame is strictly 

prohibited being sucked 

into the machine in case 

of the accidents.  


background image

: