PDF User Manual

  1. Home
  2. Manuals
  3. Midea KJR-29B/BKE-E Operation Manual

Midea KJR-29B/BKE-E Operation Manual

KJR-29B

Made by: Midea
Type: Operation Manual
Category: Controller
Pages: 16
Size: 1.03 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 
 
 
 

 

Operation Manual 

 

Touch- style key wired controller 

 

 

 

 

 

 

 

KJR-29B/BKE-E 

 
 

 


background image

 

 

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

 
 
CONTENTS 

 

 

1. Safety Precautions ...............................................................................  5 

2. Model and Specification ......................................................................  6 

3. Buttons And Their Functions ...............................................................  7 

4. Installation ......................................................................................... 10 

5. Wiring................................................................................................. 11 

 

  

 

 

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

1. Precautions

 

 

The  following  contents  are  stated  on  the  product  and  the  operation  manual,  including  usage, 
precautions  against  personal  harm  and  property  loss,  and  the  methods  of  using  the  product 
correctly and safely. After fully understanding the following contents (identifiers and icons), read 
the text body and observe the following rules. 
 
 
 
 

 

Warning 

Means improper handling may lead to personal severe injury. 

 

Caution 

Means  improper  handling  may  lead  to  personal  injury  o  property 
loss. 

 
 
 

 
 

 

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

2. Model And Specification 

 

 

Model 

KJR-29B/BKE-E 

KJR-29B

 

Power Supply Voltage 

5.0V DC 

Ambient Temperature Range 

-5°C

+43°C 

Ambient Humidity Range 

RH40%~RH90% 

 

Performance features 

 
1. Operating mode: Cool, heat, dry, fan and auto. 

2. Set the mode through buttons. 

3. Indoor setting temperature range: 17°C ~30°C. 

4

LCD (Liquid Crystal Display). 

5. Touch-style key 

 

Function summarize 

KJR-29B/BKE-E

 is the touch-style key wired controller. 

New function 

Basic function 

Air filter cleaning reminding function 

ON and OFF the air-conditioner 

Indoor unit address setting function 

Auto-restart function 

Remote control receiver function 

Time ON and Time OFF setting 

Lock the wired controller 

Clock setting 

Quiet operation  

Setting the Operating mode, Temperature 

Follow me 

Fan speed and Swing functions 

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

3. Buttons And Their Functions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

(1)  Remote signal receiving function 

There is the signal receiver for wireless remote controller on the KJR-29B.You can use the 

wireless remote controller to control the air-conditioner through the wired remote controller when 

the system has been powered on. 

Notes: 

The wired controller will not receive the swing controlling instruction. For the indoor unit with swinging 

function, you can directly use the remote controller to control swinging through the display panel of the indoor unit, 

or use the swing button on the wired remote controller to control the indoor unit for swinging. 

(2)  ON/OFF button 

Press the ON/OFF button to control the indoor unit on and off status. When the unit is turned off, 

press the ON/OFF button, the unit will be turned on and the operating icon lights up. When the 

unit is turned on, press the ON/OFF button, the unit will be turned off and the operating icon lights 

off. 

(3)  Mode button 

Press the mode button to set the operating mode, after each button press the operation mode will 

circle as follow: 

 

When the controller has been set to cool-only, then there is no HEAT mode. 

(4)  Fan speed setting 

Under COOL, HEAT and FAN modes, press the fan speed button can adjust the fan speed 

setting. After each fan speed button press will circle as follow: 

 AUTO

LOW

MID

HIGH

AUTO 

Under AUTO and DRY modes, the fan speed is not adjustable and the default fan speed is auto. 

AUTO

COOL

DRY

HEAT

FAN

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

(5)Temperature setting

 

Under AUTO, COOL, DRY, HEAT modes, press the Temp adjust Up/Down buttons to set the 

temperature, the adjusting range is 17

~30

 (or 62

~88

). The setting temperature cannot be 

adjusted under FAN mode. 

(6)Timer on and Timer off setting

 

Press the timer/clock setting button, then enter into the timer on setting status, and the screen will 

display timer icon 

and

You can press Temperature setting buttons to adjust the time. When the time setting is less than 

10 hours, each press the Temp setting buttons will increase or decrease 0.5 hour. When the timer 

setting is more than 10 hours, each press Temp setting buttons will increase or decrease 1 hour, 

the maximum timer setting is 24 hours. After finish adjusting the time on setting, press the 

26

/OK button or wait for 5 seconds to confirm and exit the time on setting. 

Notes: I

f the wired remote controller has been set timer on/ off, press the ON/OFF button to turn on/ turn off the 

unit then the timer will be canceled simultaneously

(7) Clock setting 

Long press the timer/clock setting button for 3 seconds, and then enter into the clock setting 

status. The hour position of the clock will flash, and can press Temp setting buttons to adjust the 

hour value. 

After finish the hour setting, press left button or right button to switch to minute position setting, 

then the minute position will flash, press Temp setting buttons to adjust the minute value. After 

finish the clock setting, press the button or wait for 5seconds to confirm and exit the setting state. 

(8)Quiet/OK button

 

Under the cooling, heating and auto mode, when operate the quiet mode, it can reduce the 

running noise through setting the fan speed to low. This will help you bring a quieter environment. 

Under AUTO, DRY mode, the fan speed is auto and the Quiet /OK button doesn’t work. 

(9) Wired controller locking 

Press the temperature adjusting UP and DOWN buttons simultaneously, the wired controller 

enters into locking state, and the locking icon will be lighted up. Under the locking state, the wired 

controller will not respond to buttons by pressing and the control instruction from the wireless 

remote controller. Simultaneously press temperature adjusting buttons again will cancel the 

locking state. 

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

(10) Air filter cleaning reminding function 

The wired controller records the total running time of the indoor unit, when the accumulated 

running time reaches the pre-set value, air filter cleaning reminding icon will be lighted up, to 

remind that the air filter of the indoor unit needs to be cleaned. Long press left button for 3 

seconds, and clear the reminding icon and the wired controller will re-accumulate the total 

running time of the indoor unit. 

Notes:

 The default setting value of reminding function is 2500 hours, and it can change to be 1250 hours, 5000 

hours or 10000 hours. The setting methods please refer to the installation manual. 

(11)Swing function 

If the indoor unit supports swing function, press the right button to adjust the air outlet direction of 

the indoor unit. Long press this button for 3 seconds can turn on or turn off the auto-swing 

function. When the auto-swing function is turned on, the swing icon will be lighted up. 

(12)Follow me function 

When the system is running and the operating mode is AUTO. COOL or HEAT, press the left 

button will activate the Follow Me function. Press left button again will cancel follow me function. 

When the operating mode is changed, and then will cancel this function as well. When the Follow 

Me function is activated, the icon will be light up, and the wired controller will display room 

temperature read from the local sensor, and transmit the temperature value to the indoor unit 

every 3 minutes. 

(13) Setting addresses 

§

 

Press the Temp. UP and DOWN button simultaneously for more than 8 seconds, then the 

controller gets into address setting mode. 

§

 

In the address setting mode, there are 2 main functions: 

§

 

Querying address: Press MODE button, the corresponding indoor unit will display its 

address. 

§

 

Setting address: Use the UP and DOWN buttons to choose an address you want. Then 

press the FAN button to set the indoor unit's address. The corresponding indoor unit will 

display the new address and record it. After about 4 seconds, this displaying will fade out 

and indoor units turn to normal display mode. 

§

 

After setting addresses, users can press the Quiet/OK button can exit the address setting 

mode. 

§

 

After each setting address and enter the query / set mode again, it will display the last set of 

address, but if re-power, this address will be cleared. 

§

 

In the address setting mode, wired controller does not respond to any command from remote 

controller. 

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

4. Installation 

 

Preparation before Installation: 

Make sure the following pasts has been prepared. 

NO. 

Name 

QTY. 

Remarks 

Wired Controller 

Cross round heat wood 

Mounting Screw 

M4×20(For mounting on the wall) 

Cross round heat 

mounting Screw 

M4×25(For mounting on the electrical switch box) 

Installation Manual 

Owner's Manual 

Plastic expansion pipe 

For mounting on the Wall 

Plastic screw bar 

For fixing on the 86 electrician box 

Switching wires for 
signal receiving board 

For connecting the signal receiving board 
and 4-core shielding wire 

Switching wires for wired 
controller signal 

(If needed) For connecting the main control 
panel and 4-core shielding wire 

 

 

Prepare for the following at installation site. 

NO. 

Name 

Qty.(embedded 
into wall) 

Specification remarks 
(only for reference) 

Remarks 

4-core Shield Cable 

RVVP-0.5 mm

2

×4 

0.05 mm

2

×5 cable 

no more than 12M 

86 electrician box 

Wiring Tube(Insulating 
Sleeve and Tightening 
Screw) 

 

 

Dimensions:120*120*20mm 

 

 

Figure A

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

10 

5. Wiring  

 

Wiring principle sketch: 

 

 

Wiring figure: 

1) Connect two terminals of embedded 4-core shielding wire with the switching wires of wired 

remote controller and signal receiving board. Make sure the sequence of 4 terminals (A/B/C/D) 

should correspond to the wire sequence of signal switching wires (A/B/C/D).

 

 

 

2) If embedded 4-core shielding wire cannot go through the wired controller, it can use signal 

switching for connection and make sure the wires are reliable and firm. The tightening torque 

range of the screw is0.8~1.2N .m (8~12 kgf . cm). 

 

 

 

Back cover installation 

1) Use straight head screwdriver to insert into the buckling position in the bottom of a wired 

controller, and spin the screwdriver to take down the back cover. (Pay attention to spinning 

direction, if not you maybe damage the back cover.) 

C
D

A
B

C

D

A

B

C D

A B

+5V

GND

IR+

IR-

4-core shielding wire embedded in the wall

Attached connecting wires for the signal receiving panel

Signal receiving panel

Front cover

Control panel

Screw

Signal switching wire

4-core shielding wire

embedded in the wall

Attached connecting wires for

the signal receiving panel

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

11 

 

2) Use three GB950-86 M4X20 screws to directly install the back cover on the wall. 

 

3) Use two M4X25 GB823-88screws to install the back cover on the 86 electrician box, and use 

one GB950-86 M4X20 screw for fixing the wall. 

 

4) Adjust the length of two plastic screw bars in the accessory to be the standard length from the 

electrical box screw bar to the wall. Make sure when install the screw bar to the electrical box 

screw bar, make it as flat as the wall. 

 

Buckling position

Back cover

Front cover

Straight head screwdriver

Screw hole installed on

the wall,use three

GB950-86 M4X20

Screw hole fixed on

the wall,use one

GB950-86 M4X20

Screw hole installed
on 86 Electrician box,
use two

 

86 Electrician box

Signal switching wires

Back cover

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

12 

Notes: 

1.Use cross head screws to fix the wired controller bottom cover in the electric control box through the 

screw bar. Make sure the wired controller bottom cover is on the same level after installation, and then install the 

wired controller back to the bottom cover. 

2. Over fasten the screw will lead to deformation of the back cover.

 

 

Wiring 

1) Wiring, three outlet positions 

 

2) Shielded wiring 

 

 

 

 
 
 

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

13 

 

Front cover installation 

1) After adjusting the front cover and then buckle the front cover; avoid clamping the communication 

switching wire during installation. 

2) Correct install the back cover and firmly buckle the front cover and back cover, if not you maybe 

make the front cover drop off. 

 

 

Wired controller initial parameters setting: 

1.

 Change the related functions of the controller through adjusting the initial parameters, details refer to 

table 1 

2. The wired controller initial parameter includes two codes "XY", the first code "X" means function 

class, and the second code "Y" means the detailed configuration of this function. 

3. Setting method:  

1

Simultaneously press "Mode" and "Fan" button of the wired controller for 5 seconds to enter the 

parameter setting state; 

2) The value of this first code "X" is "0"; press the temperature setting button UP and DOWN to adjust 

the second code value; 

3) After setting the second code value, press 26/OK button to switch the first code to the next value; 

4) When the first code value is "6", press 26/OK button again to exit the parameters setting. 

4. The parameters setting function only under the situation which needs to adjust the default functions' 

setting states; otherwise there is no need to do the setting. 

                                            Table 1 

First 

code 

Functions 

Second code 

Cool-only/ Cool-Heat 

selection 

Cool-Heat 

(Default) 

Cool-only 

 

Indoor unit communication 

address setting 

Yes (Default) 

None 

Auto-restart 

Yes (Default) 

None 

Air filter cleaning reminding 

function 

Cancel the 

reminding 

function 

1250 hours 

2500 hours 

(Default) 

5000 

hours 

10000 

hours 

Remote receiving function 

Yes (Default) 

None 

Centigrade/ 

Fahrenheit display 

Centigrade 

Fahrenheit 

 

 


background image

OPERATION MANUAL                        

     KJR-29B/BKE-E 

14 

 

 

 

 

 

 

 

 


background image

 

15 

 


background image