PDF User Manual

  1. Home
  2. Manuals
  3. Q4 audio DPI 10 User Manual

Q4 audio DPI 10 User Manual

DPI 15 DPI 20 DPI 30 DPI 40

Made by: Q4 audio
Type: User Manual
Category: Amplifier
Pages: 15
Size: 0.93 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

DPI Series

User manual

Prelimenary

Professional Power Amplifiers

R

DPI 10

2 x    300 W

DPI 15

 

2 x    500 W

DPI 20

2 x    800 W

DPI 30

2 x 1.100 W

DPI 40

2 x 1.500 W

 


background image

DPI SERIES USER MANUAL

Introduction

Thank  you for choosing the Q4audio DPI series for your ap-

plication.  You have made an excellent choice.  DPI series is part 

of a new breed of power amplifiers using our proprietary switching 

output stage, also called class D (CLD) topology.

The  rugged  steel  chassis  and  conventional  power  supply  

based on a low flux toroïdal transformer make it a perfect match 

for applications where portability is not a premium requirement.   

DPI incorporates unique features that require some study be-

fore being applied.  One of these features is the EFL® (Extended 

Feedback Loop) remote sensing technique.  If you intend to use 

this feature read the section on this subject carefully.

 

 

Summit Engineering nv

Q4audio division

Tongersesteenweg 90

3800 Sint Truiden

Belgium

tel: +32  69 42 59

fax: +32  69 45 92

www.Q4audio.com

email: info@Q4audio.com

SEPN: 7000-0006

Rev.  

Q4audio is a registered trademark of Summit Engineering nv

All other trademarks are property of their respective owners

 


background image

DPI SERIES USER MANUAL

2

Table of contents

Introduction ...............................................................................................................................................................................................

. Safety Symbols.....................................................................................................................................................................................3

2. Safety Instructions ................................................................................................................................................................................4

3. DPI series Features ..............................................................................................................................................................................4

4. Setting up the amplifier

 .........................................................................................................................................................................5

4. Unpacking the unit  ..................................................................................................................................................................5

4.2 Attaching / removing the fancover ........................................................................................................................................... 5

5. Connecting the amplifier

 .......................................................................................................................................................................6

5. Familiarisation with the rear panel .......................................................................................................................................... 6

5.2 Configuartion (dipswitch setting)

 ............................................................................................................................................. 6

5.3. Input connections ...................................................................................................................................................... 7

5.3.3 Speaker connections ................................................................................................................................................ 7

5.3 Connections ............................................................................................................................................................................7

5.3.2 PIM-SIM module ..................................................................................................................................................... 7

5.3.4 Mains connection ...................................................................................................................................................... 8

6. Operation ..............................................................................................................................................................................................9

7. Grounding ...........................................................................................................................................................................................0

8. Specifications

 ..................................................................................................................................................................................... 

9. Dimensions .........................................................................................................................................................................................2

0. Warranty                                                                                ............................................................................................................ 3

Service request form ..............................................................................................................................................................................4

 


background image

DPI SERIES USER MANUAL

3

Explanation of grahical symbols:

This symbol is intended to alert the user of pres-

ence  of  uninsulated  dangerous  voltage  within 

the products enclosure that may be of sufficient 

magnitude to constitute risk of electric shock to 

persons.

This symbol is intended to alert the user on the 

presence  of  important  operating  and  mainte-

nance  (servicing)  instructions  in  the  literature 

accompanying the appliance.

Explication des symboles graphiques:

Ce symbole doit alerter l’utilisateur du danger 

provenant  d’un  voltage  dangereux  et  non 

protégé à l’intérieur de l’appareil, voltage suf-

fisamment fort pour représenter un danger réel 

d’électrocution.

Ce symbole doit attirer l’attention de l’utilisateur 

sur les instructions importantes qui concernent le 

service et la maintenance et qui accompagnent 

tout appareil.

Erklärung der Bildsymbole:

Dieses  Symbol  warnt  den  Benutzer  vor  nicht 

isolierter  gefährlicher  Spannung  im  Inneren 

des Gerätes.  Diese Spannung ist hoch genug 

um  Personen  durch  elektrischen  Schlag  zu 

gefährden.

Dieses Symbol weist den Benutzer auf wichtige 

Bedienungs- und Wartungsanweisungen hin die 

in den gerätebegleitenden Unterlagen aufgeführt 

werden.

Note:

  This equipment  has been tested and found  to comply  with EN55103-1and EN55103-2  product specifications.  These product 

specifications are designed to provide a reasonable protection against harmful interference.  This equipment generates, uses and can 

radiate radio frequency energy and, if not installed and used in accordance with instructions, can cause harmful interference.  There is 

no guarantee that interference will not occur in a specific installation.  If harmful interference is detected try and correct it by one of the 

following measures:

• 

Increase the separation between the equipment.

• 

Connect the equipment to different mains outlets.

• 

Reroute cables.

1. Safety Symbols

CAUTION: 

To  reduce  the  risk  of  electric  shoc,  do  not  open.  

No user-serviceable parts inside.  Refer servicing to qualified 

personnel.

WARNING:  

To prevent fire or electric shoc, do not expose this 

equipment to rain or moisture.

ATTENTION:   

Pour  éviter  les  risques  de  choc  électrique,  ne 

pas  ouvrir.    Cet  appareil  ne  comporte  aucune  pièce  pouvant 

être réparée par l’utilisateur.  Confier l’entretien à un technicien 

qualifié.

AVERTISSEMENT:  

Pour éviter les risques de choc électrique 

ou d’incendie, n’exposez cet appareil ni à l’humidité ni à l’eau 

(pluie...). 

  

ACHTUNG:   

Um  Gefährdung  durch  elektrischen  Schlag  zu 

vermeiden darf das Gerät nicht geöffnet werden.  Es befinden 

sich  keine  vom  Benutzer  reparierbaren Teile  im  inneren  des 

Gerätes.Jegliche Reparatur soll einem qualifizierten Fachmann 

uberlassen werden.

WARNUNG:  

Um die Gefahr eines Feuers bzw. eine Verletzung 

durch elektrischen Schlag zu vermeiden sollte das Gerät niemals 

Regen oder Feuchtigkeit ausgesetzt werden.

!

!

!

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

!

ATTENTION

RISQUE DE CHOC ELECTRIQUE 

NE PAS OUVRIR

!

ACHTUNG

GEFAR FUR ELEKTRISCHEN 

SCHLAG

GERÄT NICHT ÖFFNEN

!

 


background image

DPI SERIES USER MANUAL

4

2. Safety Instructions

 

All safety and operation instructions must be read before this 

unit is operated.

 

The safety and operating instructions must be retained with 

the unit for future reference.

 

All warnings on the appliance and in this operation manual 

must be strictly followed.

 

This unit must not be used near water - for example, near 

bathtub, washbowl, kitchen sink, laundry tub, in a wet base-

ment, near a swimming pool, etc.

 

This unit  must be placed away from heat sources, such as 

radiators or other heat producing devices.

 

The power supply cord must be routed so that it is not likely 

to be stepped on or pinched by objects placed on or against 

it.

 

The power cord of the unit must be unplugged from the mains 

outlet if the unit is not used for a longer period.

 

Care must be taken that objects do not fall and liquids are not 

spilled into the inside of the unit.

 

Unplug the unit and demand servicing by qualified service 

personnel under any of the following conditions: 

• 

Objects have fallen, or liquid has been spilled into the unit; 

• 

The unit has been exposed to rain; 

• 

The unit does not appear to operate normally or exhibits a 

marked change in performance; 

• 

The unit has fallen, or its chassis got damaged; 

• 

The power cord or power plug are damaged.

 

The user must not attempt to service the unit beyond those 

means described in this operating manual.  All other servicing 

must be referred to qualified personnel.

 

To prevent electric shock do not use the polarised plug with 

an extension cord, receptacle or other mains outlet unless the 

prongs can be fully inserted to prevent contact exposure.  This 

unit is equipped with a single pole disconnect device (fuse) in 

the phase (live) wire.  If an unpolarised mains connection is 

used, the receptacle the unit is connected to must be equipped 

with a two pole disconnect device (fuse) of appropriate rating.  

The dust filter cover on the front of the unit forms an integral 

part of the electrical safety provisions.  Do not use the unit 

without the dust filter cover in place!

 

Precautions should be taken so that the grounding and mains 

polarisation means of the unit are not defeated.

 

Slots and openings in the unit are provided for ventilation.  To 

ensure reliable operation and to prevent overheating of the 

unit, these openings must not be blocked or covered!

 

The fanguard on the front of the unit is an integral part of the 

safety provisions of the DPI amplifier.  Make sure it is correctly 

mounted before connecting the unit to a mains outlet.

3. DPI series Features

DPI series power amplifiers feature:

 

Switching class D output stage.

 

Fully symmetrical, and floating modulator for unsurpassed 

accuracy and cross channel separation.

 

Open input architecture for future expansion.  The stand-

ard input module PIM-SIM provides

 

inputs on Neutrik® 

Combo connectors or Phoenix screw terminals, parallel link 

outputs on XLR-3M for easy routing of multiple amplifiers and 

selectable high pass filters with 30 and 50Hz second order 

high pass filter characteristic.

 

Instant  recovery,  eliminating  stitching  of  the  output  when 

recovering from clipping or overload. 

 

EFL® (Extended Feedback Loop).  This inovating technique 

makes it possible to take the feedback for the amplifier right 

from the loudspeaker terminals, offering unprecedented con-

trol of the loudspeaker, independent on loudspeaker cable 

length.  The amplifier can be used as a conventional amplifier 

without this feature enabled, without any inconveniences.

 

Defeatable clip limiter with selectable response time.

 

Minimum sample frequency  selection.

 

Protection against over-dissipation, open or short circuit and 

HF or DC at the output.

 

Outputs on touch proof Neutrik® Speakon connectors and 

high  current  Phoenix®  screw  terminals.    Speakons  have 

integral sensing inputs for the EFL circuit. 

 

Low flux toroïdal power transformer with thermal sensing.  

The  output  power  of  the  amplifiers  is  reduced  in  case  of 

overheating.

 

Extensive power line filtering for minimal interference.

 

Soft start to minimise current surge on power on.

 

A high efficiency cooling system.  The power transistors are 

mounted  directly  onto  the  heatsink,    eliminating  the  high 

thermal  resistance  of  electrical  insulators.   This  reduces 

component temperatures and extends the life of the power 

components.

 

Temperature proportional speed fans for quiet operation.

 

Front to back air flow.

 

Easy to clean air filter on the front.

 


background image

DPI SERIES USER MANUAL

5

4.1 Unpacking the unit 

4. Setting up the amplifier

DPI amplifiers are packed in a strong cardboard box that pro

-

tects it during transport.  In case you ever need to ship the ampli-

fier again it is best to pack it using the original packaging materials.  

Therefore it is advised to save all packaging materials.

The packaging has been specially studied for low load to the 

environment.  The individual packaging materials can be easily 

separated and recycled.

Please  inspect  the  unit  carefully  for  any  signs  of  damage 

incurred  during  transport.   This  DPI  amplifier  has  undergone 

stringent quality control inspection and tests at the factory.  It 

left in perfect condition.  If damage is found notify the transport 

company immediately.

It  is  important  to  immediately  mount  the  fanguard  that  is 

included in the box.  It is an integral part of the electrical safety 

provisions of the unit.

When repacking the unit, use the same packing 

arrangement  as  shown  in  the  picture.  Make  sure 

to remove the fanguard. Place it on the side of the 

unit, between the two side buffers.  This protects the 

fanguard during transport.

Warning: Before continuing the installa-

tion of the DPI amplifier, mount the fan

-

guard on the front of the unit.

READY / P

ROTECT

SIGNAL

BRIDGE

CLIP / NLR

CH 2

-dB

CH 1

-dB

TEMP LIM

IT / TCL

SUPPLY O

VL

0

2

4

6

8

10

12

14

0

2

4

6

8

10

12

14

PROFESS

IONAL CLA

SS-D POW

ER AMPLIF

IER

POWER

ON

REMOTE

ACTIVE

CALL

10

EXAMINE

EQUIPME

NT CARE

FULLY FO

R

SHIPPING

DAMAGE

.

IF DAMA

GE IS

FOUND

NOTIFY

THE CA

RRIER

WHO

MADE

DELIVER

Y.

DEMAND

AN

INSPECT

ION AND

A SIGNE

D DAMA

GE

REPORT.
THIS PAC

KAGING

IS MADE

FROM FU

LLY

RECYCL

ABLE

MATERIA

LS.

KEEP

PACKAG

ING FO

R FUTU

RE USE

OR

DISPOSE

OF PROP

ERLY.

DPI S

eries

User

manu

al

Prelim

enary

Profe

ssio

nal P

owe

r Am

plifie

rs

R

DPI 1

0

2 x

300 W

DPI 1

5

2 x

500 W

DPI 2

0

2 x

800 W

DPI 3

0

2 x 1.1

00 W

DPI 4

0

2 x 1.5

00 W

SIG

NA

L

oo

4

6

8

10

12

14

18

24

RE

MO

TE

AC

TIV

E

CA

LL

Place the two tabs of the fanguard in the corresponding holes 

on the right of the unit.  Push the fanguard against the front panel 

and secure it by turning the /4 turn lock 90° clockwise. 

DPI series amplifiers are equipped with two cooling fans with 

front to rear airflow.  When installing the amplifier, allow for ample 

space behind the amplifier to ensure sufficient airflow, especially 

if the amplifier is operated in a rack system.  This avoids thermal 

limiting of the output power or, in severe situations even shut-off 

by the thermal protection system.

The fancover can be easilly removed by turning the /4 turn 

lock 90° counterclockwise and pulling it off the frontpanel, left 

side first.

The standard air filter delivered with the amplifier is a black, 

8mm thick reticulated polyurethane foam with a density of 20PPI.  

The filter can be easilly cleaned by rinsing it with water.  Let it dry 

thouroughly before mounting it back onto the amplifier.

In case you need to replace the filter use only the prescribed 

material and thickness or contact your distributor for a replace-

ment.  

Do  not  use  the  amplifier  without  the  airfilter  in  place.  

Regular cleaning of the filter eliminates dust buildup inside the 

unit. 

  

4.2 Attaching / removing the fancover

!

!

 


background image

DPI SERIES USER MANUAL

6

5. Connecting the amplifier

5.1 Familiarisation with the rear panel

   Channel  output is available on parallel wired Neutrik 4 pole 

Speakon and Phoenix screw terminal.  Wiring of the Speakon 

is as follows:

   

+ = Channel output positive

   

-  = Channel output negative (ground)

   

2+ = Channel sense input positive

   

2-  = Channel sense input negative (ground sense)

2   Bridge output is available on Neutrik 4 pole Speakon.  Another 

possibility to connect the bridge output is to use the Ch and 

Ch2 Phoenix OUT+ terminals.  In this case Ch OUT+ is the 

positive output pole and Ch2 OUT+ the negative.  Wiring is 

as follows:

   

   

+ = Bridge output positive

   

-  = Bridge output negative

   

2+ = Bridge sense input positive

   

2-  = Bridge sense input negative

1

3

4

5

2

6

7

OUT + OUT

SENSE

+

CH1

OUT + OUT

SENSE

CONFIGURATION

+

CH2

W

AR

NI

NG

:R

IS

K

OF

HA

ZA

RD

OU

S

EN

ER

GY

!

MA

KE

PR

OP

ER

SP

EA

KE

R

CO

NN

EC

TIO

NS

-S

EE

OP

ER

AT

IN

G

MA

NU

AL

BE

FO

RE

US

E.

MAINS FUSE

MAINS INPUT

ATTENTION:

RISQUE

D'INCENDIE! REMPLACEZ

UNIQUEMENT PAR UN

FUSIBLE DE MEME TYPE ET

VALEUR - CONSULTEZ LA

PLAQUE DE MARQUAGE.

WARNING:

TO REDUCE THE RISK

OF FIRE OR ELECTRIC SHOCK DO

NOT EXPOSE THIS EQUIPMENT TO

RAIN OR MOISTURE. NO USER

SERVICEABLE PARTS INSIDE. REFER

SERVICING TO QUALIFIED PERSON-

NEL. READ INSTRUCTION MANUAL

CAREFULLYBEFORE USE.

WARNING:

TO REDUCE THE RISK

OF FIRE OR ELECTRIC SHOCK DO

NOT EXPOSE THIS EQUIPMENT TO

RAIN OR MOISTURE. NO USER

SERVICEABLE PARTS INSIDE. REFER

SERVICING TO QUALIFIED PERSON-

NEL. READ INSTRUCTION MANUAL

CAREFULLYBEFORE USE.

CLASS 1 EQUIPMENT

MUST BE EARTHED!

!

AVIS

RISQUE DE CHOC

ELECTRIQUE

NE PAS OUVRIR

CAUTION

RISK OF ELECTRIC

SHOCK

DO NOT OPEN

ATTACH TYPE LABELTO THIS LOCATION. THIS

LABEL CONTAINS IMPORTANT SAFETY

INFORMATIONAND MUST NOT BE REMOVED.

REPLACE LABEL IN CASE IT GOT DAMAGED

OR LOST.

CAUTION:

FIRE HAZARD!

REPLACE ONLY WITH SAME

FUSE TYPEAND RATING - SEE

TYPE LABEL.

CH2 ON/OFF

CH2 SLOW

CH1 ON/OFF

CH1 SLOW

CH1 FSMIN

CH2 FSMIN

BRIDGE

LOCK

LOCK

LOCK

CLIPLIMITER

ON

BRIDGE MODE:

SWITCHES 1 AND

2 ON USE CH1

INPUT AND LEVEL

CONTROL. CH2

INPUT AND LEVEL

BRIDGE MODE:

SWITCHES 1 AND

2 ON USE CH1

INPUT AND LEVEL

CONTROL. CH2

INPUT AND LEVEL

1+

1

2+

2

OUT

SENSE +

SENSE

OUT +

SPEAKON

WIRING

BRIDGE

1 2 3 4 5 6 7 8

Model: DPI 40

Serialnr.: DPI40-01AA-XXXX

Date of manufacture: 28.06.04

Made in Belgium, EU

FUSE: xxx A T / 250 V

Power requirments: 264V AC 50/60Hz 6.000W

8

8

3   Channel 2 output.  For more information see Ch under point 

.

4   Configuration dipswitches.

5   Peripheral Input Module.    DPI series is standard delivered 

with the PIM SIM analog input module.  Do not operate the 

amplifier without the module in place.  The PIM module can be 

easilly exchanged for versions with more elaborate features.

6   Mains power cord.

7   Fuseholder.    Replace  fuse  only  with  same  fuse  type  and           

rating. This information is found on the type label, attached to 

the rear panel. 

8  Ventilation slots.  Never cover the ventilation slots. These en-

sure reliable operation and prevent overheating of the unit.

DPI series amplifiers are able to work in two main operational 

modes that can be selected by the dipswitches (4) on the back 

of the unit.

 

DUAL

 mode: in this mode both channels and their correspond-

ing in- and outputs work totally independent from eachother.  

This is the mode for normal stereo (two-channel) operation.  

In dual mode both switch  and 2 are in their UP position.

BRIDGE

 mode is activated by setting switches   and 2 in 

the ON (down) position.

Bridge mode allows to  use the amplifiers full output capacity 

for one single monaural channel. 

This configuration is recommended to produce high power 

output for a monaural speaker system, e.g. subwoofer.  In ad-

dition to that, any DPI amplifier working in BRIDGE mode can 

be directly connected to an unisolated 00V (70V) constant 

voltage sound system.

FSMIN selection:

  DPI series amplifiers use a variable switch

-

ing frequency modulator.  As the output signal increases in 

amplitude,  the  switching  frequency  of  the  modulator  goes 

5.2 Configuartion (dipswitch setting)

down.  Ultimately the switching  frequency goes to zero when 

the amplifier runs into the supply rails.  To avoid this and to 

minimise stitching of the output signal after such event, the 

modulator  continuously  monitors  the  switching  frequency 

and  clips  the modulator  input  signal  in  case  the switching 

frequency drops below a predefined value.  This value can be 

adjusted by the dipswitches 3  and 4 resp. for CH1 and CH2.  

Switch in the UP position corresponds to 35kHz.  Switch in 

the down position to 70kHz.  It is almost impossible to hear 

any difference between both settings.  We advise the 70kHz 

position for critical listening.  The output power will be a few 

percent lower when FSMIN 70kHz is enabled, compared to 

the 35kHz setting.

The 

CLIP LIMITER 

avoids gross clipping of the output signal 

in case the FSMIN clipper is activated.  Gain is automatically 

reduced if the limiter is activated by putting switches 6 (CH2)  

and 8 (CH1) in the ON (down) position.  Attack and release 

times can be adjusted with switches 5 (CH2) and 7 (CH1).  

Reaction of the limiter circuit is slowed down by putting these 

switches in their ON (down) position.  

 


background image

DPI SERIES USER MANUAL

7

The DPI series amplifiers have an open input architecture 

for future expansion.  Standard, the amplifier is equipped with 

the PIM-SIM module.

5.3.2 PIM-SIM1 module

.  Channel  input sockets are mixed XLR/phone jack recepta-

cles, which allow the use of microphone or instrument cables 

to connect the amplifier.  Whenever possible, use 2-conductor 

shielded cable for a balanced signal transmission.  This gives 

the best results and the lowest noise.  The inputs are wired in 

standard configuration with pin 1 as  ground, pin 2 as signal 

“hot” and pin 3 as signal “cold”.

  Refer  to  the  input  wiring  diagram  on  the  amplifier’s  back 

panel.

  Each  input  XLR/Phone  jack  is  parallel  wired  to  a  Phoenix 

screw terminal for easy connections as well as to a ‘Direct Out’ 

male XLR socket to provide easy linking to other amplifiers.

2.  Channel 2 input.  See Ch information under point .

All  input  and  output  sockets  are  on  the  rear  panel  of  the 

amplifier. The rear panel also holds the mains cord (8) and the 

fuse holder (9).  For maximum safety, it is recommended to stick 

to the order given below when wiring the PA system.

5.3 Connections

5.3.1 Input connections

3.  Configuration  dipswitches  for  parallel  mode  and  high  pass 

filter.

Switches 1 and 2 make it possible to parallel CH1 and CH2 

inputs.  Put switches in the ON (down) position to wire CH1 and 

CH2 inputs in parallel.  Use CH1 or CH2 input.  The output lev

-

els can be adjusted individually by means of the corresponding 

level controls.

Switch 3 makes it possible to insert a 50Hz second order high 

pass filter into CH1 signal path.  Put the switch in the ON (down) 

position to activate the filter.

Switch 4 controls CH1 high pass filter frequency.  With the 

switch in the up position the cutoff frequency is 50Hz.  The down 

position changes this to 30Hz.

Switch 5 controls CH2 high pass filter mode and switch 6 

controls CH2 high pass filter cutoff frequency.  Functioning is 

the same as for CH1.

Warning: All DPI series amplifiers are capable of producing 

dangerously  high  voltages  at  the  output  terminals!   To  avoid 

cable overheating, do not use speaker cables under .5 mm2 

cross-section (AWG 5). The use of thicker cables helps to keep 

power loss down and damping high, especially if long  distances 

have to be bridged.  After insertion, twist each speakon connector 

clockwise until latching or lock it with the swivell nut to ensure 

proper contact.

DUAL

 mode: use the SPEAKER OUT  and 2 outputs to con-

nect the speaker systems. Minimum total speaker impedance 

per channel is 2 O hms.

BRIDGE

 mode: BRIDGED OUT speaker connection is done 

by using standard Speakon cables.  Minimum total speaker 

impedance is 4 Ohms.

5.3.3 Speaker connections

 

EFL® (Extended Feedback Loop).

  

This inovating feature makes it possible to take the feed-

back for the amplifier right from the loudspeaker terminals, of

-

fering unprecedented control of the loudspeaker, independent 

on loudspeaker cable length.  The amplifier can be used as a 

conventional amplifier without this feature enabled, without any 

inconveniences by simply not connecting the sense terminals. In 

this case feedback is taken right at the speaker output terminals, 

compensating any internal wiring, yielding very high low output 

impedance.  

The sense inputs give access to highly sensitive 

electronic components inside the unit.

Although the amplifier is protected against mis

-

wiring of the sense inputs, these components  

are not resistant to continuous fault situations.

+

CH1

INPUT

INPUT

LINK / OUT

+

CH2

INPUT

LINK / OUT

GND

1

2

3

SLEEVE

TIP

RING

GND

+

-

PA

RA

LL

EL

IN

PU

TS

CH

1H

P

FI

LT

ER

(O

N/

OF

F)

CH

2H

P

FI

LT

ER

(O

N/

OF

F)

CH

1H

P

FR

EQ

.5

0H

z

30

Hz

INPUT

1

2 3

ON

CONFIGURATION

INPUT IMPEDANCE: 20K BALANCED

10K UNBALANCED

M

OD

UL

E:

SI

M

-1

1 2 3 4 5 6

CH

2H

P

FR

EQ

.5

0H

z

30

Hz

1

3

2

OUT + OUT

SENSE

+

CH1

OUT + OUT

SENSE

+

CH2

W

AR

NI

NG

:

RI

SK

OF

HA

ZA

RD

OU

S

EN

ER

GY

!

MA

KE

PR

OP

ER

SP

EA

KE

R

CO

NN

EC

TIO

NS

-S

EE

OP

ER

AT

IN

G

MA

NU

AL

BE

FO

RE

US

E.

LOCK

LOCK

LOCK

1+

1

2+

2

OUT

SENSE +

SENSE

OUT +

SPEAKON

WIRING

BRIDGE

Pin configurations

The  pin  configurations  for  the  three  speaker  connectors 

are  printed  on  the  amplifier’s  back  panel.  Before  connecting 

the speakers, make sure that your speaker cables are properly 

wired.

Warning: this mode does not mean that the out-

puts of both channels can be wired in parallel. 

Never attempt to wire them together!  This can 

damage the amplifier.

!

!

 


background image

DPI SERIES USER MANUAL

8

OUT + OUT

SENSE

+

OUT + OUT

SENSE

+

5.3.4 Mains connection

For mains connection, use only three-prong mains connectors 

with earth contact.  Switching the amplifier to different voltage 

systems is done from the inside and should only be performed 

by a qualified technician.

The mains cable conductors have the following color code:

 

YELLOW/GREEN = earth (PE)

 

BROWN = live (L)

 

BLUE = neutral (N)

Output cabling for dual (stereo) / parallel (mono) mode:

      Preferred                             Second option

In  case  the  sense  inputs  are  not  used  leave 

them  unconnected.  The  amplifier  will  then 

function as a conventional amplifier.  

Extra care is needed in case of 4 core cables 

to  make  sure  the  sense  wires  are  not  con

-

nected.

In case the sense inputs are used, try the con

-

nection with a low level signal at the output.  If 

the channel goes into protect mode check the 

wiring for accordance with the figures below.

Continuous operation into a faulty wiring can 

 


background image

DPI SERIES USER MANUAL

9

Each channel is controlled from the front panel by a level con-

trol potentiometer and 4 status LED’s.  The status LED’s indicate 

the following operational states of the amplifier:

READY/PROTECT:

 two-coloured LED indicates whether or 

not the channel  is ready to operate.  Lights up green when the 

amplifier is working normally, and turns red whenever  there is a 

malfunction, e.g. DC voltage at the output, output stage defect, or 

heatsink temperature exceeding 90°C.  After turning the amplifier 

on, this LED will remain red for about 2 seconds until the internal 

supply voltages have set to their normal values.

SIGNAL:

 indicates signal presence at the channel’s output.  

Threshold level is +0 dBV.

VOLT CLIP / LIMIT:

 lights when the amplifier has reached 

the minimum switching frequency.  This is equivalent to clipping 

in a normal power amplifier.  In case the internal clip limiter is 

activated, the gain will be automatically reduced to prevent the 

occurrence of gross nonlinearity conditions inside the amplifier.

The clip limiter keeps signal distortion under 5% and thus 

guarantees a clean sound and effective speaker protection.

TCL  (Temerature  Controlled  Limiting):

  indicates  signal 

limiting as a result of heat sink over temperature (above 85°C).  

This helps to prevent the triggering of the internal thermal shut-off 

circuit, which would step in at 90°C heat sink temperature as a 

final safeguarding measure.

The temp limit only becomes active when the regular cool-

ing  mechanism  fails  to  work  properly,  e.g.  by  a  dirty  air  filter,  

obstructed air-flow...

 A lit TCL LED should always be taken as a sign to check the 

air filter and to assure sufficient cooling air supply.

Further 3 leds give operational information of the unit:

BRIDGE:

 Indicates the amplifier is configured for bridge mode 

operation.  Use CH1 level control as indicated.

SUPPLY OVL:

 Indicates a power supply overload.  If this LED 

is lit, gain of both channels is decreased simultaneously to avoid 

overheating of the unit’s power transformer.

REMOTE:

  Both the ‘ACTIVE’ LED as the CALL button are 

functions which require an optional remote module to be inserted 

at the back of the unit.  Further explanation of the functions will 

accompany the remote module.  This function is not available 

with the PIM-SIM standard input module.

6. Operation

READY / PROTECT

SIGNAL

BRIDGE

VOLT CLIP / LIMIT

CH 2

-dB

CH 1

-dB

TEMP LIMIT

SUPPLY OVL

0

oo

2

4

6

8

10

12

14

18

24

0

oo

2

4

6

8

10

12

14

18

24

 


background image

DPI SERIES USER MANUAL

0

For maximum performance we recommend the use of two 

conductor shielded cable for making input connections.  Because 

the shield does not carry audio signal, interference between signal 

current and audio current is minimised in this way.   While wiring up 

your system take following important points into consideration:

. Never use a ground lift adapter on the mains feed.  The 

isolation system of this product takes into account that the chas-

sis is connected to earth at all times.  This product will become 

unsafe if the chassis is disconnected from earth.

 2. Most installations  use a mix of balanced and unbalanced 

connections with a variety of equipment being connected.  In 

case you experience a hum or buzz problem, do not be afraid 

to experiment.

Pin  of the input connectors (and direct out connectors) is 

connected to chassis ground.  In a perfect world it would be pos-

sible to simply connect the sleeves of the signal cables to pin  

at both ends of the cable.  This would in effect make the cable 

screen an extension of the chassis between the two intercon-

nected pieces of equipment and provide for perfect LF and HF 

screening of the audio signals.

Problem however is that some equipment use badly organised 

internal grounding and will generate hum and buzz because of 

earth currents flowing through the internal signal ground.  In such 

case it is necessary to stop the earth currents from flowing by 

disconnecting pin  from the sleeve.

Use the figures below as a guidance to solve problems with 

hum or buzz.          

7. Grounding

Source

Output

Amplifier

Input

2-wire mains cord

Floating

Balanced

Source

Output

Amplifier

Input

3-wire mains cord

Grounded

Source

Output

Amplifier

Input

2-wire mains cord

Floating

Unbalanced

3-wire mains cord

Source

Output

Amplifier

Input

Grounded

 


background image

DPI SERIES USER MANUAL

Model  

DPI10  DPI15  DPI20  DPI30  DPI40

 

Min. output power per channel into 2 ohms

 

500 W 

900 W  200 W  600 W  2200 W

1 kHz sine wave, THD < 1%, both channels driven

Min. output power per channel into 4 ohms

 

300 W 

500 W 

800 W  00 W  500 W

1 kHz sine wave, THD < 1%, both channels driven

Min. output power per channel into 8 ohms

 

200 W 

330 W 

450 W 

600 W 

800 W

1 kHz sine wave, THD < 1%, both channels driven

Min. output power in bridge mode into 4 ohms

 

000 W  800W  2400 W  3200 W  4400 W

1 kHz sine wave, THD < 1%

Min. output power in bridge mode into 8 ohms

 

600 W  000 W  600 W  2200 W  3000 W

1 kHz sine wave, THD < 1%

Typical THD+N

 

 

 

< 0.02 %

1 KHz -3dB output power

SMPTE intermodulation distortion

 

 

 

< 0.05 %

60 Hz - 7 KHz 4:1 at -3dB output power

Dynamic intermodulation distortion

 

 

 

< 0.05 %

30 KHz bandwidth at -3dB output power

Frequency range

 

 

  + 0 dB / - 0.8 dB

20 Hz - 20 kHz at nom. output power

Small Signal Frequency response

 

 

 

5 Hz - 50 kHz 

 -3dB; Load impedance 2 - 6 Ohms

Large Signal Bandwidth

 

 

 

35 kHz

Rise time

 

 

 

< 10 µs 

Damping factor

 

 

  > 3000 (EFL used)

1 KHz referred to 8 ohms

Voltage gain

 

 

 

+36 dB

Level controls full cw

Noise interference

 

 

 

< -105 dB 

22 Hz - 22 KHz rms A weighted, referred to nom. output power

Crosstalk

 

 

 

< -70 dB

1 KHz / 8 ohms 

Input CMRR

 

 

 

> 80 dB

100 Hz 

Output DC offset voltage

 

 

 

< ±25 mV

Input impedance

  

0 Kohms unbalanced / 20 Kohms balanced

Input connectors

 

/4” phone jack / XLR compound receptacle, parallel XLR male 

 

parallelled Phoenix® screw terminals

Output connectors

 

 x 4-pole Speakon per channel /  x 4-pole Speakon for bridge 

 

parallelled Phoenix® 4 mm² screw terminals

Cooling

 

Forced cooling with 2 vari-speed fans / front to rear airflow

Mains supply

 

115 V / 230 V ±10% AC 50/60 Hz

Dimensions

 

Width: 482 mm,  Height: 88.9 mm,  Depth: 350 mm

 

(mounting base to connector panel)

Net weight

 

3.5 kg 

5 kg 

6 kg 

8 kg 

20 kg

Shipping weight

 

6.3 kg 

8 kg 

9 kg 

2 kg 

23 kg

Standards

 

 

Safety: EN60065 EMC: EN5503-/EN5503/2/E2/E3

Note: Distortion measurements with AES-17 low pass filter.

8. Specifications

 


background image

DPI SERIES USER MANUAL

2

9. Dimensions

READY / PROTECT

SIGNAL

BRIDGE

VOLT CLIP / LIMIT

CH 2

-dB

CH 1

-dB

TEMP LIMIT

SUPPLY OVL

0

oo

2

4

6

8

10

12

14

18

24

0

oo

2

4

6

8

10

12

14

18

24

PROFESSIONAL POWER AMPLIFIER

POWER

ON

OUT + OUT

SENSE

+

CH1

OUT + OUT

SENSE

CONFIGURATION

+

CH2

W

AR

NI

NG

:

RI

SK

OF

HA

ZA

RD

OU

S

EN

ER

GY

!

MA

KE

PR

OP

ER

SP

EA

KE

R

CO

NN

EC

TI

ON

S

-S

EE

OP

ER

AT

IN

G

MA

NU

AL

BE

FO

RE

US

E.

MAINS FUSE

MAINS INPUT

ATTENTION:

RISQUE

D'INCENDIE! REMPLACEZ

UNIQUEMENT PAR UN

FUSIBLE DE MEME TYPE ET

VALEUR - CONSULTEZ LA

PLAQUE DE MARQUAGE.

WARNING:

TO REDUCE THE RISK

OF FIRE OR ELECTRIC SHOCK DO

NOT EXPOSE THIS EQUIPMENT TO

RAIN OR MOISTURE. NO USER

SERVICEABLE PARTS INSIDE. REFER

SERVICING TO QUALIFIED PERSON-

NEL. READ INSTRUCTION MANUAL

CAREFULLY BEFORE USE.

WARNING:

TO REDUCE THE RISK

OF FIRE OR ELECTRIC SHOCK DO

NOT EXPOSE THIS EQUIPMENT TO

RAIN OR MOISTURE. NO USER

SERVICEABLE PARTS INSIDE. REFER

SERVICING TO QUALIFIED PERSON-

NEL. READ INSTRUCTION MANUAL

CAREFULLY BEFORE USE.

CLASS 1 EQUIPMENT

MUST BE EARTHED!

!

AVIS

RISQUE DE CHOC

ELECTRIQUE

NE PAS OUVRIR

CAUTION

RISK OF ELECTRIC

SHOCK

DO NOT OPEN

ATTACH TYPE LABELTO THIS LOCATION. THIS

LABEL CONTAINS IMPORTANT SAFETY

INFORMATIONAND MUST NOT BE REMOVED.

REPLACE LABEL IN CASE IT GOT DAMAGED

OR LOST.

CAUTION:

FIRE HAZARD!

REPLACE ONLY WITH SAME

FUSE TYPEAND RATING - SEE

TYPE LABEL.

CH2 ON/OFF

CH2 SLOW

CH1 ON/OFF

CH1 SLOW

CH1 FSMIN

CH2 FSMIN

BRIDGE

LOCK

LOCK

LOCK

CLIP LIMITER

ON

BRIDGE MODE:

SWITCHES 1 AND

2 ON USE CH1

INPUT AND LEVEL

CONTROL. CH2

INPUT AND LEVEL

BRIDGE MODE:

SWITCHES 1 AND

2 ON USE CH1

INPUT AND LEVEL

CONTROL. CH2

INPUT AND LEVEL

1+
1

2+
2

OUT

SENSE +
SENSE

OUT +

SPEAKON

WIRING

BRIDGE

1 2 3 4 5 6 7 8

+

CH1

INPUT

INPUT

LINK / OUT

+

CH2

INPUT

LINK / OUT

GND

1

2

3

SLEEVE

TIP

RING

GND

+

-

PA

RA

LL

EL

IN

PU

TS

CH

1H

P

FI

LT

ER

(O

N/

OF

F)

CH

2H

P

FI

LT

ER

(O

N/

OF

F)

CH

1H

P

FR

EQ

.5

0H

z

30

Hz

INPUT

1

2 3

ON

CONFIGURATION

INPUT IMPEDANCE: 20K BALANCED

10K UNBALANCED

MO

DU

LE

:S

IM

-1

1 2 3 4 5 6

CH

2H

P

FR

EQ

.5

0H

z

30

Hz

Model: DPI 40

Serialnr.: DPI40-01AA-0001

Date of manufacture: 28.06.04

Made in Belgium, EU

FUSE: xxx A T / 250 V

Power requirments: 264V AC 50/60Hz 6.000W

3,

50

36

0,

00

37

2,

00

35

7,

00

445,00

482,60

88

,5

0

51

,0

0

 


background image

DPI SERIES USER MANUAL

3

10. Warranty                                                                               

SUMMARY

The Q4AUDIO division of Summit Engineering nv Tongersesteenweg 90 3800 Sint-Truiden Belgium, the creators and manufacturers 

of the Q4AUDIO product line warrants to you, the original purchaser and any subsequent owner of this Q4AUDIO product, for a period 

of 2 (two) years (warranty period) from the date of purchase by the original purchaser that the product is free of defects in components 

and factory workmanship.  The date of purchase is the date appearing on the first end-user’s sales receipt or other proof of original 

purchase from an authorised Q4AUDIO dealer. 

ITEMS EXCLUDED FROM WARRANTY

This Q4AUDIO warranty does not cover product failure caused by misuse, accident or neglect.  Nor shall it be applicable to any product 

on which the serial number has been defaced, altered or removed.  This warranty shall be  considered void if this product is subjected to 

repair work or alteration by persons other than authorised by Q4AUDIO in such a manner as to injure, in the sole judgment of Q4AUDIO, 

the performance, stability, reliability or safety of this product.  This warranty does not apply to finish or appearance items.  This warranty 

is in effect only during the warranty period. 

OUR COMMITMENT

During the warranty period, Q4AUDIO will remedy any defect (except as excluded) by repair or at its option replacement or refund.  In 

case of refund the defective or malfunctioning product shall be made available to us free and clear of all lies or other encumbrances.  The 

refund will be equal to the original purchase price less a reasonable depreciation of 0% per year from the date of purchase.  The refund 

will not include interests, insurance, closing costs, loss of profit or other financial costs that may be the result of the product’s defect.

 

OBTAINING WARRANTY SERVICE

You must notify us of your need for warranty service, preferably by filling out the service request form in this manual and returning it to 

us.  We will give you notice of the authorised service center to whom you may deliver the product or we will give you an authorisation to 

return it to the factory.  All components must be shipped in a factory pack, shipping prepaid.  Repairs and replacement parts provided 

under the terms of this warranty shall carry only the unexpired portion of this warranty. 

DISCLAIMER

 

Q4AUDIO is not liable for any damage to other products such as speakers, amplifiers or any other equipment that is caused by using 

this Q4AUDIO product. 

PRODUCT CHANGES

 

We reserve the right to change the design on any product without prior notice and with no obligation to make corresponding changes 

in products previously manufactured. 

Summit Engineering nv

Q4AUDIO division

Tongersesteenweg 90

3800 Sint-Truiden

Belgium

tel: +32  69.42.59

fax: +32  69.45.92

www.Q4audio.com

email: ebergers@summit-eng.be

 


background image

DPI SERIES USER MANUAL

4

Service request form

Send this service request form together with the unit (do not send separately!) to your authorised 

Q4audio dealer, or to following address:

Summit Engineering NV

Q4audio division

Tongersesteenweg 90

3800 Sint-Truiden    Belgium

Tel:   +32 (0) 69 42 59

Fax: +32 (0) 69 45 92

Email: service@Q4audio.com

Attempts to solve the problem

 ..........................................................................................................................................................  
 ..........................................................................................................................................................  
 ..........................................................................................................................................................  
 ..........................................................................................................................................................  
 ..........................................................................................................................................................

Problem description

          

Be sure to explain the circumstances under which  the problem occurred!

 

 ..........................................................................................................................................................  
 ..........................................................................................................................................................  
 ..........................................................................................................................................................  
 ..........................................................................................................................................................  
 ..........................................................................................................................................................
 ..........................................................................................................................................................  
 ..........................................................................................................................................................
 ..........................................................................................................................................................
 ..........................................................................................................................................................

Product information

Product::  ...........................................................................................................................................  
Serial number:  ..................................................................................................................................  
Purchased from:  ...............................................................................................................................  
Purchase date: ..................................................................................................................................  

Owner information

Name/Company:  ..............................................................................................................................  
Shipping addess:  .............................................................................................................................  
 ..........................................................................................................................................................  
Country:  ...........................................................................................................................................  
Tel: ....................................................................................................................................................  
Fax: ...................................................................................................................................................