Interflex Datensysteme GmbH   

1/13 

 

 

 
Thank you for choosing a product from Interflex. With this product, you have purchased a reliable device for 

access control. 

 

1.1  Scope of delivery 

 

  IF-80x Outdoor terminal (slave) 

  I/O controller board for controlling locking devices 

  Material for fastening 

  8-pin terminal strip 

  Blue wire for grounding the back panel 

  Mortise lock 

  Plastic strips for sealing the mortise lock 

  Adhesive tape for mounting the I/O controller board 

 

  Please check the completeness and condition of the 

shipment upon receipt. 

 

1.2  CE conformity 

  The device complies with the requirements of the respective EU guidelines (CE conformity). 

Modifications to the device are not permitted.

 

All information contained in this documentation is accurate at the time of printing. All specifications are 

subject to change without notice. 
The product brand names and trademarks specified in this documentation are protected by commercial and 

patent laws. 

 

1.3  Shielded cables 

To ensure malfunction-free operation, we recommend the use of shielded bus cables. 
Operation is also possible with unshielded cables. In case of transmission problems, you will have to 

examine the reasons in each individual case. Where necessary, a shielded cable should be used for the 

connection of the respective devices. 

 

1.4  Intended use 

The device is used for reading RFID credentials, e.g. in access control systems, and also for controlling 

locking devices. Any other use is not in accordance with the intended purpose and is therefore not permitted. 

 

1.5  Function 

Slave terminals of series IF-80x Outdoor are used for: 

  controlling the access of people who identify themselves via an RFID credential before entering a 

security zone. 

  controlling and monitoring locking devices that prevent uncontrolled (physical) access to security zones. 

  writing NetworkOnCard access rights. The data is used for identification at offline devices, e.g. electronic 

door fittings. 

95-10330 V2017-07-24 

IF-80x Outdoor Slave Terminal 

 


background image

Interflex Datensysteme GmbH   

2/13 

 

  The terminals can be operated on terminal controllers or master terminals with the 

following controller software versions (minimum requirements): 

  IF-105x = Version 5.12.4.C2 

  IF-107x = Version 5.12.3 

  IF-407x = Version 7.12.3. 

 

1.6  Function of the IF-80x outdoor terminal 

Terminals of the IF-80x Outdoor series are part of an access control system. They are preferably installed 

directly next to locking devices. They are generally connected to a master terminal, access manager or 

terminal controller via an RS485 data cable. These terminals are designed for controlling the access of 

persons, who identify themselves with RFID credentials, as well as for controlling and monitoring locking 

devices. 

 

1.7  Storage 

The device has to be stored in a dry place. 

 

2  Assembly and Installation 

Please carry out the following steps in sequence: 

  Install all cables. 
  Mount the IF-80x Outdoor terminal. 
  Make the electrical connections and switch on the power. 
  Adjust the reader. 
  Set the hardware address. 
  Put the terminal into operation and test its functions. 

 

 


background image

Interflex Datensysteme GmbH   

3/13 

 

3  Installation 

3.1  Mounting the IF-80x outdoor terminal 

 

Recommendation:

 Install the terminal at a height of approx. 125 cm (distance from floor to bottom edge 

of the terminal). 

 

1  Mounting holes 

5  Vertical mounting option with DIN appliance case 

2  Alternative mounting hole for wall-mounted cable 

inserted from the bottom 

6  Mounting holes for US standard 

3  Cable gland 

7  Hole for adjusting the reader 

4  Horizontal mounting option with DIN appliance case  8  Foam rubber   

 

 

3.2  Important points to note regarding the mounting 

Please observe the following when mounting the terminal:

 

 

Do not make any changes to the back panel.

 

Fastening elements in other places can collide with the circuit 

board. 

 

 

 


background image

Interflex Datensysteme GmbH   

4/13 

 

 

Check for any unevenness in the panel.

 

The back panel of the device must be level and flush with the 

wall. 
Mechanical stresses can damage the device. 

 

 

Use only the original screws and do not use any 

washers.

 

Screws placed too high can cause collisions with other 

components and damage the device. 

 

 

 

 

Ensure short cable routing.

 

Cable loops can damage the device due to mechanical 

stresses. 

 

 

 

 

Tighten the screw only slightly or leave it out.

 

Tightening the screw too tightly can result in mechanical 

stresses which can damage the device. 

 

 

 

 


background image

Interflex Datensysteme GmbH   

5/13 

 

3.3  Fastening the back panel of the housing using an appliance case 

  Using a level, fasten the back panel of the housing by installing the 3 screws included in delivery in the 

holes marked (1). If the cable is to be inserted from the bottom, use mounting hole (2) instead of the 

bottom mounting hole (1). 

  Depending on how the appliance case is installed, you can additionally secure the back panel of the 

housing by installing screws in the two horizontal (4) or vertical (5) holes. 

  For further steps, please refer to: Attaching the IF-800 Outdoor/IF-801 Terminal. 

 

6  This is how the drain wire is wrapped around the 

insulation. 

8  The blue wire and the PE wire from the I/O controller board 

are connected to terminal 8 on the terminal strip. 

7  The blue wire is connected to the strain relief. 

9  Terminal strip 

 

 

3.4  Fastening the back panel of the housing with cable feed from the bottom 

  Using a level, screw in the back panel of the housing by installing 2 screws in the holes marked (1). 
  In addition, secure the back panel of the housing by installing a screw in the bottom left hole (2). 
  For further steps, please refer to: Attaching the IF-800 Outdoor/IF-801 Terminal 

 

10  The drain wire must have an electrical connection to 

the back panel of the housing. 

12  The cable lug of the blue wire is connected to the 

strain relief. 

11  Lug for fastening the wall reader with the M2x6 mm 

screw 

13  Lug for mortise lock 

 


background image

Interflex Datensysteme GmbH   

6/13 

 

 

 

4  Electrical Connections 

  Avoid damaging the device by: 

  establishing electrical connections only when no voltage is applied. 

  changing the position of jumpers or DIP switches only when no voltage is applied. 

 

4.1  Installation overview 

 

 

Power supply to mounting rail power supply unit 

(41-10106) 

4  Ethernet data cable from switch to controller/master 

terminal Cable length maximum 100 m. Power is 

supplied to the master terminal shown here via PoE or 

from an external power supply unit. 

Power supply to I/O controller board 

5  Data cable from I/O controller board to IF-80x Outdoor 

terminal 

Patch cable from computer to switch or hub 

6  RS-485 data cable from controller/master terminal to I/O 

controller board 

Please refer to the table "

Function of Cables and Cable Types

" for detailed information on the cable 

lengths, cable types and their diameters. 

 

4.1.1 Cable functions and cable types 

 

Cable Function

Max. Length 

Recommended Cable 

Type 

230 VAC power supply to 20 VAC, 1.5 A power transformer 

(order no. 41-10106) 

 

NYM 3 x 1.5 mm² 

Extra low voltage cable 

 

J-Y(ST) Y 4x2x 0.6 mm 

Ethernet/patch cable from server to switch/hub 

max. 100 m 

Category 5 

Ethernet/patch cable from switch/hub to controller/master 

terminal 

max. 100 m 

Category 5 

Shielded cable from IF-80x Outdoor terminal to 

controller/master terminal 

max. 100 m 

J-Y(ST) Y 4x2x 0.6 mm 

RS-485 bus cable 

max. 1200 m 

J-Y(ST) Y 4x2x 0.6 mm 

 

 

 


background image

Interflex Datensysteme GmbH   

7/13 

 

4.2  Wiring: Step-by-step procedure 

 

 

 

 

  Strip approx. 8 cm of the data cable. 
  Wrap the drain wire (6) around the end of the insulation of the data cable. 
  Feed the connection cable through the strain relief. 
  Install the strain relief in such a way that the end of the insulation with the drain wire is electrically 

connected to the back panel of the housing (10). 

  Clamp the blue wire under a nut of the strain relief (12). 
  Now, connect all of the cables coming from the I/O controller board to the terminal strip of the terminal. 
  Then, connect the blue wire from the back panel of the housing to the PE terminal. 
  Plug the terminal strip into the terminal. 
  Hook in the terminal at the top and press it down until it rests against the wall. 
  Screw down the terminal on the bottom left side (11) using the M2 x 6 mm countersunk screw included in 

delivery. 

  Insert the mortise lock on the bottom right side and lock the terminal (13). 
  Use the enclosed plastic strips to seal the mortise lock. 

 

 

 


background image

Interflex Datensysteme GmbH   

8/13 

 

4.3  Wiring overview 

 

1  IF-80x Outdoor terminal 

5  Circuit example: Control of an actuator (door opener). 

The actuator may only be operated with max. 30 V and 

2 A. 

2  I/O controller board 

6  Circuit example: Connection of both inputs. 

3  Circuit example: Power supply 

7  Address switch on the I/O controller board 

4  Circuit example: RS485 connection. The spur line may 

not be longer than max. 100 m. 

   

Bridges:

 

 

Br. 1:

 When one I/O controller board is used, bridge 1 is always plugged in. 

  If a second I/O controller board is used, remove bridge 1 on the second I/O controller board.   

 

Br. 2

: Bridge 2 is used to set the switching contacts of the NO/NC relay. 

 

Br. 3

: Instead of bridge 3, an anti-tamper switch can be connected. 

 

 

 


background image

Interflex Datensysteme GmbH   

9/13 

 

4.4  Connecting the I/O controller board 

 

Cable to IF-80x Outdoor terminal 

RS485 data cable 

Address switch 

Control line with 2 floating inputs and 1 relay output. 

Max. switching power: 30 V, 2 A 

Here, the power supply is connected with one line 

pair each. 

Relay output. Here, the cable is connected with one line 

pair each.   

Cable to power supply. Connection voltage: 18 to 

max. 24 V AC/DC 

Functional grounding and shield are connected to a 

terminal together. 

  Since the cable run to the IF-80x Outdoor terminal is usually very long, we 

recommend connecting the power supply and the relay contact with one cable pair each. 

 

4.5  Connecting a further I/O controller board 

 

If more than two inputs or more than one relay are required, you can connect a second I/O controller board 

(order no. 75-700-0141). 

  Remove jumper Br.1 on the second I/O controller board. 

Please keep in mind that the total length of the COM cable is limited to a maximum of 100 m. 

  Reduce the length of the COM cable, if necessary, to ensure that the total length of 100 m is not 

exceeded. 

Example:

 

The IF-80x Outdoor terminal is connected to I/O controller board 1 by a 30-meter-long cable. The cable for 

the connection of I/O controller board 2 may not be longer than 70 m. 

 

 


background image

Interflex Datensysteme GmbH   

10/13 

 

5  Synchronizing the Reader and Setting the LED Color 

Structural conditions may make it necessary to fine-tune or readjust the reader. To do so, the adjustment set 

with the order number 75-99-0004 is required. 

  In order to achieve the best result, perform fine tuning at the location of use while the back panel is 

attached. 

 

 

Anti-tamper switch 

Screw for adjusting the reader 

Terminal clamps 

2-pin DIP switch for setting the LEDs 

 

  Switch on the power supply. 
  Turn the adjusting screw (3) until the field indicator reaches maximum. 

Setting the LEDs 

Use the DIP switch (4) to set the LEDs according to the color of the display. The switch setting is usually 

preset (factory default). 

  Check the setting of the DIP switches according to the table specifications. 

 

Design 

Switch 1/design color white 

Switch 2/design color blue 

Glass, white 

OFF 

ON 

Glass, black 

ON 

ON 

 

  Further settings are reserved for other designs. 

 

6  Device Settings 

6.1  Setting the hardware address 

  Use the address switch to set the hardware address of the device. 

 

Switch 

Address 1 

OFF 

OFF 

OFF 

OFF (not required if connected to a master terminal) 

Address 2 

OFF 

OFF 

OFF 

ON 

Address 3 

OFF 

OFF 

ON 

OFF 

Address 4 

OFF 

OFF 

ON 

ON 

Address 5 

OFF 

ON 

OFF 

OFF 

Address 6 

OFF 

ON 

OFF 

ON 

Address 7 

OFF 

ON 

ON 

OFF 

Address 8 

OFF 

ON 

ON 

ON 

 

 


background image

Interflex Datensysteme GmbH   

11/13 

 

6.2  Setting the address without an I/O controller board 

If an I/O controller board without an address switch is used, you can set the address of the IF-80x Outdoor 

terminal via the RS-485 data cable. 
Once the terminal is connected to the controller, it responds with host address 8. 
Set the address of the terminal with a Telnet connection via the controller as follows: 

  Set up the connection to the controller with Telnet. 
  Use the command 

cfg

 to retrieve the terminal number. 

Example:

 

cfg

 -> address 8 has been set. 

 

  Enter this command: 

etp <address> -cx

 

 

The controller responds with TC-->ET(8)= 
Then, the command 34xxyy is sent directly to the terminal. 

Example: Address 1:

 

xx = New address A (uppercase) corresponds to 41(Hex) 
xx = New address a (lowercase) corresponds to 61(Hex) 
The command for setting address 1 is: 344161   

Correspondingly for address 2: 344262 (see table). 
Via a warm boot (command 55), the terminal then recognizes its new address: 

 

After approximately 10 seconds, the terminal is ready for operation and can be checked via the cfg 

command: 

 

  Make sure that an address is not used twice. The address must be within the address range of the 

controller (IF-4070). 

 


background image

Interflex Datensysteme GmbH   

12/13 

 

This table applies to a controller with 8 possible terminals on bus 1: 

 

Old Address 

Old HA 

Controller 

Command 

Command 

New Address 

New HA 

Bus 

etp 8 -cx 

344161 

etp 8 -cx 

344262 

etp 8 -cx 

344363 

etp 8 -cx 

344565 

... 

etp 8 -cx 

... 

.. 

... 

... 

etp 1 -cx 

344868 

etp 9 -cx 

344262 

 

 

6.3  Bridges on the I/O controller board 

Check the setting of the bridges and adjust them, if necessary: 

 

Br. 1:

 When one I/O controller board is used, bridge 1 is always plugged in. 

  If a second I/O controller board is used, remove bridge 1 on the second I/O controller board.   

 

Br. 2

: Bridge 2 is used to set the switching contacts of the NO/NC relay. 

 

Br. 3

: Instead of bridge 3, an anti-tamper switch can be connected. 

See also 

Wiring Overview ........................................................................................................................ 8 

 

 

7  Initial Operation 

  Once you have connected the IF-80x Outdoor terminal and set the address, lock it using the mortise 

lock. 

  Additionally fasten the device with the included M2 x 6 mm countersunk head screw. 
  Switch on the power supply. 
  Configure the terminal in your host software, e.g. the IF-6040 system. 
  Make sure that your software recognizes and controls (online operation) the terminal. 
  Perform a booking at the terminal with a suitable credential. 
  Make sure that the booking reaches your host system where it is further processed. 

For further diagnosis purposes, special programs and tools are available to system engineers and 

consultants. 

 

 


background image

Interflex Datensysteme GmbH   

13/13 

 

8  Technical Specifications 

IF-80x Outdoor 

 

Power Supply 

- 12 to 27 V AC 
- 11 to 38 V DC 

Power consumption 

Max. 4 VA 

Protection 

via PTC resistor 

Interfaces 

RS-485, 9600/19200 baud (automatic recognition) 

Reader for 

RFID credentials (Mifare or LEGIC as per order) 

Inputs 

2 for floating status contacts (4 with 2 I/O controller boards) 

Output relays 

1, max. 30 V, 2 A (2 with 2 I/O controller boards) 

User information 

Buzzer; green/red LEDs and, depending on the display color, blue or white 

Data entry 

- IF-800 Outdoor: no input facility 
- IF-801 Outdoor: Keyboard with numeric keypad 

Protection against sabotage 

Anti-tamper switch. Switches when front panel is removed. 

 

General Data 

 

Ambient temperature 

-25°C to +55°C 

Humidity 

Max. 95%, non-condensing 

Protection category 

III 

Degree of protection 

IP54, provided that the cables are installed according to instructions. The lower 

cable inlet must be masked using the included adhesive strip. 

Dimensions (L x W x D in mm): 

130.5 x 87 x 24 

Weight 

0.5 kg 

 

 

9  EU Declaration of Conformity 

 

Interflex hereby declares that the products comply with the directives 2014/53/EU and 

2011/65/EU. 
The complete EU Declaration of Conformity is available at the following Internet 

address: 

www.interflex.de/en/header/downloads/ce_declaration_of_conformity.html

 

 

10  Disposal 

 

 

Once its service life comes to an end, the device must be disposed of properly as 

electronic waste. The owner can dispose of the device himself or return it to the 

supplier. 

   