REGIS T-X-B – ACCESS or TIME AND 
ATTENDANCE CONTROLLER 

 
The Regis is a controller with built-in proximity card reader and 7” 
LCD capacitive touch screen display. It is designed for residential 
and business buildings, offices, shops, etc. The controller can have 
125kHz or 13.56MHz reading frequency. 
The entire set-up procedure is carried out with the software. The 
controller allows access for up to 30000 users and saves 100000 
events. If you bought the controller in time and attendance kit, 
then inputs and outputs cannot be controlled. 
It can also be used as a Wiegand 26-bit reader, if needed. 
The SDK is also available for this controller. If a user or software 
producer wants to develop its own application, please contact us.  

 
TECHNICAL DATA 

REGIS T-X-B 

REGIS T-1-B reading frequency 

125kHz 

REGIS T-1-B reading distance 

Up to 15cm 

REGIS T-1-B current consumption in 
standby mode 

300mA 

REGIS T-1-B reading field in vertical 
position 

Bottom side of  
the controller 

REGIS T-1-B reading field in horizontal 
position 

Right side of the 
controller 

REGIS T-3-B reading frequency 

13.56MHz 

REGIS T-3-B reading distance 

Up to 7cm 

REGIS T-3-B current consumption in 
standby mode 

330mA 

REGIS T-3-B reading field in vertical 
position 

Bottom side of  
the controller 

REGIS T-3-B reading field in horizontal 
position 

Right side of the 
controller 

Dimensions (mm)  

210x150x35

 

 (WxHxD) 

Protection 

IP21 

Operating voltage 

From 9V to 14V DC 

Operating temperature 

From -20°C to 60°C 

Connector 

2x 8pin, 1x ethernet 

Display 

TFT - capacitive touch 

Tamper 

Accelerometer   

Display resolution 

1024 x 600 

Humidity 

10-80%, non condensing 

Memory  

30000 cards or codes 
100000 events 

Inputs 

Door status  
Push button 

Outputs 

Transistor output for el. strike 
0.5A  

Clock 

Real time clock, battery backup 
(max. ten hours) 

Communication 

RS485 
Ethernet 

Keypad 

Configurable buttons 
Selectable colors 

*if Regis T is in Spider mode, the same data applies 

 
 
 
 
 

 
Power supply 

The controller need’s external power supply to operate. The Spider 
W40 power supply is sufficient to power two controllers and two 
12V electric strikes or two 12V magnetic locks (0.5A). If you will 
use it as a standalone controller and low consumption electric 
strike (0.25A) you can use power supply Spider W5.  

 
Voltage drops and cable signal interferences

 

When you connect the controller, use cable with a diameter of at 
least 0.22mm

2

. If the cable length exceeds 25m, use one twisted 

pair of UTP cables for the positive (+) pole and one for the 
negative (-) pole. The cable length between power supply and the 
controller should not exceed 50m. 
Take into consideration that a 0.22mm

2

 cable has a resistance of 

approximately 9 ohm per 100m. The power supply at the end of 
cable should be a minimum of 9V. If you are using el. strike, it is 
highly recommended that the voltage drop is calculated. At greater 
distances, a thicker cable of 0.5mm

2

 or more should be used 

wherever possible. 
If the load is, for example, 0.5A (with el. strike) then, on the 
0.22mm

2

 cable voltage drop will be 4.5V at 100m. For the device 

with 60mA consumption, the voltage drop is 0.5V. 
 
Reading distance depends on where the controller is installed. The 
presence of metal or interferences can significantly reduce the 
reading distance.

 DO NOT 

install the controller directly on metal 

surfaces and/or cover it with a metal cover. 
It is 

not recommended

 to install controllers closer than 

30cm

 

from each other in any direction. Otherwise, it may result in 
inaccurate readings or, indeed, in the controller

 not reading at 

all

 

For the Regis T-3-B to comply with EMC directives (CE), you 
have to put ferrite core on the cable as close to the 
controller as possible, making two turns! 

 
 

CONNECTOR DESCRIPTION 

Connectors are marked on the housing 
with 1 in 2. First contact on both 
connectors starts on the marked side (1 
and 2) 

 
 

 
 

 

 

CONNECTOR 1 – connection of power supply, el. strike...  

Contact 

Description 

Specification 

1  

9-14V DC 

Power supply 

2  

GND 

Ground 

3  

El. strike output 

Max. 0,5A 
Active = GND 

4  

Alarm output 

Max. 0,5A 
Active = GND 

5  

Door status switch input 

Active = GND 

6  

Push button input  

Active = GND 

7  

CA 

RS485 A line 

8  

CB 

RS485 B line 

 
CONNECTOR 2 – connection of external reader  

Contact 

Description 

Specification 

1  

9-14V DC 

Power supply 

2  

GND 

Ground 

3  

Data 0 

Wiegand protocol 

4  

Data 1 

Wiegand protocol 

5  

Buzzer output 

Active = GND 

6  

LED output  

Active = GND 

7  

XA – for protocol reader 

RS485 XA line 

8  

XB – for protocol reader 

RS485 XB line 

 

 


background image

REGIS T-X-B – Access or time and attendance controller

 

 

 

 

 

10/2016 

Black line 

www.jantar.si 

 
Inputs, outputs and environment 

Inputs: 

Inputs are realized with opto-isolators. The input is active, when 
pulled to ground with an open collector transistor or mechanical 
switch, which is connecting the input pin of the controller to the 
Ground. 

 
Outputs: 

Output has a pre-installed protection diode for an inductive load. It 
is also protected from current overload. The best way is to use a 
0.25A el. strike or a 0.5A el. magnet, which has to be connected to 
the same positive pole (+) as the controller. Connect the negative 
pole (-) to the door strike output (wire 3). When the output is 
active it is pulled to ground. This can be changed with function 5 – 
negate output (for el. magnet). 

 
Environment:

 

Do not install the controller on/in a place, where it can come in 
contact with water. You must assure good cable joints, protected 
against moisture, otherwise corrosion may damage the controller. 
Damage in such cases is not covered by the warranty.  
 

Regis T-1-B reading range: 

The controller has a program algorithm that, at power start, sets 
parameters based on the installation environment, so as to ensure 
an optimal reading range. 

DO NOT 

install the controller directly on 

metal surfaces and/or cover it with a metal cover; it may stop 
working/reading. If you plan to test the controller and move it onto 
different surfaces, then you have to reset it (power off/on) on each 
surface. 

 

Regis T-1-B reading field: 

The controller has a reading card field active over 1/3 of the 
controller.   
If the controller is in vertical position the reading field is on the 
bottom side of the controller. 
If the controller is in horizontal position the reading field is on the 
right side of the controller. 

 

 

ACCESS OR TIME AND ATTENDANCE 
CONTROLLER 

 

Access controller 

As an access controller, it is intended for controlling entries, exits 
and passes of users in the system and controlling sliding doors, 
ramp, el. strike, turning alarm on/off…  It needs to be set with V7 
or CODEKS software.  

 
Time and attendance controller 

As a time and attendance controller, it is intended to register the 
employee’s arrivals and exits from work, lunch break, private and 
business exits, sick leave... It needs to be set with V7 or CODEKS 
software. In software you need to choose option “Time and 
attendance” for controller and reader. Set the software according 
to your requirements (time tables, users...) and send the tables. 
The keypad will serve for choosing different time intervals (private, 
business…). 

 
The controller switches to access or time and attendance 
controller when tables are sent by the software or when it is 
set to mode 4 with function 9. Change the controller’s 
address from 255 to any number between 1 and 254. If you 
have more controllers on the communication line, don’t 
duplicate addresses. Add them one by one on the 
communication line, because every controller has address 
255 by default. 

 

 

 
 
 
 

 
Communication  

Ethernet: 

Connect the controller to the computer through your LAN via 
Ethernet connector. Use at least UTP CAT 5e cable. Adjust network 
settings of the controller using the Codeks Device Manager 
software so that it will function properly in your network. Please 
consult Codeks Device Manager manual. 

 
S - Spider mode  

In the Spider mode the controller can be used as a communication 
converter, from which you can continue RS485 communication line 
to the other controllers. When the controller is reset to the factory 
settings (brainwash), the controller address is set to 254. 

 
RS485: 

Connect the controller to the computer, with one of the power 
supplies, with communication converter, from the Spider family: 
Spider W5-USB, Spider W5-NET, Spider W40+NET.  
 
The RS485 communication bus is used between the controllers and 
Jantar software. Up to 128 controllers can be lined up into one 
communication line. The maximum length of the communication 
line is 1000 cable meters. It is recommended that you use an FTP 
or S-FTP cable. Only a serial connection of controllers in a single 
communication line is allowed. 

Star (parallel) connection is not 

allowed

.  

All shields of S-FTP cables must be wired together and at 

one 

point

 connected to the earth. Individual connections to the earth 

are not allowed. Do not connect the shield of the cable to the 
ground of the controller. 

 
Reset to the factory settings (brainwash): 

When the controller is reset to the factory settings (brainwash), the 
controller address is set to 254.

 

 

 

ORDERING CODES 

REGIS

 [box]-[card]-[software]  

Box:  

T

 

Card:  

– reading frequency 125kHz (cards)  

– reading frequency 13.56MHz (cards)  

Model:   

B

 – Black line

 

 

 

Code 

Description 

REGIS T-1-B 

Standalone or access controller in 

T

 box, 

Frequency 125kHz, for CODEKS software, 
Integrated Ethernet 

REGIS T-3-B 

Standalone or access controller in 

T

 box, 

Frequency 13.56MHz, for CODEKS software, 
Integrated Ethernet 

 
 

OTHER 

Warranty only applies when the controller Regis is used with power 
supply or/and communication converter from the Spider family. 
 
Please read through our warranty and disclaimer statements. 

 

Connection scheme and additional support for the use of this 
product can be found on: 

http://www.jantar.si/forum/en

 

 