background image

 
 

Wireless Keypad 

GKP-S8M 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

User manual 

 


background image

Contents 

 
Congratulations  on  your  purchase  of  this  Honeywell 
wireless keypad. 
 
To  make  the  best  out  of  your  equipment  we  advise 
you to read this manual carefully. 
 
This keypad is designed to operate on an authorised 
radio frequency and will in no way endanger the user. 
 
 

Contents ................................................................................. 1

 

Introduction ............................................................................ 3

 

Arming using your code or tag ............................................. 4

 

Arming with a fault (*) ............................................................ 5

 

Disarming using your code or tag ........................................ 5

 

Resetting the system after an alarm (*) ................................ 6

 

Incorrect code protection ...................................................... 6

 

Personal attack ...................................................................... 6

 

Duress code ........................................................................... 7

 

Switch on/off receivers .......................................................... 7

 

Remote Maintenance (optional) ............................................ 7

 

User Programming functions ................................................ 8

 

Indicator lights (*) ................................................................ 12

 

Keypad tones ....................................................................... 13

 

Maintenance and recommendations .................................. 14

 



background image

Introduction 

This manual describes how to use your wireless keypad. 

The keypad is used to arm and disarm your security 
system using a valid access code or a key TAG. 

The keypad is equipped with a proximity tag reader, 

located next to the 

symbol; the keypad also features an 

integrated siren as a deterrent and 4 LEDs to inform you on 
system status. 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KEYPAD 

 

 

(*) If keypad installed with CMI, HMI, Sucre Box panels. Refer to Annex A if keypad 
installed with PMI panels. 

 

 

 

 

TAG 

 

Siren output 

System armed 
LED 

(LED 1)

 

Intruder alarm (*)

 

(LED 2) 
 

Total set 
arming key 

Tag reader area

 

S.O.S keys

 

Partial set 
arming key 

Tamper alarm (*) 
(LED 4) 

System fault (*)

 

(LED 3)

 


background image

 

 

 

Arming using your code or tag 

Press an arming key on the keypad and enter the code or present 
a programmed TAG.

 

 

 

Arms the total set 

 

Arms the partial set 

 

Arms the annex set 
(the keypad must be associated with Total 
+Annex) 

When the keypad is dedicated to the annex set only, the 

     

key will arm the annex set and the 

 key will be disabled. 

Arming can be performed with or without user identification 
depending on the panel setup.  

The arming tone is emitted by the keypad followed by the exit 
delay beeps. If a perimeter fault is signalled on arming, disarm 
the system before checking all the doors and windows equipped 
with contacts.  

The zone set arming is completed automatically at the end of the 
delay (depending on your system configuration).  

Notes

:  

Always make sure that your Total arming request is followed 
by the arming tone. 

Holding the TAG less than 1 minute in front of the keypad will 
not reverse the status. 

 

If a detector is parameter in final door, Total set arming is 
completed after you close the final exit door. After the door is 
closed, the exit delay beeps stop and the ‘arming complete’ tone 
is emitted by the panel and keypad siren. For Partial, the zone set 
arming is completed automatically at the end of the delay. 

 

 


background image

Arming with a fault 

(*)

 

If the system diagnoses a fault on arming, you cannot set the 
alarm. Faults include system faults, tampering and triggering of 
detectors. 

A tone indicating a fault is emitted by the keypad after the arming 
request instead of the arming tone. 

Check that all doors and windows fitted with contacts are closed. 

You can override prevention of arming by requesting arming a 
second time within two minutes from the first request. This will 
bypass all faults. 

The arming process restarts, the arming tone is emitted by the 
keypad followed by the exit delay beeps. Arming is completed at 
the end of the delay. 

(*) If keypad installed with CMI, HMI, Sucre Box panels. Refer to Annex A if keypad installed 
with PMI panels. 

Disarming using your code or tag 

To enable you to get to the keypad without triggering an alarm, 
your installer may have programmed an entry delay. 

To disarm your system: 

Enter a valid code or present a programmed TAG. 

The disarming tone is emitted by the panel and keypad siren. 

Disarming the system will also stop the sirens if an alarm is 
triggered. 

Important: Stopping the siren does not interrupt the 
transmission of the alarm to the alarm company. 

Notes:  

Always make sure that your disarming request is followed by 
the disarming tone. 

Always disarm the system when re-entering the premises. 

Holding the TAG in front of the keypad will not reverse the 
status. 


background image

 

 

 

Depending on your keypad’s configuration, this will disarm the 
total set or the entire system. In the latter case, the annex set 
might need to be re-armed. 

Resetting the system after an alarm 

(*)

 

If any of the LEDs 2, 3 or 4 are flashing slowly, an alarm has 
occurred (see page 12 for detailed LED functionalities). When 
there is an alarm in memory, the system must be reset before it 
can be armed. 

To reset the system:  

1.  Disarm it using a valid code or present a tag. 

2.  If there is more than one alarm in the memory, repeat this 

operation for each alarm until LEDs 2, 3 or 4 stops flashing 
slowly. 

If LED 4 is flashing quickly on your keypad, a confirmed alarm 
has occurred and a reset must be performed by your alarm 
company, you cannot operate the system. Call the operator. 

(*) If keypad installed with CMI, HMI, Sucre Box panels.

 

Incorrect code protection 

Important: If you enter five successive incorrect codes or 
present 5 invalid tags consecutively, the keypad will be 
blocked for 5 minutes. The intrusion siren will be triggered 
if the system is armed. 

Personal attack 

Note:

 This function is optional, and can be set at installation. 

You can send an alarm at any time, even when your system is 
not armed: 

Press the 

 

and

 

keys simultaneously. 

The siren is triggered (depending on the configuration). 

The central monitoring station is alerted (if the service is 
available). 


background image

Duress code 

Use a duress code if you are forced to disarm your security 
system under duress. Your duress code is obtained by adding 1 
to the last digit of your code (e.g. 1234 => 1235, 6789 => 6780). 

The system will disarm as normal but a silent alert signal is 
transmitted to your alarm company (depending on the 
configuration). 

Switch on/off receivers 

Note:

 This function is optional, and can be set at installation. 

It is possible to switch on/off receivers (such as smart plugs) from 
the keypad. 

To switch a receiver on/off: 

1.  Press the 

 key

 

to switch the selected receiver on or the

key to switch the selected receiver off. 

2.  Select the desired receiver by pressing a key corresponding to 

the receiver number 0 to 9 (0 corresponds to receiver number 
10). 

A high beep is played if the receiver is driven successfully; 
otherwise a low beep is played. 

 

Remote Maintenance (optional) 

Note:

 This function is optional and depends on the panel 

configuration. 

Press the 

 +

 keys simultaneously to activate the remote 

maintenance function as configured by your installer. Ask your 
installer for more information on this function.  

 

 


background image

 

 

 

User Programming functions 

Important: The system will automatically exit the 
programming mode after 20 seconds if no keys are 
pressed during this time. When this happens you must 
repeat all of the steps necessary for the function you are 
using. 

The keypad features 2 programming modes: 

 

- User Programming mode to adjust beep level, 

enable/disable the chime. 

 

- Master User Programming mode to manage user profiles 

(the keypad can have up to 10 user profiles configured). This 
mode can only be accessed with the master code (master user 
#1). 

 

USER FUNCTIONS 

To adjust the volume of the beep:  

1.  Press and hold the 

and 

 keys simultaneously more 

than 2 seconds to enter user programming mode. 

A double beep is played and all LED light on. 

2.  Keep pressing the 

 key to select the device that you wish 

to adjust (each device will emit a beep when it is selected). 

Example

: If you want to adjust the beep level for device 2: 

press the 

 

key twice. Device 2 will emit a beep to confirm 

its selection. 

All LEDs start flashing. 

3.  Press a key from 

to

to select the required beep volume 

(1 = min, 7 = max). 
The device selected will emit a beep at the new level to 
confirm the beep volume. 

4.  Press the 

 key to exit user programming mode and save 

you changes. 


background image

5.  After a few seconds, a double beep is played and all LED stop 

flashing. 

To enable/disable chime: 

1.  Press and hold the 

and

 

keys simultaneously more than 

2 seconds to enter user programming mode.  

A double beep is played and all status LEDs light on. 

2.  Press the 

 key. 

A double beep is played and all status LEDs start flashing. 

3.  Press the

 key to enable the chime or the 

 key to 

disable the chime. 

A long beep is played. 

4.  Press the 

 

key to exit user programming code and save 

you changes. 

5.  After a few seconds, a double beep is played and all status 

LED stop flashing. 

 

MASTER USER FUNCTIONS 

To associate a TAG to a user: 

1.  P

ress and hold the user number “0 to 9” key for 3 seconds (1 

is the master). 

A double beep is played and all LEDs light on. 

2.  Enter the master code or present the master tag. 

A beep is played and all status LEDs start flashing. 

3.  Present a new TAG. 

The programming mode ends automatically. 

4.  After a few seconds, a double beep is played and all status 

LED stop flashing. 

The operation fails if the TAG is already registered. 

If the user already has a TAG, the new one will take its place. 

To change 

a user’s code: 

1.  P

ress and hold the user number “0 to 9” key for 3 seconds (1 

is the master). 


background image

 

 

 

10 

A double beep is played and all LEDs light on. 

2.  Enter the master code or present the master tag. 

A high beep is played and all status LEDs start flashing. 

3.  Enter the code for the new user. A high beep is played. 

4.  Re-

enter new user’s code. A high beep is played. 

The programming mode ends automatically. 

5.  After a few seconds, a double beep is played and all status 

LED stop flashing. 

To 

disable a user’s code: 

To disable a use

r’s code and keep the TAG only: 

1. 

Press and hold the user number “0 to 9” key for 3 seconds (1 
is the master). 

A double beep is played and all LEDs light on. 

2.  Enter the master code or present the master tag. 

A high beep is played and all status LEDs start flashing. 

3.  Change the code to 0000 (or 000000 if 6 digits). 

4.  Re-enter the code 0000 (or 000000 if 6 digits). 

A high beep is played. 

5.  After a few seconds, a double beep is played and all status 

LED stop flashing. 

To disable a user: 

1.  Press and hold us

er number “0 to 9” key for 3 seconds. 

Note

: it is not possible to disable the master user. 

A double beep is played and all status LEDs light on. 

2.  Enter the master code or present the master tag. 

A high beep is played and all status LEDs start flashing. 

3.  Press the 

 key to disable the user. 

The programming mode ends automatically. 

4.  After a few seconds, a double beep is played and all status 

LED stop flashing. 


background image

11 

To enable a user: 

1.  Press and hold the 

user number “0 to 9” key for 3 seconds. 

A double beep is played and all status LEDs light on. 

2.  Enter the master code or present the master tag. 

A high beep is played and all status LEDs start flashing. 

3.  Press the

 key to enable the user. 

The programming mode ends automatically. 

4.  After a few seconds, a double beep is played and all status 

LED stop flashing. 

 

User Programming Mode Summary 

Procedure 

Entering prog 

Command 

Selection 

End 

Adjust beep 
volume 

+

 

(for 2 sec) 

Select the device 

 

several times 

Select level 

1 to 7 

 

Enable Chime 

+

 

(for 2 sec) 

 

 

 

Disable Chime 

+

 

(for 2 sec) 

 

 

 

 

Master User Programming Mode Summary 

Procedure 

Entering prog 

Authorization 

Selection 

End 

Assign TAG 

User key 0-9  

(for 3 sec) 

Master code or 

master TAG 

Present TAG 

 

Changing 

Code 

User key 0-9  

(for 3 sec) 

Master code or 

master TAG 

New user’s code  New user’s code 

Disabling 

Code 

User key 0-9  

(for 3 sec) 

Master code or 

master TAG 

0000 

(or 000000) 

0000 

(or 000000) 

Enable user 

User key 0-9  

(for 3 sec) 

Master code or 

master TAG 

 

 

Disable user 

User key 0-9  

(for 3 sec) 

Master code or 

master TAG 

 

 

 


background image

 

 

 

12 

Indicator lights (*) 

The front cover of the keypad features LED indicators which 
show the status of your security system. 

 

LED 1 

indicator “system armed” 

On:

 Total set is being armed. 

Flashing slowly

: Partial set is being armed. 

Flashing quickly

: Annex set is being armed. 

Off

: The system is disarmed. 

 

 

LED 2 

indicator “intruder alarm” 

On

: An intruder alarm is occurring or a detector is triggered on 

set. This includes open door-contact, movement detection or 
smoke detection. 

Flashing slowly

: An intruder alarm is in memory on set and 

requires a reset. 

Flashing quickly

: A confirmed alarm is in memory and requires 

a remote reset. Please call your monitoring operation at the 
alarm company. 

Off

: No intruder alarm. 

 

 

LED 3 

indicator “system fault” 

On

: A system fault is occurring on set. 

System faults include battery or power failure, supervision fault, 
GSM/GPRS failure or radio Jamming, smoke sensor failure. 
Please contact your alarm company if this indication persists. 

Flashing slowly:

 A system fault is in memory on set and 

requires a reset. 

Off

: No system fault. 

 

 

LED 4 

indicator “tamper alarm” 

On

: A tamper alarm is occurring on set. 

Flashing slowly

: A tamper alarm is in memory on set and 

requires a reset. 

Off:

 No tamper alarm.

 

 

(*) If keypad installed with CMI, HMI, Sucre Box panels. Refer to Annex A if keypad 
installed with PMI panels. 

 


background image

13 

Keypad tones 

 

*Can be set to silent mode depending on configuration. 

**

Defined during installation. 

TOTAL SET 
ARMING 

Sequence of 3 modulated 
sounds. 

 

Duration: 4 seconds 

When arming total set, 
confirms that the control 
panel has received a valid 
code or TAG and is 
preparing to arm total set. 

PARTIAL 
SET 
ARMING* 

ANNEX SET 
ARMING 

Sequence of 2 modulated 
sounds. 

 

Duration: 2, 5 seconds 

When arming the partial or 
annex set, confirms that the 
control panel has received a 
valid code or TAG and is 
preparing to arm partial or 
annex set. 

EXIT DELAY 

Upon arming... 

 

One double beep per second 
followed by faster double 
beep for 10s and then 2s 
continuous beep. 

Total and annex set arming: 
beeps continue until final exit 
door is closed. 
Partial* set arming: beeps 
continue for 30 seconds** 
until partial set is armed. 

ARMING 
COMPLETE 

After closing the final door. 

 

Three fast beeps 

When closing the final exit 
door, confirms that the 
system is armed. 

ENTRY 
DELAY 

Upon entry... 

 

One double beep per second 
followed by faster double 
beep for 10s and then 2s 
continuous beep. 

This entry tone lasts for 
30 seconds** after you open 
the entry door. You should 
disarm your system within 
this time. 

DISARMING 

Long and continuous beep 

 

Duration: 2, 5 seconds 

When Disarming, confirms 
that the control panel has 
been successfully disarmed. 

FAULT 

2 times 7 fast beeps. 

 

This signal indicates a fault 
in the system. 

ALERT 

4 beeps upon alert... 

 

sent via the keypad 

Confirms the transmission of 
an alert to the alarm 
company. 


background image

 

 

 

14 

Maintenance and recommendations 

 

  Check your system (once a month or according to your 

operator’s specifications). 

  Avoid shocks to all the components and especially avoid 

dropping the Tags. 

  Do not immerse components in water. 

  Do not use detergents to clean the components. Use a dry 

cloth only. 

  Keep components in a clean, dry place at room temperature. 

  Dispose of old batteries in containers provided for this 

purpose. 

  Avoid prolonged exposure to siren emissions. 

  Do not paint or paper over the components. 

  Do not try to open or move the components; they are tamper-

protected and some of them may cause electric shocks. 

Replacing the battery 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The 

“System Fault” LED indicates that the keypad battery may 

need to be replaced. The keypad will continue to operate for up to 
one month after this event. 

1.  Remove the keypad from the bracket with a suitable tool. 

2x CR123A 


background image

15 

Depending on panel configuration a tamper alarm is sent to 
the panel and there is a 120 second delay before transmitting 
the specific tamper message to the monitoring station. If 
tamper is restored before the end of the delay there is no 
transmission (the tamper delay is only when the system is 
disarmed. Tamper is immediately transmitted if the panel is 
armed). 

2.  Remove the batteries and replace them with the new batteries. 

 

3.  Install the keypad on its bracket. 

 

 

WARNING: RISK OF FIRE, EXPLOSION AND BURNS, DO NOT RECHARGE, 
DISASSEMBLE, HEAT ABOVE 100° C, OR INCINERATE THE BATTERY. WHILE 
THE BATTERY CAN NORMALLY BE SAFELY REMOVED BY HAND, CARE 
SHOULD BE USED TO ENSURE THAT THE BATTERY TERMINALS ARE NOT 
SHORTED, NOR THE BATTERY DAMAGED, DURING THE REMOVAL PROCESS. 
DISPOSE OF DEPLETED BATTERIES BY COMPLYING WITH APPLICABLE 
NATIONAL AND LOCAL REGULATIONS. IN THE EVENT OF THE BATTERY 
BEING DAMAGED, USE PERSONAL PROTECTIVE EQUIPMENT TO REMOVE IT 
IMMEDIATELY, AND DISPOSE OF IT IN A SAFE MANNER (REFER TO THE 
BATTERY MANUFACTURER

’S SPECIFICATIONS FOR SUCH SITUATIONS). FOR 

SWITZERLAND, ANNEX 4.10 OF SR 814.013 APPLIES TO THE BATTERY 
INCLUDED WITH THIS PRODUCT. THERE IS A RISK OF EXPLOSION IF THE 
CORRECT BATTERY IS NOT USED. REPLACE ONLY WITH LITHIUM BATTERY 
TYPE CR123A 

 

 

Please contact your local authorized Honeywell representative for product warranty 
information. All data and images in this document are subject to change without prior notice 
 

 


background image

 

 

 

16 

ANNEX A 

Indicator lights if keypad installed with PMI panels 

The front cover of the keypad features LED indicators which 
show the status of your security system. 

 

LED 1 indicator “system status” 

On:

 Total set is being armed. 

Flashing

: Partial or Annex set is being armed. 

Off

: The system is disarmed. 

 

 

LED 2 indicator “memorized alarm” 

On

: An intrusion occurred during the total set activation of the 

system. The indicator remains on until the next activation. 

Flashing

: An intrusion occurred during the partial or annex 

activation of the system. The indicator remains on until the next 
activation. 

Off

: No memorized alarm. 

 

 

LED 3 indicator “perimetric fault” 

Flashing:

 A window or a door protected by a magnetic contact 

is open. It flashes until the window or door has been closed. 

Off

: No perimetric fault. 

 

 

LED 4 indicator “system fault” 

On

: Activation of a technical or smoke detector. 

Flashing

: This indicates a fault in the system (battery, 

supervision or peripheral tamper fault, phone line failure or radio 
jamming). The indicator remains on or flashing until the fault is 
rectified. 

Off:

 No system fault.

 

 

 
 

 


background image

17 

Arming with a fault if keypad installed with PMI panels 

If the system diagnoses a fault on arming, a tone indicating a fault 
is emitted by the keypad after the arming tone. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Honeywell Security Group 
1198, Avenue du Docteur Maurice Donat 
BP 1219 
06254 MOUGINS CEDEX 
 
Tel:  +33 (0)4 92 94 29 50 
Fax: +33 (0)4 92 94 29 60 
 
www.honeywell.com/security/fr 
 

 

800-20982-A 

 
 

2015 Honeywell International Inc. 
 
Honeywell is a registered trademark of Honeywell International Inc.  
All other trademarks are the properties of their respective owners. All right reserved