Automatic switching or dimming when used in combination

 with 1-10V dimmable LED drivers or ballasts.

Built-in daylight sensor.

1-10V interface can match up with Merrytek stand-alone 

daylight sensor MS01 and achieve daylight harvesting.

Compact size makes it suitable to fix within most luminaires.

Detection area, time delay and daylight threshold can be 

precisely set via DIP switch.

Wide detection area, range up to 16m in diameter.

Support higher mounting height 15m Max.

Optional surface mounting and base mounting 

Introduction

The  MC601V  innovative  and  active  motion  detectors  with 

HF  system  5.8GHz.  Motion  can  be  detected  through 

plastic, glass and thin non-metal materials. 

The  sensors  allow  energy  saving  without  compromising 

comfort.  When  used  in  combination  with  1-10V  dimmable 

LED  drivers  or  ballasts,    they  can  achieve  3-step  dimming 

function,  which  is  perfect  for  use  in  some  areas  that 

requires a light change notice before totally switch off. 

Also, the 1-10V interface in the sensors can match up with 

M e r r y t e k  s t a n d - a l o n e  d a y l i g h t  s e n s o r  M S 0 1 ,  a n d 

implement  daylight  harvesting,  means  the  lighting  system 

has  automated  controls  that  either  turn  off  or  dim  artificial 

light in response to the available daylight in the space.

As it uses the third generation Merrytek technology, normal 

5.8GHz microwave module can easily reach high mounting 

high  up  to  15m  and  long  detection  area  10m  in  radius.

Light Sensor

Max.8M

Hold Time 

10s~30min

15m

Mounting Height

 15 m Max. 

Automatic

 

Dimming

10

%

50

%

5 Years 

Guarantee

5

5

Years 

Guarantee

SYNC

Cluster-control 

Version

MC601V
North America Version / Dimming Function

C

US

Dim

mi

ng 

 


background image

Wiring  scheme

Lamps in corridor are controlled by several sensors. Once any motion is detected by one of sensors, the motion 
signal will be transmitted to other sensors connected together. Then, all lamps switch on at the same time, instead 
of switching on the lamps in the area where motion is detected. 

Dimming Function

3-step dimming function

No motion detected,

all lamps switch off.

1

Any movement is detected 

from any direction, all lamps

synchronously switch on.  

2

No  motion  is  detected  in 
detection  area,  all  lamps 
synchronously dim to a low
light level after hold time.   

3

After stand-by period, the
lamps  switch  off  if  no 
movement  is  detected  in 
the detection zone.

4

3

6

6

12

3

sensor

slave

slave

slave

sensor

sensor

2

sensor

slave

slave

slave

sensor

sensor

1

sensor

slave

slave

slave

sensor

sensor

4

sensor

slave

slave

slave

sensor

sensor

 


background image

Wiring  scheme

ON -OFF Function

  

Motion sensor MC601V + LED driver or ballast (Any brand) 

MC601V is an innovative motion sensor, switch on the light on detection of movement, and switch off after a hold 
time when there is no motion detected. As built-in daylight sensor can read brightness value, the sensor does not 
switch on the light if with sufficient natural light. 

With sufficient light, the lamp 
doesn't switch on.

After hold time, the sensor 
switches off the lamp when 
no motion is detected.

1

2

3

With insufficient ambient light, 
the sensor switches on the lamp
when motion is detected.

Daylight Harvesting

When used in combination with Merrytek daylight sensor MS01, the system has automated controls that either 
turn off or dim artificial light in response to the available daylight in the space.

Ambient light below than 
preset illumination level, 
the lamp switches on 
when motion is detected.

Ambient light larger than 
preset illumination level 
(Set by 1-10V daylight 
sensor), the lamp keeps 
off.

The lamp lights on 100% illumination or dims to maintain the preset illumination 
level against the level of ambient light. 

L

N

Control gear

Max. 400W

L

N

Control gear

L

N

Control gear

 


background image

Wiring  scheme

If  with  sufficient  ambient 
light,  the  lamp  turns  off 
at once,even with motion
trigger.

If with insufficient ambient light, the lamp dims to stand-by dimming level (Set in the motion 
sensor) when no motion detected ofter hold time, and then switches off after stand-by period.

3

6

6

12

Detection Pattern

Ceiling  mounting pattern (Unit: m)
Suggested installation height: 2.5-10m

Wall mounting pattern (Unit: m)
Suggested installation height: 1-1.8m

10%

25%

50%

75%

100%

0

2

4

8

6

2

4

6

8

10

12

14

10

12

14

10

12

14

16

16

16

18

18

18

10%

50%

75%

100%

 


background image

Detection area 

Detection area can be reduced by selecting the combination on the 

DIP switches to fit precisely each application .

MC601V

Setting

Hold time 

Refers to the time period the lamp remains at 100% illumination after no 

motion detected.

Stand-by period

Refers to the time period the lamp remains at a low light level before it 

completely switches off in the long absence of people. 

When set to“     ”mode, the low light is maintained until motion is detected.

Stand-by dimming level 

The low light level you would like to have after the hold time in the long 

absence of people.

Daylight sensor

The sensor can be set to only allow the lamp to illuminate below a defined 

ambient brightness threshold. 

When set to Disable mode, the daylight sensor will switch on the lamp when 

motion is detected regardless of ambient light level. 

50lux, 30lux: twilight operation, 10lux, 5lux: darkness operation only.

Note that daylight sensor is active only when lamp totally switches off. 

By selecting the combination on the DIP switches, sensor data can be precisely set for each specific application.

ON

ON

ON

Operating voltage              120~277Vac, 50Hz/60Hz

Rated capacitive load        120V@400W;220-240V@800W;277V@1000W

HF system                           5.8GHz±75MHz, ISM wave band

Transmitting power             <0.5mW

Power consumption           

0.5W(standby), <1W(operation)

Detection zone                   Max.(D x H): 16m x 15m

Detection sensitivity          10% / 50% / 75% / 100%

Hold time                             5s / 30s / 90s / 3min / 20min / +

Daylight sensor                  2lux/5lux / 10lux / 25lux /50lux / 100lux / Disable

Stand-by period                  0s /5s / 5min / 10min / 30min / 1h / +

Stand-by dimming level     10% / 20% / 30%  / 50%

Mounting height                 15m Max.

Motion detection                0.5~3m/s

Detection angle                  

150°(wall installation), 

                                             360°(ceiling installation) 

Operating temperature      -35

~70

IP rating                               IP20

ON

8

8