OPERATING MANUAL 

 

 

 

 

 

 

   

 

 

 

                                 

     MHS-5200A 
    Dual-channel  
DDS Signal Generator 

 


background image

 

 

  

1

 

Unpacking 

 

      When you get a new MHS-5200A Series dual-channel DDS signal  generator, it 

is recommended that you follow these steps to inspect the instrument.

 

1

Check for transportation damage caused. 

    Such  as  packing  or  bubble  bag  cushions  serious  damage,  keep  them  until  the 

machine and accessories passed the test.

 

2

Check the box in the article are complete. 

  The  package  contents  as  described  below.  If  the  content  does  not  match  or  if  the 

instrument is damaged, contact your dealer or manufacturer. 

 

Host computer

MHS-5200A Series dual-channel DDS signal generator              1 

Accessory

        Power Adapter                                                                              1 

                    USB cable                                                                                      1 

                    Signal connection cable                                                                  2 

                    User Manual (pdf version)                                                              1 

             

   

3. Check the machine

 

    Inspect the instrument is damaged, not working properly, or fails performance tests, 

please contact your dealer or the Company.

 

 

 

 

 

 
 
 
 
 

 


background image

 

 

  

2

 

 

1 .Outline 

1-1

. The    instrument    Introduction 

        MHS-5200A  series  instruments  using  large  scale  integrated  circuits  and 

high-speed  FPGA  MCU  microprocessor,  the  internal  circuit  to  take  surface  mount 

technology  has  greatly  enhanced  the  instrument's  noise  immunity  and  service  life. 

Display  interface  using  LC1602  LCD  display  is  divided  into  two  lines,  the  top  line 

shows  the  current  frequency,  the  following  line  displays  additional  parameters  or 

function variable and flexible use of flip key setting, greatly enhances the operability. 

This instrument signal generation, waveform scanning, as well as the use of parameter 

measurement  has  great  advantages,  is  an  electronic  engineer,  electronic  laboratories, 

production lines and teaching, research and the ideal test, measurement equipment. 

Model Description   

      This  series  of  instruments  in  four  models,  the  main  difference  is  the  maximum 

frequency sine wave, as follows: 

MHS-5200-06M sinusoidal signals at frequencies up to    6MHz 

MHS-5200-12M sinusoidal signals at frequencies up to    12MHz 

MHS-5200-20M sinusoidal signals at frequencies up to    20MHz 

MHS-5200-25M sinusoidal signals at frequencies up to    25MHz 

The instrument characteristics 

1

Direct digital synthesis (DDS) technology, FPGA design, low power consumption; 

2

Dual output, can work in sync phase adjustable

 

3

It has up to 999 seconds of linear and logarithmic sweep function Sweep

 

4

With  a  sine  wave,  triangle  wave,  square  wave,  sawtooth  rise,  falling  sawtooth 

waveform basic function and variable duty cycle pulse wave, but also has 16 sets of 

arbitrary waveform customized by the user; 

5

A total of 10 sets of parameters stored bits have M0 ~ M9, M0 boot automatically 

transferred out of data; 

6

At  12MHz  or  less,  the  sharpest  of  up  to  20Vp-p,  more  than  12MHz,  the  biggest 

reach 15Vp-p; 

 


background image

 

 

  

3

 

7

Built precision -20dB attenuator reach the minimum amplitude resolution 1mV; 

8

With a 120% ~ + 120% DC bias function; 

9

Pulse Duty precise adjustment to 0.1%

 

10

Having four variable phase difference of TTL output

 

11

Having  a  frequency  measurement,  period  measurement,  positive  and  negative 

pulse width measurement, duty cycle measurements and counting function

 

12

Four optional gate frequency measurement time, which strike a balance between 

speed and accuracy

 

13

All parametric equalizer can be done by an internal calibration procedure

 

14

Powerful communications features, completely open communication protocol that 

allows the secondary development of very simple

 

15

After connecting with the PC, the PC can be used to control the instrument, and 

can  be  edited  on  the  PC  arbitrary  waveform  output  waveform  is  downloaded  to  the 

instrument. 

16

This type machine can be equipped with an increase in power module, the signal 

output amplitude reaches 30Vpp, the maximum output current reaches 1A; 

 

Technical indicators

 

Table 1-1 MHS-5200A Series Specifications 

Project

 

                                 

Parameters

 

 

Key   

Features 

 
 

Frequency 

  Range 

Sine wave 

Normal mode

MHS-5200-06M

0Hz~6MHz

 

                        MHS-5200-12M

0Hz~12MHz

 

                        MHS-5200-20M

0Hz~20MHz

 

                        MHS-5200-25M

0Hz~25MHz

 

Square wave  0Hz~6MHz 

Triangle wave  0Hz~6MHz 

Sawtooth 

0Hz~6MHz 

Arbitrary 

Waveform 

0Hz~6MHz 

TTLDigital 

signal wave 

0Hz~6MHz 

Output modulation 

Frequency sweep 

Waveform types 

Sine, square, triangle, sawtooth lift, TTL digital signal wave, Arb 

Waveform Length 

2048 Point 

 


background image

 

 

  

4

 

Sampling rate 

200MSa/s 

Waveform 

amplitude 

resolution 

12 bits 

The minimum 

frequency 
resolution 

10mHz 

Frequency error 

±5×10

-6

 

Frequency stability 

±1×10

-6

 

Amplitude range 

(peak to peak) 

  15mVp-p~15Vp-p(12MHz or less) 
  15mVp-p~8Vp-p(12MHz above)                                                                                                         

Output Impedance 

50Ω±10% 

Amplitude 

resolution 

1mVp-p

-20dBAttenuation

 

10mVp-p

Does not decay

 

Amplitude stability 

±0.5%

Every five hours

 

Amplitude error 

± 1%+10mV

Frequency1KHz

15 Vp-p

 

Offset Range 

120%

+120%

The ratio of the bias voltage and signal 

amplitude

 

Bias Resolution 

1% 

Phase range 

0

359° 

Phase resolution 

1° 

Sine wave 

Harmonic arrived 

System 

40dBc(<1MHz) ,35dBc(1MHz~20MHz) 

Distortion 

<0.8%(20Hz~20KHz) 

Square wave 

Lifting along time 

≤20ns 

Overshoot 

≤10% 

Duty cycle 

adjustment range 

0%~99.9% 

  TTL 

Lifting along time 

≤20ns 

LOW 

<0.3V 

High 

1V~10V 

Arbitrary 

Waveform 

Quantity 

16 groups 

Memory depth / 

group 

1KB / 16 group 

Scan 

Scan Mode 

Linear sweep, log sweep 

Scan time 

1S

999S 

Scan range 

It is determined by the sweep parameter settings 

External 

measurements 

Frequency range 

  GATE-TIME=10S              0.1HZ - 60MHZ     
  GATE-TIME=1S                    1HZ - 60MHZ       
  GATE-TIME=0.1S              10HZ - 60MHZ     
  GATE-TIME=0.01S          100HZ - 60MHZ   

 


background image

 

 

  

5

 

Input voltage range 

0.5Vp-p~20Vp-p 

Counting range 

0~4294967295 

Counting 

Manually 

Positive and 

negative pulse 

width 

measurement 

10ns resolution, the maximum measurable 10s 

Periodic 

measurements 

20ns resolution, the maximum measurable 20s 

Duty Cycle 

Measurement 

0.1% resolution, measuring range from 0.1% to 99.9% 

Source Selection 

1.Ext.IN input (AC signal), 2.TTL_IN input (digital signal) 

Memory 

Memory 

10 

Location 

M0-M9 

Interface 

Interface 

Using USB to serial interfaces 

Communication 

rate 

57600bps 

Protocol 

Using the command line, the agreement public 

  Power supply  

DC 

  DC 5V 

  Size 

Length × width × 

height 

180×190×71mm 

  Weight 

Single 

546g 

 

 

 

 

 

 

 

 


background image

 

 

  

6

 

Instrument Description 

1

Panel 

MHS-5200A  Appearance  Figure  2-1  shows  the  description  of  the  parts  as  shown  in 
Table 2-1.Figure 2-1 MHS5200A panel 

 

 

 
 

Table 2-1 MHS5200A Panel 

Grade                Explanation 

Grade                  Explanation 

  1 

LCD1602 

CH2 output interface 

  2 

Status Indicator 

DV5V power input   

  3 

Operation buttons 

USB 

communicationinterface 

 


background image

 

 

  

7

 

  4 

Knob 

10 

TTL input / output 

interfaceinterface 

Ext.In input interface 

CH1 output interface 

11 

Switch 

2

Ribbon Description

 

LCD instrument display is divided into two functional areas, as shown in Figure 

2-2, description of the parts shown in Table 2-2. 

 

Figure 2-2 MHS5200A schematic display

 

Table 2-2 MHS5200A Ribbon Description 

 

                   

 

 

3

Key Functions

 

 

Cursor left adjustable parameters of the step value 

 

Move the cursor right step to reduce the adjusted parameter value 

 

Page Up key function selection 

 

Function selection Page down 

 

OK button 

 

Channel switch (CH1 \ CH2) 

 

Switching position, when the "*" when the "*" second line adjustment 

options to adjust the frequency of the first line, 

 

Click this button to quickly enter a combination of waveform adjustment 

page 

 

Click this button to quickly enter a combination of amplitude modulation 

page 

  Grade 

                Ribbon Description 

      1 

Frequency Display 

      2 

Operation Feature Tip 

 


background image

 

 

  

8

 

 

Click this button to turn on or off output combination 

       

 

Instructions 

Power 

1

Access 5V supply. You can use the box to configure oriented instrument powered 

DC5V power adapter. 

2

Enter the main interface. 

Instructions 

        This  section  will  detail  how  to  operate  the  instrument.  It  should  be  noted  that, 

similar  to  the  instrument  channel  CH1  CH2  channel  with  which  the  operating 

instructions section 1-6 also apply to CH2 channel. 

1

Set the CH1 waveform 

Drawing 2-3 

 

In  the  main  interface  shown  in  Figure  2-3,  when  the  "*"  in  the  first  line

Click

Bond Adjust the output waveform type, the output waveform types are sine, 

square,  triangle,  rising  sawtooth,  descending  sawtooth  wave  and  a  16-Group  on 

Arbitrary,Press

Key it is possible to return ahead of the original set of waveform

If you want to quickly adjust the output waveform can click

Then a 

"*" to switch to the second row, rotating "ADJUST" knob, you can quickly switch the 

output waveform types.

 

 

2

Set the CH1 frequency

 

In  the  main  interface,  shown  in  Figure  2-4  when  the  "*"  in  the  first  line,By 

 


background image

 

 

  

9

 

adjusting

or

Move the cursor to adjust the frequency step size

Then to adjust 

the frequency of the output waveform by rotating the "ADJUST" knob. 

         

                                     

 

2-4

 

3

Setting the amplitude of CH1 

In  the  main  interface

Press

 

Button  after

The  magnitude  of  the 

interface will appear in a cursor set

Click

or

Button, It is possible to move the 

cursor  position,  rotate  "ADJUST"  knob  to  adjust  the  amplitude  of  the  output 

waveform, as shown below: 

                                                           

  Drawing 2-5

 

Wherein,  05.00V  refers  peak  to  peak.  In  this  range  setting  function  mode,  the 

maximum amplitude of 20V, minimum 0.20V, the minimum step value 0.01 (10mV); 

as shown in a state 2-6

Press

-20dB Attenuation state of the incoming signal, the 

output signal of a maximum of 2.000V, the minimum value of 0.005V, the minimum 

step is 0.001V (1mV). 

                                                   

 

  2-6

 

4

Setting bias of CH1

 

 


background image

 

 

  

10

 

In the main interface

Press

Adjusted to  offset  adjustment options 

shown  in  Figure  2-7

Then  click

 

The  "*"  are  switched  to  the  second 

row

Click

or

To move the cursor

Then"ADJUST" knob to adjust the offset 

parameter. 

                                                     

Drawing 2-7

 

5

Duty cycle setting CH1

 

In  the  main  interface

Press

or

Adjusted  to  duty  cycle  adjustment  options 

shown in Figure 2-8

Then click 

 

The "*" are switched to the second 

row,  click

or

To  move  the  cursor

Then"ADJUST"  knob  to  adjust  the  offset 

parameter. 

                                                     

Drawing2-8

 

5

Setting the phase difference between the two channels 

In the main interface

Press

or

Adjusting the phase adjustment options shown 

in  Figure  2-9,  Then  click

 

The  "*"  are  switched  to  the  second  row

Click

or

To  move  the  cursor

Then"ADJUST"  knob  to  adjust  the  bias 

parameter,  you  need  special  note  is  the  phase  difference  only  in  the  same  frequency 

CH1 and CH2 frequency when it makes sense. 

 

 

 


background image

 

 

  

11

 

Drawing 2-9

 

6

Setting the display unit of frequency 

In the main interface

Press

or

Adjusted to the frequency display unit 

adjustment  options  shown  in  Figure  2-9,  Then  click 

 

The  "*"  are 

switched to the second row

Then click

Switching frequency units Hz

kHz

MHz

 

                                                 

  2-10 

7

Tracking 

Tracking  function  is  used  to  synchronize  the  frequency  of  CH2  to  CH1,  and 

users  can  set  the  amplitude  of  the  tracking  and  duty  track,  In  the  main  interface

Press

or

Adjusted  to  tracking  options  shown  in  Figure  2-11

Then 

click

 

The  "*"  are  switched  to  the  second  row,  and  then 

click

Switched ON or OFF state. When the tracking function is turned frequency 

automatic  tracking  frequency  channel  CH2  CH1  channel.  Also,  before  turning  if 

tracing,  CH1  and  CH2  channel  amplitude  is  the  same  tracking  feature  is  turned  on 

CH1 and CH2 frequency automatic tracking; if the duty is the same as CH1 and CH2 

are turned on after tracing CH1 and CH2 account empty than automatic tracking. 

 


background image

 

 

  

12

 

                                                           

Drawing 2-11 

8

External signal input port selection 

  Select  the  input  signal  Ext.IN  for  input  AC  signal,  Select  TTL.IN  for  selecting  the 

input digital signal wave. In the main interface,Press

or

Adjust to the input 

port  selection  page,  Then  click 

 

The  "*"  are  switched  to  the  second 

row,Then click

Key switch input port selection Ext.IN or TTL.IN. 

                                                           

  2-12 

9

Measurement function 

In  selecting  the  input  source  later,  the  input  signal  can  be  measured  a  variety  of 

parameters. 

1)  In  the  main  interface,  Press

or

,Adjusted  to  the  measurement  function 

selection page shown in Figure 2-13

Then click

 

The "*" are switched to 

the  second  row

Then  click

Bond  Switch  the  output  port  selection  measurement 

object.  FREQ.

Frequency

)、

COUNTR(Counting  function)

POS-PW(+  Width)

NEG-PW(Negative Pulse Width)

PERIOD(Cycle)

DUTY

Duty cycle

 

 


background image

 

 

  

13

 

Drawing2-13 

2

After determining the measurement object

Click

Enter gate time selection 

page as shown below: 

3

Click

Bond

Select a different gate time 10S, 1S, 0.1S, 0.01S, different gate 

time on the frequency measurement accuracy and measurement speed. 

                                            Drawing 2-14

 

3

Gate time is determined

Click

Enter the measurement results display. 

The  page  can  display  the  input  measurement  results,  such  as  frequency,  duty  cycle, 

pulse width, and so the cycle parameters.

 

10

sweep function 

   

1

    Adjusted to  start  frequency sweep function settings page, and  then adjust 

the start frequency 5kHz. As shown below: 

Drawing2-15

 

 

 

2

  Then click 

    Into the cut-off frequency sweep function settings page, and 

then adjust the cutoff frequency of 10kHz. As shown below: 

 


background image

 

 

  

14

 

Drawing2-16

 

 

3

    Then  click 

  Enter  sweep  time  setting  page

Then  click   

The  "*"  are  switched  to  the  second  row

Rotation  "ADJUST"  knob  to 

adjust the sweep time, frequency arbitrarily set the time range between 1-600S, shown 

in the lower set sweep time 10S: 

4

 

Then  click 

    Enter  sweep  mode  selection  screen  shown  in  Figure 

2-22,  Click

Bond  Select  the  frequency  scan  mode

There  are  two  ways  to  scan 

frequency, LINE (linear scanning) and LOG (logarithmic sweep). 

5

 

After determining the scan mode

  Click

  Enter sweep control page

Then click

on or off sweep function. 

 

11

Save / Load function

 

In the main interface, press

or 

Enter the parameter to save the page, and 

then  click

Press  the  key  combination  of  "*"  consumption  is  adjusted  to 

the second row in Figure 2-11, then rotate "ADJUST" knob to adjust the save location, 

this  machine  a  total  of  10  sets  of  parameters  stored  addresses  M0-M9.  Machine  is 

turned on by default to read M0 address parameters. 

 


background image

 

 

  

15

 

                                             

   

  2-16

 

In  the  main  interface,  press

or

Enter  the  parameter  to  call  up  the  page, 

then  click

Press  the  key  combination  of  "*"  consumption  is  adjusted  to 

the second row in Figure 2-12, then rotate "ADJUST" knob to adjust the save location, 

this  machine  a  total  of  10  sets  of  parameters  stored  addresses  M0-M9.  Machine  is 

turned on by default to read M0 address parameters. 

                                                   

  2-17

 

12

Calibration function

 

        Calibration  function  is  we  do  a  job  at  the  factory,  you  can  consult  the  factory 

calibration is required. 

 

Chapter Four PC Instructions

 

1

install software 

Step 1: Install the runtime software visa540_runtime.exe 
Step 2: Install CH341SER the SETUP.exe serial to USB drivers 
Step 3: Install signal generator .exe program 

2

online 

Step 1: Right-click Computer - Properties - Device Manager - observation 

assigned 

to the computer serial port

 

 


background image

 

 

  

16

 

 

 

Step 2: Select the appropriate serial line after the point 
 
 
 
 

 

 

 


background image

 

 

  

17

 

Step 3: Online Success 

 

1

Output standard waveforms 

1

The PC is connected, switch to expand the page, select the standard waveforms, 

such as pulse Sinclair 

 


background image

 

 

  

18

 

 

 

 

Care and maintenance 

 

1.  Make  sure  the  input  power  adapter  correctly,  the  machine  uses  DC5V  power 

adapter; 

2,  the  instrument  display  on  the  LCD  module  is  fragile,  perishable  items,  please  do 

not  slam  and  near  chemicals  to  prevent  corrosion.  When  you  feel  the  liquid  surface 

dust and dirt, wipe with a soft cloth carefully. 

3, the working temperature of -10 ~ 50 

, Storage temperature -20 ~ 70 

, and the 

instrument in a dry environment. 

4.  Do  not  attempt  to  disassemble  the  equipment,  destroy  the  package  will  void  the 

warranty.  The  instrument  is  there  are  no  user-serviceable  parts,  repairs  may  only 

repair outlets or by specifying the return factory. 

5,  avoid  lighted  candles,  a  water  cup,  corrosive  chemicals  and  other  unsafe  items 

placed on the surface of the instrument, so as not to cause damage to the instrument. 

6,  the  display  screen  are  easy  to  pollution,  fragile  device,  do  not  touch  the  hand  as 

well as external and collision, avoid children play this instrument. 

 


background image

 

 

  

19

 

7.  Do  not  move  the  instrument  to  avoid  severe  irreparable  damage  to  the  internal 

circuit when the instrument is working properly. 

Exclude  the  above  problem  re-power  the  instrument  still  does  not  work,  please 

contact your supplier!